CVE-2026-11730 (GCVE-0-2026-11730)

Vulnerability from cvelistv5 – Published: 2026-10-13 14:38 – Updated: 2026-10-13 16:40
VLAI
Title
Insufficient session randomness vulnerability exists in certain NETGEAR EX Series Models
Summary
Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal.
CWE
  • CWE-335 - Incorrect usage of seeds in Pseudo-Random number generator (PRNG)
Assigner
NETGEAR CNA under the mitre root
CNA scorecard A 92/100 over 40 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
NETGEAR EX3700 Affected: 0 , < V1.0.0.102 (custom)
guessed Create a notification for this product.
NETGEAR EX6120 Affected: 0 , < V1.0.1.74 (custom)
guessed Create a notification for this product.
Date Public
2026-10-13 00:00
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EX3700",
          "vendor": "NETGEAR",
          "versions": [
            {
              "lessThan": "V1.0.0.102",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EX6120",
          "vendor": "NETGEAR",
          "versions": [
            {
              "lessThan": "V1.0.1.74",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "KDec5ae262-35b5-41c5-9bc1-91ad34145487 and Austin Turecek (Collaborator)"
        }
      ],
      "datePublic": "2026-10-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eInsufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal.\u0026nbsp;\u003c/p\u003e"
            }
          ],
          "value": "Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-593",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-593 Session Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 2.1,
            "baseSeverity": "LOW",
            "exploitMaturity": "UNREPORTED",
            "privilegesRequired": "LOW",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/V:D/RE:L/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-335",
              "description": "CWE-335 Incorrect usage of seeds in Pseudo-Random number generator (PRNG)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T16:40:22.452Z",
        "orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
        "shortName": "NETGEAR"
      },
      "references": [
        {
          "tags": [
            "product",
            "patch"
          ],
          "url": "https://www.netgear.com/support/product/ex3700"
        },
        {
          "tags": [
            "product",
            "patch"
          ],
          "url": "https://www.netgear.com/support/product/ex6120"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDevices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\u003c/p\u003e\u003ctable style=\"border-collapse:collapse;\"\u003e\u003cthead\u003e\u003ctr\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eProduct\u003c/th\u003e\u003cth style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003eFixed Version\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX3700 (EoS)\u003c/b\u003e AC750 WiFi Range Extender Essentials Edition\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex3700\"\u003eV1.0.0.102\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003cb\u003eEX6120\u003c/b\u003e AC1200 Dual Band WiFi Range Extender\u003c/td\u003e\u003ctd style=\"border:1px solid gray;padding:4px 8px;text-align:left;\"\u003e\u003ca href=\"https://www.netgear.com/support/product/ex6120\"\u003eV1.0.1.74\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cp\u003eModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support.\u003c/p\u003e"
            }
          ],
          "value": "Devices with automatic updates enabled may already have this patch applied. If not, please check the firmware version and update it to the latest. Fixed in:\n\nProductFixed VersionEX3700 (EoS) AC750 WiFi Range Extender Essentials Edition V1.0.0.102 https://www.netgear.com/support/product/ex3700 EX6120 AC1200 Dual Band WiFi Range Extender V1.0.1.74 https://www.netgear.com/support/product/ex6120 \n\nModels marked (EoS) have reached End-of-Support phase, and no security updates are planned. NETGEAR strongly recommends that you retire these devices and upgrade to a newer NETGEAR device for continued security support."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Insufficient session randomness vulnerability exists in certain NETGEAR EX Series Models",
      "x_generator": {
        "engine": "Vulnogram 1.0.3"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
    "assignerShortName": "NETGEAR",
    "cveId": "CVE-2026-11730",
    "datePublished": "2026-10-13T14:38:16.110Z",
    "dateReserved": "2026-06-09T02:46:38.130Z",
    "dateUpdated": "2026-10-13T16:40:22.452Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-11730",
      "date": "2026-10-14",
      "epss": "0.0016",
      "percentile": "0.04744"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "EX3700",
                "vendor": "NETGEAR",
                "versions": [
                  {
                    "lessThan": "V1.0.0.102",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "EX6120",
                "vendor": "NETGEAR",
                "versions": [
                  {
                    "lessThan": "V1.0.1.74",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "a2826606-91e7-4eb6-899e-8484bd4575d5"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Insufficient session randomness vulnerability in the listed NETGEAR Extender models allows a network-adjacent attacker having network access (such as WiFi credentials) to predict valid session identifiers and hijack an authenticated administrator session on the web management portal."
          }
        ],
        "id": "CVE-2026-11730",
        "lastModified": "2026-10-13T17:17:39.130",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 4.2,
              "source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 2.1,
                "baseSeverity": "LOW",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "UNREPORTED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:D/RE:L/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "LOW"
              },
              "source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
              "type": "Secondary"
            }
          ]
        },
        "published": "2026-10-13T15:17:43.340",
        "references": [
          {
            "source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
            "url": "https://www.netgear.com/support/product/ex3700"
          },
          {
            "source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
            "url": "https://www.netgear.com/support/product/ex6120"
          }
        ],
        "sourceIdentifier": "a2826606-91e7-4eb6-899e-8484bd4575d5",
        "vulnStatus": "Received",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-335"
              }
            ],
            "source": "a2826606-91e7-4eb6-899e-8484bd4575d5",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.