CVE-2026-20232 (GCVE-0-2026-20232)
Vulnerability from cvelistv5 – Published: 2026-08-19 16:16 – Updated: 2026-08-19 19:19
VLAI
EPSS
VEX
Title
Cisco Industrial Ethernet 1000 Series Switches Stored Cross-Site Scripting Vulnerability
Summary
A vulnerability in the web-based management interface of Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface.
This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected system. An attacker could exploit this vulnerability by injecting malicious code into specific pages of the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of another user. To exploit this vulnerability, the attacker must have valid user credentials on the affected system.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-19 19:19 UTC
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Cisco | Cisco Industrial Ethernet Switches |
Affected:
1.1
Affected: 1.2 Affected: 1.8.0 Affected: 1.8.2 Affected: 1.7.0 Affected: 1.3 Affected: 1.9.1 Affected: 1.6 Affected: 1.8.1 Affected: 1.9.2 Affected: 1.9.2a Affected: 1.9.3 Affected: 1.9.4 Affected: 1.9.5 |
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-20232",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-19T19:19:25.481775Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T19:19:39.460Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Cisco Industrial Ethernet Switches",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "1.1"
},
{
"status": "affected",
"version": "1.2"
},
{
"status": "affected",
"version": "1.8.0"
},
{
"status": "affected",
"version": "1.8.2"
},
{
"status": "affected",
"version": "1.7.0"
},
{
"status": "affected",
"version": "1.3"
},
{
"status": "affected",
"version": "1.9.1"
},
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.8.1"
},
{
"status": "affected",
"version": "1.9.2"
},
{
"status": "affected",
"version": "1.9.2a"
},
{
"status": "affected",
"version": "1.9.3"
},
{
"status": "affected",
"version": "1.9.4"
},
{
"status": "affected",
"version": "1.9.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web-based management interface of Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface.\r\n\r\nThis vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected system. An attacker could exploit this vulnerability by injecting malicious code into specific pages of the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of another user. To exploit this vulnerability, the attacker must have valid user credentials on the affected system."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "cvssV3_1"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "cwe"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T16:16:59.219Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "cisco-sa-ie1k-NgXUFF52",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ie1k-NgXUFF52"
}
],
"source": {
"advisory": "cisco-sa-ie1k-NgXUFF52",
"defects": [
"CSCws55646"
],
"discovery": "EXTERNAL"
},
"title": "Cisco Industrial Ethernet 1000 Series Switches Stored Cross-Site Scripting Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2026-20232",
"datePublished": "2026-08-19T16:16:59.219Z",
"dateReserved": "2025-10-08T11:59:15.399Z",
"dateUpdated": "2026-08-19T19:19:39.460Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-20232",
"date": "2026-08-22",
"epss": "0.00205",
"percentile": "0.10815"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-20232\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2026-08-19T17:18:39.390\",\"lastModified\":\"2026-08-20T13:01:19.947\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface.\\r\\n\\r\\nThis vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected system. An attacker could exploit this vulnerability by injecting malicious code into specific pages of the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of another user. To exploit this vulnerability, the attacker must have valid user credentials on the affected system.\"}],\"affected\":[{\"source\":\"psirt@cisco.com\",\"affectedData\":[{\"vendor\":\"Cisco\",\"product\":\"Cisco Industrial Ethernet Switches\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"1.1\",\"status\":\"affected\"},{\"version\":\"1.2\",\"status\":\"affected\"},{\"version\":\"1.8.0\",\"status\":\"affected\"},{\"version\":\"1.8.2\",\"status\":\"affected\"},{\"version\":\"1.7.0\",\"status\":\"affected\"},{\"version\":\"1.3\",\"status\":\"affected\"},{\"version\":\"1.9.1\",\"status\":\"affected\"},{\"version\":\"1.6\",\"status\":\"affected\"},{\"version\":\"1.8.1\",\"status\":\"affected\"},{\"version\":\"1.9.2\",\"status\":\"affected\"},{\"version\":\"1.9.2a\",\"status\":\"affected\"},{\"version\":\"1.9.3\",\"status\":\"affected\"},{\"version\":\"1.9.4\",\"status\":\"affected\"},{\"version\":\"1.9.5\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-08-19T19:19:25.481775Z\",\"id\":\"CVE-2026-20232\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]}],\"references\":[{\"url\":\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ie1k-NgXUFF52\",\"source\":\"psirt@cisco.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-20232\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-19T19:19:25.481775Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-19T19:19:31.484Z\"}}], \"cna\": {\"title\": \"Cisco Industrial Ethernet 1000 Series Switches Stored Cross-Site Scripting Vulnerability\", \"source\": {\"defects\": [\"CSCws55646\"], \"advisory\": \"cisco-sa-ie1k-NgXUFF52\", \"discovery\": \"EXTERNAL\"}, \"metrics\": [{\"format\": \"cvssV3_1\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco Industrial Ethernet Switches\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.1\"}, {\"status\": \"affected\", \"version\": \"1.2\"}, {\"status\": \"affected\", \"version\": \"1.8.0\"}, {\"status\": \"affected\", \"version\": \"1.8.2\"}, {\"status\": \"affected\", \"version\": \"1.7.0\"}, {\"status\": \"affected\", \"version\": \"1.3\"}, {\"status\": \"affected\", \"version\": \"1.9.1\"}, {\"status\": \"affected\", \"version\": \"1.6\"}, {\"status\": \"affected\", \"version\": \"1.8.1\"}, {\"status\": \"affected\", \"version\": \"1.9.2\"}, {\"status\": \"affected\", \"version\": \"1.9.2a\"}, {\"status\": \"affected\", \"version\": \"1.9.3\"}, {\"status\": \"affected\", \"version\": \"1.9.4\"}, {\"status\": \"affected\", \"version\": \"1.9.5\"}], \"defaultStatus\": \"unknown\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"references\": [{\"url\": \"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ie1k-NgXUFF52\", \"name\": \"cisco-sa-ie1k-NgXUFF52\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based management interface of Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface.\\r\\n\\r\\nThis vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected system. An attacker could exploit this vulnerability by injecting malicious code into specific pages of the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of another user. To exploit this vulnerability, the attacker must have valid user credentials on the affected system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"cwe\", \"cweId\": \"CWE-80\", \"description\": \"Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2026-08-19T16:16:59.219Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-20232\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-19T19:19:39.460Z\", \"dateReserved\": \"2025-10-08T11:59:15.399Z\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2026-08-19T16:16:59.219Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…