CVE-2025-2399 (GCVE-0-2025-2399)
Vulnerability from cvelistv5 – Published: 2026-03-10 04:40 – Updated: 2026-03-10 17:32
VLAI?
Title
Denial of Service (DoS) Vulnerability in Mitsubishi Electric CNC Series
Summary
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683.
Severity ?
5.9 (Medium)
CWE
- CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T17:31:56.365207Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T17:32:04.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800V Series M800VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2051W000 versions BB and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800V Series M800VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2052W000 versions BB and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80V Series M80V",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2053W000 versions BB and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80V Series M80VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2054W000 versions BB and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800 Series M800W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2005W000 versions FM and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800 Series M800S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2006W000 versions FM and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80 Series M80",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2007W000 versions FM and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80 Series M80W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2008W000 versions FM and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC E80 Series E80",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2009W000 versions FM and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC C80 Series C80",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2036W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M750VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W002 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M720VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M730VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M720VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M730VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M750VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W002 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M70V Series M70V",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1018W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC E70 Series E70",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1022W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC Software Tools NC Trainer2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1802W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC Software Tools NC Trainer2 plus",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1803W000 all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683."
}
],
"value": "Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Denial of Service (DoS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1285",
"description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T04:40:00.599Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2025-022_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU95523788/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Denial of Service (DoS) Vulnerability in Mitsubishi Electric CNC Series",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2025-2399",
"datePublished": "2026-03-10T04:40:00.599Z",
"dateReserved": "2025-03-17T08:30:11.608Z",
"dateUpdated": "2026-03-10T17:32:04.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-2399\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2026-03-10T16:44:08.217\",\"lastModified\":\"2026-03-11T13:53:47.157\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1285\"}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU95523788/\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2025-022_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-2399\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-10T17:31:56.365207Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-03-10T17:31:59.976Z\"}}], \"cna\": {\"title\": \"Denial of Service (DoS) Vulnerability in Mitsubishi Electric CNC Series\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Denial of Service (DoS)\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M800V Series M800VW\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2051W000 versions BB and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M800V Series M800VS\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2052W000 versions BB and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M80V Series M80V\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2053W000 versions BB and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M80V Series M80VW\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2054W000 versions BB and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M800 Series M800W\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2005W000 versions FM and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M800 Series M800S\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2006W000 versions FM and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M80 Series M80\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2007W000 versions FM and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M80 Series M80W\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2008W000 versions FM and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC E80 Series E80\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2009W000 versions FM and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC C80 Series C80\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-2036W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M750VW\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1015W002 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M720VW\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1015W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M730VW\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1015W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M720VS\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1012W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M730VS\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1012W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M700V Series M750VS\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1012W002 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC M70V Series M70V\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1018W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC E70 Series E70\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1022W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC Software Tools NC Trainer2\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1802W000 all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Mitsubishi Electric CNC Software Tools NC Trainer2 plus\", \"versions\": [{\"status\": \"affected\", \"version\": \"System Number BND-1803W000 all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2025-022_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU95523788/\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1285\", \"description\": \"CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2026-03-10T04:40:00.599Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-2399\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-10T17:32:04.722Z\", \"dateReserved\": \"2025-03-17T08:30:11.608Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2026-03-10T04:40:00.599Z\", \"assignerShortName\": \"Mitsubishi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…