CVE-2026-62437 (GCVE-0-2026-62437)
Vulnerability from cvelistv5 – Published: 2026-09-08 12:10 – Updated: 2026-09-08 17:08
VLAI
EPSS
VEX
Title
x86: DMs may cause mem leak by IRQ binding
Summary
When guests are terminated, various pieces of cleanup need carrying out.
The cleaning up of PCI devices which were assigned to guests, and the
associated removal of tracking structures for IRQs used by the devices
occurs relatively early in the process. Unfortunately after that point
the guest about to be terminated could cause its device model (DM) to
re-establish such tracking structures, by having it bind one or more IRQs
anew. While some of those tracking structures would still be cleaned up
later on, at least one would not be.
Severity
No CVSS data available.
Assigner
References
Impacted products
Date Public
2026-09-08 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-09-08T17:08:26.757Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://xenbits.xen.org/xsa/advisory-509.html"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/09/08/6"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Xen",
"vendor": "Xen",
"versions": [
{
"status": "unknown",
"version": "consult Xen advisory XSA-509"
}
]
}
],
"configurations": [
{
"lang": "en",
"value": "All Xen versions from at least 3.2 onwards are affected. Older versions\nhave not been inspected.\n\nOnly HVM guests with assigned PCI devices can leverage the vulnerability."
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This issue was discovered by Jan Beulich of SUSE."
}
],
"datePublic": "2026-09-08T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When guests are terminated, various pieces of cleanup need carrying out.\nThe cleaning up of PCI devices which were assigned to guests, and the\nassociated removal of tracking structures for IRQs used by the devices\noccurs relatively early in the process. Unfortunately after that point\nthe guest about to be terminated could cause its device model (DM) to\nre-establish such tracking structures, by having it bind one or more IRQs\nanew. While some of those tracking structures would still be cleaned up\nlater on, at least one would not be."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "A HVM guest with one or more PCI devices assigned can cause a memory leak\nin the hypervisor, possibly leading to Denial of Service (DoS) of the\nentire host."
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:10:52.643Z",
"orgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"shortName": "XEN"
},
"references": [
{
"url": "https://xenbits.xenproject.org/xsa/advisory-509.html"
}
],
"title": "x86: DMs may cause mem leak by IRQ binding",
"workarounds": [
{
"lang": "en",
"value": "Running only PV or PVH guests will avoid the vulnerability.\n\nRunning only HVM guests without passing through PCI devices to them will\nalso avoid the vulnerability."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"assignerShortName": "XEN",
"cveId": "CVE-2026-62437",
"datePublished": "2026-09-08T12:10:52.643Z",
"dateReserved": "2026-07-14T10:28:12.655Z",
"dateUpdated": "2026-09-08T17:08:26.757Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-62437\",\"sourceIdentifier\":\"security@xen.org\",\"published\":\"2026-09-08T13:17:19.623\",\"lastModified\":\"2026-09-08T19:20:25.117\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"When guests are terminated, various pieces of cleanup need carrying out.\\nThe cleaning up of PCI devices which were assigned to guests, and the\\nassociated removal of tracking structures for IRQs used by the devices\\noccurs relatively early in the process. Unfortunately after that point\\nthe guest about to be terminated could cause its device model (DM) to\\nre-establish such tracking structures, by having it bind one or more IRQs\\nanew. While some of those tracking structures would still be cleaned up\\nlater on, at least one would not be.\"}],\"affected\":[{\"source\":\"security@xen.org\",\"affectedData\":[{\"vendor\":\"Xen\",\"product\":\"Xen\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"consult Xen advisory XSA-509\",\"status\":\"unknown\"}]}]}],\"metrics\":{},\"references\":[{\"url\":\"https://xenbits.xenproject.org/xsa/advisory-509.html\",\"source\":\"security@xen.org\"},{\"url\":\"http://www.openwall.com/lists/oss-security/2026/09/08/6\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://xenbits.xen.org/xsa/advisory-509.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"redhat_vex": {
"current_release_date": "2026-09-08T21:26:22+00:00",
"cve": "CVE-2026-62437",
"id": "CVE-2026-62437",
"initial_release_date": "2026-09-08T12:10:52.643000+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "xen: Xen: Memory leak due to re-established IRQ tracking structures during guest termination",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-62437.json",
"version": "3"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…