CVE-2024-39585 (GCVE-0-2024-39585)
Vulnerability from cvelistv5 – Published: 2024-09-06 04:18 – Updated: 2024-09-17 01:50
VLAI?
Summary
Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure.
Severity ?
7.9 (High)
CWE
- CWE-259 - Use of Hard-coded Password
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | SmartFabric OS10 Software |
Affected:
10.5.6.x
Affected: 10.5.5.4 , ≤ 10.5.5.10 (semver) |
Credits
Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39585",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-06T13:03:12.365737Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-06T13:03:24.393Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SmartFabric OS10 Software",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "10.5.6.x"
},
{
"lessThanOrEqual": "10.5.5.10",
"status": "affected",
"version": "10.5.5.4",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue."
}
],
"datePublic": "2024-09-05T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure."
}
],
"value": "Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.9,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259: Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-17T01:50:13.135Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000228355/dsa-2024-376-security-update-for-dell-networking-os10-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-39585",
"datePublished": "2024-09-06T04:18:27.225Z",
"dateReserved": "2024-06-26T02:16:08.993Z",
"dateUpdated": "2024-09-17T01:50:13.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2024-39585\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-09-06T05:15:13.590\",\"lastModified\":\"2024-09-17T02:15:49.397\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure.\"},{\"lang\":\"es\",\"value\":\"El software Dell SmartFabric OS10, versiones 10.5.5.4 a 10.5.5.10 y 10.5.6.x, contiene una vulnerabilidad de uso de contrase\u00f1as codificadas. Un atacante con pocos privilegios y acceso remoto podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la falsificaci\u00f3n de solicitudes del lado del cliente y la divulgaci\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H\",\"baseScore\":7.9,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-259\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.5.5.4\",\"versionEndIncluding\":\"10.5.5.10\",\"matchCriteriaId\":\"2C6EF932-BB59-4B2D-9C4B-83C915A81268\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.5.6.0\",\"versionEndExcluding\":\"10.5.6.4\",\"matchCriteriaId\":\"7863BC08-9CB1-4269-A490-717834BD3B40\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000228355/dsa-2024-376-security-update-for-dell-networking-os10-vulnerability\",\"source\":\"security_alert@emc.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-39585\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-06T13:03:12.365737Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-06T13:03:19.145Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"SmartFabric OS10 Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.5.6.x\"}, {\"status\": \"affected\", \"version\": \"10.5.5.4\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"10.5.5.10\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-09-05T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000228355/dsa-2024-376-security-update-for-dell-networking-os10-vulnerability\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-259\", \"description\": \"CWE-259: Use of Hard-coded Password\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-09-17T01:50:13.135Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-39585\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-17T01:50:13.135Z\", \"dateReserved\": \"2024-06-26T02:16:08.993Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-09-06T04:18:27.225Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…