CVE-2024-4511 (GCVE-0-2024-4511)

Vulnerability from cvelistv5 – Published: 2024-05-06 01:00 – Updated: 2024-08-01 20:40
VLAI
Title
Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow
Summary
A vulnerability classified as critical has been found in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4. This affects an unknown part of the component Message Handler. The manipulation leads to buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263115. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
Impacted products
Credits
isZzzzz (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:shanghai_sunfill_automation:BACnet_server_HMI1002-ARM:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "BACnet_server_HMI1002-ARM",
            "vendor": "shanghai_sunfill_automation",
            "versions": [
              {
                "lessThanOrEqual": "2.0.4",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4511",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-06T19:41:20.366487Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:54:17.481Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:40:47.320Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-263115 | Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.263115"
          },
          {
            "name": "VDB-263115 | CTI Indicators (IOB, IOC)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.263115"
          },
          {
            "name": "Submit #323832 | Shanghai Sunfull Automation Co., LTD. HMI1002-ARM Firmware Revision: 2.0.4 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.323832"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Message Handler"
          ],
          "product": "BACnet Server HMI1002-ARM",
          "vendor": "Shanghai Sunfull Automation",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.4"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "isZzzzz (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4. This affects an unknown part of the component Message Handler. The manipulation leads to buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263115. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4 entdeckt. Sie wurde als kritisch eingestuft. Es betrifft eine unbekannte Funktion der Komponente Message Handler. Mittels Manipulieren mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-06T01:00:05.434Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-263115 | Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.263115"
        },
        {
          "name": "VDB-263115 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.263115"
        },
        {
          "name": "Submit #323832 | Shanghai Sunfull Automation Co., LTD. HMI1002-ARM Firmware Revision: 2.0.4 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.323832"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-05-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-05-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-05-05T09:11:00.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4511",
    "datePublished": "2024-05-06T01:00:05.434Z",
    "dateReserved": "2024-05-05T07:05:38.922Z",
    "dateUpdated": "2024-08-01T20:40:47.320Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-4511",
      "date": "2026-05-28",
      "epss": "0.00058",
      "percentile": "0.18375"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-4511\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-05-06T01:15:48.940\",\"lastModified\":\"2024-11-21T09:42:59.453\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical has been found in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4. This affects an unknown part of the component Message Handler. The manipulation leads to buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263115. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad ha sido encontrada en Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4 y clasificada como cr\u00edtica. Una parte desconocida del componente Message Handler afecta a una parte desconocida. La manipulaci\u00f3n provoca un desbordamiento del b\u00fafer. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-263115. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":5.8,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.5,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.263115\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.263115\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.323832\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://vuldb.com/?ctiid.263115\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://vuldb.com/?id.263115\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://vuldb.com/?submit.323832\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.263115\", \"name\": \"VDB-263115 | Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow\", \"tags\": [\"vdb-entry\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.263115\", \"name\": \"VDB-263115 | CTI Indicators (IOB, IOC)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.323832\", \"name\": \"Submit #323832 | Shanghai Sunfull Automation Co., LTD. HMI1002-ARM Firmware Revision: 2.0.4 Buffer Overflow\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf\", \"tags\": [\"related\", \"x_transferred\"]}, {\"url\": \"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:40:47.320Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-4511\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-06T19:41:20.366487Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:shanghai_sunfill_automation:BACnet_server_HMI1002-ARM:-:*:*:*:*:*:*:*\"], \"vendor\": \"shanghai_sunfill_automation\", \"product\": \"BACnet_server_HMI1002-ARM\", \"versions\": [{\"status\": \"affected\", \"version\": \"-\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.0.4\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-06T19:43:29.003Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"isZzzzz (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 5.8, \"vectorString\": \"AV:A/AC:L/Au:N/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"Shanghai Sunfull Automation\", \"modules\": [\"Message Handler\"], \"product\": \"BACnet Server HMI1002-ARM\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.4\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-05-05T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-05-05T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-05-05T09:11:00.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.263115\", \"name\": \"VDB-263115 | Shanghai Sunfull Automation BACnet Server HMI1002-ARM Message buffer overflow\", \"tags\": [\"vdb-entry\"]}, {\"url\": \"https://vuldb.com/?ctiid.263115\", \"name\": \"VDB-263115 | CTI Indicators (IOB, IOC)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.323832\", \"name\": \"Submit #323832 | Shanghai Sunfull Automation Co., LTD. HMI1002-ARM Firmware Revision: 2.0.4 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/HMI1002-ARM%20apply.pdf\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/isZzzz/HMI1002-ARM-Gateway-Document/blob/main/sunfull_bug.pcapng\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical has been found in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4. This affects an unknown part of the component Message Handler. The manipulation leads to buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263115. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4 entdeckt. Sie wurde als kritisch eingestuft. Es betrifft eine unbekannte Funktion der Komponente Message Handler. Mittels Manipulieren mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"CWE-120 Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-05-06T01:00:05.434Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-4511\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:40:47.320Z\", \"dateReserved\": \"2024-05-05T07:05:38.922Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-05-06T01:00:05.434Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…