CVE-2024-50313 (GCVE-0-2024-50313)

Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2025-08-27 21:33
VLAI
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-12 14:16 UTC
CWE
  • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 100 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Siemens Mendix Runtime V10 Affected: 0 , < V10.16.0 (custom)
guessed Create a notification for this product.
Siemens Mendix Runtime V10.12 Affected: 0 , < V10.12.7 (custom)
guessed Create a notification for this product.
Siemens Mendix Runtime V10.6 Affected: 0 , < V10.6.15 (custom)
guessed Create a notification for this product.
Siemens Mendix Runtime V8 Affected: 0 , < * (custom)
guessed Create a notification for this product.
Siemens Mendix Runtime V9 Affected: 0 , < V9.24.29 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:05.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.16.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-362",
              "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:45.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50313",
    "datePublished": "2024-11-12T12:49:54.803Z",
    "dateReserved": "2024-10-22T15:35:51.132Z",
    "dateUpdated": "2025-08-27T21:33:05.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-50313",
      "date": "2026-11-07",
      "epss": "0.00275",
      "percentile": "0.20061"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Mendix Runtime V10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V10.16.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Mendix Runtime V10.12",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V10.12.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Mendix Runtime V10.6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V10.6.15",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Mendix Runtime V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Mendix Runtime V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V9.24.29",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "productcert@siemens.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F6087752-F90F-4674-8C24-A4D1EB5CB7AB",
                    "versionEndExcluding": "9.24.29",
                    "versionStartIncluding": "8.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "774E44F6-A7DA-4903-9AA5-B41D4AC39B5F",
                    "versionEndExcluding": "10.6.15",
                    "versionStartIncluding": "10.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4B78566A-6B9D-4C40-9834-D16410CEE04F",
                    "versionEndExcluding": "10.12.7",
                    "versionStartIncluding": "10.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "243DDDBE-BA70-44F9-B363-A0DC51595876",
                    "versionEndExcluding": "10.16.0",
                    "versionStartIncluding": "10.13.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en Mendix Runtime V10 (todas las versiones anteriores a la V10.16.0, solo si la aplicaci\u00f3n utiliza el mecanismo de autenticaci\u00f3n b\u00e1sica), Mendix Runtime V10.12 (todas las versiones anteriores a la V10.12.7, solo si la aplicaci\u00f3n utiliza el mecanismo de autenticaci\u00f3n b\u00e1sica), Mendix Runtime V10.6 (todas las versiones anteriores a la V10.6.15, solo si la aplicaci\u00f3n utiliza el mecanismo de autenticaci\u00f3n b\u00e1sica), Mendix Runtime V8 (todas las versiones), Mendix Runtime V9 (todas las versiones anteriores a la V9.24.29, solo si la aplicaci\u00f3n utiliza el mecanismo de autenticaci\u00f3n b\u00e1sica). La implementaci\u00f3n de autenticaci\u00f3n b\u00e1sica de las aplicaciones afectadas contiene una vulnerabilidad de condici\u00f3n de ejecuci\u00f3n que podr\u00eda permitir a atacantes remotos no autenticados eludir las medidas de bloqueo de cuentas predeterminadas."
          }
        ],
        "id": "CVE-2024-50313",
        "lastModified": "2026-06-17T08:04:11.790",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 1.4,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.2,
              "impactScore": 2.5,
              "source": "nvd@nist.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.2,
              "impactScore": 2.5,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-11-12T13:15:11.910",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-362"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-08-12T12:29:32+00:00",
      "cve": "CVE-2024-50313",
      "id": "CVE-2024-50313",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-50313",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-50313.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-50313",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T14:16:20.945053Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-27T17:50:46.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.16.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V10.12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.12.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V10.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.6.15",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.24.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-362",
                  "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-12T11:16:45.329Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-50313",
        "datePublished": "2024-11-12T12:49:54.803Z",
        "dateReserved": "2024-10-22T15:35:51.132Z",
        "dateUpdated": "2025-08-27T21:33:05.238Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.