CVE-2025-15573 (GCVE-0-2025-15573)

Vulnerability from cvelistv5 – Published: 2026-02-12 10:39 – Updated: 2026-02-12 14:48
VLAI
Title
Missing Certificate Validation for Solax Power Pocket WiFi models MQTT Cloud Connection
Summary
The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-12 14:47 UTC
CWE
  • CWE-295 - Improper Certificate Validation
Assigner
SEC-VLab CNA under the mitre root
CNA scorecard B 83/100 over 23 records in the last 180 days details
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 9.4,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-15573",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-12T14:47:36.281880Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-12T14:48:08.160Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Pocket WiFi 3.0",
          "vendor": "SolaX Power",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c3.022.03"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Pocket WiFi+LAN",
          "vendor": "SolaX Power",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c1.009.02"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Pocket WiFi+4GM",
          "vendor": "SolaX Power",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c1.005.05"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Pocket WiFi+LAN 2.0",
          "vendor": "SolaX Power",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c006.06"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Pocket WiFi 4.0",
          "vendor": "SolaX Power",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c003.03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Stefan Viehb\u00f6ck, SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94 Adversary in the Middle (AiTM)"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-12T10:58:08.065Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "url": "https://r.sec-consult.com/solax"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\u003cbr\u003e\u003cbr\u003eAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\u003cbr\u003e1. Pocket WiFi 3.0 \u2013 (3.022.03)\u003cbr\u003e2. Pocket WiFi+LAN \u2013 (1.009.02)\u003cbr\u003e3. Pocket WiFi+4GM \u2013 (1.005.05)\u003cbr\u003e4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\u003cbr\u003e5. Pocket WiFi 4.0 \u2013 (003.03)\u003cbr\u003e\u003cbr\u003eThe vendor provided the following further information regarding EV Charger and Adapter Box:\u003cbr\u003e1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\u003cbr\u003e2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature.\u003cbr\u003e"
            }
          ],
          "value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\n\nAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\n1. Pocket WiFi 3.0 \u2013 (3.022.03)\n2. Pocket WiFi+LAN \u2013 (1.009.02)\n3. Pocket WiFi+4GM \u2013 (1.005.05)\n4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\n5. Pocket WiFi 4.0 \u2013 (003.03)\n\nThe vendor provided the following further information regarding EV Charger and Adapter Box:\n1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\n2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Missing Certificate Validation for Solax Power Pocket WiFi models MQTT Cloud Connection",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-15573",
    "datePublished": "2026-02-12T10:39:35.796Z",
    "dateReserved": "2026-02-09T09:43:49.723Z",
    "dateUpdated": "2026-02-12T14:48:08.160Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-15573",
      "date": "2026-11-13",
      "epss": "0.00226",
      "percentile": "0.13431"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Pocket WiFi 3.0",
                "vendor": "SolaX Power",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003c3.022.03"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Pocket WiFi+LAN",
                "vendor": "SolaX Power",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003c1.009.02"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Pocket WiFi+4GM",
                "vendor": "SolaX Power",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003c1.005.05"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Pocket WiFi+LAN 2.0",
                "vendor": "SolaX Power",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003c006.06"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Pocket WiFi 4.0",
                "vendor": "SolaX Power",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003c003.03"
                  }
                ]
              }
            ],
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices."
          },
          {
            "lang": "es",
            "value": "Los dispositivos afectados no validan el certificado del servidor al conectarse al servidor MQTTS de SolaX Cloud alojado en Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). Esto permite a los atacantes en una posici\u00f3n de man-in-the-middle actuar como el servidor MQTT leg\u00edtimo y emitir comandos arbitrarios a los dispositivos."
          }
        ],
        "id": "CVE-2025-15573",
        "lastModified": "2026-06-17T08:38:03.397",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.5,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-15573",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-12T14:47:36.281880Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-02-12T11:15:47.780",
        "references": [
          {
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "url": "https://r.sec-consult.com/solax"
          }
        ],
        "sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-295"
              }
            ],
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-02-13T13:22:29+00:00",
      "cve": "CVE-2025-15573",
      "id": "CVE-2025-15573",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Missing Certificate Validation for Solax Power Pocket WiFi models MQTT Cloud Connection",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-15573.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 9.4,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-15573",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-12T14:47:36.281880Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-12T14:47:48.711Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Pocket WiFi 3.0",
              "vendor": "SolaX Power",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c3.022.03"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pocket WiFi+LAN",
              "vendor": "SolaX Power",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c1.009.02"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pocket WiFi+4GM",
              "vendor": "SolaX Power",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c1.005.05"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pocket WiFi+LAN 2.0",
              "vendor": "SolaX Power",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c006.06"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Pocket WiFi 4.0",
              "vendor": "SolaX Power",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c003.03"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Stefan Viehb\u00f6ck, SEC Consult Vulnerability Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices.\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The affected devices do not validate the server certificate when connecting to the SolaX Cloud MQTTS server hosted in the Alibaba Cloud (mqtt001.solaxcloud.com, TCP 8883). This allows attackers in a man-in-the-middle position to act as the legitimate MQTT server and issue arbitrary commands to devices."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-94",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-94 Adversary in the Middle (AiTM)"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-295",
                  "description": "CWE-295 Improper Certificate Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-12T10:58:08.065Z",
            "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "shortName": "SEC-VLab"
          },
          "references": [
            {
              "url": "https://r.sec-consult.com/solax"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\u003cbr\u003e\u003cbr\u003eAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\u003cbr\u003e1. Pocket WiFi 3.0 \u2013 (3.022.03)\u003cbr\u003e2. Pocket WiFi+LAN \u2013 (1.009.02)\u003cbr\u003e3. Pocket WiFi+4GM \u2013 (1.005.05)\u003cbr\u003e4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\u003cbr\u003e5. Pocket WiFi 4.0 \u2013 (003.03)\u003cbr\u003e\u003cbr\u003eThe vendor provided the following further information regarding EV Charger and Adapter Box:\u003cbr\u003e1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\u003cbr\u003e2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature.\u003cbr\u003e"
                }
              ],
              "value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\n\nAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\n1. Pocket WiFi 3.0 \u2013 (3.022.03)\n2. Pocket WiFi+LAN \u2013 (1.009.02)\n3. Pocket WiFi+4GM \u2013 (1.005.05)\n4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\n5. Pocket WiFi 4.0 \u2013 (003.03)\n\nThe vendor provided the following further information regarding EV Charger and Adapter Box:\n1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\n2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Certificate Validation for Solax Power Pocket WiFi models MQTT Cloud Connection",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "assignerShortName": "SEC-VLab",
        "cveId": "CVE-2025-15573",
        "datePublished": "2026-02-12T10:39:35.796Z",
        "dateReserved": "2026-02-09T09:43:49.723Z",
        "dateUpdated": "2026-02-12T14:48:08.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.