CVE-2026-6888 (GCVE-0-2026-6888)
Vulnerability from cvelistv5 – Published: 2026-05-13 03:16 – Updated: 2026-05-13 14:35- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Advantech | SaaS Composer |
Affected:
prior to version 3.4.17
|
guessed | |
| Advantech | IoTSuite Growth Linux docker |
Affected:
prior to version 2.2.0
|
guessed | |
| Advantech | IoTSuite Starter Linux docker |
Affected:
prior to version 2.2.0
|
guessed | |
| Advantech | IoT Edge Linux docker |
Affected:
prior to version 2.2.0
|
guessed | |
| Advantech | IoT Edge Windows |
Affected:
prior to version 2.2.0
|
guessed | |
| Advantech | WebAccess/SCADA |
Affected:
prior to version 9.2.3
|
guessed | |
| Advantech | WebAccess SaaS-Composer |
Affected:
prior to version 3.4.17.1
|
guessed | |
| Advantech | ECOWatch SaaS-Composer |
Affected:
prior to version 3.4.17
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6888",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T14:35:40.247452Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T14:35:53.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SaaS Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Growth Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Starter Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Windows",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess/SCADA",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 9.2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "ECOWatch SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Hoa Ly Van Huu"
}
],
"datePublic": "2026-05-13T02:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSuccessful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database.\u003c/p\u003e"
}
],
"value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T03:16:24.701Z",
"orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"shortName": "CSA"
},
"references": [
{
"url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\u003c/p\u003e\n\n\u003cp\u003eFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u0026nbsp;\u003ca href=\"https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support\"\u003ehere\u0026nbsp;\u003c/a\u003efor\nthe official release of the fixed version.\u003c/p\u003e\n\n\u003cp\u003eFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor IoT Edge Linux docker, please\nrefer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide \u003ca href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ehere\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Users and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\n\n\n\n\n\nFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u00a0 here\u00a0 https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support for\nthe official release of the fixed version.\n\n\n\n\n\nFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ .\n\n\n\n\n\nFor IoT Edge Linux docker, please\nrefer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q .\n\n\n\n\n\nFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide here https://www.advantech.com/en/support/details/installation ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SQL Injection Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"assignerShortName": "CSA",
"cveId": "CVE-2026-6888",
"datePublished": "2026-05-13T03:16:24.701Z",
"dateReserved": "2026-04-23T02:58:12.750Z",
"dateUpdated": "2026-05-13T14:35:53.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-6888",
"date": "2026-11-26",
"epss": "0.00698",
"percentile": "0.48532"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SaaS Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Growth Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Starter Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Windows",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess/SCADA",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 9.2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "ECOWatch SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
}
],
"source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
},
{
"lang": "es",
"value": "Explotaci\u00f3n exitosa de la vulnerabilidad de inyecci\u00f3n SQL podr\u00eda permitir a un atacante remoto autenticado ejecutar comandos arbitrarios a trav\u00e9s de una interfaz espec\u00edfica, lo que podr\u00eda permitir al atacante acceder, modificar o eliminar informaci\u00f3n sensible dentro de la base de datos."
}
],
"id": "CVE-2026-6888",
"lastModified": "2026-10-26T18:10:00.173",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-6888",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T14:35:40.247452Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-05-13T04:17:41.093",
"references": [
{
"source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/"
}
],
"sourceIdentifier": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-06-05T19:17:17+00:00",
"cve": "CVE-2026-6888",
"id": "CVE-2026-6888",
"initial_release_date": "2026-05-13T02:54:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "SQL Injection Vulnerability",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-6888.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6888",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T14:35:40.247452Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T14:35:49.378Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SaaS Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Growth Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Starter Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Windows",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess/SCADA",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 9.2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "ECOWatch SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Hoa Ly Van Huu"
}
],
"datePublic": "2026-05-13T02:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSuccessful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database.\u003c/p\u003e"
}
],
"value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T03:16:24.701Z",
"orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"shortName": "CSA"
},
"references": [
{
"url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\u003c/p\u003e\n\n\u003cp\u003eFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u0026nbsp;\u003ca href=\"https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support\"\u003ehere\u0026nbsp;\u003c/a\u003efor\nthe official release of the fixed version.\u003c/p\u003e\n\n\u003cp\u003eFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor IoT Edge Linux docker, please\nrefer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide \u003ca href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ehere\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Users and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\n\n\n\n\n\nFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u00a0 here\u00a0 https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support for\nthe official release of the fixed version.\n\n\n\n\n\nFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ .\n\n\n\n\n\nFor IoT Edge Linux docker, please\nrefer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q .\n\n\n\n\n\nFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide here https://www.advantech.com/en/support/details/installation ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SQL Injection Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"assignerShortName": "CSA",
"cveId": "CVE-2026-6888",
"datePublished": "2026-05-13T03:16:24.701Z",
"dateReserved": "2026-04-23T02:58:12.750Z",
"dateUpdated": "2026-05-13T14:35:53.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.