CVE-2025-47419 (GCVE-0-2025-47419)
Vulnerability from cvelistv5 – Published: 2025-05-06 20:52 – Updated: 2025-05-07 14:03
VLAI
EPSS
VEX
Title
Non-Secure Access
Summary
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-07 13:47 UTC
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://security.crestron.com/ | vendor-advisory |
| https://www.crestron.com/Software-Firmware/Softwa… | patch |
| https://www.crestron.com/release_notes/automate_v… | release-notes |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Crestron | Automate VX |
Affected:
5.6.8161.21536 , ≤ 6.4.0.49
(custom)
|
guessed |
Date Public
2025-04-23 20:47
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47419",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:47:55.617300Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T14:03:57.638Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T20:47:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\u003cbr\u003e\u003cbr\u003eThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\n\nThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T20:52:44.604Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com/"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"tags": [
"release-notes"
],
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCrestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API.\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Non-Secure Access",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration. \u003cbr\u003e"
}
],
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47419",
"datePublished": "2025-05-06T20:52:44.604Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-07T14:03:57.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-47419",
"date": "2026-10-20",
"epss": "0.00295",
"percentile": "0.20819"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\n\nThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
},
{
"lang": "es",
"value": "La vulnerabilidad de transmisi\u00f3n de informaci\u00f3n confidencial en texto plano en Crestron Automate VX permite rastrear el tr\u00e1fico de red. El dispositivo permite el acceso a la interfaz web y la API a trav\u00e9s de puertos de red no seguros, lo que expone informaci\u00f3n confidencial, como las contrase\u00f1as de los usuarios. Este problema afecta a Automate VX desde la versi\u00f3n 5.6.8161.21536 hasta la 6.4.0.49."
}
],
"id": "CVE-2025-47419",
"lastModified": "2026-06-17T09:28:05.537",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-47419",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:47:55.617300Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-05-06T21:16:20.867",
"references": [
{
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"url": "https://security.crestron.com/"
},
{
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"sourceIdentifier": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T18:14:00+00:00",
"cve": "CVE-2025-47419",
"id": "CVE-2025-47419",
"initial_release_date": "2025-04-23T20:47:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Non-Secure Access",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-47419.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47419",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:47:55.617300Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T13:47:57.410Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T20:47:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\u003cbr\u003e\u003cbr\u003eThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\n\nThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T20:52:44.604Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com/"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"tags": [
"release-notes"
],
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCrestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API.\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Non-Secure Access",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration. \u003cbr\u003e"
}
],
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47419",
"datePublished": "2025-05-06T20:52:44.604Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-07T14:03:57.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.