CVE-2024-7986 (GCVE-0-2024-7986)
Vulnerability from cvelistv5 – Published: 2024-08-23 11:51 – Updated: 2024-08-28 16:21- CWE-732 - Incorrect Permission Assignment for Critical Resource
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | ThinManager® ThinServer™ |
Affected:
11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T16:20:54.169556Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T16:21:02.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager\u00ae ThinServer\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"datePublic": "2024-08-22T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability exists in the Rockwell Automation\u0026nbsp;\u003c/span\u003eThinManager\u00ae ThinServer\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ethat allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer\u2122 service to read arbitrary files by creating a junction that points to the target directory.\u003c/span\u003e"
}
],
"value": "A vulnerability exists in the Rockwell Automation\u00a0ThinManager\u00ae ThinServer\u00a0that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer\u2122 service to read arbitrary files by creating a junction that points to the target directory."
}
],
"impacts": [
{
"capecId": "CAPEC-576",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-576 Group Permission Footprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T11:51:55.080Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in software version\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in software version\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eThinManager\u00ae ThinServer\u2122\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.0-11.1.7\u003cbr\u003e11.2.0-11.2.8\u003cbr\u003e12.0.0-12.0.6\u003cbr\u003e12.1.0-12.1.7\u003cbr\u003e13.0.0-13.0.4\u003cbr\u003e13.1.0-13.1.2\u003cbr\u003e13.2.0-13.2.1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.8\u003c/p\u003e\u003cp\u003e11.2.9\u003c/p\u003e\u003cp\u003e12.0.7\u003c/p\u003e\u003cp\u003e12.1.8\u003c/p\u003e\u003cp\u003e13.0.5\u003c/p\u003e\u003cp\u003e13.1.3\u003c/p\u003e\u003cp\u003e13.2.2\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Affected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager\u00ae ThinServer\u2122\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "SD1692",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation ThinManager\u00ae ThinServer\u2122 Information Disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7986",
"datePublished": "2024-08-23T11:51:55.080Z",
"dateReserved": "2024-08-19T20:06:24.873Z",
"dateUpdated": "2024-08-28T16:21:02.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-7986",
"date": "2026-11-16",
"epss": "0.00559",
"percentile": "0.47121"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ThinManager\u00ae ThinServer\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2BC59B57-F8F5-4979-826B-EAA0A8456B2A",
"versionEndExcluding": "11.1.8",
"versionStartIncluding": "11.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "79481998-C98B-4486-A2DC-C4DE324DCA10",
"versionEndExcluding": "11.2.9",
"versionStartIncluding": "11.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFD553E2-EB04-4D97-AD70-2175933E3DCD",
"versionEndExcluding": "12.0.7",
"versionStartIncluding": "12.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC5BBCD2-0C47-4B48-81DD-D56D5677BFA0",
"versionEndExcluding": "12.1.8",
"versionStartIncluding": "12.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EEDB253-45FB-4722-994A-E0EF00C7F405",
"versionEndExcluding": "13.0.5",
"versionStartIncluding": "13.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F2FB9C58-1AAF-46CB-BBB5-909223EE5572",
"versionEndExcluding": "13.1.3",
"versionStartIncluding": "13.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BB3AA59A-9CA4-4CD0-981C-B974A94BAC30",
"versionEndExcluding": "13.2.2",
"versionStartIncluding": "13.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the Rockwell Automation\u00a0ThinManager\u00ae ThinServer\u00a0that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer\u2122 service to read arbitrary files by creating a junction that points to the target directory."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en Rockwell Automation ThinManager\u00ae ThinServer que permite a un actor de amenazas revelar informaci\u00f3n confidencial. Un actor de amenazas puede explotar esta vulnerabilidad abusando del servicio ThinServer\u2122 para leer archivos arbitrarios creando una uni\u00f3n que apunte al directorio de destino."
}
],
"id": "CVE-2024-7986",
"lastModified": "2026-06-17T08:21:37.187",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-7986",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T16:20:54.169556Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-08-23T12:15:03.920",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T21:38:20+00:00",
"cve": "CVE-2024-7986",
"id": "CVE-2024-7986",
"initial_release_date": "2024-08-22T13:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation ThinManager\u00ae ThinServer\u2122 Information Disclosure",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-7986.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T16:20:54.169556Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T16:20:59.124Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager\u00ae ThinServer\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"datePublic": "2024-08-22T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability exists in the Rockwell Automation\u0026nbsp;\u003c/span\u003eThinManager\u00ae ThinServer\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ethat allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer\u2122 service to read arbitrary files by creating a junction that points to the target directory.\u003c/span\u003e"
}
],
"value": "A vulnerability exists in the Rockwell Automation\u00a0ThinManager\u00ae ThinServer\u00a0that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer\u2122 service to read arbitrary files by creating a junction that points to the target directory."
}
],
"impacts": [
{
"capecId": "CAPEC-576",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-576 Group Permission Footprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T11:51:55.080Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in software version\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in software version\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eThinManager\u00ae ThinServer\u2122\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.0-11.1.7\u003cbr\u003e11.2.0-11.2.8\u003cbr\u003e12.0.0-12.0.6\u003cbr\u003e12.1.0-12.1.7\u003cbr\u003e13.0.0-13.0.4\u003cbr\u003e13.1.0-13.1.2\u003cbr\u003e13.2.0-13.2.1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.8\u003c/p\u003e\u003cp\u003e11.2.9\u003c/p\u003e\u003cp\u003e12.0.7\u003c/p\u003e\u003cp\u003e12.1.8\u003c/p\u003e\u003cp\u003e13.0.5\u003c/p\u003e\u003cp\u003e13.1.3\u003c/p\u003e\u003cp\u003e13.2.2\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Affected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager\u00ae ThinServer\u2122\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "SD1692",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation ThinManager\u00ae ThinServer\u2122 Information Disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7986",
"datePublished": "2024-08-23T11:51:55.080Z",
"dateReserved": "2024-08-19T20:06:24.873Z",
"dateUpdated": "2024-08-28T16:21:02.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.