CVE-2025-37133 (GCVE-0-2025-37133)
Vulnerability from cvelistv5 – Published: 2025-10-14 16:54 – Updated: 2025-10-16 03:56
VLAI?
Title
Authenticated Command Injection Vulnerability in AOS-8 Controller/Mobility Conductor Web-Based Management Interface via the CLI Binaryalong with accounting controls for tracking and logging user activities and resource usage.
Summary
An authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system.
Severity ?
7.2 (High)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | ArubaOS (AOS) |
Affected:
10.7.0.0 , ≤ 10.7.1.1
(semver)
Affected: 10.4.0.0 , ≤ 10.4.1.8 (semver) Affected: 8.13.0.0 , ≤ 8.13.0.1 (semver) Affected: 8.12.0.0 , ≤ 8.12.0.5 (semver) Affected: 8.10.0.0 , ≤ 8.10.0.18 (semver) |
Credits
zzcentury from Ubisectech Sirius Team
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-37133",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-15T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T03:56:59.802Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ArubaOS (AOS)",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "10.7.1.1",
"status": "affected",
"version": "10.7.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "10.4.1.8",
"status": "affected",
"version": "10.4.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.13.0.1",
"status": "affected",
"version": "8.13.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.12.0.5",
"status": "affected",
"version": "8.12.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.10.0.18",
"status": "affected",
"version": "8.10.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zzcentury from Ubisectech Sirius Team"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system.\u003c/p\u003e"
}
],
"value": "An authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T16:54:36.030Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04957en_us\u0026docLocale=en_US"
}
],
"source": {
"advisory": "HPESBNW04957",
"discovery": "INTERNAL"
},
"title": "Authenticated Command Injection Vulnerability in AOS-8 Controller/Mobility Conductor Web-Based Management Interface via the CLI Binaryalong with accounting controls for tracking and logging user activities and resource usage.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2025-37133",
"datePublished": "2025-10-14T16:54:36.030Z",
"dateReserved": "2025-04-16T01:28:25.367Z",
"dateUpdated": "2025-10-16T03:56:59.802Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-37133\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2025-10-14T17:15:39.873\",\"lastModified\":\"2025-11-12T16:33:35.050\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.10.0.0\",\"versionEndExcluding\":\"8.10.0.19\",\"matchCriteriaId\":\"3D5F48C7-AD51-4641-9CBA-9DE9B516819E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.12.0.0\",\"versionEndExcluding\":\"8.12.0.6\",\"matchCriteriaId\":\"057AA8F5-FF66-44E9-8E06-D2B9E8B91AD2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.13.0.0\",\"versionEndExcluding\":\"8.13.1.0\",\"matchCriteriaId\":\"D4B066B5-D01B-43AE-B4DC-AF560D6B953C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.4.0.0\",\"versionEndExcluding\":\"10.4.1.9\",\"matchCriteriaId\":\"04F61E46-8412-4B8D-BE7B-EBF61BE52C54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.7.0.0\",\"versionEndExcluding\":\"10.7.2.1\",\"matchCriteriaId\":\"BEF8618F-C126-4F8F-951F-6D62FE8FAB22\"}]}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04957en_us\u0026docLocale=en_US\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-37133\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-14T19:17:23.807261Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-14T19:17:45.080Z\"}}], \"cna\": {\"title\": \"Authenticated Command Injection Vulnerability in AOS-8 Controller/Mobility Conductor Web-Based Management Interface via the CLI Binaryalong with accounting controls for tracking and logging user activities and resource usage.\", \"source\": {\"advisory\": \"HPESBNW04957\", \"discovery\": \"INTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"zzcentury from Ubisectech Sirius Team\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise (HPE)\", \"product\": \"ArubaOS (AOS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.7.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"10.7.1.1\"}, {\"status\": \"affected\", \"version\": \"10.4.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"10.4.1.8\"}, {\"status\": \"affected\", \"version\": \"8.13.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"8.13.0.1\"}, {\"status\": \"affected\", \"version\": \"8.12.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"8.12.0.5\"}, {\"status\": \"affected\", \"version\": \"8.10.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"8.10.0.18\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04957en_us\u0026docLocale=en_US\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn authenticated command injection vulnerability exists in the CLI binary of an AOS-8 Controller/Mobility Conductor operating system. Successful exploitation could allow an authenticated malicious actor to execute arbitrary commands as a privileged user on the underlying operating system.\u003c/p\u003e\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2025-10-14T16:54:36.030Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-37133\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-16T03:56:59.802Z\", \"dateReserved\": \"2025-04-16T01:28:25.367Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2025-10-14T16:54:36.030Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…