CVE-2025-24938 (GCVE-0-2025-24938)
Vulnerability from cvelistv5 – Published: 2025-07-21 06:33 – Updated: 2025-07-23 18:39- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Nokia | WaveSuite NOC |
Affected:
WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12
Unaffected: WS-NOC 24.6 FP3 |
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-24938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-23T18:34:24.206505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-23T18:39:08.345Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WaveSuite NOC",
"vendor": "Nokia",
"versions": [
{
"status": "affected",
"version": "WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12"
},
{
"status": "unaffected",
"version": "WS-NOC 24.6 FP3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver.\n\nThe vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management."
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T06:33:56.306Z",
"orgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"shortName": "Nokia"
},
"references": [
{
"name": "Nokia Product Security Advisory",
"url": "https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24938/"
}
],
"title": "Insufficient Validation of Input while user creation",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"assignerShortName": "Nokia",
"cveId": "CVE-2025-24938",
"datePublished": "2025-07-21T06:33:56.306Z",
"dateReserved": "2025-01-29T07:19:18.312Z",
"dateUpdated": "2025-07-23T18:39:08.345Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-24938",
"date": "2026-11-26",
"epss": "0.00528",
"percentile": "0.38081"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "WaveSuite NOC",
"vendor": "Nokia",
"versions": [
{
"status": "affected",
"version": "WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12"
},
{
"status": "unaffected",
"version": "WS-NOC 24.6 FP3"
}
]
}
],
"source": "b48c3b8f-639e-4c16-8725-497bc411dad0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:23.6:*:*:*:*:*:*:*",
"matchCriteriaId": "557A2709-02CD-41F2-8D39-591C55DBC6CB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:23.12:*:*:*:*:*:*:*",
"matchCriteriaId": "3A4BF10D-5F41-49B7-AF3F-BAC85C6D8A15",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:24.6:-:*:*:*:*:*:*",
"matchCriteriaId": "9CA0E502-BCDA-4616-A4D2-0DBBC22163DA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver.\n\nThe vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management."
},
{
"lang": "es",
"value": "La aplicaci\u00f3n web permite que la entrada del usuario se transfiera sin filtrar a un comando que se ejecuta en el sistema operativo subyacente. Un atacante con privilegios elevados (administrador) a la aplicaci\u00f3n podr\u00eda ejecutar comandos en el sistema operativo en el contexto del servidor web. El componente vulnerable est\u00e1 vinculado a la pila de red y el conjunto de posibles atacantes se extiende a toda Internet. Tiene el potencial de inyectar comandos al crear un nuevo usuario desde la Administraci\u00f3n de Usuarios."
}
],
"id": "CVE-2025-24938",
"lastModified": "2026-06-17T08:59:51.990",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-24938",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-23T18:34:24.206505Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-07-21T07:15:24.130",
"references": [
{
"source": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"tags": [
"Vendor Advisory"
],
"url": "https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24938/"
}
],
"sourceIdentifier": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-07-23T07:03:44+00:00",
"cve": "CVE-2025-24938",
"id": "CVE-2025-24938",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Insufficient Validation of Input while user creation",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-24938.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-24938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-23T18:34:24.206505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-23T18:34:18.601Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WaveSuite NOC",
"vendor": "Nokia",
"versions": [
{
"status": "affected",
"version": "WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12"
},
{
"status": "unaffected",
"version": "WS-NOC 24.6 FP3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver.\n\nThe vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management."
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T06:33:56.306Z",
"orgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"shortName": "Nokia"
},
"references": [
{
"name": "Nokia Product Security Advisory",
"url": "https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24938/"
}
],
"title": "Insufficient Validation of Input while user creation",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"assignerShortName": "Nokia",
"cveId": "CVE-2025-24938",
"datePublished": "2025-07-21T06:33:56.306Z",
"dateReserved": "2025-01-29T07:19:18.312Z",
"dateUpdated": "2025-07-23T18:39:08.345Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.