CVE-2025-9998 (GCVE-0-2025-9998)
Vulnerability from cvelistv5 – Published: 2025-09-05 16:40 – Updated: 2026-02-26 07:54
VLAI?
Title
Improper validation of packets sequencing
Summary
The sequence of packets received by a Networking server are not correctly checked.
An attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.
Severity ?
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
Guillaume André (Synacktiv)
Pierre Gertner (Synacktiv)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9998",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-05T17:51:03.059305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-05T17:51:49.768Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"modules": [
"Networking"
],
"product": "PcVue",
"vendor": "arcinfo",
"versions": [
{
"lessThanOrEqual": "16.3.3",
"status": "affected",
"version": "16.0.0",
"versionType": "cpe"
},
{
"lessThanOrEqual": "15.2.12",
"status": "affected",
"version": "15.0.0",
"versionType": "cpe"
},
{
"lessThanOrEqual": "12.0.31",
"status": "affected",
"version": "12.0.0",
"versionType": "cpe"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "16.3.3",
"versionStartIncluding": "16.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "15.2.12",
"versionStartIncluding": "15.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
"versionEndIncluding": "12.0.31",
"versionStartIncluding": "12.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Guillaume Andr\u00e9 (Synacktiv)"
},
{
"lang": "en",
"type": "finder",
"value": "Pierre Gertner (Synacktiv)"
}
],
"datePublic": "2025-09-04T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The sequence of packets received by a Networking server are not correctly checked.\u003cbr\u003e\u003cbr\u003eAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\u003cbr\u003e"
}
],
"value": "The sequence of packets received by a Networking server are not correctly checked.\n\nAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No POC available."
}
],
"value": "No POC available."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not known to be exploited"
}
],
"value": "Not known to be exploited"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"other": {
"content": {
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CNA",
"version": "2.0.3"
},
"type": "ssvc"
},
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T07:54:07.047Z",
"orgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"shortName": "arcinfo"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.pcvue.com/security/#SB2025-4"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003eHarden the configuration\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users\u003cbr\u003eTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\u003cbr\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003eUpdate PcVue\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users running affected components.\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eA fixed release must be installed on all stations for the fix to be fully applied.\u003c/b\u003e\u003cbr\u003eExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\n\n(\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\"\u003ehttps://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\u003c/a\u003e)\n\n.\u003cbr\u003eFor new projects, the settings are configured by default with secured values.\u003cbr\u003e\u003cbr\u003eTo verify that the patch has been applied correctly, the user must check that:\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe \u003ci\u003eFile version\u003c/i\u003e property of the file \u003ci\u003e./bin/sv32.exe\u003c/i\u003e matches the deployed release or later, and ensure that any earlier release is no longer used;\u003c/li\u003e\u003cli\u003eThe \u003ci\u003eInteroperability issues\u003c/i\u003e settings of the Networking feature are disabled.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cbr\u003e\n\n\u003cb\u003eAvailable patches:\u003c/b\u003e\u003cbr\u003ePatch provided in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.3.4 (16.3.4902.3112)\u003c/li\u003e\u003cli\u003ePcVue 15.2.13 (15.2.13902.37126)\u003c/li\u003e\u003cli\u003ePcVue 12.0.32 (12.0.32900.37130)\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Harden the configuration\nWho should apply this recommendation: All users\nTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\n * Locate control system networks and remote devices behind firewalls and isolate them from business networks.\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n\n\n\nUpdate PcVue\nWho should apply this recommendation: All users running affected components.\nApply the patch by installing a fixed PcVue version.\n\nA fixed release must be installed on all stations for the fix to be fully applied.\nExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\n\n( https://www.pcvue.com/?post_type=post\u0026s=\u0026kbase_id=kb1254 )\n\n.\nFor new projects, the settings are configured by default with secured values.\n\nTo verify that the patch has been applied correctly, the user must check that:\n * The File version property of the file ./bin/sv32.exe matches the deployed release or later, and ensure that any earlier release is no longer used;\n * The Interoperability issues settings of the Networking feature are disabled.\n\n\n\n\n\n\nAvailable patches:\nPatch provided in:\n * PcVue 16.3.4 (16.3.4902.3112)\n * PcVue 15.2.13 (15.2.13902.37126)\n * PcVue 12.0.32 (12.0.32900.37130)"
}
],
"source": {
"advisory": "SB2025-4",
"discovery": "EXTERNAL"
},
"title": "Improper validation of packets sequencing",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"assignerShortName": "arcinfo",
"cveId": "CVE-2025-9998",
"datePublished": "2025-09-05T16:40:13.645Z",
"dateReserved": "2025-09-04T16:34:22.785Z",
"dateUpdated": "2026-02-26T07:54:07.047Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-9998\",\"sourceIdentifier\":\"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\",\"published\":\"2025-09-05T17:15:40.040\",\"lastModified\":\"2025-09-05T17:47:10.303\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The sequence of packets received by a Networking server are not correctly checked.\\n\\nAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:Green\",\"baseScore\":6.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"YES\",\"Recovery\":\"USER\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"MODERATE\",\"providerUrgency\":\"GREEN\"}}]},\"weaknesses\":[{\"source\":\"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"references\":[{\"url\":\"https://www.pcvue.com/security/#SB2025-4\",\"source\":\"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9998\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-05T17:51:03.059305Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-05T17:51:06.873Z\"}}], \"cna\": {\"title\": \"Improper validation of packets sequencing\", \"source\": {\"advisory\": \"SB2025-4\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Guillaume Andr\\u00e9 (Synacktiv)\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Pierre Gertner (Synacktiv)\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"USER\", \"baseScore\": 6, \"Automatable\": \"YES\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Green\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"GREEN\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"role\": \"CNA\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\"}}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"arcinfo\", \"modules\": [\"Networking\"], \"product\": \"PcVue\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"16.3.3\"}, {\"status\": \"affected\", \"version\": \"15.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"15.2.12\"}, {\"status\": \"affected\", \"version\": \"12.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"12.0.31\"}], \"defaultStatus\": \"affected\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"No POC available.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"No POC available.\", \"base64\": false}]}, {\"lang\": \"en\", \"value\": \"Not known to be exploited\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Not known to be exploited\", \"base64\": false}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Harden the configuration\\nWho should apply this recommendation: All users\\nTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\\n * Locate control system networks and remote devices behind firewalls and isolate them from business networks.\\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\\n\\n\\nUpdate PcVue\\nWho should apply this recommendation: All users running affected components.\\nApply the patch by installing a fixed PcVue version.\\n\\nA fixed release must be installed on all stations for the fix to be fully applied.\\nExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\\n\\n( https://www.pcvue.com/?post_type=post\u0026s=\u0026kbase_id=kb1254 )\\n\\n.\\nFor new projects, the settings are configured by default with secured values.\\n\\nTo verify that the patch has been applied correctly, the user must check that:\\n * The File version property of the file ./bin/sv32.exe matches the deployed release or later, and ensure that any earlier release is no longer used;\\n * The Interoperability issues settings of the Networking feature are disabled.\\n\\n\\n\\n\\n\\n\\nAvailable patches:\\nPatch provided in:\\n * PcVue 16.3.4 (16.3.4902.3112)\\n * PcVue 15.2.13 (15.2.13902.37126)\\n * PcVue 12.0.32 (12.0.32900.37130)\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cb\u003eHarden the configuration\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users\u003cbr\u003eTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\u003cbr\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003eUpdate PcVue\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users running affected components.\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eA fixed release must be installed on all stations for the fix to be fully applied.\u003c/b\u003e\u003cbr\u003eExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\\n\\n(\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\\\"\u003ehttps://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\u003c/a\u003e)\\n\\n.\u003cbr\u003eFor new projects, the settings are configured by default with secured values.\u003cbr\u003e\u003cbr\u003eTo verify that the patch has been applied correctly, the user must check that:\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe \u003ci\u003eFile version\u003c/i\u003e property of the file \u003ci\u003e./bin/sv32.exe\u003c/i\u003e matches the deployed release or later, and ensure that any earlier release is no longer used;\u003c/li\u003e\u003cli\u003eThe \u003ci\u003eInteroperability issues\u003c/i\u003e settings of the Networking feature are disabled.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cbr\u003e\\n\\n\u003cb\u003eAvailable patches:\u003c/b\u003e\u003cbr\u003ePatch provided in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.3.4 (16.3.4902.3112)\u003c/li\u003e\u003cli\u003ePcVue 15.2.13 (15.2.13902.37126)\u003c/li\u003e\u003cli\u003ePcVue 12.0.32 (12.0.32900.37130)\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"datePublic\": \"2025-09-04T22:00:00.000Z\", \"references\": [{\"url\": \"https://www.pcvue.com/security/#SB2025-4\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The sequence of packets received by a Networking server are not correctly checked.\\n\\nAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The sequence of packets received by a Networking server are not correctly checked.\u003cbr\u003e\u003cbr\u003eAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-754\", \"description\": \"CWE-754 Improper Check for Unusual or Exceptional Conditions\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"16.3.3\", \"versionStartIncluding\": \"16.0.0\"}, {\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"15.2.12\", \"versionStartIncluding\": \"15.0.0\"}, {\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"12.0.31\", \"versionStartIncluding\": \"12.0.0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\", \"shortName\": \"arcinfo\", \"dateUpdated\": \"2026-02-26T07:54:07.047Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-9998\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-26T07:54:07.047Z\", \"dateReserved\": \"2025-09-04T16:34:22.785Z\", \"assignerOrgId\": \"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\", \"datePublished\": \"2025-09-05T16:40:13.645Z\", \"assignerShortName\": \"arcinfo\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…