GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2025-41004 (GCVE-0-2025-41004)

Vulnerability from cvelistv5 – Published: 2026-01-12 13:55 – Updated: 2026-01-12 14:20
VLAI
Title
Multiple vulnerabilities in Imaster products Open configuration options
Summary
Imaster's Patient Records Management System is vulnerable to SQL Injection in the endpoint ‘/projects/hospital/admin/complaints.php’ through the ‘id’ parameter.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-12 14:19 UTC
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Impacted products
Vendor Product Version CPE status
Imaster Patient Record Management System Affected: All versions
guessed Create a notification for this product.
Date Public
2026-01-12 13:31
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41004",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-12T14:19:59.030498Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-12T14:20:07.352Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Patient Record Management System",
          "vendor": "Imaster",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gonzalo Aguilar Garc\u00eda (6h4ack)"
        }
      ],
      "datePublic": "2026-01-12T13:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Imaster\u0027s Patient Records Management System is vulnerable to SQL Injection in the endpoint \u2018/projects/hospital/admin/complaints.php\u2019 through the \u2018id\u2019 parameter."
            }
          ],
          "value": "Imaster\u0027s Patient Records Management System is vulnerable to SQL Injection in the endpoint \u2018/projects/hospital/admin/complaints.php\u2019 through the \u2018id\u2019 parameter."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-12T13:55:28.273Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-imaster-products"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "No solution has been reported at this time.\u003cbr\u003e"
            }
          ],
          "value": "No solution has been reported at this time."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Multiple vulnerabilities in Imaster products Open configuration options",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2025-41004",
    "datePublished": "2026-01-12T13:55:28.273Z",
    "dateReserved": "2025-04-16T09:08:41.550Z",
    "dateUpdated": "2026-01-12T14:20:07.352Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-41004",
      "date": "2026-09-20",
      "epss": "0.00291",
      "percentile": "0.21941"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Patient Record Management System",
                "vendor": "Imaster",
                "versions": [
                  {
                    "status": "affected",
                    "version": "All versions"
                  }
                ]
              }
            ],
            "source": "cve-coordination@incibe.es"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Imaster\u0027s Patient Records Management System is vulnerable to SQL Injection in the endpoint \u2018/projects/hospital/admin/complaints.php\u2019 through the \u2018id\u2019 parameter."
          },
          {
            "lang": "es",
            "value": "El Sistema de Gesti\u00f3n de Registros de Pacientes de Imaster es vulnerable a inyecci\u00f3n SQL en el endpoint \u2018/projects/hospital/admin/complaints.php\u2019 a trav\u00e9s del par\u00e1metro \u2018id\u2019."
          }
        ],
        "id": "CVE-2025-41004",
        "lastModified": "2026-06-17T09:22:24.517",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cve-coordination@incibe.es",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-41004",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-12T14:19:59.030498Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-01-12T14:16:02.073",
        "references": [
          {
            "source": "cve-coordination@incibe.es",
            "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-imaster-products"
          }
        ],
        "sourceIdentifier": "cve-coordination@incibe.es",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-01-13T22:52:30+00:00",
      "cve": "CVE-2025-41004",
      "id": "CVE-2025-41004",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Multiple vulnerabilities in Imaster products Open configuration options",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-41004.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41004",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-12T14:19:59.030498Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-12T14:20:03.141Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Patient Record Management System",
              "vendor": "Imaster",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gonzalo Aguilar Garc\u00eda (6h4ack)"
            }
          ],
          "datePublic": "2026-01-12T13:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Imaster\u0027s Patient Records Management System is vulnerable to SQL Injection in the endpoint \u2018/projects/hospital/admin/complaints.php\u2019 through the \u2018id\u2019 parameter."
                }
              ],
              "value": "Imaster\u0027s Patient Records Management System is vulnerable to SQL Injection in the endpoint \u2018/projects/hospital/admin/complaints.php\u2019 through the \u2018id\u2019 parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-12T13:55:28.273Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-imaster-products"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "No solution has been reported at this time.\u003cbr\u003e"
                }
              ],
              "value": "No solution has been reported at this time."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Multiple vulnerabilities in Imaster products Open configuration options",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-41004",
        "datePublished": "2026-01-12T13:55:28.273Z",
        "dateReserved": "2025-04-16T09:08:41.550Z",
        "dateUpdated": "2026-01-12T14:20:07.352Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…