CVE-2024-6436 (GCVE-0-2024-6436)
Vulnerability from cvelistv5 – Published: 2024-09-27 19:45 – Updated: 2024-10-03 13:56- CWE-20 - Improper Input Validation
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | SequenceManager™ |
Affected:
<2.0
|
guessed | |
| rockwellautomation | sequencemanager |
Affected:
0 , < 2.0
(custom)
cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sequencemanager",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-03T13:54:44.194684Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-03T13:56:51.490Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SequenceManager\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c2.0"
}
]
}
],
"datePublic": "2024-09-27T19:36:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAdditionally, if exploited, there could be a loss of view for the downstream equipment sequences in the c\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eontroller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\u003c/span\u003e"
}
],
"value": "An input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-27T19:45:04.984Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cul\u003e\u003cli\u003eCorrected in versions v2.0 or later.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\n\n\u003cp\u003eUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "* Corrected in versions v2.0 or later.\u00a0\n * \n\nUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "1679",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation Input Validation Vulnerability exists in the SequenceManager\u2122 Server",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-6436",
"datePublished": "2024-09-27T19:45:04.984Z",
"dateReserved": "2024-07-01T21:06:42.745Z",
"dateUpdated": "2024-10-03T13:56:51.490Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-6436",
"date": "2026-11-15",
"epss": "0.02055",
"percentile": "0.81597"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SequenceManager\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c2.0"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sequencemanager",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "451FED36-BF02-4149-81BA-28B3C6BB2D89",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de validaci\u00f3n de entrada en Rockwell Automation Sequence Manager\u2122 que podr\u00eda permitir que un usuario malintencionado env\u00ede paquetes malformados al servidor y provoque una condici\u00f3n de denegaci\u00f3n de servicio. Si se explota, el dispositivo dejar\u00eda de responder y ser\u00eda necesario reiniciarlo manualmente para recuperarlo. Adem\u00e1s, si se explota, podr\u00eda perderse la vista de las secuencias de equipos posteriores en el controlador. Los usuarios no podr\u00edan ver el estado ni ordenar las secuencias de equipos, pero la secuencia de equipos seguir\u00eda ejecut\u00e1ndose sin interrupciones."
}
],
"id": "CVE-2024-6436",
"lastModified": "2026-06-17T08:18:00.610",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-6436",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-03T13:54:44.194684Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-09-27T20:15:06.043",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:03:17+00:00",
"cve": "CVE-2024-6436",
"id": "CVE-2024-6436",
"initial_release_date": "2024-09-27T19:36:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation Input Validation Vulnerability exists in the SequenceManager\u2122 Server",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-6436.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:sequencemanager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sequencemanager",
"vendor": "rockwellautomation",
"versions": [
{
"lessThan": "2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-03T13:54:44.194684Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-03T13:56:45.951Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SequenceManager\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c2.0"
}
]
}
],
"datePublic": "2024-09-27T19:36:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAdditionally, if exploited, there could be a loss of view for the downstream equipment sequences in the c\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eontroller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.\u003c/span\u003e"
}
],
"value": "An input validation vulnerability exists in the Rockwell Automation Sequence Manager\u2122 which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-27T19:45:04.984Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1679.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cul\u003e\u003cli\u003eCorrected in versions v2.0 or later.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\n\n\u003cp\u003eUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "* Corrected in versions v2.0 or later.\u00a0\n * \n\nUsers using the affected software who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "1679",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation Input Validation Vulnerability exists in the SequenceManager\u2122 Server",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-6436",
"datePublished": "2024-09-27T19:45:04.984Z",
"dateReserved": "2024-07-01T21:06:42.745Z",
"dateUpdated": "2024-10-03T13:56:51.490Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.