CVE-2026-33608 (GCVE-0-2026-33608)

Vulnerability from cvelistv5 – Published: 2026-04-22 14:00 – Updated: 2026-04-22 14:28
VLAI?
Title
Incomplete domain name sanitization during
Summary
An attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.
CWE
  • Improper Control of Generation of Code ('Code Injection')
Assigner
OX
Impacted products
Vendor Product Version
PowerDNS Authoritative Affected: 5.0.0 , < 5.0.4 (semver)
Affected: 4.9.0 , < 4.9.14 (semver)
Create a notification for this product.
Date Public ?
2026-04-08 22:00
Credits
Vitaly Simonovich
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-33608",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-22T14:28:03.004705Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-22T14:28:15.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://repo.powerdns.com/",
          "defaultStatus": "unaffected",
          "modules": [
            "Bind backend"
          ],
          "packageName": "pdns",
          "product": "Authoritative",
          "programFiles": [
            "bindbackend2.cc"
          ],
          "repo": "https://github.com/PowerDNS/pdns",
          "vendor": "PowerDNS",
          "versions": [
            {
              "lessThan": "5.0.4",
              "status": "affected",
              "version": "5.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "4.9.14",
              "status": "affected",
              "version": "4.9.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Vitaly Simonovich"
        }
      ],
      "datePublic": "2026-04-08T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.\u003c/p\u003e"
            }
          ],
          "value": "An attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-22T14:00:15.473Z",
        "orgId": "8ce71d90-2354-404b-a86e-bec2cc4e6981",
        "shortName": "OX"
      },
      "references": [
        {
          "url": "https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-05.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Incomplete domain name sanitization during",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8ce71d90-2354-404b-a86e-bec2cc4e6981",
    "assignerShortName": "OX",
    "cveId": "CVE-2026-33608",
    "datePublished": "2026-04-22T14:00:15.473Z",
    "dateReserved": "2026-03-23T12:58:38.267Z",
    "dateUpdated": "2026-04-22T14:28:15.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-33608",
      "date": "2026-04-23",
      "epss": "5e-05",
      "percentile": "0.0029"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-33608\",\"sourceIdentifier\":\"security@open-xchange.com\",\"published\":\"2026-04-22T14:16:54.650\",\"lastModified\":\"2026-04-22T21:23:52.620\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@open-xchange.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"references\":[{\"url\":\"https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-05.html\",\"source\":\"security@open-xchange.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-33608\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-22T14:28:03.004705Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-22T14:27:55.851Z\"}}], \"cna\": {\"title\": \"Incomplete domain name sanitization during\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Vitaly Simonovich\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"repo\": \"https://github.com/PowerDNS/pdns\", \"vendor\": \"PowerDNS\", \"modules\": [\"Bind backend\"], \"product\": \"Authoritative\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.0.0\", \"lessThan\": \"5.0.4\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"4.9.0\", \"lessThan\": \"4.9.14\", \"versionType\": \"semver\"}], \"packageName\": \"pdns\", \"programFiles\": [\"bindbackend2.cc\"], \"collectionURL\": \"https://repo.powerdns.com/\", \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-04-08T22:00:00.000Z\", \"references\": [{\"url\": \"https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-05.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"description\": \"Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"8ce71d90-2354-404b-a86e-bec2cc4e6981\", \"shortName\": \"OX\", \"dateUpdated\": \"2026-04-22T14:00:15.473Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-33608\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-22T14:28:15.172Z\", \"dateReserved\": \"2026-03-23T12:58:38.267Z\", \"assignerOrgId\": \"8ce71d90-2354-404b-a86e-bec2cc4e6981\", \"datePublished\": \"2026-04-22T14:00:15.473Z\", \"assignerShortName\": \"OX\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…