CVE-2024-7507 (GCVE-0-2024-7507)
Vulnerability from cvelistv5 – Published: 2024-08-14 19:35 – Updated: 2024-08-15 14:37- CWE-20 - Improper Input Validation
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | CompactLogix 5380 (5069 – L3z) |
Affected:
28.011
|
guessed | |
| Rockwell Automation | ControlLogix® 5580 (1756 –L8z) |
Affected:
28.011
|
guessed | |
| Rockwell Automation | GuardLogix 5580 (1756-L8z) |
Affected:
28.011
|
guessed | |
| Rockwell Automation | Compact GuardLogix 5380 (5069- L3zS2) |
Affected:
28.011
|
guessed | |
| Rockwell Automation | CompactLogix 5480 (5069-L4) |
Affected:
28.011
|
guessed | |
| rockwellautomation | controllogix_5380_firmware |
Affected:
28.011
cpe:2.3:o:rockwellautomation:controllogix_5380_firmware:28.011:*:*:*:*:*:*:* |
||
| rockwellautomation | controllogix_5580_firmware |
Affected:
28.011
cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:28.011:*:*:*:*:*:*:* |
||
| rockwellautomation | guardlogix_5580_firmware |
Affected:
28.011
cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:28.011:*:*:*:*:*:*:* |
||
| rockwellautomation | compact_guardlogix_5380_firmware |
Affected:
28.011
cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:28.011:*:*:*:*:*:*:* |
||
| rockwellautomation | compactlogix_5480_firmware |
Affected:
28.011
cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:28.011:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix_5480_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7507",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T14:32:59.595579Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T14:37:58.421Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380 (5069 \u2013 L3z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580 (1756 \u2013L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580 (1756-L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380 (5069- L3zS2)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480 (5069-L4)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"datePublic": "2024-08-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-7507 IMPACT\u003c/u\u003e\u003c/b\u003e\u003c/p\u003e\u003cp\u003eA denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.\u003c/p\u003e"
}
],
"value": "CVE-2024-7507 IMPACT\n\nA denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T19:35:55.326Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpgrade to:\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ev36.011, v35.013, v34.014\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\n\n\u003cbr\u003e\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "Upgrade to:\u00a0\n\nv36.011, v35.013, v34.014"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Controller Denial-of-Service Vulnerability via Input Validation",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRestrict communication to CIP object 103 (0x67)\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Restrict communication to CIP object 103 (0x67)"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7507",
"datePublished": "2024-08-14T19:35:55.326Z",
"dateReserved": "2024-08-05T20:04:40.970Z",
"dateUpdated": "2024-08-15T14:37:58.421Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-7507",
"date": "2026-11-16",
"epss": "0.005",
"percentile": "0.4338"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380 (5069 \u2013 L3z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580 (1756 \u2013L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580 (1756-L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380 (5069- L3zS2)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480 (5069-L4)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix_5480_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AABBF4EF-9F0E-432D-A535-F74402CFD05D",
"versionEndExcluding": "34.014",
"versionStartIncluding": "28.011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "305CDBFF-404A-45F5-A391-1B18F446D1B8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E5B18F7F-80AB-4146-9D65-B1DB4C2FAA8D",
"versionEndExcluding": "34.014",
"versionStartIncluding": "28.011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "A29D3775-CAB3-45CF-96CE-71D0672C7E37",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC2E9A2F-AFC7-442D-88FC-C3217ABB560E",
"versionEndExcluding": "34.014",
"versionStartIncluding": "31.011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "64CAC9B1-19E5-44BB-B814-DDA98B7290E4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
"matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "560A9F50-DBCF-48CF-856B-BE061C490697",
"versionEndExcluding": "34.014",
"versionStartIncluding": "31.011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A5DA9B-E1CA-45FF-8A9B-60B1E506F981",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E594CDF6-0582-4D5C-B6AA-C8A2E752E29F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3631A2E0-00BA-4DF2-94C2-6906B9A3E941",
"versionEndExcluding": "34.014",
"versionStartIncluding": "32.013",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "ABE90277-EB8A-4ECE-A573-C1814F35CB47",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B82D842C-0930-41AA-83CD-5F235771AE4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8C025589-66EE-40EF-8CE6-9A7B76D74BF4",
"versionEndExcluding": "34.014",
"versionStartIncluding": "32.011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:35.011:*:*:*:*:*:*:*",
"matchCriteriaId": "61F8EA3B-C51C-4CB1-9BB3-017577DC6684",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
"matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CVE-2024-7507 IMPACT\n\nA denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller."
},
{
"lang": "es",
"value": " CVE-2024-7507 IMPACT Existe una vulnerabilidad de denegaci\u00f3n de servicio en los productos afectados. Esta vulnerabilidad ocurre cuando se recibe un mensaje PCCC con formato incorrecto, lo que provoca un fallo en el controlador."
}
],
"id": "CVE-2024-7507",
"lastModified": "2026-06-17T08:20:20.327",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-7507",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T14:32:59.595579Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-08-14T20:15:12.900",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:01:55+00:00",
"cve": "CVE-2024-7507",
"id": "CVE-2024-7507",
"initial_release_date": "2024-08-13T13:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Controller Denial-of-Service Vulnerability via Input Validation",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-7507.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5380_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"cpes": [
"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:28.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix_5480_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7507",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T14:32:59.595579Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T14:37:52.323Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380 (5069 \u2013 L3z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580 (1756 \u2013L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580 (1756-L8z)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380 (5069- L3zS2)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480 (5069-L4)",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "28.011"
}
]
}
],
"datePublic": "2024-08-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-7507 IMPACT\u003c/u\u003e\u003c/b\u003e\u003c/p\u003e\u003cp\u003eA denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.\u003c/p\u003e"
}
],
"value": "CVE-2024-7507 IMPACT\n\nA denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T19:35:55.326Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpgrade to:\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ev36.011, v35.013, v34.014\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\n\n\u003cbr\u003e\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "Upgrade to:\u00a0\n\nv36.011, v35.013, v34.014"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Controller Denial-of-Service Vulnerability via Input Validation",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRestrict communication to CIP object 103 (0x67)\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Restrict communication to CIP object 103 (0x67)"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7507",
"datePublished": "2024-08-14T19:35:55.326Z",
"dateReserved": "2024-08-05T20:04:40.970Z",
"dateUpdated": "2024-08-15T14:37:58.421Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Workarounds
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.