CVE-2025-3232 (GCVE-0-2025-3232)
Vulnerability from cvelistv5 – Published: 2025-12-24 19:55 – Updated: 2025-12-24 20:01
VLAI
EPSS
VEX
Title
Mitsubishi Electric Europe smartRTU Missing Authentication for Critical Function
Summary
A remote unauthenticated attacker may be able to bypass authentication
by utilizing a specific API route to execute arbitrary OS commands.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-12-24 20:01 UTC
CWE
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Mitsubishi Electric Europe | smartRTU |
Affected:
0 , ≤ 3.37
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3232",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-24T20:01:03.204248Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T20:01:27.393Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "smartRTU",
"vendor": "Mitsubishi Electric Europe",
"versions": [
{
"lessThanOrEqual": "3.37",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Noam Moshe of Claroty Team82 reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A remote unauthenticated attacker may be able to bypass authentication \nby utilizing a specific API route to execute arbitrary OS commands."
}
],
"value": "A remote unauthenticated attacker may be able to bypass authentication \nby utilizing a specific API route to execute arbitrary OS commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T19:55:43.172Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-105-09"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-105-09.json"
}
],
"source": {
"advisory": "ICSA-25-105-09",
"discovery": "EXTERNAL"
},
"title": "Mitsubishi Electric Europe smartRTU Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.\u003c/li\u003e\n\u003cli\u003eUse within a LAN and block access from untrusted networks and hosts through firewalls.\u003c/li\u003e\n\u003cli\u003eUse web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.\u003c/li\u003e\n\u003cli\u003eAllow web client access from trusted networks only.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eFor more information, please see \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information\"\u003eMitsubishi Electric Europe MEU_PSIRT_2025-3128\u003c/a\u003e\u0026nbsp;under the \"Vulnerability Information\" section.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Mitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:\n\n\n\n * Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.\n\n * Use within a LAN and block access from untrusted networks and hosts through firewalls.\n\n * Use web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.\n\n * Allow web client access from trusted networks only.\n\n\n\nFor more information, please see Mitsubishi Electric Europe MEU_PSIRT_2025-3128 https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information \u00a0under the \"Vulnerability Information\" section."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-3232",
"datePublished": "2025-12-24T19:55:43.172Z",
"dateReserved": "2025-04-03T16:06:31.944Z",
"dateUpdated": "2025-12-24T20:01:27.393Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-3232",
"date": "2026-11-02",
"epss": "0.00514",
"percentile": "0.43774"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "smartRTU",
"vendor": "Mitsubishi Electric Europe",
"versions": [
{
"lessThanOrEqual": "3.37",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote unauthenticated attacker may be able to bypass authentication \nby utilizing a specific API route to execute arbitrary OS commands."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado podr\u00eda eludir la autenticaci\u00f3n utilizando una ruta de API espec\u00edfica para ejecutar comandos arbitrarios del sistema operativo."
}
],
"id": "CVE-2025-3232",
"lastModified": "2026-10-07T13:10:00.713",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-3232",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-24T20:01:03.204248Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-12-24T20:15:55.233",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-105-09.json"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-105-09"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-12-25T20:18:43+00:00",
"cve": "CVE-2025-3232",
"id": "CVE-2025-3232",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Mitsubishi Electric Europe smartRTU Missing Authentication for Critical Function",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-3232.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3232",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-24T20:01:03.204248Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T20:01:22.167Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "smartRTU",
"vendor": "Mitsubishi Electric Europe",
"versions": [
{
"lessThanOrEqual": "3.37",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Noam Moshe of Claroty Team82 reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A remote unauthenticated attacker may be able to bypass authentication \nby utilizing a specific API route to execute arbitrary OS commands."
}
],
"value": "A remote unauthenticated attacker may be able to bypass authentication \nby utilizing a specific API route to execute arbitrary OS commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-24T19:55:43.172Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-105-09"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-105-09.json"
}
],
"source": {
"advisory": "ICSA-25-105-09",
"discovery": "EXTERNAL"
},
"title": "Mitsubishi Electric Europe smartRTU Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.\u003c/li\u003e\n\u003cli\u003eUse within a LAN and block access from untrusted networks and hosts through firewalls.\u003c/li\u003e\n\u003cli\u003eUse web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.\u003c/li\u003e\n\u003cli\u003eAllow web client access from trusted networks only.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eFor more information, please see \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information\"\u003eMitsubishi Electric Europe MEU_PSIRT_2025-3128\u003c/a\u003e\u0026nbsp;under the \"Vulnerability Information\" section.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Mitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:\n\n\n\n * Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.\n\n * Use within a LAN and block access from untrusted networks and hosts through firewalls.\n\n * Use web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.\n\n * Allow web client access from trusted networks only.\n\n\n\nFor more information, please see Mitsubishi Electric Europe MEU_PSIRT_2025-3128 https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information \u00a0under the \"Vulnerability Information\" section."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-3232",
"datePublished": "2025-12-24T19:55:43.172Z",
"dateReserved": "2025-04-03T16:06:31.944Z",
"dateUpdated": "2025-12-24T20:01:27.393Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.