CVE-2025-9313 (GCVE-0-2025-9313)

Vulnerability from cvelistv5 – Published: 2025-10-28 11:49 – Updated: 2025-10-28 13:15
VLAI
Title
Unauthorized database access in Asseco mMedica
Summary
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-28 13:15 UTC
CWE
  • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
CERT-PL CNA under the ENISA root
CNA scorecard B 81/100 over 219 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Asseco Poland S.A. mMedica Affected: 0 , < 11.9.5 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:15:10.082135Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-28T13:15:31.459Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mMedica",
          "vendor": "Asseco Poland S.A.",
          "versions": [
            {
              "lessThan": "11.9.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\u003cbr\u003e\u003cbr\u003eThis issue affects Asseco mMedica in versions before 11.9.5."
            }
          ],
          "value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-28T11:49:29.119Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2025/10/CVE-2025-9313/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://mmedica.asseco.pl/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthorized database access in Asseco mMedica",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2025-9313",
    "datePublished": "2025-10-28T11:49:29.119Z",
    "dateReserved": "2025-08-21T07:29:05.144Z",
    "dateUpdated": "2025-10-28T13:15:31.459Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-9313",
      "date": "2026-10-21",
      "epss": "0.00429",
      "percentile": "0.3607"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "mMedica",
                "vendor": "Asseco Poland S.A.",
                "versions": [
                  {
                    "lessThan": "11.9.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cvd@cert.pl"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5."
          },
          {
            "lang": "es",
            "value": "Un usuario no autenticado puede conectarse a una base de datos de acceso p\u00fablico utilizando credenciales arbitrarias. El sistema otorga acceso total a la base de datos aprovechando una conexi\u00f3n previamente autenticada a trav\u00e9s de una aplicaci\u00f3n \u0027mmBackup\u0027. Esta falla permite a los atacantes eludir los mecanismos de autenticaci\u00f3n y obtener acceso no autorizado a la base de datos con datos sensibles.\n\nEste problema afecta a Asseco mMedica en versiones anteriores a la 11.9.5."
          }
        ],
        "id": "CVE-2025-9313",
        "lastModified": "2026-10-08T11:10:00.250",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cvd@cert.pl",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-9313",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:15:10.082135Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-10-28T12:15:42.967",
        "references": [
          {
            "source": "cvd@cert.pl",
            "url": "https://cert.pl/en/posts/2025/10/CVE-2025-9313/"
          },
          {
            "source": "cvd@cert.pl",
            "url": "https://mmedica.asseco.pl/"
          }
        ],
        "sourceIdentifier": "cvd@cert.pl",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-288"
              }
            ],
            "source": "cvd@cert.pl",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-10-29T12:28:41+00:00",
      "cve": "CVE-2025-9313",
      "id": "CVE-2025-9313",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Unauthorized database access in Asseco mMedica",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-9313.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9313",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-28T13:15:10.082135Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-28T13:15:24.252Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mMedica",
              "vendor": "Asseco Poland S.A.",
              "versions": [
                {
                  "lessThan": "11.9.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\u003cbr\u003e\u003cbr\u003eThis issue affects Asseco mMedica in versions before 11.9.5."
                }
              ],
              "value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-28T11:49:29.119Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2025/10/CVE-2025-9313/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://mmedica.asseco.pl/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthorized database access in Asseco mMedica",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-9313",
        "datePublished": "2025-10-28T11:49:29.119Z",
        "dateReserved": "2025-08-21T07:29:05.144Z",
        "dateUpdated": "2025-10-28T13:15:31.459Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.