CVE-2026-1762 (GCVE-0-2026-1762)
Vulnerability from cvelistv5 – Published: 2026-02-10 20:06 – Updated: 2026-03-04 18:39| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| GE Vernova | Enervista |
Affected:
8.6 and prior versions
(Linux)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1762",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T20:34:57.688134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T20:37:25.289Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "UR Setup",
"platforms": [
"Windows"
],
"product": "Enervista",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.6 and prior versions",
"versionType": "Linux"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Reid Wightman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.\u003cp\u003eThis issue affects Enervista: 8.6 and prior versions.\u003c/p\u003e"
}
],
"value": "A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.This issue affects Enervista: 8.6 and prior versions."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 2.9,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-04T18:39:46.742Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/ges-2025-005.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "We strongly recommend that users with impacted firmware versions update their UR devices to UR \nfirmware version 8.70, released in November 2025, to resolve these vulnerabilities. We also recommend \nupgrading the EnerVista UR Setup configuration tool to version 8.70 or greater. \u003cbr\u003e\u003cbr\u003e\nEnervista UR Setup software is backward compatible, users can upgrade it to version 8.70, \nindependently of upgrading their UR IED to FW v870.\n\n\u003cbr\u003e"
}
],
"value": "We strongly recommend that users with impacted firmware versions update their UR devices to UR \nfirmware version 8.70, released in November 2025, to resolve these vulnerabilities. We also recommend \nupgrading the EnerVista UR Setup configuration tool to version 8.70 or greater. \n\n\nEnervista UR Setup software is backward compatible, users can upgrade it to version 8.70, \nindependently of upgrading their UR IED to FW v870."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Enervista UR Setup Directory Traversal Vulnerability",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "As a workaround, GE Vernova recommends having secure infrastructure in place, which can protect the \nsystem. We also recommend that customers protect their digital devices using a defense-in-depth \nstrategy. This includes, but is not limited to, placing digital devices inside the control system network \nsecurity perimeter, access controls, robust network monitoring (such as Intrusion Detection System) and \nother mitigation techniques in place. Please refer to the product secure deployment guide.\n\nIt is essential for organizations to prioritize cybersecurity measures, including regular vulnerability \nassessments and prompt application of security patches.\n\n \n\n\n\u003cbr\u003e"
}
],
"value": "As a workaround, GE Vernova recommends having secure infrastructure in place, which can protect the \nsystem. We also recommend that customers protect their digital devices using a defense-in-depth \nstrategy. This includes, but is not limited to, placing digital devices inside the control system network \nsecurity perimeter, access controls, robust network monitoring (such as Intrusion Detection System) and \nother mitigation techniques in place. Please refer to the product secure deployment guide.\n\nIt is essential for organizations to prioritize cybersecurity measures, including regular vulnerability \nassessments and prompt application of security patches."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2026-1762",
"datePublished": "2026-02-10T20:06:00.213Z",
"dateReserved": "2026-02-02T14:36:44.351Z",
"dateUpdated": "2026-03-04T18:39:46.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-1762",
"date": "2026-11-13",
"epss": "0.00254",
"percentile": "0.17133"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"packageName": "UR Setup",
"platforms": [
"Windows"
],
"product": "Enervista",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.6 and prior versions",
"versionType": "Linux"
}
]
}
],
"source": "GEPowerCVD@ge.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.This issue affects Enervista: 8.6 and prior versions."
},
{
"lang": "es",
"value": "Una vulnerabilidad en GE Vernova Enervista UR Setup en Windows permite la manipulaci\u00f3n de archivos. Este problema afecta a Enervista: 8.6 y versiones anteriores."
}
],
"id": "CVE-2026-1762",
"lastModified": "2026-06-17T10:16:28.490",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 2.9,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.3,
"impactScore": 2.5,
"source": "GEPowerCVD@ge.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-1762",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T20:34:57.688134Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-02-10T20:16:52.940",
"references": [
{
"source": "GEPowerCVD@ge.com",
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/ges-2025-005.pdf"
}
],
"sourceIdentifier": "GEPowerCVD@ge.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-23"
}
],
"source": "GEPowerCVD@ge.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T08:10:51+00:00",
"cve": "CVE-2026-1762",
"id": "CVE-2026-1762",
"initial_release_date": "2026-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Enervista UR Setup Directory Traversal Vulnerability",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-1762.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1762",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T20:34:57.688134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T20:37:20.530Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "UR Setup",
"platforms": [
"Windows"
],
"product": "Enervista",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.6 and prior versions",
"versionType": "Linux"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Reid Wightman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.\u003cp\u003eThis issue affects Enervista: 8.6 and prior versions.\u003c/p\u003e"
}
],
"value": "A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.This issue affects Enervista: 8.6 and prior versions."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 2.9,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-04T18:39:46.742Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/ges-2025-005.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "We strongly recommend that users with impacted firmware versions update their UR devices to UR \nfirmware version 8.70, released in November 2025, to resolve these vulnerabilities. We also recommend \nupgrading the EnerVista UR Setup configuration tool to version 8.70 or greater. \u003cbr\u003e\u003cbr\u003e\nEnervista UR Setup software is backward compatible, users can upgrade it to version 8.70, \nindependently of upgrading their UR IED to FW v870.\n\n\u003cbr\u003e"
}
],
"value": "We strongly recommend that users with impacted firmware versions update their UR devices to UR \nfirmware version 8.70, released in November 2025, to resolve these vulnerabilities. We also recommend \nupgrading the EnerVista UR Setup configuration tool to version 8.70 or greater. \n\n\nEnervista UR Setup software is backward compatible, users can upgrade it to version 8.70, \nindependently of upgrading their UR IED to FW v870."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Enervista UR Setup Directory Traversal Vulnerability",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "As a workaround, GE Vernova recommends having secure infrastructure in place, which can protect the \nsystem. We also recommend that customers protect their digital devices using a defense-in-depth \nstrategy. This includes, but is not limited to, placing digital devices inside the control system network \nsecurity perimeter, access controls, robust network monitoring (such as Intrusion Detection System) and \nother mitigation techniques in place. Please refer to the product secure deployment guide.\n\nIt is essential for organizations to prioritize cybersecurity measures, including regular vulnerability \nassessments and prompt application of security patches.\n\n \n\n\n\u003cbr\u003e"
}
],
"value": "As a workaround, GE Vernova recommends having secure infrastructure in place, which can protect the \nsystem. We also recommend that customers protect their digital devices using a defense-in-depth \nstrategy. This includes, but is not limited to, placing digital devices inside the control system network \nsecurity perimeter, access controls, robust network monitoring (such as Intrusion Detection System) and \nother mitigation techniques in place. Please refer to the product secure deployment guide.\n\nIt is essential for organizations to prioritize cybersecurity measures, including regular vulnerability \nassessments and prompt application of security patches."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2026-1762",
"datePublished": "2026-02-10T20:06:00.213Z",
"dateReserved": "2026-02-02T14:36:44.351Z",
"dateUpdated": "2026-03-04T18:39:46.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.