CVE-2024-3596 (GCVE-0-2024-3596)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:02 – Updated: 2026-05-12 11:30
VLAI
EPSS
Title
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Severity
9 (Critical)
CWE
Assigner
References
8 references
Credits
Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rfc",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T03:55:37.141738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-04T21:05:25.373Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:52.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
},
{
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"tags": [
"x_transferred"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.blastradius.fail/"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"url": "https://www.kb.cert.org/vuls/id/456537"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "CPC80 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.51",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CPCI85 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q200 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Powerlink IP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM CROSSBOW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600F",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600FNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000ANC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000H",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000HNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GPNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG907R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG908C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG909R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG910C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2428P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3 3G-Router (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X304-2FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X306-1LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1 FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1-2LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 SC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC316-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC416-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC424-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC432",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCH328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM324",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216PoE EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM AK 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM BC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge (Classic)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge Applications for SICAM 8 Platform",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridPass",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM TM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICORE Base system",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.20.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC INS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0 SP2 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 - CP200 Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:30:39.787Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "RFC",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"
}
],
"descriptions": [
{
"lang": "en",
"value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-328: Use of Weak Hash",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T17:29:16.788Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"url": "https://www.blastradius.fail/"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT for SIPROTEC, SICAM and related product",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.",
"x_generator": {
"engine": "VINCE 3.0.4",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-3596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-3596",
"datePublished": "2024-07-09T12:02:53.001Z",
"dateReserved": "2024-04-10T15:09:45.391Z",
"dateUpdated": "2026-05-12T11:30:39.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-3596",
"date": "2026-05-29",
"epss": "0.19769",
"percentile": "0.95545"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-3596\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2024-07-09T12:15:20.700\",\"lastModified\":\"2026-05-12T12:16:57.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.\"},{\"lang\":\"es\",\"value\":\"El protocolo RADIUS seg\u00fan RFC 2865 es susceptible a ataques de falsificaci\u00f3n por parte de un atacante local que puede modificar cualquier respuesta v\u00e1lida (acceso-aceptaci\u00f3n, acceso-rechazo o acceso-desaf\u00edo) a cualquier otra respuesta utilizando un ataque de colisi\u00f3n de prefijo elegido contra la firma del autenticador de respuesta MD5. .\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":6.0},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-354\"},{\"lang\":\"en\",\"value\":\"CWE-924\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:freeradius:freeradius:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.27\",\"matchCriteriaId\":\"1C73FF4C-13DE-4050-BD56-447F9382AA4D\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75B1EDA5-F189-440D-AD0E-C70DD2C0FEE5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"046FB51E-B768-44D3-AEB5-D857145CA840\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sonicwall:sonicos:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1CF61DAA-8295-4407-B125-1714E1565965\"}]}]}],\"references\":[{\"url\":\"http://www.openwall.com/lists/oss-security/2024/07/09/4\",\"source\":\"cret@cert.org\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-723487.html\",\"source\":\"cret@cert.org\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-794185.html\",\"source\":\"cret@cert.org\"},{\"url\":\"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/\",\"source\":\"cret@cert.org\",\"tags\":[\"Technical Description\"]},{\"url\":\"https://datatracker.ietf.org/doc/html/rfc2865\",\"source\":\"cret@cert.org\",\"tags\":[\"Technical Description\"]},{\"url\":\"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014\",\"source\":\"cret@cert.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.blastradius.fail/\",\"source\":\"cret@cert.org\",\"tags\":[\"Technical Description\"]},{\"url\":\"http://www.openwall.com/lists/oss-security/2024/07/09/4\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Technical Description\"]},{\"url\":\"https://datatracker.ietf.org/doc/html/rfc2865\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Technical Description\"]},{\"url\":\"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20240822-0001/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.blastradius.fail/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Technical Description\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/456537\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-364175.html\",\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-723487.html\",\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-770770.html\",\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-794185.html\",\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://security.netapp.com/advisory/ntap-20240822-0001/\"}, {\"url\": \"https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol\"}, {\"url\": \"https://datatracker.ietf.org/doc/html/rfc2865\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.blastradius.fail/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://www.openwall.com/lists/oss-security/2024/07/09/4\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.kb.cert.org/vuls/id/456537\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2025-11-04T17:20:52.225Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-3596\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-11T03:55:37.141738Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*\"], \"vendor\": \"ietf\", \"product\": \"rfc\", \"versions\": [{\"status\": \"affected\", \"version\": \"2865\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-24T20:18:02.244Z\"}}], \"cna\": {\"title\": \"RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability\"}], \"affected\": [{\"vendor\": \"IETF\", \"product\": \"RFC\", \"versions\": [{\"status\": \"affected\", \"version\": \"2865\"}]}], \"references\": [{\"url\": \"https://datatracker.ietf.org/doc/html/rfc2865\"}, {\"url\": \"https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/\"}, {\"url\": \"https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf\"}, {\"url\": \"https://www.blastradius.fail/\"}, {\"url\": \"http://www.openwall.com/lists/oss-security/2024/07/09/4\"}, {\"url\": \"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-794185.html\", \"name\": \"Siemens Security Advisory by Siemens ProductCERT for SIPROTEC, SICAM and related product\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-723487.html\", \"name\": \"Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"env\": \"prod\", \"engine\": \"VINCE 3.0.4\", \"origin\": \"https://cveawg.mitre.org/api/cve/CVE-2024-3596\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-328: Use of Weak Hash\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel\"}]}], \"providerMetadata\": {\"orgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"shortName\": \"certcc\", \"dateUpdated\": \"2025-09-03T17:29:16.788Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-3596\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-04T17:20:52.225Z\", \"dateReserved\": \"2024-04-10T15:09:45.391Z\", \"assignerOrgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"datePublished\": \"2024-07-09T12:02:53.001Z\", \"assignerShortName\": \"certcc\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Title
RADIUS Protocol under RFC 2865存在未明漏洞
Description
RADIUS Protocol under RFC 2865是RFC开源的一个网络协议。
RADIUS Protocol under RFC 2865存在安全漏洞,攻击者利用该漏洞使用针对MD5响应验证器签名的选择前缀冲突攻击,将任何有效的响应(Access-Accept, Access-Reject或Access-Challenge)修改为任何其他响应。
Severity
高
Formal description
厂商尚未提供漏洞修补方案,请关注厂商主页及时更新: https://datatracker.ietf.org/doc/html/rfc2865
Reference
http://www.openwall.com/lists/oss-security/2024/07/09/4
Impacted products
| Name | IETF RFC 2865 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2024-3596"
}
},
"description": "RADIUS Protocol under RFC 2865\u662fRFC\u5f00\u6e90\u7684\u4e00\u4e2a\u7f51\u7edc\u534f\u8bae\u3002\n\nRADIUS Protocol under RFC 2865\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u5229\u7528\u8be5\u6f0f\u6d1e\u4f7f\u7528\u9488\u5bf9MD5\u54cd\u5e94\u9a8c\u8bc1\u5668\u7b7e\u540d\u7684\u9009\u62e9\u524d\u7f00\u51b2\u7a81\u653b\u51fb\uff0c\u5c06\u4efb\u4f55\u6709\u6548\u7684\u54cd\u5e94(Access-Accept, Access-Reject\u6216Access-Challenge)\u4fee\u6539\u4e3a\u4efb\u4f55\u5176\u4ed6\u54cd\u5e94\u3002",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u8865\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u53ca\u65f6\u66f4\u65b0\uff1a\r\nhttps://datatracker.ietf.org/doc/html/rfc2865",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2024-33450",
"openTime": "2024-07-23",
"products": {
"product": "IETF RFC 2865"
},
"referenceLink": "http://www.openwall.com/lists/oss-security/2024/07/09/4",
"serverity": "\u9ad8",
"submitTime": "2024-07-23",
"title": "RADIUS Protocol under RFC 2865\u5b58\u5728\u672a\u660e\u6f0f\u6d1e"
}
FKIE_CVE-2024-3596
Vulnerability from fkie_nvd - Published: 2024-07-09 12:15 - Updated: 2026-05-12 12:16
Severity
9.0 (Critical) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
9.0 (Critical) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
9.0 (Critical) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| freeradius | freeradius | * | |
| broadcom | brocade_sannav | - | |
| broadcom | fabric_operating_system | - | |
| sonicwall | sonicos | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:freeradius:freeradius:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1C73FF4C-13DE-4050-BD56-447F9382AA4D",
"versionEndExcluding": "3.0.27",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75B1EDA5-F189-440D-AD0E-C70DD2C0FEE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:broadcom:fabric_operating_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "046FB51E-B768-44D3-AEB5-D857145CA840",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sonicwall:sonicos:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1CF61DAA-8295-4407-B125-1714E1565965",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
},
{
"lang": "es",
"value": "El protocolo RADIUS seg\u00fan RFC 2865 es susceptible a ataques de falsificaci\u00f3n por parte de un atacante local que puede modificar cualquier respuesta v\u00e1lida (acceso-aceptaci\u00f3n, acceso-rechazo o acceso-desaf\u00edo) a cualquier otra respuesta utilizando un ataque de colisi\u00f3n de prefijo elegido contra la firma del autenticador de respuesta MD5. ."
}
],
"id": "CVE-2024-3596",
"lastModified": "2026-05-12T12:16:57.943",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 6.0,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-07-09T12:15:20.700",
"references": [
{
"source": "cret@cert.org",
"tags": [
"Mailing List"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"source": "cret@cert.org",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"source": "cret@cert.org",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"source": "cret@cert.org",
"tags": [
"Technical Description"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"source": "cret@cert.org",
"tags": [
"Technical Description"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"source": "cret@cert.org",
"tags": [
"Third Party Advisory"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"source": "cret@cert.org",
"tags": [
"Third Party Advisory"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"source": "cret@cert.org",
"tags": [
"Technical Description"
],
"url": "https://www.blastradius.fail/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description"
],
"url": "https://www.blastradius.fail/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.kb.cert.org/vuls/id/456537"
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-354"
},
{
"lang": "en",
"value": "CWE-924"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-3G8X-WQFP-Q876
Vulnerability from github – Published: 2024-07-09 12:30 – Updated: 2026-05-12 12:31
VLAI
Details
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Severity
9.0 (Critical)
{
"affected": [],
"aliases": [
"CVE-2024-3596"
],
"database_specific": {
"cwe_ids": [
"CWE-200",
"CWE-354"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-07-09T12:15:20Z",
"severity": "CRITICAL"
},
"details": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.",
"id": "GHSA-3g8x-wqfp-q876",
"modified": "2026-05-12T12:31:59Z",
"published": "2024-07-09T12:30:58Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-3596"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"type": "WEB",
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius"
},
{
"type": "WEB",
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"type": "WEB",
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"type": "WEB",
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"type": "WEB",
"url": "https://security.netapp.com/advisory/ntap-20240822-0001"
},
{
"type": "WEB",
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"type": "WEB",
"url": "https://www.blastradius.fail"
},
{
"type": "WEB",
"url": "https://www.kb.cert.org/vuls/id/456537"
},
{
"type": "WEB",
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2024-3596
Vulnerability from gsd - Updated: 2024-04-11 05:03Details
** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2024-3596"
],
"id": "GSD-2024-3596",
"modified": "2024-04-11T05:03:27.122669Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2024-3596",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}
}
}
ICSA-24-193-05
Vulnerability from csaf_cisa - Published: 2024-07-09 00:00 - Updated: 2026-05-14 06:00Summary
Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC
Notes
Summary: This advisory documents the impact of CVE-2024-3596 (also dubbed "Blastradius"), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products.
The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to forge Access-Request packets in a way that enables them to modify the corresponding server response packet at will, e.g., turning an "Access-Reject" message into an "Access-Accept". This would cause the Network Access Server to grant the attackers access to the network with the attackers desired authorization (and without the need of knowing or guessing legitimate access credentials).
Further details incl. external references can be found in the chapter "Additional Information".
Siemens has released new versions for several affected products and recommends to update to the latest versions, and to configure the updated systems as recommended in the chapter "Additional Information".
Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. See chapter "Additional Information" for details.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Siemens ProductCERT SSA-723487 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Critical infrastructure sectors: Critical Manufacturing, Communications
Countries/areas deployed: Worldwide
Company headquarters location: Germany
9.0 (Critical)
Affected products
Known affected
497 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM CROSSBOW
Siemens / RUGGEDCOM CROSSBOW
|
vers:intdot/<5.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i800
Siemens / RUGGEDCOM i800
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i800NC
Siemens / RUGGEDCOM i800NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i801
Siemens / RUGGEDCOM i801
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i801NC
Siemens / RUGGEDCOM i801NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i802
Siemens / RUGGEDCOM i802
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i802NC
Siemens / RUGGEDCOM i802NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i803
Siemens / RUGGEDCOM i803
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM i803NC
Siemens / RUGGEDCOM i803NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M2100
Siemens / RUGGEDCOM M2100
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M2100NC
Siemens / RUGGEDCOM M2100NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M2200
Siemens / RUGGEDCOM M2200
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M2200NC
Siemens / RUGGEDCOM M2200NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M969
Siemens / RUGGEDCOM M969
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM M969NC
Siemens / RUGGEDCOM M969NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RMC30
Siemens / RUGGEDCOM RMC30
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RMC30NC
Siemens / RUGGEDCOM RMC30NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RMC8388 V4.X
Siemens / RUGGEDCOM RMC8388 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RMC8388 V5.X
Siemens / RUGGEDCOM RMC8388 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RMC8388NC V4.X
Siemens / RUGGEDCOM RMC8388NC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RMC8388NC V5.X
Siemens / RUGGEDCOM RMC8388NC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX MX5000
Siemens / RUGGEDCOM ROX MX5000
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX MX5000RE
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1400
Siemens / RUGGEDCOM ROX RX1400
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1500
Siemens / RUGGEDCOM ROX RX1500
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1501
Siemens / RUGGEDCOM ROX RX1501
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1510
Siemens / RUGGEDCOM ROX RX1510
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1511
Siemens / RUGGEDCOM ROX RX1511
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1512
Siemens / RUGGEDCOM ROX RX1512
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1524
Siemens / RUGGEDCOM ROX RX1524
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX1536
Siemens / RUGGEDCOM ROX RX1536
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM ROX RX5000
Siemens / RUGGEDCOM ROX RX5000
|
vers:intdot/<2.17.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RP110
Siemens / RUGGEDCOM RP110
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RP110NC
Siemens / RUGGEDCOM RP110NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600
Siemens / RUGGEDCOM RS1600
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600F
Siemens / RUGGEDCOM RS1600F
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600FNC
Siemens / RUGGEDCOM RS1600FNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600NC
Siemens / RUGGEDCOM RS1600NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600T
Siemens / RUGGEDCOM RS1600T
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS1600TNC
Siemens / RUGGEDCOM RS1600TNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS400
Siemens / RUGGEDCOM RS400
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS400NC
Siemens / RUGGEDCOM RS400NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS401
Siemens / RUGGEDCOM RS401
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS401NC
Siemens / RUGGEDCOM RS401NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416
Siemens / RUGGEDCOM RS416
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416NC
Siemens / RUGGEDCOM RS416NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416NCv2 V4.X
Siemens / RUGGEDCOM RS416NCv2 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416NCv2 V5.X
Siemens / RUGGEDCOM RS416NCv2 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416P
Siemens / RUGGEDCOM RS416P
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416PNC
Siemens / RUGGEDCOM RS416PNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416PNCv2 V4.X
Siemens / RUGGEDCOM RS416PNCv2 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416PNCv2 V5.X
Siemens / RUGGEDCOM RS416PNCv2 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416Pv2 V4.X
Siemens / RUGGEDCOM RS416Pv2 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416Pv2 V5.X
Siemens / RUGGEDCOM RS416Pv2 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416v2 V4.X
Siemens / RUGGEDCOM RS416v2 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS416v2 V5.X
Siemens / RUGGEDCOM RS416v2 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000
Siemens / RUGGEDCOM RS8000
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000A
Siemens / RUGGEDCOM RS8000A
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000ANC
Siemens / RUGGEDCOM RS8000ANC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000H
Siemens / RUGGEDCOM RS8000H
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000HNC
Siemens / RUGGEDCOM RS8000HNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000NC
Siemens / RUGGEDCOM RS8000NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000T
Siemens / RUGGEDCOM RS8000T
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS8000TNC
Siemens / RUGGEDCOM RS8000TNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900
Siemens / RUGGEDCOM RS900
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900 (32M) V4.X
Siemens / RUGGEDCOM RS900 (32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900 (32M) V5.X
Siemens / RUGGEDCOM RS900 (32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900G
Siemens / RUGGEDCOM RS900G
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900G (32M) V4.X
Siemens / RUGGEDCOM RS900G (32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900G (32M) V5.X
Siemens / RUGGEDCOM RS900G (32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900GNC
Siemens / RUGGEDCOM RS900GNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900GNC(32M) V4.X
Siemens / RUGGEDCOM RS900GNC(32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900GNC(32M) V5.X
Siemens / RUGGEDCOM RS900GNC(32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900GP
Siemens / RUGGEDCOM RS900GP
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900GPNC
Siemens / RUGGEDCOM RS900GPNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900L
Siemens / RUGGEDCOM RS900L
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900LNC
Siemens / RUGGEDCOM RS900LNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900M-GETS-C01
Siemens / RUGGEDCOM RS900M-GETS-C01
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900M-GETS-XX
Siemens / RUGGEDCOM RS900M-GETS-XX
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900M-STND-C01
Siemens / RUGGEDCOM RS900M-STND-C01
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900M-STND-XX
Siemens / RUGGEDCOM RS900M-STND-XX
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900MNC-GETS-C01
Siemens / RUGGEDCOM RS900MNC-GETS-C01
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900MNC-GETS-XX
Siemens / RUGGEDCOM RS900MNC-GETS-XX
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900MNC-STND-XX
Siemens / RUGGEDCOM RS900MNC-STND-XX
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900MNC-STND-XX-C01
Siemens / RUGGEDCOM RS900MNC-STND-XX-C01
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900NC
Siemens / RUGGEDCOM RS900NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900NC(32M) V4.X
Siemens / RUGGEDCOM RS900NC(32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900NC(32M) V5.X
Siemens / RUGGEDCOM RS900NC(32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS900W
Siemens / RUGGEDCOM RS900W
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS910
Siemens / RUGGEDCOM RS910
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS910L
Siemens / RUGGEDCOM RS910L
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS910LNC
Siemens / RUGGEDCOM RS910LNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS910NC
Siemens / RUGGEDCOM RS910NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS910W
Siemens / RUGGEDCOM RS910W
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS920L
Siemens / RUGGEDCOM RS920L
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS920LNC
Siemens / RUGGEDCOM RS920LNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS920W
Siemens / RUGGEDCOM RS920W
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS930L
Siemens / RUGGEDCOM RS930L
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS930LNC
Siemens / RUGGEDCOM RS930LNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS930W
Siemens / RUGGEDCOM RS930W
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS940G
Siemens / RUGGEDCOM RS940G
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS940GNC
Siemens / RUGGEDCOM RS940GNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS969
Siemens / RUGGEDCOM RS969
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RS969NC
Siemens / RUGGEDCOM RS969NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100
Siemens / RUGGEDCOM RSG2100
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100 (32M) V4.X
Siemens / RUGGEDCOM RSG2100 (32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100 (32M) V5.X
Siemens / RUGGEDCOM RSG2100 (32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100NC
Siemens / RUGGEDCOM RSG2100NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100NC(32M) V4.X
Siemens / RUGGEDCOM RSG2100NC(32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100NC(32M) V5.X
Siemens / RUGGEDCOM RSG2100NC(32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100P
Siemens / RUGGEDCOM RSG2100P
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100P (32M) V4.X
Siemens / RUGGEDCOM RSG2100P (32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100P (32M) V5.X
Siemens / RUGGEDCOM RSG2100P (32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100PNC
Siemens / RUGGEDCOM RSG2100PNC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100PNC (32M) V4.X
Siemens / RUGGEDCOM RSG2100PNC (32M) V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2100PNC (32M) V5.X
Siemens / RUGGEDCOM RSG2100PNC (32M) V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2200
Siemens / RUGGEDCOM RSG2200
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2200NC
Siemens / RUGGEDCOM RSG2200NC
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2288 V4.X
Siemens / RUGGEDCOM RSG2288 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2288 V5.X
Siemens / RUGGEDCOM RSG2288 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2288NC V4.X
Siemens / RUGGEDCOM RSG2288NC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2288NC V5.X
Siemens / RUGGEDCOM RSG2288NC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300 V4.X
Siemens / RUGGEDCOM RSG2300 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300 V5.X
Siemens / RUGGEDCOM RSG2300 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300NC V4.X
Siemens / RUGGEDCOM RSG2300NC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300NC V5.X
Siemens / RUGGEDCOM RSG2300NC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300P V4.X
Siemens / RUGGEDCOM RSG2300P V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300P V5.X
Siemens / RUGGEDCOM RSG2300P V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300PNC V4.X
Siemens / RUGGEDCOM RSG2300PNC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2300PNC V5.X
Siemens / RUGGEDCOM RSG2300PNC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2488 V4.X
Siemens / RUGGEDCOM RSG2488 V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2488 V5.X
Siemens / RUGGEDCOM RSG2488 V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2488NC V4.X
Siemens / RUGGEDCOM RSG2488NC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG2488NC V5.X
Siemens / RUGGEDCOM RSG2488NC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG907R
Siemens / RUGGEDCOM RSG907R
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG908C
Siemens / RUGGEDCOM RSG908C
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG909R
Siemens / RUGGEDCOM RSG909R
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG910C
Siemens / RUGGEDCOM RSG910C
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG920P V4.X
Siemens / RUGGEDCOM RSG920P V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG920P V5.X
Siemens / RUGGEDCOM RSG920P V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG920PNC V4.X
Siemens / RUGGEDCOM RSG920PNC V4.X
|
vers:intdot/<4.3.11 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSG920PNC V5.X
Siemens / RUGGEDCOM RSG920PNC V5.X
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSL910
Siemens / RUGGEDCOM RSL910
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RSL910NC
Siemens / RUGGEDCOM RSL910NC
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RST2228
Siemens / RUGGEDCOM RST2228
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RST2228P
Siemens / RUGGEDCOM RST2228P
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RST2428P (6GK6242-6PA00)
Siemens / RUGGEDCOM RST2428P (6GK6242-6PA00)
|
6GK6242-6PA00
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RST916C
Siemens / RUGGEDCOM RST916C
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
RUGGEDCOM RST916P
Siemens / RUGGEDCOM RST916P
|
vers:intdot/<5.10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)
Siemens / SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)
|
6GK5874-3AA00-2FA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (6GK5876-4AA10-2BA2)
Siemens / SCALANCE M876-4 (6GK5876-4AA10-2BA2)
|
6GK5876-4AA10-2BA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)
Siemens / SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)
|
6GK5853-2EA10-2AA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)
Siemens / SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)
|
6GK5853-2EA10-2BA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)
Siemens / SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)
|
6GK5856-2EA10-3AA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)
Siemens / SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)
|
6GK5856-2EA10-3BA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)
Siemens / SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)
|
6GK5856-2EA00-3FA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)
Siemens / SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)
|
6GK5615-0AA01-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<8.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)
Siemens / SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)
|
6GK5762-1AJ00-6AA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)
Siemens / SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)
|
6GK5763-1AL00-7DC0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)
Siemens / SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)
|
6GK5763-1AL00-7DB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)
Siemens / SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)
|
6GK5766-1GE00-7DC0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)
Siemens / SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)
|
6GK5766-1GE00-7TC0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)
Siemens / SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)
|
6GK5762-1AJ00-1AA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)
Siemens / SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)
|
6GK5762-1AJ00-2AA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)
Siemens / SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)
|
6GK5763-1AL00-3AB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)
Siemens / SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)
|
6GK5763-1AL00-3DB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)
Siemens / SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)
|
6GK5766-1GE00-3DC0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<3.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
Siemens / SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
|
6GK5302-7GD00-3GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
Siemens / SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
|
6GK5302-7GD00-3EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
Siemens / SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
|
6GK5302-7GD00-1GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
Siemens / SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
|
6GK5302-7GD00-1EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
Siemens / SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
|
6GK5302-7GD00-4GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
Siemens / SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
|
6GK5302-7GD00-4EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Siemens / SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
|
6GK5302-7GD00-2GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
Siemens / SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
|
6GK5302-7GD00-2EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
Siemens / SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
|
6GK5304-2BD00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
Siemens / SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
|
6GK5306-1BF00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
Siemens / SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
|
6GK5307-2FD00-3GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
Siemens / SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
|
6GK5307-2FD00-3EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
Siemens / SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
|
6GK5307-2FD00-1GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
Siemens / SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
|
6GK5307-2FD00-1EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
Siemens / SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
|
6GK5307-2FD00-4GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
Siemens / SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
|
6GK5307-2FD00-4EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
Siemens / SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
|
6GK5307-2FD00-2GA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
Siemens / SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
|
6GK5307-2FD00-2EA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-3 (6GK5307-3BL00-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL00-2AA3)
|
6GK5307-3BL00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-3 (6GK5307-3BL10-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL10-2AA3)
|
6GK5307-3BL10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
|
6GK5307-3BM00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
|
6GK5307-3BM10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2 (6GK5308-2FL00-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL00-2AA3)
|
6GK5308-2FL00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2 (6GK5308-2FL10-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL10-2AA3)
|
6GK5308-2FL10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
|
6GK5308-2FM00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
|
6GK5308-2FM10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
|
6GK5308-2FN00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
|
6GK5308-2FN10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
|
6GK5308-2FP00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
|
6GK5308-2FP10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M (6GK5308-2GG00-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG00-2AA2)
|
6GK5308-2GG00-2AA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M (6GK5308-2GG10-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG10-2AA2)
|
6GK5308-2GG10-2AA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
|
6GK5308-2QG00-2AA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
|
6GK5308-2QG10-2AA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
|
6GK5308-2GG00-2CA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
|
6GK5308-2GG10-2CA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X310 (6GK5310-0FA00-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA00-2AA3)
|
6GK5310-0FA00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X310 (6GK5310-0FA10-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA10-2AA3)
|
6GK5310-0FA10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X310FE (6GK5310-0BA00-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA00-2AA3)
|
6GK5310-0BA00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X310FE (6GK5310-0BA10-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA10-2AA3)
|
6GK5310-0BA10-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
Siemens / SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
|
6GK5320-1BD00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
Siemens / SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
|
6GK5320-3BF00-2AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE X408-2 (6GK5408-2FD00-2AA2)
Siemens / SCALANCE X408-2 (6GK5408-2FD00-2AA2)
|
6GK5408-2FD00-2AA2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2 (SC) (6GK5206-2BD00-2TB2)
Siemens / SCALANCE XB206-2 (SC) (6GK5206-2BD00-2TB2)
|
6GK5206-2BD00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2 (ST/BFOC) (6GK5206-2BF00-2TB2)
Siemens / SCALANCE XB206-2 (ST/BFOC) (6GK5206-2BF00-2TB2)
|
6GK5206-2BF00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2 LD (6GK5206-2BF00-2AB2)
Siemens / SCALANCE XB206-2 LD (6GK5206-2BF00-2AB2)
|
6GK5206-2BF00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2 SC (6GK5206-2BD00-2AB2)
Siemens / SCALANCE XB206-2 SC (6GK5206-2BD00-2AB2)
|
6GK5206-2BD00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2 ST (6GK5206-2BB00-2AB2)
Siemens / SCALANCE XB206-2 ST (6GK5206-2BB00-2AB2)
|
6GK5206-2BB00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB206-2LD (6GK5206-2BB00-2TB2)
Siemens / SCALANCE XB206-2LD (6GK5206-2BB00-2TB2)
|
6GK5206-2BB00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC316-8 (6GK5324-8TS00-2AC2)
Siemens / SCALANCE XC316-8 (6GK5324-8TS00-2AC2)
|
6GK5324-8TS00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC324-4 (6GK5328-4TS00-2AC2)
Siemens / SCALANCE XC324-4 (6GK5328-4TS00-2AC2)
|
6GK5328-4TS00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2)
Siemens / SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2)
|
6GK5328-4TS00-2EC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC332 (6GK5332-0GA00-2AC2)
Siemens / SCALANCE XC332 (6GK5332-0GA00-2AC2)
|
6GK5332-0GA00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC416-8 (6GK5424-8TR00-2AC2)
Siemens / SCALANCE XC416-8 (6GK5424-8TR00-2AC2)
|
6GK5424-8TR00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC424-4 (6GK5428-4TR00-2AC2)
Siemens / SCALANCE XC424-4 (6GK5428-4TR00-2AC2)
|
6GK5428-4TR00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC432 (6GK5432-0GR00-2AC2)
Siemens / SCALANCE XC432 (6GK5432-0GR00-2AC2)
|
6GK5432-0GR00-2AC2
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204G (6GK5204-0GA00-1UF2)
Siemens / SCALANCE XF204G (6GK5204-0GA00-1UF2)
|
6GK5204-0GA00-1UF2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA10-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA10-2AS6)
|
6GK5208-0HA10-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA10-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA10-2ES6)
|
6GK5208-0HA10-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208G (6GK5208-0XA00-2AS6)
Siemens / SCALANCE XP208G (6GK5208-0XA00-2AS6)
|
6GK5208-0XA00-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208G EEC (6GK5208-0XA00-2ES6)
Siemens / SCALANCE XP208G EEC (6GK5208-0XA00-2ES6)
|
6GK5208-0XA00-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208G PoE EEC (6GK5208-0YA00-5ES6)
Siemens / SCALANCE XP208G PoE EEC (6GK5208-0YA00-5ES6)
|
6GK5208-0YA00-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208G PP (6GK5208-0JA00-2AS6)
Siemens / SCALANCE XP208G PP (6GK5208-0JA00-2AS6)
|
6GK5208-0JA00-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA10-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA10-5ES6)
|
6GK5208-0UA10-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (V2) (6GK5216-0HA10-2AS6)
Siemens / SCALANCE XP216 (V2) (6GK5216-0HA10-2AS6)
|
6GK5216-0HA10-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (V2) (6GK5216-0HA10-2ES6)
Siemens / SCALANCE XP216EEC (V2) (6GK5216-0HA10-2ES6)
|
6GK5216-0HA10-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216G (6GK5216-0XA00-2AS6)
Siemens / SCALANCE XP216G (6GK5216-0XA00-2AS6)
|
6GK5216-0XA00-2AS6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216G EEC (6GK5216-0XA00-2ES6)
Siemens / SCALANCE XP216G EEC (6GK5216-0XA00-2ES6)
|
6GK5216-0XA00-2ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216G PoE EEC (6GK5216-0YA00-5ES6)
Siemens / SCALANCE XP216G PoE EEC (6GK5216-0YA00-5ES6)
|
6GK5216-0YA00-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216PoE EEC (V2) (6GK5216-0UA10-5ES6)
Siemens / SCALANCE XP216PoE EEC (V2) (6GK5216-0UA10-5ES6)
|
6GK5216-0UA10-5ES6
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR302-32 (6GK5334-5TS00-2AR3)
Siemens / SCALANCE XR302-32 (6GK5334-5TS00-2AR3)
|
6GK5334-5TS00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR302-32 (6GK5334-5TS00-3AR3)
Siemens / SCALANCE XR302-32 (6GK5334-5TS00-3AR3)
|
6GK5334-5TS00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR302-32 (6GK5334-5TS00-4AR3)
Siemens / SCALANCE XR302-32 (6GK5334-5TS00-4AR3)
|
6GK5334-5TS00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR322-12 (6GK5334-3TS00-2AR3)
Siemens / SCALANCE XR322-12 (6GK5334-3TS00-2AR3)
|
6GK5334-3TS00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR322-12 (6GK5334-3TS00-3AR3)
Siemens / SCALANCE XR322-12 (6GK5334-3TS00-3AR3)
|
6GK5334-3TS00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR322-12 (6GK5334-3TS00-4AR3)
Siemens / SCALANCE XR322-12 (6GK5334-3TS00-4AR3)
|
6GK5334-3TS00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
|
6GK5324-0GG00-3AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
|
6GK5324-0GG10-3AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
|
6GK5324-0GG00-3HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
|
6GK5324-0GG10-3HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
|
6GK5324-0GG00-1AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
|
6GK5324-0GG10-1AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
|
6GK5324-0GG00-1HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
|
6GK5324-0GG10-1HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
|
6GK5324-0GG00-1CR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
|
6GK5324-0GG10-1CR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
|
6GK5324-4GG00-3ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
|
6GK5324-4GG10-3ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
|
6GK5324-4GG00-3JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
|
6GK5324-4GG10-3JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
|
6GK5324-4GG00-1ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
|
6GK5324-4GG10-1ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
|
6GK5324-4GG00-1JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
|
6GK5324-4GG10-1JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
|
6GK5324-4GG00-4ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
|
6GK5324-4GG10-4ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
|
6GK5324-4GG00-4JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
|
6GK5324-4GG10-4JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
|
6GK5324-4GG00-2ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
|
6GK5324-4GG10-2ER2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
|
6GK5324-4GG00-2JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
|
6GK5324-4GG10-2JR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
|
6GK5324-4QG00-3AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)
|
6GK5324-4QG10-3AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
|
6GK5324-4QG00-3HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)
|
6GK5324-4QG10-3HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
|
6GK5324-4QG00-1AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)
|
6GK5324-4QG10-1AR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
|
6GK5324-4QG00-1HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)
|
6GK5324-4QG10-1HR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
|
6GK5324-4QG00-1CR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)
|
6GK5324-4QG10-1CR2
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-8 (6GK5334-2TS00-2AR3)
Siemens / SCALANCE XR326-8 (6GK5334-2TS00-2AR3)
|
6GK5334-2TS00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-8 (6GK5334-2TS00-3AR3)
Siemens / SCALANCE XR326-8 (6GK5334-2TS00-3AR3)
|
6GK5334-2TS00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-8 (6GK5334-2TS00-4AR3)
Siemens / SCALANCE XR326-8 (6GK5334-2TS00-4AR3)
|
6GK5334-2TS00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3)
Siemens / SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3)
|
6GK5334-2TS00-2ER3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR502-32 (6GK5534-5TR00-2AR3)
Siemens / SCALANCE XR502-32 (6GK5534-5TR00-2AR3)
|
6GK5534-5TR00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR502-32 (6GK5534-5TR00-3AR3)
Siemens / SCALANCE XR502-32 (6GK5534-5TR00-3AR3)
|
6GK5534-5TR00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR502-32 (6GK5534-5TR00-4AR3)
Siemens / SCALANCE XR502-32 (6GK5534-5TR00-4AR3)
|
6GK5534-5TR00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR522-12 (6GK5534-3TR00-2AR3)
Siemens / SCALANCE XR522-12 (6GK5534-3TR00-2AR3)
|
6GK5534-3TR00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR522-12 (6GK5534-3TR00-3AR3)
Siemens / SCALANCE XR522-12 (6GK5534-3TR00-3AR3)
|
6GK5534-3TR00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR522-12 (6GK5534-3TR00-4AR3)
Siemens / SCALANCE XR522-12 (6GK5534-3TR00-4AR3)
|
6GK5534-3TR00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR524-8WG (6GK5532-2SR00-2AR3)
Siemens / SCALANCE XR524-8WG (6GK5532-2SR00-2AR3)
|
6GK5532-2SR00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8WG (6GK5532-2SR00-2RR3)
Siemens / SCALANCE XR524-8WG (6GK5532-2SR00-2RR3)
|
6GK5532-2SR00-2RR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8WG (6GK5532-2SR00-3AR3)
Siemens / SCALANCE XR524-8WG (6GK5532-2SR00-3AR3)
|
6GK5532-2SR00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8WG (6GK5532-2SR00-3RR3)
Siemens / SCALANCE XR524-8WG (6GK5532-2SR00-3RR3)
|
6GK5532-2SR00-3RR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8 (6GK5534-2TR00-2AR3)
Siemens / SCALANCE XR526-8 (6GK5534-2TR00-2AR3)
|
6GK5534-2TR00-2AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8 (6GK5534-2TR00-3AR3)
Siemens / SCALANCE XR526-8 (6GK5534-2TR00-3AR3)
|
6GK5534-2TR00-3AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8 (6GK5534-2TR00-4AR3)
Siemens / SCALANCE XR526-8 (6GK5534-2TR00-4AR3)
|
6GK5534-2TR00-4AR3
|
vers:intdot/<1.3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)
Siemens / SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)
|
6GK5334-5TS01-3AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)
Siemens / SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)
|
6GK5334-5TS01-2AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)
|
6GK5334-5TS01-4AR3
|
vers:intdot/<3.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SINEC INS
Siemens / SINEC INS
|
vers:intdot/<1.0.2.4 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
Siemens / SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
|
6AG1308-2FL10-4AA3
|
vers:intdot/<4.1.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
References
13 references
Acknowledgments
Siemens
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "This advisory documents the impact of CVE-2024-3596 (also dubbed \"Blastradius\"), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products.\n\nThe vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to forge Access-Request packets in a way that enables them to modify the corresponding server response packet at will, e.g., turning an \"Access-Reject\" message into an \"Access-Accept\". This would cause the Network Access Server to grant the attackers access to the network with the attackers desired authorization (and without the need of knowing or guessing legitimate access credentials).\n\nFurther details incl. external references can be found in the chapter \"Additional Information\".\nSiemens has released new versions for several affected products and recommends to update to the latest versions, and to configure the updated systems as recommended in the chapter \"Additional Information\".\nSiemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. See chapter \"Additional Information\" for details.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-723487 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "Critical Manufacturing, Communications",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-723487: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-723487.json"
},
{
"category": "self",
"summary": "SSA-723487: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-193-05 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-05.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-193-05 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-05"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC",
"tracking": {
"current_release_date": "2026-05-14T06:00:00.000000Z",
"generator": {
"date": "2026-05-13T15:52:20.601533Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-24-193-05",
"initial_release_date": "2024-07-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-07-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-07-22T00:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "Clarified that the fix for SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) in V4.1.8 only covers RADIUS client mitigation C1, but not C2"
},
{
"date": "2024-11-12T00:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Added fix for RUGGEDCOM CROSSBOW"
},
{
"date": "2024-12-10T00:00:00.000000Z",
"legacy_version": "Additional Release 3",
"number": "4",
"summary": "Added fix (and related important recommendations in chapter Additional Information) for RUGGEDCOM ROS V4.x devices; Added additional SINEC OS-based devices as affected products: RUGGEDCOM RST2428P and SCALANCE XC-300, XR-300, XC-400 families, and additional devices in the SCALANCE XR-500 family"
},
{
"date": "2025-01-14T00:00:00.000000Z",
"legacy_version": "Additional Release 4",
"number": "5",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11ax family and for SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)"
},
{
"date": "2025-03-11T00:00:00.000000Z",
"legacy_version": "Additional Release 5",
"number": "6",
"summary": "Added fix for SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)"
},
{
"date": "2025-06-10T00:00:00.000000Z",
"legacy_version": "Additional Release 6",
"number": "7",
"summary": "Clarified that SINEC INS is only affected when the Relay feature is used; added fix for the RUGGEDCOM RST2428P, SCALANCE XC-300, SCALANCE XC-400 and SCALANCE XR-300 (6GK5334-xTSxx) families and for some of the devices in the SCALANCE XM-400/XR-500 and SCALANCE XCM-/XRM-/XCH-/XRH-300 families"
},
{
"date": "2025-07-08T00:00:00.000000Z",
"legacy_version": "Additional Release 7",
"number": "8",
"summary": "Added fix for SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG family, for SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family (MSPS V1.3), for RUGGEDCOM ROS V5.X family and for SINEC INS (relay feature); Clarified the applicability of the MSPS V1.3 and the SINEC OS V3.2 fix releases for product families that support both"
},
{
"date": "2025-12-09T00:00:00.000000Z",
"legacy_version": "Additional Release 8",
"number": "9",
"summary": "Added fix for RUGGEDCOM ROX II family"
},
{
"date": "2026-05-12T00:00:00.000000Z",
"legacy_version": "Additional Release 9",
"number": "10",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11n family."
},
{
"date": "2026-05-14T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "11",
"summary": "CISA Republication update based on Siemens ProductCERT SSA-723487 advisory"
}
],
"status": "final",
"version": "11"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.6",
"product": {
"name": "RUGGEDCOM CROSSBOW",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM CROSSBOW"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i800",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i800"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i800NC",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i800NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i801",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i801"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i801NC",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i801NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i802",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i802"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i802NC",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i802NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i803",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i803"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM i803NC",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM i803NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M2100",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M2100"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M2100NC",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M2100NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M2200",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M2200"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M2200NC",
"product_id": "CSAFPID-0013"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M2200NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M969",
"product_id": "CSAFPID-0014"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M969"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM M969NC",
"product_id": "CSAFPID-0015"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM M969NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RMC30",
"product_id": "CSAFPID-0018"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC30"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RMC30NC",
"product_id": "CSAFPID-0019"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC30NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RMC8388 V4.X",
"product_id": "CSAFPID-0020"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC8388 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RMC8388 V5.X",
"product_id": "CSAFPID-0021"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC8388 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RMC8388NC V4.X",
"product_id": "CSAFPID-0022"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC8388NC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RMC8388NC V5.X",
"product_id": "CSAFPID-0023"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RMC8388NC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX MX5000",
"product_id": "CSAFPID-0024"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX MX5000RE",
"product_id": "CSAFPID-0025"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000RE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1400",
"product_id": "CSAFPID-0026"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1500",
"product_id": "CSAFPID-0027"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1500"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1501",
"product_id": "CSAFPID-0028"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1501"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1510",
"product_id": "CSAFPID-0029"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1510"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1511",
"product_id": "CSAFPID-0030"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1511"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1512",
"product_id": "CSAFPID-0031"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1512"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1524",
"product_id": "CSAFPID-0032"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1524"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX1536",
"product_id": "CSAFPID-0033"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1536"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.17.0",
"product": {
"name": "RUGGEDCOM ROX RX5000",
"product_id": "CSAFPID-0034"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RP110",
"product_id": "CSAFPID-0035"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RP110"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RP110NC",
"product_id": "CSAFPID-0036"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RP110NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600",
"product_id": "CSAFPID-0037"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600F",
"product_id": "CSAFPID-0038"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600F"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600FNC",
"product_id": "CSAFPID-0039"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600FNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600NC",
"product_id": "CSAFPID-0040"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600T",
"product_id": "CSAFPID-0041"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600T"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS1600TNC",
"product_id": "CSAFPID-0042"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS1600TNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS400",
"product_id": "CSAFPID-0043"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS400NC",
"product_id": "CSAFPID-0044"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS400NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS401",
"product_id": "CSAFPID-0045"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS401"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS401NC",
"product_id": "CSAFPID-0046"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS401NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416",
"product_id": "CSAFPID-0047"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416NC",
"product_id": "CSAFPID-0048"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416NCv2 V4.X",
"product_id": "CSAFPID-0049"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416NCv2 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS416NCv2 V5.X",
"product_id": "CSAFPID-0050"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416NCv2 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416P",
"product_id": "CSAFPID-0051"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416PNC",
"product_id": "CSAFPID-0052"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416PNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416PNCv2 V4.X",
"product_id": "CSAFPID-0053"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416PNCv2 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS416PNCv2 V5.X",
"product_id": "CSAFPID-0054"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416PNCv2 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416Pv2 V4.X",
"product_id": "CSAFPID-0055"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416Pv2 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS416Pv2 V5.X",
"product_id": "CSAFPID-0056"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416Pv2 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS416v2 V4.X",
"product_id": "CSAFPID-0057"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416v2 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS416v2 V5.X",
"product_id": "CSAFPID-0058"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS416v2 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000",
"product_id": "CSAFPID-0059"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000A",
"product_id": "CSAFPID-0060"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000A"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000ANC",
"product_id": "CSAFPID-0061"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000ANC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000H",
"product_id": "CSAFPID-0062"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000H"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000HNC",
"product_id": "CSAFPID-0063"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000HNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000NC",
"product_id": "CSAFPID-0064"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000T",
"product_id": "CSAFPID-0065"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000T"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS8000TNC",
"product_id": "CSAFPID-0066"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS8000TNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900",
"product_id": "CSAFPID-0067"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900 (32M) V4.X",
"product_id": "CSAFPID-0068"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900 (32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS900 (32M) V5.X",
"product_id": "CSAFPID-0069"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900 (32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900G",
"product_id": "CSAFPID-0070"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900G"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900G (32M) V4.X",
"product_id": "CSAFPID-0071"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900G (32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS900G (32M) V5.X",
"product_id": "CSAFPID-0072"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900G (32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900GNC",
"product_id": "CSAFPID-0073"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900GNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900GNC(32M) V4.X",
"product_id": "CSAFPID-0074"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900GNC(32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS900GNC(32M) V5.X",
"product_id": "CSAFPID-0075"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900GNC(32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900GP",
"product_id": "CSAFPID-0076"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900GP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900GPNC",
"product_id": "CSAFPID-0077"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900GPNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900L",
"product_id": "CSAFPID-0078"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900L"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900LNC",
"product_id": "CSAFPID-0079"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900LNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900M-GETS-C01",
"product_id": "CSAFPID-0080"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900M-GETS-C01"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900M-GETS-XX",
"product_id": "CSAFPID-0081"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900M-GETS-XX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900M-STND-C01",
"product_id": "CSAFPID-0082"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900M-STND-C01"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900M-STND-XX",
"product_id": "CSAFPID-0083"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900M-STND-XX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900MNC-GETS-C01",
"product_id": "CSAFPID-0084"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900MNC-GETS-C01"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900MNC-GETS-XX",
"product_id": "CSAFPID-0085"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900MNC-GETS-XX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900MNC-STND-XX",
"product_id": "CSAFPID-0086"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900MNC-STND-XX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900MNC-STND-XX-C01",
"product_id": "CSAFPID-0087"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900MNC-STND-XX-C01"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900NC",
"product_id": "CSAFPID-0088"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900NC(32M) V4.X",
"product_id": "CSAFPID-0089"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900NC(32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RS900NC(32M) V5.X",
"product_id": "CSAFPID-0090"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900NC(32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS900W",
"product_id": "CSAFPID-0091"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS900W"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS910",
"product_id": "CSAFPID-0092"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS910"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS910L",
"product_id": "CSAFPID-0093"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS910L"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS910LNC",
"product_id": "CSAFPID-0094"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS910LNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS910NC",
"product_id": "CSAFPID-0095"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS910NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS910W",
"product_id": "CSAFPID-0096"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS910W"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS920L",
"product_id": "CSAFPID-0097"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS920L"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS920LNC",
"product_id": "CSAFPID-0098"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS920LNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS920W",
"product_id": "CSAFPID-0099"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS920W"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS930L",
"product_id": "CSAFPID-0100"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS930L"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS930LNC",
"product_id": "CSAFPID-0101"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS930LNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS930W",
"product_id": "CSAFPID-0102"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS930W"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS940G",
"product_id": "CSAFPID-0103"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS940G"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS940GNC",
"product_id": "CSAFPID-0104"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS940GNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS969",
"product_id": "CSAFPID-0105"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS969"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RS969NC",
"product_id": "CSAFPID-0106"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RS969NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100",
"product_id": "CSAFPID-0107"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100 (32M) V4.X",
"product_id": "CSAFPID-0108"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100 (32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2100 (32M) V5.X",
"product_id": "CSAFPID-0109"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100 (32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100NC",
"product_id": "CSAFPID-0110"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100NC(32M) V4.X",
"product_id": "CSAFPID-0111"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100NC(32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2100NC(32M) V5.X",
"product_id": "CSAFPID-0112"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100NC(32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100P",
"product_id": "CSAFPID-0113"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100P (32M) V4.X",
"product_id": "CSAFPID-0114"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100P (32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2100P (32M) V5.X",
"product_id": "CSAFPID-0115"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100P (32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100PNC",
"product_id": "CSAFPID-0116"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100PNC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2100PNC (32M) V4.X",
"product_id": "CSAFPID-0117"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100PNC (32M) V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2100PNC (32M) V5.X",
"product_id": "CSAFPID-0118"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2100PNC (32M) V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2200",
"product_id": "CSAFPID-0119"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2200"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2200NC",
"product_id": "CSAFPID-0120"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2200NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2288 V4.X",
"product_id": "CSAFPID-0121"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2288 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2288 V5.X",
"product_id": "CSAFPID-0122"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2288 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2288NC V4.X",
"product_id": "CSAFPID-0123"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2288NC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2288NC V5.X",
"product_id": "CSAFPID-0124"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2288NC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2300 V4.X",
"product_id": "CSAFPID-0125"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2300 V5.X",
"product_id": "CSAFPID-0126"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2300NC V4.X",
"product_id": "CSAFPID-0127"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300NC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2300NC V5.X",
"product_id": "CSAFPID-0128"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300NC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2300P V4.X",
"product_id": "CSAFPID-0129"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300P V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2300P V5.X",
"product_id": "CSAFPID-0130"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300P V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2300PNC V4.X",
"product_id": "CSAFPID-0131"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300PNC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2300PNC V5.X",
"product_id": "CSAFPID-0132"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2300PNC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2488 V4.X",
"product_id": "CSAFPID-0133"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2488 V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2488 V5.X",
"product_id": "CSAFPID-0134"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2488 V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG2488NC V4.X",
"product_id": "CSAFPID-0135"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2488NC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG2488NC V5.X",
"product_id": "CSAFPID-0136"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG2488NC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG907R",
"product_id": "CSAFPID-0137"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG907R"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG908C",
"product_id": "CSAFPID-0138"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG908C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG909R",
"product_id": "CSAFPID-0139"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG909R"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG910C",
"product_id": "CSAFPID-0140"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG910C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG920P V4.X",
"product_id": "CSAFPID-0141"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG920P V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG920P V5.X",
"product_id": "CSAFPID-0142"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG920P V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.3.11",
"product": {
"name": "RUGGEDCOM RSG920PNC V4.X",
"product_id": "CSAFPID-0143"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG920PNC V4.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSG920PNC V5.X",
"product_id": "CSAFPID-0144"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSG920PNC V5.X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSL910",
"product_id": "CSAFPID-0145"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSL910"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RSL910NC",
"product_id": "CSAFPID-0146"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RSL910NC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RST2228",
"product_id": "CSAFPID-0147"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RST2228"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RST2228P",
"product_id": "CSAFPID-0148"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RST2228P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "RUGGEDCOM RST2428P (6GK6242-6PA00)",
"product_id": "CSAFPID-0149",
"product_identification_helper": {
"model_numbers": [
"6GK6242-6PA00"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RST2428P (6GK6242-6PA00)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RST916C",
"product_id": "CSAFPID-0150"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RST916C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.10.0",
"product": {
"name": "RUGGEDCOM RST916P",
"product_id": "CSAFPID-0151"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RST916P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)",
"product_id": "CSAFPID-0152",
"product_identification_helper": {
"model_numbers": [
"6GK5804-0AP00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)",
"product_id": "CSAFPID-0153",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)",
"product_id": "CSAFPID-0154",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)",
"product_id": "CSAFPID-0155",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)",
"product_id": "CSAFPID-0156",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)",
"product_id": "CSAFPID-0157",
"product_identification_helper": {
"model_numbers": [
"6GK5826-2AB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)",
"product_id": "CSAFPID-0158",
"product_identification_helper": {
"model_numbers": [
"6GK5874-2AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)",
"product_id": "CSAFPID-0159",
"product_identification_helper": {
"model_numbers": [
"6GK5874-3AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)",
"product_id": "CSAFPID-0160",
"product_identification_helper": {
"model_numbers": [
"6GK5874-3AA00-2FA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)",
"product_id": "CSAFPID-0161",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)",
"product_id": "CSAFPID-0162",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2EA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)",
"product_id": "CSAFPID-0163",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA10-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)",
"product_id": "CSAFPID-0164",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)",
"product_id": "CSAFPID-0165",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)",
"product_id": "CSAFPID-0166",
"product_identification_helper": {
"model_numbers": [
"6GK5853-2EA10-2AA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)",
"product_id": "CSAFPID-0167",
"product_identification_helper": {
"model_numbers": [
"6GK5853-2EA10-2BA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)",
"product_id": "CSAFPID-0168",
"product_identification_helper": {
"model_numbers": [
"6GK5853-2EA00-2DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)",
"product_id": "CSAFPID-0169",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA10-3AA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)",
"product_id": "CSAFPID-0170",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA10-3BA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)",
"product_id": "CSAFPID-0171",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3FA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)",
"product_id": "CSAFPID-0172",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)",
"product_id": "CSAFPID-0173",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3AA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)",
"product_id": "CSAFPID-0174",
"product_identification_helper": {
"model_numbers": [
"6GK5615-0AA01-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c8.2",
"product": {
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)",
"product_id": "CSAFPID-0175",
"product_identification_helper": {
"model_numbers": [
"6GK5615-0AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)",
"product_id": "CSAFPID-0176",
"product_identification_helper": {
"model_numbers": [
"6GK5622-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)",
"product_id": "CSAFPID-0177",
"product_identification_helper": {
"model_numbers": [
"6GK5626-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)",
"product_id": "CSAFPID-0178",
"product_identification_helper": {
"model_numbers": [
"6GK5632-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)",
"product_id": "CSAFPID-0179",
"product_identification_helper": {
"model_numbers": [
"6GK5636-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)",
"product_id": "CSAFPID-0180",
"product_identification_helper": {
"model_numbers": [
"6GK5642-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)",
"product_id": "CSAFPID-0181",
"product_identification_helper": {
"model_numbers": [
"6GK5646-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)",
"product_id": "CSAFPID-0182",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)",
"product_id": "CSAFPID-0183",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)",
"product_id": "CSAFPID-0184",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)",
"product_id": "CSAFPID-0185",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)",
"product_id": "CSAFPID-0186",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)",
"product_id": "CSAFPID-0187",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2HY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)",
"product_id": "CSAFPID-0188",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)",
"product_id": "CSAFPID-0189",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)",
"product_id": "CSAFPID-0190",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)",
"product_id": "CSAFPID-0191",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)",
"product_id": "CSAFPID-0192",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)",
"product_id": "CSAFPID-0193",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)",
"product_id": "CSAFPID-0194",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)",
"product_id": "CSAFPID-0195",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)",
"product_id": "CSAFPID-0196",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)",
"product_id": "CSAFPID-0197",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)",
"product_id": "CSAFPID-0198",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)",
"product_id": "CSAFPID-0199",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)",
"product_id": "CSAFPID-0200",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)",
"product_id": "CSAFPID-0201",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)",
"product_id": "CSAFPID-0202",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)",
"product_id": "CSAFPID-0203",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)",
"product_id": "CSAFPID-0204",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)",
"product_id": "CSAFPID-0205",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)",
"product_id": "CSAFPID-0206",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)",
"product_id": "CSAFPID-0207",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)",
"product_id": "CSAFPID-0208",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)",
"product_id": "CSAFPID-0209",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)",
"product_id": "CSAFPID-0210",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)",
"product_id": "CSAFPID-0211",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)",
"product_id": "CSAFPID-0212",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)",
"product_id": "CSAFPID-0213",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)",
"product_id": "CSAFPID-0214",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)",
"product_id": "CSAFPID-0215",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)",
"product_id": "CSAFPID-0216",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)",
"product_id": "CSAFPID-0217",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)",
"product_id": "CSAFPID-0218",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)",
"product_id": "CSAFPID-0219",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)",
"product_id": "CSAFPID-0220",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)",
"product_id": "CSAFPID-0221",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)",
"product_id": "CSAFPID-0222",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)",
"product_id": "CSAFPID-0223",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)",
"product_id": "CSAFPID-0224",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)",
"product_id": "CSAFPID-0225",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)",
"product_id": "CSAFPID-0226",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)",
"product_id": "CSAFPID-0227",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)",
"product_id": "CSAFPID-0228",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)",
"product_id": "CSAFPID-0229",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)",
"product_id": "CSAFPID-0230",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)",
"product_id": "CSAFPID-0231",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)",
"product_id": "CSAFPID-0232",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)",
"product_id": "CSAFPID-0233",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)",
"product_id": "CSAFPID-0234",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)",
"product_id": "CSAFPID-0235",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)",
"product_id": "CSAFPID-0236",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)",
"product_id": "CSAFPID-0237",
"product_identification_helper": {
"model_numbers": [
"6GK5762-1AJ00-6AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)",
"product_id": "CSAFPID-0238",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)",
"product_id": "CSAFPID-0239",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-7DC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)",
"product_id": "CSAFPID-0240",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-7DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)",
"product_id": "CSAFPID-0241",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)",
"product_id": "CSAFPID-0242",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)",
"product_id": "CSAFPID-0243",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)",
"product_id": "CSAFPID-0244",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)",
"product_id": "CSAFPID-0245",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)",
"product_id": "CSAFPID-0246",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)",
"product_id": "CSAFPID-0247",
"product_identification_helper": {
"model_numbers": [
"6GK5762-1AJ00-1AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)",
"product_id": "CSAFPID-0248",
"product_identification_helper": {
"model_numbers": [
"6GK5762-1AJ00-2AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)",
"product_id": "CSAFPID-0249",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)",
"product_id": "CSAFPID-0250",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)",
"product_id": "CSAFPID-0251",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)",
"product_id": "CSAFPID-0252",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)",
"product_id": "CSAFPID-0253",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)",
"product_id": "CSAFPID-0254",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.0.0",
"product": {
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)",
"product_id": "CSAFPID-0255",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)",
"product_id": "CSAFPID-0256",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)",
"product_id": "CSAFPID-0257",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)",
"product_id": "CSAFPID-0258",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)",
"product_id": "CSAFPID-0259",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)",
"product_id": "CSAFPID-0260",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)",
"product_id": "CSAFPID-0261",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)",
"product_id": "CSAFPID-0262",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)",
"product_id": "CSAFPID-0263",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)",
"product_id": "CSAFPID-0264",
"product_identification_helper": {
"model_numbers": [
"6GK5304-2BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)",
"product_id": "CSAFPID-0265",
"product_identification_helper": {
"model_numbers": [
"6GK5306-1BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)",
"product_id": "CSAFPID-0266",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)",
"product_id": "CSAFPID-0267",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)",
"product_id": "CSAFPID-0268",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)",
"product_id": "CSAFPID-0269",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)",
"product_id": "CSAFPID-0270",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)",
"product_id": "CSAFPID-0271",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)",
"product_id": "CSAFPID-0272",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)",
"product_id": "CSAFPID-0273",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)",
"product_id": "CSAFPID-0274",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)",
"product_id": "CSAFPID-0275",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)",
"product_id": "CSAFPID-0276",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)",
"product_id": "CSAFPID-0277",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)",
"product_id": "CSAFPID-0278",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)",
"product_id": "CSAFPID-0279",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)",
"product_id": "CSAFPID-0280",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)",
"product_id": "CSAFPID-0281",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)",
"product_id": "CSAFPID-0282",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)",
"product_id": "CSAFPID-0283",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)",
"product_id": "CSAFPID-0284",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)",
"product_id": "CSAFPID-0285",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)",
"product_id": "CSAFPID-0286",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)",
"product_id": "CSAFPID-0287",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)",
"product_id": "CSAFPID-0288",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)",
"product_id": "CSAFPID-0289",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)",
"product_id": "CSAFPID-0290",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)",
"product_id": "CSAFPID-0291",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)",
"product_id": "CSAFPID-0292",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)",
"product_id": "CSAFPID-0293",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)",
"product_id": "CSAFPID-0294",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)",
"product_id": "CSAFPID-0295",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)",
"product_id": "CSAFPID-0296",
"product_identification_helper": {
"model_numbers": [
"6GK5320-1BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)",
"product_id": "CSAFPID-0297",
"product_identification_helper": {
"model_numbers": [
"6GK5320-3BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)",
"product_id": "CSAFPID-0298",
"product_identification_helper": {
"model_numbers": [
"6GK5408-2FD00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)",
"product_id": "CSAFPID-0299",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)",
"product_id": "CSAFPID-0300",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)",
"product_id": "CSAFPID-0301",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)",
"product_id": "CSAFPID-0302",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)",
"product_id": "CSAFPID-0303",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)",
"product_id": "CSAFPID-0304",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2 (SC) (6GK5206-2BD00-2TB2)",
"product_id": "CSAFPID-0305",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2 (SC) (6GK5206-2BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2 (ST/BFOC) (6GK5206-2BF00-2TB2)",
"product_id": "CSAFPID-0306",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2 (ST/BFOC) (6GK5206-2BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2 LD (6GK5206-2BF00-2AB2)",
"product_id": "CSAFPID-0307",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2 LD (6GK5206-2BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2 SC (6GK5206-2BD00-2AB2)",
"product_id": "CSAFPID-0308",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2 SC (6GK5206-2BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2 ST (6GK5206-2BB00-2AB2)",
"product_id": "CSAFPID-0309",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2 ST (6GK5206-2BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB206-2LD (6GK5206-2BB00-2TB2)",
"product_id": "CSAFPID-0310",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB206-2LD (6GK5206-2BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)",
"product_id": "CSAFPID-0311",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)",
"product_id": "CSAFPID-0312",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)",
"product_id": "CSAFPID-0313",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)",
"product_id": "CSAFPID-0314",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)",
"product_id": "CSAFPID-0315",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)",
"product_id": "CSAFPID-0316",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)",
"product_id": "CSAFPID-0317",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)",
"product_id": "CSAFPID-0318",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)",
"product_id": "CSAFPID-0319",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)",
"product_id": "CSAFPID-0320",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)",
"product_id": "CSAFPID-0321",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BD00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)",
"product_id": "CSAFPID-0322",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BB00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)",
"product_id": "CSAFPID-0323",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)",
"product_id": "CSAFPID-0324",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)",
"product_id": "CSAFPID-0325",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)",
"product_id": "CSAFPID-0326",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)",
"product_id": "CSAFPID-0327",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)",
"product_id": "CSAFPID-0328",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)",
"product_id": "CSAFPID-0329",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)",
"product_id": "CSAFPID-0330",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)",
"product_id": "CSAFPID-0331",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)",
"product_id": "CSAFPID-0332",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)",
"product_id": "CSAFPID-0333",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)",
"product_id": "CSAFPID-0334",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)",
"product_id": "CSAFPID-0335",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)",
"product_id": "CSAFPID-0336",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)",
"product_id": "CSAFPID-0337",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)",
"product_id": "CSAFPID-0338",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)",
"product_id": "CSAFPID-0339",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)",
"product_id": "CSAFPID-0340",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)",
"product_id": "CSAFPID-0341",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)",
"product_id": "CSAFPID-0342",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)",
"product_id": "CSAFPID-0343",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)",
"product_id": "CSAFPID-0344",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)",
"product_id": "CSAFPID-0345",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)",
"product_id": "CSAFPID-0346",
"product_identification_helper": {
"model_numbers": [
"6GK5224-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)",
"product_id": "CSAFPID-0347",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)",
"product_id": "CSAFPID-0348",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)",
"product_id": "CSAFPID-0349",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC316-8 (6GK5324-8TS00-2AC2)",
"product_id": "CSAFPID-0350",
"product_identification_helper": {
"model_numbers": [
"6GK5324-8TS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC316-8 (6GK5324-8TS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC324-4 (6GK5328-4TS00-2AC2)",
"product_id": "CSAFPID-0351",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC324-4 (6GK5328-4TS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2)",
"product_id": "CSAFPID-0352",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS00-2EC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC332 (6GK5332-0GA00-2AC2)",
"product_id": "CSAFPID-0353",
"product_identification_helper": {
"model_numbers": [
"6GK5332-0GA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC332 (6GK5332-0GA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC416-8 (6GK5424-8TR00-2AC2)",
"product_id": "CSAFPID-0354",
"product_identification_helper": {
"model_numbers": [
"6GK5424-8TR00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC416-8 (6GK5424-8TR00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC424-4 (6GK5428-4TR00-2AC2)",
"product_id": "CSAFPID-0355",
"product_identification_helper": {
"model_numbers": [
"6GK5428-4TR00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC424-4 (6GK5428-4TR00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XC432 (6GK5432-0GR00-2AC2)",
"product_id": "CSAFPID-0356",
"product_identification_helper": {
"model_numbers": [
"6GK5432-0GR00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC432 (6GK5432-0GR00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)",
"product_id": "CSAFPID-0357",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS01-2EC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)",
"product_id": "CSAFPID-0358",
"product_identification_helper": {
"model_numbers": [
"6GK5324-8TS01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)",
"product_id": "CSAFPID-0359",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)",
"product_id": "CSAFPID-0360",
"product_identification_helper": {
"model_numbers": [
"6GK5332-0GA01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)",
"product_id": "CSAFPID-0361",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)",
"product_id": "CSAFPID-0362",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)",
"product_id": "CSAFPID-0363",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)",
"product_id": "CSAFPID-0364",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XF204G (6GK5204-0GA00-1UF2)",
"product_id": "CSAFPID-0365",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0GA00-1UF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204G (6GK5204-0GA00-1UF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)",
"product_id": "CSAFPID-0366",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GP00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)",
"product_id": "CSAFPID-0367",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GQ00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)",
"product_id": "CSAFPID-0368",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)",
"product_id": "CSAFPID-0369",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)",
"product_id": "CSAFPID-0370",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)",
"product_id": "CSAFPID-0371",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)",
"product_id": "CSAFPID-0372",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208 (6GK5208-0HA10-2AS6)",
"product_id": "CSAFPID-0373",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA10-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (6GK5208-0HA10-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)",
"product_id": "CSAFPID-0374",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)",
"product_id": "CSAFPID-0375",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208EEC (6GK5208-0HA10-2ES6)",
"product_id": "CSAFPID-0376",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA10-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208EEC (6GK5208-0HA10-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208G (6GK5208-0XA00-2AS6)",
"product_id": "CSAFPID-0377",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0XA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208G (6GK5208-0XA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208G EEC (6GK5208-0XA00-2ES6)",
"product_id": "CSAFPID-0378",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0XA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208G EEC (6GK5208-0XA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208G PoE EEC (6GK5208-0YA00-5ES6)",
"product_id": "CSAFPID-0379",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0YA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208G PoE EEC (6GK5208-0YA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208G PP (6GK5208-0JA00-2AS6)",
"product_id": "CSAFPID-0380",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0JA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208G PP (6GK5208-0JA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)",
"product_id": "CSAFPID-0381",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA10-5ES6)",
"product_id": "CSAFPID-0382",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0UA10-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA10-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)",
"product_id": "CSAFPID-0383",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)",
"product_id": "CSAFPID-0384",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216 (V2) (6GK5216-0HA10-2AS6)",
"product_id": "CSAFPID-0385",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA10-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (V2) (6GK5216-0HA10-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)",
"product_id": "CSAFPID-0386",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216EEC (V2) (6GK5216-0HA10-2ES6)",
"product_id": "CSAFPID-0387",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA10-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216EEC (V2) (6GK5216-0HA10-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216G (6GK5216-0XA00-2AS6)",
"product_id": "CSAFPID-0388",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0XA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216G (6GK5216-0XA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216G EEC (6GK5216-0XA00-2ES6)",
"product_id": "CSAFPID-0389",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0XA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216G EEC (6GK5216-0XA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216G PoE EEC (6GK5216-0YA00-5ES6)",
"product_id": "CSAFPID-0390",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0YA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216G PoE EEC (6GK5216-0YA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)",
"product_id": "CSAFPID-0391",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XP216PoE EEC (V2) (6GK5216-0UA10-5ES6)",
"product_id": "CSAFPID-0392",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0UA10-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216PoE EEC (V2) (6GK5216-0UA10-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR302-32 (6GK5334-5TS00-2AR3)",
"product_id": "CSAFPID-0393",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR302-32 (6GK5334-5TS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR302-32 (6GK5334-5TS00-3AR3)",
"product_id": "CSAFPID-0394",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR302-32 (6GK5334-5TS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR302-32 (6GK5334-5TS00-4AR3)",
"product_id": "CSAFPID-0395",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR302-32 (6GK5334-5TS00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR322-12 (6GK5334-3TS00-2AR3)",
"product_id": "CSAFPID-0396",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR322-12 (6GK5334-3TS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR322-12 (6GK5334-3TS00-3AR3)",
"product_id": "CSAFPID-0397",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR322-12 (6GK5334-3TS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR322-12 (6GK5334-3TS00-4AR3)",
"product_id": "CSAFPID-0398",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR322-12 (6GK5334-3TS00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)",
"product_id": "CSAFPID-0399",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)",
"product_id": "CSAFPID-0400",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)",
"product_id": "CSAFPID-0401",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)",
"product_id": "CSAFPID-0402",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)",
"product_id": "CSAFPID-0403",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)",
"product_id": "CSAFPID-0404",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)",
"product_id": "CSAFPID-0405",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)",
"product_id": "CSAFPID-0406",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)",
"product_id": "CSAFPID-0407",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)",
"product_id": "CSAFPID-0408",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)",
"product_id": "CSAFPID-0409",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)",
"product_id": "CSAFPID-0410",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)",
"product_id": "CSAFPID-0411",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)",
"product_id": "CSAFPID-0412",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)",
"product_id": "CSAFPID-0413",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)",
"product_id": "CSAFPID-0414",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)",
"product_id": "CSAFPID-0415",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)",
"product_id": "CSAFPID-0416",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)",
"product_id": "CSAFPID-0417",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)",
"product_id": "CSAFPID-0418",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)",
"product_id": "CSAFPID-0419",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)",
"product_id": "CSAFPID-0420",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)",
"product_id": "CSAFPID-0421",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)",
"product_id": "CSAFPID-0422",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)",
"product_id": "CSAFPID-0423",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)",
"product_id": "CSAFPID-0424",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)",
"product_id": "CSAFPID-0425",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)",
"product_id": "CSAFPID-0426",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG10-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)",
"product_id": "CSAFPID-0427",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)",
"product_id": "CSAFPID-0428",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG10-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)",
"product_id": "CSAFPID-0429",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)",
"product_id": "CSAFPID-0430",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG10-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)",
"product_id": "CSAFPID-0431",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)",
"product_id": "CSAFPID-0432",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG10-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)",
"product_id": "CSAFPID-0433",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)",
"product_id": "CSAFPID-0434",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG10-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)",
"product_id": "CSAFPID-0435",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)",
"product_id": "CSAFPID-0436",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)",
"product_id": "CSAFPID-0437",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)",
"product_id": "CSAFPID-0438",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR326-8 (6GK5334-2TS00-2AR3)",
"product_id": "CSAFPID-0439",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-8 (6GK5334-2TS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR326-8 (6GK5334-2TS00-3AR3)",
"product_id": "CSAFPID-0440",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-8 (6GK5334-2TS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR326-8 (6GK5334-2TS00-4AR3)",
"product_id": "CSAFPID-0441",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-8 (6GK5334-2TS00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3)",
"product_id": "CSAFPID-0442",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS00-2ER3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)",
"product_id": "CSAFPID-0443",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)",
"product_id": "CSAFPID-0444",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)",
"product_id": "CSAFPID-0445",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)",
"product_id": "CSAFPID-0446",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)",
"product_id": "CSAFPID-0447",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)",
"product_id": "CSAFPID-0448",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR502-32 (6GK5534-5TR00-2AR3)",
"product_id": "CSAFPID-0449",
"product_identification_helper": {
"model_numbers": [
"6GK5534-5TR00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR502-32 (6GK5534-5TR00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR502-32 (6GK5534-5TR00-3AR3)",
"product_id": "CSAFPID-0450",
"product_identification_helper": {
"model_numbers": [
"6GK5534-5TR00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR502-32 (6GK5534-5TR00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR502-32 (6GK5534-5TR00-4AR3)",
"product_id": "CSAFPID-0451",
"product_identification_helper": {
"model_numbers": [
"6GK5534-5TR00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR502-32 (6GK5534-5TR00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR522-12 (6GK5534-3TR00-2AR3)",
"product_id": "CSAFPID-0452",
"product_identification_helper": {
"model_numbers": [
"6GK5534-3TR00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR522-12 (6GK5534-3TR00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR522-12 (6GK5534-3TR00-3AR3)",
"product_id": "CSAFPID-0453",
"product_identification_helper": {
"model_numbers": [
"6GK5534-3TR00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR522-12 (6GK5534-3TR00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR522-12 (6GK5534-3TR00-4AR3)",
"product_id": "CSAFPID-0454",
"product_identification_helper": {
"model_numbers": [
"6GK5534-3TR00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR522-12 (6GK5534-3TR00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)",
"product_id": "CSAFPID-0455",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)",
"product_id": "CSAFPID-0456",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)",
"product_id": "CSAFPID-0457",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)",
"product_id": "CSAFPID-0458",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)",
"product_id": "CSAFPID-0459",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)",
"product_id": "CSAFPID-0460",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-2AR3)",
"product_id": "CSAFPID-0461",
"product_identification_helper": {
"model_numbers": [
"6GK5532-2SR00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-2RR3)",
"product_id": "CSAFPID-0462",
"product_identification_helper": {
"model_numbers": [
"6GK5532-2SR00-2RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-2RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-3AR3)",
"product_id": "CSAFPID-0463",
"product_identification_helper": {
"model_numbers": [
"6GK5532-2SR00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-3RR3)",
"product_id": "CSAFPID-0464",
"product_identification_helper": {
"model_numbers": [
"6GK5532-2SR00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8WG (6GK5532-2SR00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR526-8 (6GK5534-2TR00-2AR3)",
"product_id": "CSAFPID-0465",
"product_identification_helper": {
"model_numbers": [
"6GK5534-2TR00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8 (6GK5534-2TR00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR526-8 (6GK5534-2TR00-3AR3)",
"product_id": "CSAFPID-0466",
"product_identification_helper": {
"model_numbers": [
"6GK5534-2TR00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8 (6GK5534-2TR00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.3",
"product": {
"name": "SCALANCE XR526-8 (6GK5534-2TR00-4AR3)",
"product_id": "CSAFPID-0467",
"product_identification_helper": {
"model_numbers": [
"6GK5534-2TR00-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8 (6GK5534-2TR00-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)",
"product_id": "CSAFPID-0468",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)",
"product_id": "CSAFPID-0469",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)",
"product_id": "CSAFPID-0470",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)",
"product_id": "CSAFPID-0471",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)",
"product_id": "CSAFPID-0472",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)",
"product_id": "CSAFPID-0473",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)",
"product_id": "CSAFPID-0474",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)",
"product_id": "CSAFPID-0475",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)",
"product_id": "CSAFPID-0476",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)",
"product_id": "CSAFPID-0477",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)",
"product_id": "CSAFPID-0478",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)",
"product_id": "CSAFPID-0479",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)",
"product_id": "CSAFPID-0480",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)",
"product_id": "CSAFPID-0481",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)",
"product_id": "CSAFPID-0482",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-2ER3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)",
"product_id": "CSAFPID-0483",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)",
"product_id": "CSAFPID-0484",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)",
"product_id": "CSAFPID-0485",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS01-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)",
"product_id": "CSAFPID-0486",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)",
"product_id": "CSAFPID-0487",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)",
"product_id": "CSAFPID-0488",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS01-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)",
"product_id": "CSAFPID-0489",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)",
"product_id": "CSAFPID-0490",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.2",
"product": {
"name": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)",
"product_id": "CSAFPID-0491",
"product_identification_helper": {
"model_numbers": [
"6GK5334-5TS01-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c1.0.2.4",
"product": {
"name": "SINEC INS",
"product_id": "CSAFPID-0492"
}
}
],
"category": "product_name",
"name": "SINEC INS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.1.9",
"product": {
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)",
"product_id": "CSAFPID-0493",
"product_identification_helper": {
"model_numbers": [
"6AG1308-2FL10-4AA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)",
"product_id": "CSAFPID-0494",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BB00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)",
"product_id": "CSAFPID-0495",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)",
"product_id": "CSAFPID-0496",
"product_identification_helper": {
"model_numbers": [
"6AG1208-0BA00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.6",
"product": {
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)",
"product_id": "CSAFPID-0497",
"product_identification_helper": {
"model_numbers": [
"6AG1216-4BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "summary",
"text": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify responses Access-Reject or Access-Accept using a chosen-prefix collision attack against MD5 Response Authenticator signature.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185",
"CSAFPID-0186",
"CSAFPID-0187",
"CSAFPID-0188",
"CSAFPID-0189",
"CSAFPID-0190",
"CSAFPID-0191",
"CSAFPID-0192",
"CSAFPID-0193",
"CSAFPID-0194",
"CSAFPID-0195",
"CSAFPID-0196",
"CSAFPID-0197",
"CSAFPID-0198",
"CSAFPID-0199",
"CSAFPID-0200",
"CSAFPID-0201",
"CSAFPID-0202",
"CSAFPID-0203",
"CSAFPID-0204",
"CSAFPID-0205",
"CSAFPID-0206",
"CSAFPID-0207",
"CSAFPID-0208",
"CSAFPID-0209",
"CSAFPID-0210",
"CSAFPID-0211",
"CSAFPID-0212",
"CSAFPID-0213",
"CSAFPID-0214",
"CSAFPID-0215",
"CSAFPID-0216",
"CSAFPID-0217",
"CSAFPID-0218",
"CSAFPID-0219",
"CSAFPID-0220",
"CSAFPID-0221",
"CSAFPID-0222",
"CSAFPID-0223",
"CSAFPID-0224",
"CSAFPID-0225",
"CSAFPID-0226",
"CSAFPID-0227",
"CSAFPID-0228",
"CSAFPID-0229",
"CSAFPID-0230",
"CSAFPID-0231",
"CSAFPID-0232",
"CSAFPID-0233",
"CSAFPID-0234",
"CSAFPID-0235",
"CSAFPID-0236",
"CSAFPID-0237",
"CSAFPID-0238",
"CSAFPID-0239",
"CSAFPID-0240",
"CSAFPID-0241",
"CSAFPID-0242",
"CSAFPID-0243",
"CSAFPID-0244",
"CSAFPID-0245",
"CSAFPID-0246",
"CSAFPID-0247",
"CSAFPID-0248",
"CSAFPID-0249",
"CSAFPID-0250",
"CSAFPID-0251",
"CSAFPID-0252",
"CSAFPID-0253",
"CSAFPID-0254",
"CSAFPID-0255",
"CSAFPID-0256",
"CSAFPID-0257",
"CSAFPID-0258",
"CSAFPID-0259",
"CSAFPID-0260",
"CSAFPID-0261",
"CSAFPID-0262",
"CSAFPID-0263",
"CSAFPID-0264",
"CSAFPID-0265",
"CSAFPID-0266",
"CSAFPID-0267",
"CSAFPID-0268",
"CSAFPID-0269",
"CSAFPID-0270",
"CSAFPID-0271",
"CSAFPID-0272",
"CSAFPID-0273",
"CSAFPID-0274",
"CSAFPID-0275",
"CSAFPID-0276",
"CSAFPID-0277",
"CSAFPID-0278",
"CSAFPID-0279",
"CSAFPID-0280",
"CSAFPID-0281",
"CSAFPID-0282",
"CSAFPID-0283",
"CSAFPID-0284",
"CSAFPID-0285",
"CSAFPID-0286",
"CSAFPID-0287",
"CSAFPID-0288",
"CSAFPID-0289",
"CSAFPID-0290",
"CSAFPID-0291",
"CSAFPID-0292",
"CSAFPID-0293",
"CSAFPID-0294",
"CSAFPID-0295",
"CSAFPID-0296",
"CSAFPID-0297",
"CSAFPID-0298",
"CSAFPID-0299",
"CSAFPID-0300",
"CSAFPID-0301",
"CSAFPID-0302",
"CSAFPID-0303",
"CSAFPID-0304",
"CSAFPID-0305",
"CSAFPID-0306",
"CSAFPID-0307",
"CSAFPID-0308",
"CSAFPID-0309",
"CSAFPID-0310",
"CSAFPID-0311",
"CSAFPID-0312",
"CSAFPID-0313",
"CSAFPID-0314",
"CSAFPID-0315",
"CSAFPID-0316",
"CSAFPID-0317",
"CSAFPID-0318",
"CSAFPID-0319",
"CSAFPID-0320",
"CSAFPID-0321",
"CSAFPID-0322",
"CSAFPID-0323",
"CSAFPID-0324",
"CSAFPID-0325",
"CSAFPID-0326",
"CSAFPID-0327",
"CSAFPID-0328",
"CSAFPID-0329",
"CSAFPID-0330",
"CSAFPID-0331",
"CSAFPID-0332",
"CSAFPID-0333",
"CSAFPID-0334",
"CSAFPID-0335",
"CSAFPID-0336",
"CSAFPID-0337",
"CSAFPID-0338",
"CSAFPID-0339",
"CSAFPID-0340",
"CSAFPID-0341",
"CSAFPID-0342",
"CSAFPID-0343",
"CSAFPID-0344",
"CSAFPID-0345",
"CSAFPID-0346",
"CSAFPID-0347",
"CSAFPID-0348",
"CSAFPID-0349",
"CSAFPID-0350",
"CSAFPID-0351",
"CSAFPID-0352",
"CSAFPID-0353",
"CSAFPID-0354",
"CSAFPID-0355",
"CSAFPID-0356",
"CSAFPID-0357",
"CSAFPID-0358",
"CSAFPID-0359",
"CSAFPID-0360",
"CSAFPID-0361",
"CSAFPID-0362",
"CSAFPID-0363",
"CSAFPID-0364",
"CSAFPID-0365",
"CSAFPID-0366",
"CSAFPID-0367",
"CSAFPID-0368",
"CSAFPID-0369",
"CSAFPID-0370",
"CSAFPID-0371",
"CSAFPID-0372",
"CSAFPID-0373",
"CSAFPID-0374",
"CSAFPID-0375",
"CSAFPID-0376",
"CSAFPID-0377",
"CSAFPID-0378",
"CSAFPID-0379",
"CSAFPID-0380",
"CSAFPID-0381",
"CSAFPID-0382",
"CSAFPID-0383",
"CSAFPID-0384",
"CSAFPID-0385",
"CSAFPID-0386",
"CSAFPID-0387",
"CSAFPID-0388",
"CSAFPID-0389",
"CSAFPID-0390",
"CSAFPID-0391",
"CSAFPID-0392",
"CSAFPID-0393",
"CSAFPID-0394",
"CSAFPID-0395",
"CSAFPID-0396",
"CSAFPID-0397",
"CSAFPID-0398",
"CSAFPID-0399",
"CSAFPID-0400",
"CSAFPID-0401",
"CSAFPID-0402",
"CSAFPID-0403",
"CSAFPID-0404",
"CSAFPID-0405",
"CSAFPID-0406",
"CSAFPID-0407",
"CSAFPID-0408",
"CSAFPID-0409",
"CSAFPID-0410",
"CSAFPID-0411",
"CSAFPID-0412",
"CSAFPID-0413",
"CSAFPID-0414",
"CSAFPID-0415",
"CSAFPID-0416",
"CSAFPID-0417",
"CSAFPID-0418",
"CSAFPID-0419",
"CSAFPID-0420",
"CSAFPID-0421",
"CSAFPID-0422",
"CSAFPID-0423",
"CSAFPID-0424",
"CSAFPID-0425",
"CSAFPID-0426",
"CSAFPID-0427",
"CSAFPID-0428",
"CSAFPID-0429",
"CSAFPID-0430",
"CSAFPID-0431",
"CSAFPID-0432",
"CSAFPID-0433",
"CSAFPID-0434",
"CSAFPID-0435",
"CSAFPID-0436",
"CSAFPID-0437",
"CSAFPID-0438",
"CSAFPID-0439",
"CSAFPID-0440",
"CSAFPID-0441",
"CSAFPID-0442",
"CSAFPID-0443",
"CSAFPID-0444",
"CSAFPID-0445",
"CSAFPID-0446",
"CSAFPID-0447",
"CSAFPID-0448",
"CSAFPID-0449",
"CSAFPID-0450",
"CSAFPID-0451",
"CSAFPID-0452",
"CSAFPID-0453",
"CSAFPID-0454",
"CSAFPID-0455",
"CSAFPID-0456",
"CSAFPID-0457",
"CSAFPID-0458",
"CSAFPID-0459",
"CSAFPID-0460",
"CSAFPID-0461",
"CSAFPID-0462",
"CSAFPID-0463",
"CSAFPID-0464",
"CSAFPID-0465",
"CSAFPID-0466",
"CSAFPID-0467",
"CSAFPID-0468",
"CSAFPID-0469",
"CSAFPID-0470",
"CSAFPID-0471",
"CSAFPID-0472",
"CSAFPID-0473",
"CSAFPID-0474",
"CSAFPID-0475",
"CSAFPID-0476",
"CSAFPID-0477",
"CSAFPID-0478",
"CSAFPID-0479",
"CSAFPID-0480",
"CSAFPID-0481",
"CSAFPID-0482",
"CSAFPID-0483",
"CSAFPID-0484",
"CSAFPID-0485",
"CSAFPID-0486",
"CSAFPID-0487",
"CSAFPID-0488",
"CSAFPID-0489",
"CSAFPID-0490",
"CSAFPID-0491",
"CSAFPID-0492",
"CSAFPID-0493",
"CSAFPID-0494",
"CSAFPID-0495",
"CSAFPID-0496",
"CSAFPID-0497"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/924.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185",
"CSAFPID-0186",
"CSAFPID-0187",
"CSAFPID-0188",
"CSAFPID-0189",
"CSAFPID-0190",
"CSAFPID-0191",
"CSAFPID-0192",
"CSAFPID-0193",
"CSAFPID-0194",
"CSAFPID-0195",
"CSAFPID-0196",
"CSAFPID-0197",
"CSAFPID-0198",
"CSAFPID-0199",
"CSAFPID-0200",
"CSAFPID-0201",
"CSAFPID-0202",
"CSAFPID-0203",
"CSAFPID-0204",
"CSAFPID-0205",
"CSAFPID-0206",
"CSAFPID-0207",
"CSAFPID-0208",
"CSAFPID-0209",
"CSAFPID-0210",
"CSAFPID-0211",
"CSAFPID-0212",
"CSAFPID-0213",
"CSAFPID-0214",
"CSAFPID-0215",
"CSAFPID-0216",
"CSAFPID-0217",
"CSAFPID-0218",
"CSAFPID-0219",
"CSAFPID-0220",
"CSAFPID-0221",
"CSAFPID-0222",
"CSAFPID-0223",
"CSAFPID-0224",
"CSAFPID-0225",
"CSAFPID-0226",
"CSAFPID-0227",
"CSAFPID-0228",
"CSAFPID-0229",
"CSAFPID-0230",
"CSAFPID-0231",
"CSAFPID-0232",
"CSAFPID-0233",
"CSAFPID-0234",
"CSAFPID-0235",
"CSAFPID-0236",
"CSAFPID-0237",
"CSAFPID-0238",
"CSAFPID-0239",
"CSAFPID-0240",
"CSAFPID-0241",
"CSAFPID-0242",
"CSAFPID-0243",
"CSAFPID-0244",
"CSAFPID-0245",
"CSAFPID-0246",
"CSAFPID-0247",
"CSAFPID-0248",
"CSAFPID-0249",
"CSAFPID-0250",
"CSAFPID-0251",
"CSAFPID-0252",
"CSAFPID-0253",
"CSAFPID-0254",
"CSAFPID-0255",
"CSAFPID-0256",
"CSAFPID-0257",
"CSAFPID-0258",
"CSAFPID-0259",
"CSAFPID-0260",
"CSAFPID-0261",
"CSAFPID-0262",
"CSAFPID-0263",
"CSAFPID-0264",
"CSAFPID-0265",
"CSAFPID-0266",
"CSAFPID-0267",
"CSAFPID-0268",
"CSAFPID-0269",
"CSAFPID-0270",
"CSAFPID-0271",
"CSAFPID-0272",
"CSAFPID-0273",
"CSAFPID-0274",
"CSAFPID-0275",
"CSAFPID-0276",
"CSAFPID-0277",
"CSAFPID-0278",
"CSAFPID-0279",
"CSAFPID-0280",
"CSAFPID-0281",
"CSAFPID-0282",
"CSAFPID-0283",
"CSAFPID-0284",
"CSAFPID-0285",
"CSAFPID-0286",
"CSAFPID-0287",
"CSAFPID-0288",
"CSAFPID-0289",
"CSAFPID-0290",
"CSAFPID-0291",
"CSAFPID-0292",
"CSAFPID-0293",
"CSAFPID-0294",
"CSAFPID-0295",
"CSAFPID-0296",
"CSAFPID-0297",
"CSAFPID-0298",
"CSAFPID-0299",
"CSAFPID-0300",
"CSAFPID-0301",
"CSAFPID-0302",
"CSAFPID-0303",
"CSAFPID-0304",
"CSAFPID-0305",
"CSAFPID-0306",
"CSAFPID-0307",
"CSAFPID-0308",
"CSAFPID-0309",
"CSAFPID-0310",
"CSAFPID-0311",
"CSAFPID-0312",
"CSAFPID-0313",
"CSAFPID-0314",
"CSAFPID-0315",
"CSAFPID-0316",
"CSAFPID-0317",
"CSAFPID-0318",
"CSAFPID-0319",
"CSAFPID-0320",
"CSAFPID-0321",
"CSAFPID-0322",
"CSAFPID-0323",
"CSAFPID-0324",
"CSAFPID-0325",
"CSAFPID-0326",
"CSAFPID-0327",
"CSAFPID-0328",
"CSAFPID-0329",
"CSAFPID-0330",
"CSAFPID-0331",
"CSAFPID-0332",
"CSAFPID-0333",
"CSAFPID-0334",
"CSAFPID-0335",
"CSAFPID-0336",
"CSAFPID-0337",
"CSAFPID-0338",
"CSAFPID-0339",
"CSAFPID-0340",
"CSAFPID-0341",
"CSAFPID-0342",
"CSAFPID-0343",
"CSAFPID-0344",
"CSAFPID-0345",
"CSAFPID-0346",
"CSAFPID-0347",
"CSAFPID-0348",
"CSAFPID-0349",
"CSAFPID-0350",
"CSAFPID-0351",
"CSAFPID-0352",
"CSAFPID-0353",
"CSAFPID-0354",
"CSAFPID-0355",
"CSAFPID-0356",
"CSAFPID-0357",
"CSAFPID-0358",
"CSAFPID-0359",
"CSAFPID-0360",
"CSAFPID-0361",
"CSAFPID-0362",
"CSAFPID-0363",
"CSAFPID-0364",
"CSAFPID-0365",
"CSAFPID-0366",
"CSAFPID-0367",
"CSAFPID-0368",
"CSAFPID-0369",
"CSAFPID-0370",
"CSAFPID-0371",
"CSAFPID-0372",
"CSAFPID-0373",
"CSAFPID-0374",
"CSAFPID-0375",
"CSAFPID-0376",
"CSAFPID-0377",
"CSAFPID-0378",
"CSAFPID-0379",
"CSAFPID-0380",
"CSAFPID-0381",
"CSAFPID-0382",
"CSAFPID-0383",
"CSAFPID-0384",
"CSAFPID-0385",
"CSAFPID-0386",
"CSAFPID-0387",
"CSAFPID-0388",
"CSAFPID-0389",
"CSAFPID-0390",
"CSAFPID-0391",
"CSAFPID-0392",
"CSAFPID-0393",
"CSAFPID-0394",
"CSAFPID-0395",
"CSAFPID-0396",
"CSAFPID-0397",
"CSAFPID-0398",
"CSAFPID-0399",
"CSAFPID-0400",
"CSAFPID-0401",
"CSAFPID-0402",
"CSAFPID-0403",
"CSAFPID-0404",
"CSAFPID-0405",
"CSAFPID-0406",
"CSAFPID-0407",
"CSAFPID-0408",
"CSAFPID-0409",
"CSAFPID-0410",
"CSAFPID-0411",
"CSAFPID-0412",
"CSAFPID-0413",
"CSAFPID-0414",
"CSAFPID-0415",
"CSAFPID-0416",
"CSAFPID-0417",
"CSAFPID-0418",
"CSAFPID-0419",
"CSAFPID-0420",
"CSAFPID-0421",
"CSAFPID-0422",
"CSAFPID-0423",
"CSAFPID-0424",
"CSAFPID-0425",
"CSAFPID-0426",
"CSAFPID-0427",
"CSAFPID-0428",
"CSAFPID-0429",
"CSAFPID-0430",
"CSAFPID-0431",
"CSAFPID-0432",
"CSAFPID-0433",
"CSAFPID-0434",
"CSAFPID-0435",
"CSAFPID-0436",
"CSAFPID-0437",
"CSAFPID-0438",
"CSAFPID-0439",
"CSAFPID-0440",
"CSAFPID-0441",
"CSAFPID-0442",
"CSAFPID-0443",
"CSAFPID-0444",
"CSAFPID-0445",
"CSAFPID-0446",
"CSAFPID-0447",
"CSAFPID-0448",
"CSAFPID-0449",
"CSAFPID-0450",
"CSAFPID-0451",
"CSAFPID-0452",
"CSAFPID-0453",
"CSAFPID-0454",
"CSAFPID-0455",
"CSAFPID-0456",
"CSAFPID-0457",
"CSAFPID-0458",
"CSAFPID-0459",
"CSAFPID-0460",
"CSAFPID-0461",
"CSAFPID-0462",
"CSAFPID-0463",
"CSAFPID-0464",
"CSAFPID-0465",
"CSAFPID-0466",
"CSAFPID-0467",
"CSAFPID-0468",
"CSAFPID-0469",
"CSAFPID-0470",
"CSAFPID-0471",
"CSAFPID-0472",
"CSAFPID-0473",
"CSAFPID-0474",
"CSAFPID-0475",
"CSAFPID-0476",
"CSAFPID-0477",
"CSAFPID-0478",
"CSAFPID-0479",
"CSAFPID-0480",
"CSAFPID-0481",
"CSAFPID-0482",
"CSAFPID-0483",
"CSAFPID-0484",
"CSAFPID-0485",
"CSAFPID-0486",
"CSAFPID-0487",
"CSAFPID-0488",
"CSAFPID-0489",
"CSAFPID-0490",
"CSAFPID-0491",
"CSAFPID-0492",
"CSAFPID-0493",
"CSAFPID-0494",
"CSAFPID-0495",
"CSAFPID-0496",
"CSAFPID-0497"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185",
"CSAFPID-0186",
"CSAFPID-0187",
"CSAFPID-0188",
"CSAFPID-0189",
"CSAFPID-0190",
"CSAFPID-0191",
"CSAFPID-0192",
"CSAFPID-0193",
"CSAFPID-0194",
"CSAFPID-0195",
"CSAFPID-0196",
"CSAFPID-0197",
"CSAFPID-0198",
"CSAFPID-0199",
"CSAFPID-0200",
"CSAFPID-0201",
"CSAFPID-0202",
"CSAFPID-0203",
"CSAFPID-0204",
"CSAFPID-0205",
"CSAFPID-0206",
"CSAFPID-0207",
"CSAFPID-0208",
"CSAFPID-0209",
"CSAFPID-0210",
"CSAFPID-0211",
"CSAFPID-0212",
"CSAFPID-0213",
"CSAFPID-0214",
"CSAFPID-0215",
"CSAFPID-0216",
"CSAFPID-0217",
"CSAFPID-0218",
"CSAFPID-0219",
"CSAFPID-0220",
"CSAFPID-0221",
"CSAFPID-0222",
"CSAFPID-0223",
"CSAFPID-0224",
"CSAFPID-0225",
"CSAFPID-0226",
"CSAFPID-0227",
"CSAFPID-0228",
"CSAFPID-0229",
"CSAFPID-0230",
"CSAFPID-0231",
"CSAFPID-0232",
"CSAFPID-0233",
"CSAFPID-0234",
"CSAFPID-0235",
"CSAFPID-0236",
"CSAFPID-0237",
"CSAFPID-0238",
"CSAFPID-0239",
"CSAFPID-0240",
"CSAFPID-0241",
"CSAFPID-0242",
"CSAFPID-0243",
"CSAFPID-0244",
"CSAFPID-0245",
"CSAFPID-0246",
"CSAFPID-0247",
"CSAFPID-0248",
"CSAFPID-0249",
"CSAFPID-0250",
"CSAFPID-0251",
"CSAFPID-0252",
"CSAFPID-0253",
"CSAFPID-0254",
"CSAFPID-0255",
"CSAFPID-0256",
"CSAFPID-0257",
"CSAFPID-0258",
"CSAFPID-0259",
"CSAFPID-0260",
"CSAFPID-0261",
"CSAFPID-0262",
"CSAFPID-0263",
"CSAFPID-0264",
"CSAFPID-0265",
"CSAFPID-0266",
"CSAFPID-0267",
"CSAFPID-0268",
"CSAFPID-0269",
"CSAFPID-0270",
"CSAFPID-0271",
"CSAFPID-0272",
"CSAFPID-0273",
"CSAFPID-0274",
"CSAFPID-0275",
"CSAFPID-0276",
"CSAFPID-0277",
"CSAFPID-0278",
"CSAFPID-0279",
"CSAFPID-0280",
"CSAFPID-0281",
"CSAFPID-0282",
"CSAFPID-0283",
"CSAFPID-0284",
"CSAFPID-0285",
"CSAFPID-0286",
"CSAFPID-0287",
"CSAFPID-0288",
"CSAFPID-0289",
"CSAFPID-0290",
"CSAFPID-0291",
"CSAFPID-0292",
"CSAFPID-0293",
"CSAFPID-0294",
"CSAFPID-0295",
"CSAFPID-0296",
"CSAFPID-0297",
"CSAFPID-0298",
"CSAFPID-0299",
"CSAFPID-0300",
"CSAFPID-0301",
"CSAFPID-0302",
"CSAFPID-0303",
"CSAFPID-0304",
"CSAFPID-0305",
"CSAFPID-0306",
"CSAFPID-0307",
"CSAFPID-0308",
"CSAFPID-0309",
"CSAFPID-0310",
"CSAFPID-0311",
"CSAFPID-0312",
"CSAFPID-0313",
"CSAFPID-0314",
"CSAFPID-0315",
"CSAFPID-0316",
"CSAFPID-0317",
"CSAFPID-0318",
"CSAFPID-0319",
"CSAFPID-0320",
"CSAFPID-0321",
"CSAFPID-0322",
"CSAFPID-0323",
"CSAFPID-0324",
"CSAFPID-0325",
"CSAFPID-0326",
"CSAFPID-0327",
"CSAFPID-0328",
"CSAFPID-0329",
"CSAFPID-0330",
"CSAFPID-0331",
"CSAFPID-0332",
"CSAFPID-0333",
"CSAFPID-0334",
"CSAFPID-0335",
"CSAFPID-0336",
"CSAFPID-0337",
"CSAFPID-0338",
"CSAFPID-0339",
"CSAFPID-0340",
"CSAFPID-0341",
"CSAFPID-0342",
"CSAFPID-0343",
"CSAFPID-0344",
"CSAFPID-0345",
"CSAFPID-0346",
"CSAFPID-0347",
"CSAFPID-0348",
"CSAFPID-0349",
"CSAFPID-0350",
"CSAFPID-0351",
"CSAFPID-0352",
"CSAFPID-0353",
"CSAFPID-0354",
"CSAFPID-0355",
"CSAFPID-0356",
"CSAFPID-0357",
"CSAFPID-0358",
"CSAFPID-0359",
"CSAFPID-0360",
"CSAFPID-0361",
"CSAFPID-0362",
"CSAFPID-0363",
"CSAFPID-0364",
"CSAFPID-0365",
"CSAFPID-0366",
"CSAFPID-0367",
"CSAFPID-0368",
"CSAFPID-0369",
"CSAFPID-0370",
"CSAFPID-0371",
"CSAFPID-0372",
"CSAFPID-0373",
"CSAFPID-0374",
"CSAFPID-0375",
"CSAFPID-0376",
"CSAFPID-0377",
"CSAFPID-0378",
"CSAFPID-0379",
"CSAFPID-0380",
"CSAFPID-0381",
"CSAFPID-0382",
"CSAFPID-0383",
"CSAFPID-0384",
"CSAFPID-0385",
"CSAFPID-0386",
"CSAFPID-0387",
"CSAFPID-0388",
"CSAFPID-0389",
"CSAFPID-0390",
"CSAFPID-0391",
"CSAFPID-0392",
"CSAFPID-0393",
"CSAFPID-0394",
"CSAFPID-0395",
"CSAFPID-0396",
"CSAFPID-0397",
"CSAFPID-0398",
"CSAFPID-0399",
"CSAFPID-0400",
"CSAFPID-0401",
"CSAFPID-0402",
"CSAFPID-0403",
"CSAFPID-0404",
"CSAFPID-0405",
"CSAFPID-0406",
"CSAFPID-0407",
"CSAFPID-0408",
"CSAFPID-0409",
"CSAFPID-0410",
"CSAFPID-0411",
"CSAFPID-0412",
"CSAFPID-0413",
"CSAFPID-0414",
"CSAFPID-0415",
"CSAFPID-0416",
"CSAFPID-0417",
"CSAFPID-0418",
"CSAFPID-0419",
"CSAFPID-0420",
"CSAFPID-0421",
"CSAFPID-0422",
"CSAFPID-0423",
"CSAFPID-0424",
"CSAFPID-0425",
"CSAFPID-0426",
"CSAFPID-0427",
"CSAFPID-0428",
"CSAFPID-0429",
"CSAFPID-0430",
"CSAFPID-0431",
"CSAFPID-0432",
"CSAFPID-0433",
"CSAFPID-0434",
"CSAFPID-0435",
"CSAFPID-0436",
"CSAFPID-0437",
"CSAFPID-0438",
"CSAFPID-0439",
"CSAFPID-0440",
"CSAFPID-0441",
"CSAFPID-0442",
"CSAFPID-0443",
"CSAFPID-0444",
"CSAFPID-0445",
"CSAFPID-0446",
"CSAFPID-0447",
"CSAFPID-0448",
"CSAFPID-0449",
"CSAFPID-0450",
"CSAFPID-0451",
"CSAFPID-0452",
"CSAFPID-0453",
"CSAFPID-0454",
"CSAFPID-0455",
"CSAFPID-0456",
"CSAFPID-0457",
"CSAFPID-0458",
"CSAFPID-0459",
"CSAFPID-0460",
"CSAFPID-0461",
"CSAFPID-0462",
"CSAFPID-0463",
"CSAFPID-0464",
"CSAFPID-0465",
"CSAFPID-0466",
"CSAFPID-0467",
"CSAFPID-0468",
"CSAFPID-0469",
"CSAFPID-0470",
"CSAFPID-0471",
"CSAFPID-0472",
"CSAFPID-0473",
"CSAFPID-0474",
"CSAFPID-0475",
"CSAFPID-0476",
"CSAFPID-0477",
"CSAFPID-0478",
"CSAFPID-0479",
"CSAFPID-0480",
"CSAFPID-0481",
"CSAFPID-0482",
"CSAFPID-0483",
"CSAFPID-0484",
"CSAFPID-0485",
"CSAFPID-0486",
"CSAFPID-0487",
"CSAFPID-0488",
"CSAFPID-0489",
"CSAFPID-0490",
"CSAFPID-0491",
"CSAFPID-0492",
"CSAFPID-0493",
"CSAFPID-0494",
"CSAFPID-0495",
"CSAFPID-0496",
"CSAFPID-0497"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185",
"CSAFPID-0186",
"CSAFPID-0187"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0366",
"CSAFPID-0367",
"CSAFPID-0368",
"CSAFPID-0369",
"CSAFPID-0370",
"CSAFPID-0371",
"CSAFPID-0455",
"CSAFPID-0456",
"CSAFPID-0457",
"CSAFPID-0458",
"CSAFPID-0459",
"CSAFPID-0460",
"CSAFPID-0468",
"CSAFPID-0469",
"CSAFPID-0470",
"CSAFPID-0471",
"CSAFPID-0472",
"CSAFPID-0473",
"CSAFPID-0474",
"CSAFPID-0475",
"CSAFPID-0476",
"CSAFPID-0477",
"CSAFPID-0478",
"CSAFPID-0479",
"CSAFPID-0480",
"CSAFPID-0481"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.0 SP2 Update 4 or later version",
"product_ids": [
"CSAFPID-0492"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.3 or later version",
"product_ids": [
"CSAFPID-0350",
"CSAFPID-0351",
"CSAFPID-0352",
"CSAFPID-0353",
"CSAFPID-0354",
"CSAFPID-0355",
"CSAFPID-0356",
"CSAFPID-0393",
"CSAFPID-0394",
"CSAFPID-0395",
"CSAFPID-0396",
"CSAFPID-0397",
"CSAFPID-0398",
"CSAFPID-0439",
"CSAFPID-0440",
"CSAFPID-0441",
"CSAFPID-0442",
"CSAFPID-0449",
"CSAFPID-0450",
"CSAFPID-0451",
"CSAFPID-0452",
"CSAFPID-0453",
"CSAFPID-0454",
"CSAFPID-0461",
"CSAFPID-0462",
"CSAFPID-0463",
"CSAFPID-0464",
"CSAFPID-0465",
"CSAFPID-0466",
"CSAFPID-0467"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977441/"
},
{
"category": "vendor_fix",
"details": "Update to V2.17.0 or later version",
"product_ids": [
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109997648/"
},
{
"category": "vendor_fix",
"details": "Update to V3.0.0 or later version",
"product_ids": [
"CSAFPID-0237",
"CSAFPID-0238",
"CSAFPID-0239",
"CSAFPID-0240",
"CSAFPID-0241",
"CSAFPID-0242",
"CSAFPID-0243",
"CSAFPID-0244",
"CSAFPID-0245",
"CSAFPID-0246",
"CSAFPID-0247",
"CSAFPID-0248",
"CSAFPID-0249",
"CSAFPID-0250",
"CSAFPID-0251",
"CSAFPID-0252",
"CSAFPID-0253",
"CSAFPID-0254",
"CSAFPID-0255"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977720/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2 or later version",
"product_ids": [
"CSAFPID-0149",
"CSAFPID-0357",
"CSAFPID-0358",
"CSAFPID-0359",
"CSAFPID-0482",
"CSAFPID-0483",
"CSAFPID-0484",
"CSAFPID-0485",
"CSAFPID-0486",
"CSAFPID-0487",
"CSAFPID-0488",
"CSAFPID-0489",
"CSAFPID-0490",
"CSAFPID-0491"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109988839/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2 or later version",
"product_ids": [
"CSAFPID-0360"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109988839/"
},
{
"category": "vendor_fix",
"details": "Update to V4.1.9 or later version",
"product_ids": [
"CSAFPID-0256",
"CSAFPID-0257",
"CSAFPID-0258",
"CSAFPID-0259",
"CSAFPID-0260",
"CSAFPID-0261",
"CSAFPID-0262",
"CSAFPID-0263",
"CSAFPID-0264",
"CSAFPID-0265",
"CSAFPID-0266",
"CSAFPID-0267",
"CSAFPID-0268",
"CSAFPID-0269",
"CSAFPID-0270",
"CSAFPID-0271",
"CSAFPID-0272",
"CSAFPID-0273",
"CSAFPID-0274",
"CSAFPID-0275",
"CSAFPID-0276",
"CSAFPID-0277",
"CSAFPID-0278",
"CSAFPID-0279",
"CSAFPID-0280",
"CSAFPID-0281",
"CSAFPID-0282",
"CSAFPID-0283",
"CSAFPID-0284",
"CSAFPID-0285",
"CSAFPID-0286",
"CSAFPID-0287",
"CSAFPID-0288",
"CSAFPID-0289",
"CSAFPID-0290",
"CSAFPID-0291",
"CSAFPID-0292",
"CSAFPID-0293",
"CSAFPID-0294",
"CSAFPID-0295",
"CSAFPID-0296",
"CSAFPID-0297",
"CSAFPID-0298",
"CSAFPID-0399",
"CSAFPID-0400",
"CSAFPID-0401",
"CSAFPID-0402",
"CSAFPID-0403",
"CSAFPID-0404",
"CSAFPID-0405",
"CSAFPID-0406",
"CSAFPID-0407",
"CSAFPID-0408",
"CSAFPID-0409",
"CSAFPID-0410",
"CSAFPID-0411",
"CSAFPID-0412",
"CSAFPID-0413",
"CSAFPID-0414",
"CSAFPID-0415",
"CSAFPID-0416",
"CSAFPID-0417",
"CSAFPID-0418",
"CSAFPID-0419",
"CSAFPID-0420",
"CSAFPID-0421",
"CSAFPID-0422",
"CSAFPID-0423",
"CSAFPID-0424",
"CSAFPID-0425",
"CSAFPID-0426",
"CSAFPID-0427",
"CSAFPID-0428",
"CSAFPID-0429",
"CSAFPID-0430",
"CSAFPID-0431",
"CSAFPID-0432",
"CSAFPID-0433",
"CSAFPID-0434",
"CSAFPID-0493"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109982245/"
},
{
"category": "vendor_fix",
"details": "Update to V4.3.11 or later version",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0018",
"CSAFPID-0020",
"CSAFPID-0022",
"CSAFPID-0035",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0041",
"CSAFPID-0043",
"CSAFPID-0045",
"CSAFPID-0047",
"CSAFPID-0055",
"CSAFPID-0057",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0062",
"CSAFPID-0065",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0076",
"CSAFPID-0078",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0105",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0111",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0119",
"CSAFPID-0121",
"CSAFPID-0125",
"CSAFPID-0129",
"CSAFPID-0133",
"CSAFPID-0141"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977251/"
},
{
"category": "vendor_fix",
"details": "Update to V4.3.11 or later version",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013",
"CSAFPID-0015",
"CSAFPID-0019",
"CSAFPID-0036",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0042",
"CSAFPID-0044",
"CSAFPID-0046",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0061",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0066",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0077",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0098",
"CSAFPID-0101",
"CSAFPID-0104",
"CSAFPID-0106",
"CSAFPID-0110",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0120",
"CSAFPID-0123",
"CSAFPID-0127",
"CSAFPID-0131",
"CSAFPID-0135",
"CSAFPID-0143"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977251/"
},
{
"category": "vendor_fix",
"details": "Update to V4.6 or later version",
"product_ids": [
"CSAFPID-0299",
"CSAFPID-0300",
"CSAFPID-0301",
"CSAFPID-0302",
"CSAFPID-0303",
"CSAFPID-0304",
"CSAFPID-0305",
"CSAFPID-0306",
"CSAFPID-0307",
"CSAFPID-0308",
"CSAFPID-0309",
"CSAFPID-0310",
"CSAFPID-0311",
"CSAFPID-0312",
"CSAFPID-0313",
"CSAFPID-0314",
"CSAFPID-0315",
"CSAFPID-0316",
"CSAFPID-0317",
"CSAFPID-0318",
"CSAFPID-0319",
"CSAFPID-0320",
"CSAFPID-0321",
"CSAFPID-0322",
"CSAFPID-0323",
"CSAFPID-0324",
"CSAFPID-0325",
"CSAFPID-0326",
"CSAFPID-0327",
"CSAFPID-0328",
"CSAFPID-0329",
"CSAFPID-0330",
"CSAFPID-0331",
"CSAFPID-0332",
"CSAFPID-0333",
"CSAFPID-0334",
"CSAFPID-0335",
"CSAFPID-0336",
"CSAFPID-0337",
"CSAFPID-0338",
"CSAFPID-0339",
"CSAFPID-0340",
"CSAFPID-0341",
"CSAFPID-0342",
"CSAFPID-0343",
"CSAFPID-0344",
"CSAFPID-0345",
"CSAFPID-0346",
"CSAFPID-0347",
"CSAFPID-0348",
"CSAFPID-0349",
"CSAFPID-0361",
"CSAFPID-0362",
"CSAFPID-0363",
"CSAFPID-0364",
"CSAFPID-0365",
"CSAFPID-0372",
"CSAFPID-0373",
"CSAFPID-0374",
"CSAFPID-0375",
"CSAFPID-0376",
"CSAFPID-0377",
"CSAFPID-0378",
"CSAFPID-0379",
"CSAFPID-0380",
"CSAFPID-0381",
"CSAFPID-0382",
"CSAFPID-0383",
"CSAFPID-0384",
"CSAFPID-0385",
"CSAFPID-0386",
"CSAFPID-0387",
"CSAFPID-0388",
"CSAFPID-0389",
"CSAFPID-0390",
"CSAFPID-0391",
"CSAFPID-0392",
"CSAFPID-0435",
"CSAFPID-0436",
"CSAFPID-0437",
"CSAFPID-0438",
"CSAFPID-0443",
"CSAFPID-0444",
"CSAFPID-0445",
"CSAFPID-0446",
"CSAFPID-0447",
"CSAFPID-0448",
"CSAFPID-0494",
"CSAFPID-0495",
"CSAFPID-0496",
"CSAFPID-0497"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977185/"
},
{
"category": "vendor_fix",
"details": "Update to V5.10.0 or later version",
"product_ids": [
"CSAFPID-0021",
"CSAFPID-0056",
"CSAFPID-0058",
"CSAFPID-0069",
"CSAFPID-0072",
"CSAFPID-0109",
"CSAFPID-0115",
"CSAFPID-0122",
"CSAFPID-0126",
"CSAFPID-0130",
"CSAFPID-0134",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0142",
"CSAFPID-0145",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0150",
"CSAFPID-0151"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109989952/"
},
{
"category": "vendor_fix",
"details": "Update to V5.10.0 or later version",
"product_ids": [
"CSAFPID-0023",
"CSAFPID-0050",
"CSAFPID-0054",
"CSAFPID-0075",
"CSAFPID-0090",
"CSAFPID-0112",
"CSAFPID-0118",
"CSAFPID-0124",
"CSAFPID-0128",
"CSAFPID-0132",
"CSAFPID-0136",
"CSAFPID-0144",
"CSAFPID-0146"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109989952/"
},
{
"category": "vendor_fix",
"details": "Update to V5.6 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109976555/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0188",
"CSAFPID-0189",
"CSAFPID-0190",
"CSAFPID-0191",
"CSAFPID-0192",
"CSAFPID-0193",
"CSAFPID-0194",
"CSAFPID-0195",
"CSAFPID-0196",
"CSAFPID-0197",
"CSAFPID-0198",
"CSAFPID-0199",
"CSAFPID-0200",
"CSAFPID-0201",
"CSAFPID-0202",
"CSAFPID-0203",
"CSAFPID-0204",
"CSAFPID-0205",
"CSAFPID-0206",
"CSAFPID-0207",
"CSAFPID-0208",
"CSAFPID-0209",
"CSAFPID-0210",
"CSAFPID-0211",
"CSAFPID-0212",
"CSAFPID-0213",
"CSAFPID-0214",
"CSAFPID-0215",
"CSAFPID-0216",
"CSAFPID-0217",
"CSAFPID-0218",
"CSAFPID-0219",
"CSAFPID-0220",
"CSAFPID-0221",
"CSAFPID-0222",
"CSAFPID-0223",
"CSAFPID-0224",
"CSAFPID-0225",
"CSAFPID-0226",
"CSAFPID-0227",
"CSAFPID-0228",
"CSAFPID-0229",
"CSAFPID-0230",
"CSAFPID-0231",
"CSAFPID-0232",
"CSAFPID-0233",
"CSAFPID-0234",
"CSAFPID-0235",
"CSAFPID-0236"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V8.2 or later version",
"product_ids": [
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109976047/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185",
"CSAFPID-0186",
"CSAFPID-0187",
"CSAFPID-0188",
"CSAFPID-0189",
"CSAFPID-0190",
"CSAFPID-0191",
"CSAFPID-0192",
"CSAFPID-0193",
"CSAFPID-0194",
"CSAFPID-0195",
"CSAFPID-0196",
"CSAFPID-0197",
"CSAFPID-0198",
"CSAFPID-0199",
"CSAFPID-0200",
"CSAFPID-0201",
"CSAFPID-0202",
"CSAFPID-0203",
"CSAFPID-0204",
"CSAFPID-0205",
"CSAFPID-0206",
"CSAFPID-0207",
"CSAFPID-0208",
"CSAFPID-0209",
"CSAFPID-0210",
"CSAFPID-0211",
"CSAFPID-0212",
"CSAFPID-0213",
"CSAFPID-0214",
"CSAFPID-0215",
"CSAFPID-0216",
"CSAFPID-0217",
"CSAFPID-0218",
"CSAFPID-0219",
"CSAFPID-0220",
"CSAFPID-0221",
"CSAFPID-0222",
"CSAFPID-0223",
"CSAFPID-0224",
"CSAFPID-0225",
"CSAFPID-0226",
"CSAFPID-0227",
"CSAFPID-0228",
"CSAFPID-0229",
"CSAFPID-0230",
"CSAFPID-0231",
"CSAFPID-0232",
"CSAFPID-0233",
"CSAFPID-0234",
"CSAFPID-0235",
"CSAFPID-0236",
"CSAFPID-0237",
"CSAFPID-0238",
"CSAFPID-0239",
"CSAFPID-0240",
"CSAFPID-0241",
"CSAFPID-0242",
"CSAFPID-0243",
"CSAFPID-0244",
"CSAFPID-0245",
"CSAFPID-0246",
"CSAFPID-0247",
"CSAFPID-0248",
"CSAFPID-0249",
"CSAFPID-0250",
"CSAFPID-0251",
"CSAFPID-0252",
"CSAFPID-0253",
"CSAFPID-0254",
"CSAFPID-0255",
"CSAFPID-0256",
"CSAFPID-0257",
"CSAFPID-0258",
"CSAFPID-0259",
"CSAFPID-0260",
"CSAFPID-0261",
"CSAFPID-0262",
"CSAFPID-0263",
"CSAFPID-0264",
"CSAFPID-0265",
"CSAFPID-0266",
"CSAFPID-0267",
"CSAFPID-0268",
"CSAFPID-0269",
"CSAFPID-0270",
"CSAFPID-0271",
"CSAFPID-0272",
"CSAFPID-0273",
"CSAFPID-0274",
"CSAFPID-0275",
"CSAFPID-0276",
"CSAFPID-0277",
"CSAFPID-0278",
"CSAFPID-0279",
"CSAFPID-0280",
"CSAFPID-0281",
"CSAFPID-0282",
"CSAFPID-0283",
"CSAFPID-0284",
"CSAFPID-0285",
"CSAFPID-0286",
"CSAFPID-0287",
"CSAFPID-0288",
"CSAFPID-0289",
"CSAFPID-0290",
"CSAFPID-0291",
"CSAFPID-0292",
"CSAFPID-0293",
"CSAFPID-0294",
"CSAFPID-0295",
"CSAFPID-0296",
"CSAFPID-0297",
"CSAFPID-0298",
"CSAFPID-0299",
"CSAFPID-0300",
"CSAFPID-0301",
"CSAFPID-0302",
"CSAFPID-0303",
"CSAFPID-0304",
"CSAFPID-0305",
"CSAFPID-0306",
"CSAFPID-0307",
"CSAFPID-0308",
"CSAFPID-0309",
"CSAFPID-0310",
"CSAFPID-0311",
"CSAFPID-0312",
"CSAFPID-0313",
"CSAFPID-0314",
"CSAFPID-0315",
"CSAFPID-0316",
"CSAFPID-0317",
"CSAFPID-0318",
"CSAFPID-0319",
"CSAFPID-0320",
"CSAFPID-0321",
"CSAFPID-0322",
"CSAFPID-0323",
"CSAFPID-0324",
"CSAFPID-0325",
"CSAFPID-0326",
"CSAFPID-0327",
"CSAFPID-0328",
"CSAFPID-0329",
"CSAFPID-0330",
"CSAFPID-0331",
"CSAFPID-0332",
"CSAFPID-0333",
"CSAFPID-0334",
"CSAFPID-0335",
"CSAFPID-0336",
"CSAFPID-0337",
"CSAFPID-0338",
"CSAFPID-0339",
"CSAFPID-0340",
"CSAFPID-0341",
"CSAFPID-0342",
"CSAFPID-0343",
"CSAFPID-0344",
"CSAFPID-0345",
"CSAFPID-0346",
"CSAFPID-0347",
"CSAFPID-0348",
"CSAFPID-0349",
"CSAFPID-0350",
"CSAFPID-0351",
"CSAFPID-0352",
"CSAFPID-0353",
"CSAFPID-0354",
"CSAFPID-0355",
"CSAFPID-0356",
"CSAFPID-0357",
"CSAFPID-0358",
"CSAFPID-0359",
"CSAFPID-0360",
"CSAFPID-0361",
"CSAFPID-0362",
"CSAFPID-0363",
"CSAFPID-0364",
"CSAFPID-0365",
"CSAFPID-0366",
"CSAFPID-0367",
"CSAFPID-0368",
"CSAFPID-0369",
"CSAFPID-0370",
"CSAFPID-0371",
"CSAFPID-0372",
"CSAFPID-0373",
"CSAFPID-0374",
"CSAFPID-0375",
"CSAFPID-0376",
"CSAFPID-0377",
"CSAFPID-0378",
"CSAFPID-0379",
"CSAFPID-0380",
"CSAFPID-0381",
"CSAFPID-0382",
"CSAFPID-0383",
"CSAFPID-0384",
"CSAFPID-0385",
"CSAFPID-0386",
"CSAFPID-0387",
"CSAFPID-0388",
"CSAFPID-0389",
"CSAFPID-0390",
"CSAFPID-0391",
"CSAFPID-0392",
"CSAFPID-0393",
"CSAFPID-0394",
"CSAFPID-0395",
"CSAFPID-0396",
"CSAFPID-0397",
"CSAFPID-0398",
"CSAFPID-0399",
"CSAFPID-0400",
"CSAFPID-0401",
"CSAFPID-0402",
"CSAFPID-0403",
"CSAFPID-0404",
"CSAFPID-0405",
"CSAFPID-0406",
"CSAFPID-0407",
"CSAFPID-0408",
"CSAFPID-0409",
"CSAFPID-0410",
"CSAFPID-0411",
"CSAFPID-0412",
"CSAFPID-0413",
"CSAFPID-0414",
"CSAFPID-0415",
"CSAFPID-0416",
"CSAFPID-0417",
"CSAFPID-0418",
"CSAFPID-0419",
"CSAFPID-0420",
"CSAFPID-0421",
"CSAFPID-0422",
"CSAFPID-0423",
"CSAFPID-0424",
"CSAFPID-0425",
"CSAFPID-0426",
"CSAFPID-0427",
"CSAFPID-0428",
"CSAFPID-0429",
"CSAFPID-0430",
"CSAFPID-0431",
"CSAFPID-0432",
"CSAFPID-0433",
"CSAFPID-0434",
"CSAFPID-0435",
"CSAFPID-0436",
"CSAFPID-0437",
"CSAFPID-0438",
"CSAFPID-0439",
"CSAFPID-0440",
"CSAFPID-0441",
"CSAFPID-0442",
"CSAFPID-0443",
"CSAFPID-0444",
"CSAFPID-0445",
"CSAFPID-0446",
"CSAFPID-0447",
"CSAFPID-0448",
"CSAFPID-0449",
"CSAFPID-0450",
"CSAFPID-0451",
"CSAFPID-0452",
"CSAFPID-0453",
"CSAFPID-0454",
"CSAFPID-0455",
"CSAFPID-0456",
"CSAFPID-0457",
"CSAFPID-0458",
"CSAFPID-0459",
"CSAFPID-0460",
"CSAFPID-0461",
"CSAFPID-0462",
"CSAFPID-0463",
"CSAFPID-0464",
"CSAFPID-0465",
"CSAFPID-0466",
"CSAFPID-0467",
"CSAFPID-0468",
"CSAFPID-0469",
"CSAFPID-0470",
"CSAFPID-0471",
"CSAFPID-0472",
"CSAFPID-0473",
"CSAFPID-0474",
"CSAFPID-0475",
"CSAFPID-0476",
"CSAFPID-0477",
"CSAFPID-0478",
"CSAFPID-0479",
"CSAFPID-0480",
"CSAFPID-0481",
"CSAFPID-0482",
"CSAFPID-0483",
"CSAFPID-0484",
"CSAFPID-0485",
"CSAFPID-0486",
"CSAFPID-0487",
"CSAFPID-0488",
"CSAFPID-0489",
"CSAFPID-0490",
"CSAFPID-0491",
"CSAFPID-0492",
"CSAFPID-0493",
"CSAFPID-0494",
"CSAFPID-0495",
"CSAFPID-0496",
"CSAFPID-0497"
]
}
],
"title": "CVE-2024-3596"
}
]
}
ICSA-24-193-11
Vulnerability from csaf_cisa - Published: 2024-07-09 00:00 - Updated: 2026-01-14 22:00Summary
Siemens RUGGEDCOM APE 1808
Notes
Summary: Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities.
Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications.
[1] https://security.paloaltonetworks.com/
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Siemens ProductCERT SSA-364175 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
5.9 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
9.0 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
CWE-20
- Improper Input Validation
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
CWE-79
- Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
CWE-787
- Out-of-bounds Write
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
CWE-20
- Improper Input Validation
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
5.9 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
9.1 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Mitigation
Vendor Fix
|
7.5 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Mitigation
Mitigation
Vendor Fix
|
References
10 references
Acknowledgments
Siemens ProductCERT
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reported these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities.\n\nSiemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks\u0027 upstream security notifications.\n\n[1] https://security.paloaltonetworks.com/",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-364175 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-364175: Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.4-h1 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-364175.json"
},
{
"category": "self",
"summary": "SSA-364175: Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.4-h1 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-193-11 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-11.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-193-11 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-11"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens RUGGEDCOM APE 1808",
"tracking": {
"current_release_date": "2026-01-14T22:00:09.701376Z",
"generator": {
"date": "2026-01-14T22:00:09.700371Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-24-193-11",
"initial_release_date": "2024-07-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-07-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-08-13T00:00:00.000000Z",
"legacy_version": "Revision 1",
"number": "2",
"summary": "Added newly published CVE-2024-5913 and CVE-2024-3596"
},
{
"date": "2024-10-08T00:00:00.000000Z",
"legacy_version": "Revision 2",
"number": "3",
"summary": "Added CVE-2023-48795, CVE-2024-3596, CVE-2024-5913 and fix version information for Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 devices"
},
{
"date": "2024-11-12T00:00:00.000000Z",
"legacy_version": "Revision 3",
"number": "4",
"summary": "Added newly published CVE-2024-9468 and CVE-2024-9471. Added CVSSv4.0 vector to CVE-2024-5913"
},
{
"date": "2024-12-10T00:00:00.000000Z",
"legacy_version": "Revision 4",
"number": "5",
"summary": "Added newly published CVE-2024-5920"
},
{
"date": "2025-04-08T00:00:00.000000Z",
"legacy_version": "Revision 5",
"number": "6",
"summary": "Added newly published CVE-2025-0114"
},
{
"date": "2025-07-08T00:00:00.000000Z",
"legacy_version": "Revision 6",
"number": "7",
"summary": "Added newly published CVE-2025-4231"
},
{
"date": "2026-01-13T00:00:00.000000Z",
"legacy_version": "Revision 7",
"number": "8",
"summary": "Added newly published CVE-2025-4619"
},
{
"date": "2026-01-14T22:00:09.701376Z",
"legacy_version": "CISA Republication",
"number": "9",
"summary": "Initial Republication of Siemens ProductCERT SSA-364175 advisory"
}
],
"status": "final",
"version": "9"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0002"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM APE1808"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-48795",
"cwe": {
"id": "CWE-222",
"name": "Truncation of Security-relevant Information"
},
"notes": [
{
"category": "summary",
"text": "The SSH transport protocol with certain OpenSSH extensions, found in OpenSSH before 9.6 and other products, allows remote attackers to bypass integrity checks such that some packets are omitted (from the extension negotiation message), and a client and server may consequently end up with a connection for which some security features have been downgraded or disabled, aka a Terrapin attack. This occurs because the SSH Binary Packet Protocol (BPP), implemented by these extensions, mishandles the handshake phase and mishandles use of sequence numbers. For example, there is an effective attack against SSH\u0027s use of ChaCha20-Poly1305 (and CBC with Encrypt-then-MAC). The bypass occurs in chacha20-poly1305@openssh.com and (if CBC is used) the -etm@openssh.com MAC algorithms. This also affects Maverick Synergy Java SSH API before 3.1.0-SNAPSHOT, Dropbear through 2022.83, Ssh before 5.1.1 in Erlang/OTP, PuTTY before 0.80, AsyncSSH before 2.14.2, golang.org/x/crypto before 0.17.0, libssh before 0.10.6, libssh2 through 1.11.0, Thorn Tech SFTP Gateway before 3.4.6, Tera Term before 5.1, Paramiko before 3.4.0, jsch before 0.2.15, SFTPGo before 2.5.6, Netgate pfSense Plus through 23.09.1, Netgate pfSense CE through 2.7.2, HPN-SSH through 18.2.0, ProFTPD before 1.3.8b (and before1.3.9rc2), ORYX CycloneSSH before 2.3.4, NetSarang XShell 7 before Build 0144, CrushFTP before 10.6.0, ConnectBot SSH library before 2.2.22, Apache MINA sshd through 2.11.0, sshj through 0.37.0, TinySSH through 20230101, trilead-ssh2 6401, the net-ssh gem 7.2.0 for Ruby, the mscdex ssh2 module before 1.15.0 for Node.js, the thrussh library before 0.35.1 for Rust, and the Russh crate before 0.40.2 for Rust; and there could be effects on Bitvise SSH through 9.31.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-48795"
},
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "summary",
"text": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify responses Access-Reject or Access-Accept using a chosen-prefix collision attack against MD5 Response Authenticator signature.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-3596"
},
{
"cve": "CVE-2024-5913",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An improper input validation vulnerability in Palo Alto Networks PAN-OS software enables an attacker with the ability to tamper with the physical file system to elevate privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-5913"
},
{
"cve": "CVE-2024-5920",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-write Panorama administrator to push a specially crafted configuration to a PAN-OS node. This enables impersonation of a legitimate PAN-OS administrator who can perform restricted actions on the PAN-OS node after the execution of JavaScript in the legitimate PAN-OS administrator\u0027s browser.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-5920"
},
{
"cve": "CVE-2024-9468",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption vulnerability in Palo Alto Networks PAN-OS software allows an unauthenticated attacker to crash PAN-OS due to a crafted packet through the data plane, resulting in a denial of service (DoS) condition. Repeated attempts to trigger this condition will result in PAN-OS entering maintenance mode.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-9468"
},
{
"cve": "CVE-2024-9471",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A privilege escalation (PE) vulnerability in the XML API of Palo Alto Networks PAN-OS software enables an authenticated PAN-OS administrator with restricted privileges to use a compromised XML API key to perform actions as a higher privileged PAN-OS administrator. For example, an administrator with \"Virtual system administrator (read-only)\" access could use an XML API key of a \"Virtual system administrator\" to perform write operations on the virtual system configuration even though they should be limited to read-only operations.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-9471"
},
{
"cve": "CVE-2025-0114",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "A Denial of Service (DoS) vulnerability in the GlobalProtect feature of Palo Alto Networks PAN-OS software enables an unauthenticated attacker to render the service unavailable by sending a large number of specially crafted packets over a period of time. This issue affects both the GlobalProtect portal and the GlobalProtect gateway.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0003"
]
}
],
"title": "CVE-2025-0114"
},
{
"cve": "CVE-2025-4231",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A command injection vulnerability in Palo Alto Networks PAN-OS\u00ae enables an authenticated administrative user to perform actions as the root user.\r\nThe attacker must have network access to the management web interface and successfully authenticate to exploit this issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Exposure can be reduced by limiting access to the management interface to trusted internal IP addresses as described in Palo Alto Networks\u0027 Security Advisory",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2025-4231"
},
{
"cve": "CVE-2025-4619",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "A denial-of-service (DoS) vulnerability in Palo Alto Networks PAN-OS software enables an unauthenticated attacker to reboot a firewall by sending a specially crafted packet through the dataplane. Repeated attempts to initiate a reboot causes the firewall to enter maintenance mode.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0004"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks\u0027 upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Palo Alto Networks Virtual NGFW V11.1.4-h1. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0004"
]
}
],
"title": "CVE-2025-4619"
}
]
}
ICSA-25-044-06
Vulnerability from csaf_cisa - Published: 2025-02-11 00:00 - Updated: 2026-03-12 06:00Summary
Siemens RUGGEDCOM APE1808
Notes
Summary: Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products.
Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Siemens ProductCERT SSA-770770 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
9.8 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
9.8 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
9.0 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
9.8 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
7.5 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
8.1 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
6.5 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
8.8 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
7.2 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
CWE-201
- Insertion of Sensitive Information Into Sent Data
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
5.3 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
7.5 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
CWE-190
- Integer Overflow or Wraparound
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
7.5 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
4.3 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
7.5 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
5.3 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
9.0 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
7.3 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
CWE-300
- Channel Accessible by Non-Endpoint
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
7.2 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
CWE-304
- Missing Critical Step in Authentication
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
6.5 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
CWE-923
- Improper Restriction of Communication Channel to Intended Endpoints
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
9.8 (Critical)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
CWE-269
- Improper Privilege Management
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
6.5 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
4.8 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
8.2 (High)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Mitigation
Vendor Fix
|
5.9 (Medium)
Affected products
Known affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
vers:all/* |
Vendor Fix
|
References
85 references
Acknowledgments
Siemens ProductCERT
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reported these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products.\n\nSiemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-770770 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-770770: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.7 on RUGGEDCOM APE1808 Devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-770770.json"
},
{
"category": "self",
"summary": "SSA-770770: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.7 on RUGGEDCOM APE1808 Devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-044-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-044-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-044-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-044-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens RUGGEDCOM APE1808",
"tracking": {
"current_release_date": "2026-03-12T06:00:00.000000Z",
"generator": {
"date": "2026-03-11T21:23:50.812872Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-25-044-06",
"initial_release_date": "2025-02-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2025-02-11T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-03-11T00:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "Added newly published upstream vulnerabilities CVE-2024-35279 and CVE-2024-40591"
},
{
"date": "2025-04-08T00:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Added newly published upstream vulnerabilities CVE-2024-48886, CVE-2024-50563, CVE-2024-45324 and CVE-2024-3596"
},
{
"date": "2025-05-13T00:00:00.000000Z",
"legacy_version": "Additional Release 3",
"number": "4",
"summary": "Added newly published upstream vulnerabilities CVE-2024-21762, CVE-2022-42475, CVE-2023-27997, CVE-2024-26013 and CVE-2024-50565. Moved CVE-2024-52963 to SSA-864900"
},
{
"date": "2025-06-10T00:00:00.000000Z",
"legacy_version": "Additional Release 4",
"number": "5",
"summary": "Added newly published upstream vulnerability CVE-2025-22252"
},
{
"date": "2025-07-08T00:00:00.000000Z",
"legacy_version": "Additional Release 5",
"number": "6",
"summary": "Added newly published upstream vulnerabilities CVE-2025-22254 and CVE-2025-22251"
},
{
"date": "2025-08-12T00:00:00.000000Z",
"legacy_version": "Additional Release 6",
"number": "7",
"summary": "Added newly published upstream vulnerability CVE-2024-52965"
},
{
"date": "2025-11-11T00:00:00.000000Z",
"legacy_version": "Additional Release 7",
"number": "8",
"summary": "Added newly published upstream vulnerabilities CVE-2024-50571, CVE-2025-22258, CVE-2024-47569, CVE-2025-25252 and CVE-2025-58325"
},
{
"date": "2026-03-10T00:00:00.000000Z",
"legacy_version": "Additional Release 8",
"number": "9",
"summary": "Added newly published upstream vulnerability CVE-2025-68686"
},
{
"date": "2026-03-12T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "10",
"summary": "CISA Republication update based on Siemens ProductCERT SSA-770770 advisory"
}
],
"status": "final",
"version": "10"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0002"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM APE1808"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-42475",
"cwe": {
"id": "CWE-197",
"name": "Numeric Truncation Error"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability [CWE-122]\u00a0in FortiOS SSL-VPN 7.2.0 through 7.2.2, 7.0.0 through 7.0.8, 6.4.0 through 6.4.10, 6.2.0 through 6.2.11, 6.0.15 and earlier and FortiProxy SSL-VPN 7.2.0 through 7.2.1, 7.0.7 and earlier may allow a remote unauthenticated attacker to execute arbitrary code or commands via specifically crafted requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42475"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/197.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2022-42475"
},
{
"cve": "CVE-2023-27997",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability [CWE-122] in FortiOS version 7.2.4 and below, version 7.0.11 and below, version 6.4.12 and below, version 6.0.16 and below and FortiProxy version 7.2.3 and below, version 7.0.9 and below, version 2.0.12 and below, version 1.2 all versions, version 1.1 all versions SSL-VPN may allow a remote attacker to execute arbitrary code or commands via specifically crafted requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27997"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/122.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2023-27997"
},
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "summary",
"text": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify responses Access-Reject or Access-Accept using a chosen-prefix collision attack against MD5 Response Authenticator signature.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0004"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/924.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Use RADIUS over TLS (aka RADSEC) (https://fortiguard.fortinet.com/psirt/FG-IR-24-255)",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0004"
]
}
],
"title": "CVE-2024-3596"
},
{
"cve": "CVE-2024-21762",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A out-of-bounds write in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specifically crafted requests",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21762"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-21762"
},
{
"cve": "CVE-2024-26013",
"cwe": {
"id": "CWE-923",
"name": "Improper Restriction of Communication Channel to Intended Endpoints"
},
"notes": [
{
"category": "summary",
"text": "A improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in Fortinet FortiOS version 7.4.0 through 7.4.4, 7.2.0 through 7.2.8, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15 and before 6.2.16, Fortinet FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9 and before 7.0.15, Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and before 6.2.13, Fortinet FortiAnalyzer version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and before 6.2.13, Fortinet FortiVoice version 7.0.0 through 7.0.2 before 6.4.8 and Fortinet FortiWeb before 7.4.2 may allow an unauthenticated attacker in a man-in-the-middle position to impersonate the management device (FortiCloud server or/and in certain conditions, FortiManager), via intercepting the FGFM authentication request between the management device and the managed device",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26013"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/923.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-26013"
},
{
"cve": "CVE-2024-35279",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A stack-based buffer overflow vulnerability in Fortinet FortiOS version 7.2.4 through 7.2.8 and version 7.4.0 through 7.4.4 allows a remote unauthenticated attacker to execute arbitrary code or commands via crafted UDP packets through the CAPWAP control, provided the attacker were able to evade FortiOS stack protections and provided the fabric service is running on the exposed interface.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35279"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/121.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "For each interface, remove the fabric service or block CAPWAP-CONTROL access to port 5246 through a local-in policy (see https://fortiguard.fortinet.com/psirt/FG-IR-24-160)",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-35279"
},
{
"cve": "CVE-2024-36504",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds read vulnerability [CWE-125] in FortiOS SSLVPN web portal versions 7.4.0 through 7.4.4, versions 7.2.0 through 7.2.8, 7.0 all verisons, and 6.4 all versions may allow an authenticated attacker to perform a denial of service on the SSLVPN web portal via a specially crafted URL.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36504"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-36504"
},
{
"cve": "CVE-2024-40591",
"cwe": {
"id": "CWE-266",
"name": "Incorrect Privilege Assignment"
},
"notes": [
{
"category": "summary",
"text": "An incorrect privilege assignment vulnerability in Fortinet FortiOS version 7.6.0, 7.4.0 through 7.4.4, 7.2.0 through 7.2.9 and before 7.0.15 allows an authenticated admin whose access profile has the Security Fabric permission to escalate their privileges to super-admin by connecting the targetted FortiGate to a malicious upstream FortiGate they control.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-40591"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/266.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-40591"
},
{
"cve": "CVE-2024-45324",
"cwe": {
"id": "CWE-134",
"name": "Use of Externally-Controlled Format String"
},
"notes": [
{
"category": "summary",
"text": "A use of externally-controlled format string vulnerability in FortiOS version 7.4.0 through 7.4.4, version 7.2.0 through 7.2.9, version 7.0.0 through 7.0.15 and before 6.4.15, FortiProxy version 7.4.0 through 7.4.6, version 7.2.0 through 7.2.12 and before 7.0.19, FortiPAM version 1.4.0 through 1.4.2 and before 1.3.1, FortiSRA version 1.4.0 through 1.4.2 and before 1.3.1 and FortiWeb version 7.4.0 through 7.4.5, version 7.2.0 through 7.2.10 and before 7.0.10 allows a privileged attacker to execute unauthorized code or commands via specially crafted HTTP or HTTPS commands.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45324"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/134.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-45324"
},
{
"cve": "CVE-2024-46665",
"cwe": {
"id": "CWE-201",
"name": "Insertion of Sensitive Information Into Sent Data"
},
"notes": [
{
"category": "summary",
"text": "An insertion of sensitive information into sent data vulnerability [CWE-201] in FortiOS 7.6.0, 7.4.0 through 7.4.4 may allow an attacker in a man-in-the-middle position to retrieve the RADIUS accounting server shared secret via intercepting accounting-requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-46665"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/201.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-46665"
},
{
"cve": "CVE-2024-46666",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "An allocation of resources without limits or throttling [CWE-770] vulnerability in FortiOS versions 7.6.0, versions 7.4.4 through 7.4.0, 7.2 all versions, 7.0 all versions, 6.4 all versions may allow a remote unauthenticated attacker to prevent access to the GUI via specially crafted requests directed at specific endpoints.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-46666"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-46666"
},
{
"cve": "CVE-2024-46668",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "An allocation of resources without limits or throttling vulnerability [CWE-770] in FortiOS versions 7.4.0 through 7.4.4, versions 7.2.0 through 7.2.8, versions 7.0.0 through 7.0.15, and versions 6.4.0 through 6.4.15 may allow an unauthenticated remote user to consume all system memory via multiple large file uploads.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-46668"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-46668"
},
{
"cve": "CVE-2024-46669",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "An\u00a0Integer Overflow or Wraparound vulnerability in version 7.4.4 and below, version 7.2.10 and below; FortiSASE version 23.4.b FortiOS tenant IPsec IKE service may allow an authenticated attacker to crash the IPsec tunnel via crafted requests, resulting in potential denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-46669"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/190.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-46669"
},
{
"cve": "CVE-2024-46670",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An\u00a0Out-of-bounds Read vulnerability in FortiOS version 7.6.0, version 7.4.4 and below, version 7.2.9 and below and FortiSASE FortiOS tenant version 24.3.b IPsec IKE service may allow an unauthenticated remote attacker to trigger memory consumption leading to Denial of Service via crafted requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-46670"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-46670"
},
{
"cve": "CVE-2024-47569",
"cwe": {
"id": "CWE-201",
"name": "Insertion of Sensitive Information Into Sent Data"
},
"notes": [
{
"category": "summary",
"text": "A insertion of sensitive information into sent data in Fortinet FortiManager Cloud 7.4.1 through 7.4.3, FortiVoice 7.0.0 through 7.0.4, 6.4.0 through 6.4.9, 6.0.7 through 6.0.12, FortiMail 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.9, FortiOS 7.6.0, 7.4.0 through 7.4.4, 7.2.0 through 7.2.8, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15, 6.2.0 through 6.2.17, 6.0.0 through 6.0.18, FortiWeb 7.6.0, 7.4.0 through 7.4.4, 7.2.0 through 7.2.11, 7.0.0 through 7.0.11, 6.4.0 through 6.4.3, FortiRecorder 7.2.0 through 7.2.1, 7.0.0 through 7.0.4, FortiNDR 7.6.0 through 7.6.1, 7.4.0 through 7.4.8, 7.2.0 through 7.2.5, 7.1.0 through 7.1.1, 7.0.0 through 7.0.7, 1.5.0 through 1.5.3, FortiPAM 1.3.0 through 1.3.1, 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiTester 7.4.0 through 7.4.2, 7.3.0 through 7.3.2, 7.2.0 through 7.2.3, 7.1.0 through 7.1.1, 7.0.0, 4.2.0 through 4.2.1, FortiProxy 7.4.0 through 7.4.4, 7.2.0 through 7.2.10, 7.0.0 through 7.0.21, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiManager 7.6.0 through 7.6.1, 7.4.1 through 7.4.3 allows attacker to disclose sensitive information via specially crafted packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-47569"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/201.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-47569"
},
{
"cve": "CVE-2024-48884",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A improper limitation of a pathname to a restricted directory (\u0027path traversal\u0027) in Fortinet FortiManager versions 7.6.0 through 7.6.1, 7.4.1 through 7.4.3, FortiOS versions 7.6.0, 7.4.0 through 7.4.4, 7.2.5 through 7.2.9, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15, FortiProxy 7.4.0 through 7.4.5, 7.2.0 through 7.2.11, 7.0.0 through 7.0.18, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiManager Cloud versions 7.4.1 through 7.4.3 allows attacker to trigger an escalation of privilege via specially crafted packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-48884"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-48884"
},
{
"cve": "CVE-2024-48885",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A improper limitation of a pathname to a restricted directory (\u0027path traversal\u0027) in Fortinet FortiRecorder versions 7.2.0 through 7.2.1, 7.0.0 through 7.0.4, FortiWeb versions 7.6.0, 7.4.0 through 7.4.4, 7.2.0 through 7.2.10, 7.0.0 through 7.0.10, 6.4.0 through 6.4.3, FortiVoice versions 7.0.0 through 7.0.4, 6.4.0 through 6.4.9, 6.0.0 through 6.0.12 allows attacker to escalate privilege via specially crafted packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-48885"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-48885"
},
{
"cve": "CVE-2024-48886",
"cwe": {
"id": "CWE-1390",
"name": "Weak Authentication"
},
"notes": [
{
"category": "summary",
"text": "A weak authentication in Fortinet FortiOS versions 7.4.0 through 7.4.4, 7.2.0 through 7.2.8, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15, FortiProxy versions 7.4.0 through 7.4.4, 7.2.0 through 7.2.10, 7.0.0 through 7.0.17, 2.0.0 through 2.0.14, FortiManager versions 7.6.0 through 7.6.1, 7.4.1 through 7.4.3, FortiManager Cloud versions 7.4.1 through 7.4.3, FortiAnalyzer Cloud versions 7.4.1 through 7.4.3 allows attacker to execute unauthorized code or commands via a brute-force attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-48886"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/1390.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-48886"
},
{
"cve": "CVE-2024-50563",
"cwe": {
"id": "CWE-1390",
"name": "Weak Authentication"
},
"notes": [
{
"category": "summary",
"text": "A weak authentication in Fortinet FortiManager Cloud, FortiAnalyzer versions 7.6.0 through 7.6.1, 7.4.1 through 7.4.3, FortiAnalyzer Cloud versions 7.4.1 through 7.4.3, FortiManager versions 7.6.0 through 7.6.1, 7.4.1 through 7.4.3, FortiManager Cloud versions 7.4.1 through 7.4.3 allows attacker to execute unauthorized code or commands via a brute-force attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-50563"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/1390.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-50563"
},
{
"cve": "CVE-2024-50565",
"cwe": {
"id": "CWE-300",
"name": "Channel Accessible by Non-Endpoint"
},
"notes": [
{
"category": "summary",
"text": "A improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in Fortinet FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15 and 6.2.0 through 6.2.16, Fortinet FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15 and 2.0.0 through 2.0.14, Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and 6.2.0 through 6.2.13, Fortinet FortiAnalyzer version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and 6.2.0 through 6.2.13, Fortinet FortiVoice version 7.0.0 through 7.0.2, 6.4.0 through 6.4.8 and 6.0.0 through 6.0.12 and Fortinet FortiWeb version 7.4.0 through 7.4.2, 7.2.0 through 7.2.10, 7.0.0 through 7.0.10 allows an unauthenticated attacker in a man-in-the-middle position to impersonate the management device (FortiCloud server or/and in certain conditions, FortiManager), via intercepting the FGFM authentication request between the management device and the managed device",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-50565"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/300.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-50565"
},
{
"cve": "CVE-2024-50571",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow in Fortinet FortiOS 7.6.0 through 7.6.1, 7.4.0 through 7.4.5, 7.2.0 through 7.2.10, 7.0.0 through 7.0.16, 6.4.0 through 6.4.15, 6.2.0 through 6.2.17, FortiManager Cloud 7.6.2, 7.4.1 through 7.4.5, 7.2.1 through 7.2.8, 7.0.1 through 7.0.13, 6.4.1 through 6.4.7, FortiAnalyzer Cloud 7.4.1 through 7.4.5, 7.2.1 through 7.2.8, 7.0.1 through 7.0.13, 6.4.1 through 6.4.7, FortiProxy 7.6.0, 7.4.0 through 7.4.6, 7.2.0 through 7.2.12, 7.0.0 through 7.0.19, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiAnalyzer 7.6.0 through 7.6.2, 7.4.0 through 7.4.5, 7.2.0 through 7.2.8, 7.0.0 through 7.0.13, 6.4.0 through 6.4.15, 6.2.0 through 6.2.13, 6.0.0 through 6.0.12, FortiManager 7.6.0 through 7.6.1, 7.4.0 through 7.4.5, 7.2.0 through 7.2.9, 7.0.0 through 7.0.13, 6.4.0 through 6.4.15, 6.2.0 through 6.2.13, 6.0.0 through 6.0.12 allows attacker to execute unauthorized code or commands via specifically crafted requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-50571"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/122.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-50571"
},
{
"cve": "CVE-2024-52965",
"cwe": {
"id": "CWE-304",
"name": "Missing Critical Step in Authentication"
},
"notes": [
{
"category": "summary",
"text": "A missing critical step in authentication vulnerability [CWE-304] in Fortinet FortiOS version 7.6.0 through 7.6.1, 7.4.0 through 7.4.5, 7.2.0 through 7.2.10, and before 7.0.16 \u0026 FortiProxy version 7.6.0 through 7.6.1, 7.4.0 through 7.4.8, 7.2.0 through 7.2.13 and before 7.0.20 allows an API-user using api-key + PKI user certificate authentication to login even if the certificate is invalid.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0004"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-52965"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/304.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0004"
]
}
],
"title": "CVE-2024-52965"
},
{
"cve": "CVE-2024-54021",
"cwe": {
"id": "CWE-113",
"name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An improper neutralization of crlf sequences in http headers (\u0027http response splitting\u0027) in Fortinet FortiOS 7.2.0 through 7.6.0, FortiProxy 7.2.0 through 7.4.5 allows attacker to execute unauthorized code or commands via crafted HTTP header.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-54021"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/113.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2024-54021"
},
{
"cve": "CVE-2025-22251",
"cwe": {
"id": "CWE-923",
"name": "Improper Restriction of Communication Channel to Intended Endpoints"
},
"notes": [
{
"category": "summary",
"text": "An improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in FortiOS 7.6.0, 7.4.0 through 7.4.5, 7.2 all versions, 7.0 all versions, 6.4 all versions may allow an unauthenticated attacker to inject unauthorized sessions via crafted FGSP session synchronization packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0004"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22251"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/923.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0004"
]
}
],
"title": "CVE-2025-22251"
},
{
"cve": "CVE-2025-22252",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "A missing authentication for critical function vulnerability in FortiOS, FortiProxy, and FortiSwitchManager TACACS+ configured to use a remote TACACS+ server for authentication, that has itself been configured to use ASCII authentication may allow an attacker with knowledge of an existing admin account to access the device as a valid admin via an authentication bypass.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22252"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/306.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Use alternate authentication mechanism such as PAP, MSCHAP, and CHAP configurations other than ASCII authentication (see https://www.fortiguard.com/psirt/FG-IR-24-472)",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0003"
]
}
],
"title": "CVE-2025-22252"
},
{
"cve": "CVE-2025-22254",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "summary",
"text": "An Improper Privilege Management vulnerability [CWE-269] affecting Fortinet FortiOS version 7.6.0 through 7.6.1, 7.4.0 through 7.4.6, 7.2.0 through 7.2.10, 7.0.0 through 7.0.16 and before 6.4.15, FortiProxy version 7.6.0 through 7.6.1 and before 7.4.7 \u0026 FortiWeb version 7.6.0 through 7.6.1 and before 7.4.6 allows an authenticated attacker with at least read-only admin permissions to gain super-admin privileges via crafted requests to\u00a0Node.js websocket module.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0004"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22254"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/269.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:H/RL:W/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:H/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0004"
]
}
],
"title": "CVE-2025-22254"
},
{
"cve": "CVE-2025-22258",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow in Fortinet FortiSRA 1.5.0, 1.4.0 through 1.4.2, FortiPAM 1.5.0, 1.4.0 through 1.4.2, 1.3.0 through 1.3.1, 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiProxy 7.6.0 through 7.6.1, 7.4.0 through 7.4.7, FortiOS 7.6.0 through 7.6.2, 7.4.0 through 7.4.6, 7.2.0 through 7.2.10, 7.0.2 through 7.0.16, FortiSwitchManager 7.2.1 through 7.2.5 allows attackers to escalate their privilege via specially crafted http requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22258"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/122.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2025-22258"
},
{
"cve": "CVE-2025-25252",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "An Insufficient Session Expiration vulnerability [CWE-613] in FortiOS SSL VPN 7.6.0 through 7.6.2, 7.4.0 through 7.4.6, 7.2.0 through 7.2.10, 7.0.0 through 7.0.16, 6.4 all versions may allow a remote attacker (e.g. a former admin whose account was removed and whose session was terminated) in possession of the SAML record of a user session to access or re-open that session via re-use of SAML record.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-25252"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/613.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2025-25252"
},
{
"cve": "CVE-2025-58325",
"cwe": {
"id": "CWE-684",
"name": "Incorrect Provision of Specified Functionality"
},
"notes": [
{
"category": "summary",
"text": "An Incorrect Provision of Specified Functionality vulnerability [CWE-684] in FortiOS 7.6.0, 7.4.0 through 7.4.5, 7.2.5 through 7.2.10, 7.0.0 through 7.0.15, 6.4 all versions may allow a local authenticated attacker to execute system commands via crafted CLI commands.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-58325"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/684.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Refer to Fortinet Blog for mitigation measures https://www.fortinet.com/blog/psirt-blogs/analysis-of-threat-actor-activity",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2025-58325"
},
{
"cve": "CVE-2025-68686",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "An Exposure of Sensitive Information to an Unauthorized Actor vulnerability [CWE-200] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.1, FortiOS 7.4.0 through 7.4.6, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions may allow a remote unauthenticated attacker to bypass the patch developed for the symbolic link persistency mechanism observed in some post-exploit cases, via crafted HTTP requests. An attacker would need first to have compromised the product via another vulnerability, at filesystem level.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-68686"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Fortigate NGFW to V7.4.7. Contact customer support to receive patch and update information",
"product_ids": [
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2025-68686"
}
]
}
ICSA-25-135-05
Vulnerability from csaf_cisa - Published: 2025-05-13 00:00 - Updated: 2025-11-11 00:00Summary
Siemens SIPROTEC and SICAM
Notes
Summary: This advisory documents the impact of CVE-2024-3596 (also dubbed "Blastradius"), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products.
The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in a way that enables them to modify the corresponding server response packet at will, e.g., turning an "Access-Reject" message into an "Access-Accept". This would cause the Network Access Server to grant the attackers access to the network with the attackers desired authorization (and without the need of knowing or guessing legitimate access credentials).
Further details incl. external references can be found in the chapter "Additional Information".
Siemens has released new versions for several affected products and recommends to update to the latest versions, and to configure the updated systems as recommended in the chapter "Additional Information".
Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. See chapter "Additional Information" for details.
General Recommendations: Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design.
Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment.
As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.
Recommended security guidelines can be found at:
https://www.siemens.com/gridsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Siemens ProductCERT SSA-794185 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
9.0 (Critical)
Affected products
Known affected
53 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
CPC80 Central Processing/Communication
Siemens / CPC80 Central Processing/Communication
|
vers:intdot/<16.51 |
Mitigation
Mitigation
Vendor Fix
|
|
|
CPCI85 Central Processing/Communication
Siemens / CPCI85 Central Processing/Communication
|
vers:intdot/<6.20 |
Mitigation
Mitigation
Vendor Fix
|
|
|
POWER METER SICAM Q100 family
Siemens / POWER METER SICAM Q100 family
|
vers:intdot/<2.70 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
POWER METER SICAM Q200 family
Siemens / POWER METER SICAM Q200 family
|
vers:intdot/<2.83 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
Powerlink IP
Siemens / Powerlink IP
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SICAM GridPass
Siemens / SICAM GridPass
|
vers:intdot/<2.50 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SICORE Base system
Siemens / SICORE Base system
|
vers:intdot/<2.20.0 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 6MD84 (CP300)
Siemens / SIPROTEC 5 6MD84 (CP300)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 6MD85 (CP300)
Siemens / SIPROTEC 5 6MD85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 6MD86 (CP300)
Siemens / SIPROTEC 5 6MD86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 6MD89 (CP300)
Siemens / SIPROTEC 5 6MD89 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 6MD89 (CP300) V9.6x
Siemens / SIPROTEC 5 6MD89 (CP300) V9.6x
|
vers:intdot/<9.68 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 6MU85 (CP300)
Siemens / SIPROTEC 5 6MU85 (CP300)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7KE85 (CP300)
Siemens / SIPROTEC 5 7KE85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SA82 (CP100)
Siemens / SIPROTEC 5 7SA82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SA82 (CP150)
Siemens / SIPROTEC 5 7SA82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SA86 (CP300)
Siemens / SIPROTEC 5 7SA86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SA87 (CP300)
Siemens / SIPROTEC 5 7SA87 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SD82 (CP100)
Siemens / SIPROTEC 5 7SD82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SD82 (CP150)
Siemens / SIPROTEC 5 7SD82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SD86 (CP300)
Siemens / SIPROTEC 5 7SD86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SD87 (CP300)
Siemens / SIPROTEC 5 7SD87 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SJ81 (CP100)
Siemens / SIPROTEC 5 7SJ81 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SJ81 (CP150)
Siemens / SIPROTEC 5 7SJ81 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SJ82 (CP100)
Siemens / SIPROTEC 5 7SJ82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SJ82 (CP150)
Siemens / SIPROTEC 5 7SJ82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SJ85 (CP300)
Siemens / SIPROTEC 5 7SJ85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SJ86 (CP300)
Siemens / SIPROTEC 5 7SJ86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SK82 (CP100)
Siemens / SIPROTEC 5 7SK82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SK82 (CP150)
Siemens / SIPROTEC 5 7SK82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SK85 (CP300)
Siemens / SIPROTEC 5 7SK85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SL82 (CP100)
Siemens / SIPROTEC 5 7SL82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7SL82 (CP150)
Siemens / SIPROTEC 5 7SL82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SL86 (CP300)
Siemens / SIPROTEC 5 7SL86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SL87 (CP300)
Siemens / SIPROTEC 5 7SL87 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SS85 (CP300)
Siemens / SIPROTEC 5 7SS85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7ST85 (CP300)
Siemens / SIPROTEC 5 7ST85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7ST85 (CP300) V9.6x
Siemens / SIPROTEC 5 7ST85 (CP300) V9.6x
|
vers:intdot/<9.68 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7ST86 (CP300)
Siemens / SIPROTEC 5 7ST86 (CP300)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7ST86 (CP300) V9.8x
Siemens / SIPROTEC 5 7ST86 (CP300) V9.8x
|
vers:intdot/<9.83 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SX82 (CP150)
Siemens / SIPROTEC 5 7SX82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SX85 (CP300)
Siemens / SIPROTEC 5 7SX85 (CP300)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7SY82 (CP150)
Siemens / SIPROTEC 5 7SY82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7UM85 (CP300)
Siemens / SIPROTEC 5 7UM85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7UT82 (CP100)
Siemens / SIPROTEC 5 7UT82 (CP100)
|
vers:intdot/>=7.80|<8.90 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIPROTEC 5 7UT82 (CP150)
Siemens / SIPROTEC 5 7UT82 (CP150)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7UT85 (CP300)
Siemens / SIPROTEC 5 7UT85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7UT86 (CP300)
Siemens / SIPROTEC 5 7UT86 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7UT87 (CP300)
Siemens / SIPROTEC 5 7UT87 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7VE85 (CP300)
Siemens / SIPROTEC 5 7VE85 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7VK87 (CP300)
Siemens / SIPROTEC 5 7VK87 (CP300)
|
vers:intdot/>=7.80|<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 7VU85 (CP300)
Siemens / SIPROTEC 5 7VU85 (CP300)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIPROTEC 5 Compact 7SX800 (CP050)
Siemens / SIPROTEC 5 Compact 7SX800 (CP050)
|
vers:intdot/<10.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
Known not affected
6 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SICAM AK 3
Siemens / SICAM AK 3
|
vers:all/* | ||
|
SICAM BC
Siemens / SICAM BC
|
vers:all/* | ||
|
SICAM GridEdge (Classic)
Siemens / SICAM GridEdge (Classic)
|
vers:all/* | ||
|
SICAM GridEdge Applications for SICAM 8 Platform
Siemens / SICAM GridEdge Applications for SICAM 8 Platform
|
vers:all/* | ||
|
SICAM TM
Siemens / SICAM TM
|
vers:all/* | ||
|
SIPROTEC 5 - CP200 Devices
Siemens / SIPROTEC 5 - CP200 Devices
|
vers:all/* |
Threats
Impact
The product does not support the RADIUS protocol.
Impact
The product includes a component which also supports the RADIUS protocol, but the product doesn't enable or support RADIUS.
References
10 references
Acknowledgments
Siemens
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "This advisory documents the impact of CVE-2024-3596 (also dubbed \"Blastradius\"), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products.\n\nThe vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in a way that enables them to modify the corresponding server response packet at will, e.g., turning an \"Access-Reject\" message into an \"Access-Accept\". This would cause the Network Access Server to grant the attackers access to the network with the attackers desired authorization (and without the need of knowing or guessing legitimate access credentials).\n\nFurther details incl. external references can be found in the chapter \"Additional Information\".\nSiemens has released new versions for several affected products and recommends to update to the latest versions, and to configure the updated systems as recommended in the chapter \"Additional Information\".\nSiemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. See chapter \"Additional Information\" for details.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\nhttps://www.siemens.com/gridsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-794185 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-794185: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SIPROTEC, SICAM and Related Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-794185.json"
},
{
"category": "self",
"summary": "SSA-794185: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SIPROTEC, SICAM and Related Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-135-05 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-135-05.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-135-05 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-05"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens SIPROTEC and SICAM",
"tracking": {
"current_release_date": "2025-11-11T00:00:00.000000Z",
"generator": {
"date": "2025-11-13T20:52:53.543298Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-135-05",
"initial_release_date": "2025-05-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2025-05-13T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-08-12T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for affected firmware modules in SICAM A8000 (CPCI85 for CP-8031/CP-8050, CPC80 for CP-8000/CP-8021/CP-8022, SICORE for CP-8010/CP-8012), SICAM EGS (CPCI85) and SICAM S8000 (SICORE). Added fix for SICAM Q200, for SIPROTEC 5 - CP300 and CP150 Devices, and for SIPROTEC 5 Compact 7SX800 (CP050). Added SICAM AK 3, SICAM BC, SICAM TM, SICAM GridEdge and SIPROTEC 5 - CP200 Devices to the list of known not affected products"
},
{
"date": "2025-11-11T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for SIPROTEC 5 - CP100 Devices"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c16.51",
"product": {
"name": "CPC80 Central Processing/Communication",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "CPC80 Central Processing/Communication"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.20",
"product": {
"name": "CPCI85 Central Processing/Communication",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "CPCI85 Central Processing/Communication"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.70",
"product": {
"name": "POWER METER SICAM Q100 family",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "POWER METER SICAM Q100 family"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.83",
"product": {
"name": "POWER METER SICAM Q200 family",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "POWER METER SICAM Q200 family"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Powerlink IP",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Powerlink IP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICAM AK 3",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SICAM AK 3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICAM BC",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SICAM BC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICAM GridEdge (Classic)",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SICAM GridEdge (Classic)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICAM GridEdge Applications for SICAM 8 Platform",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SICAM GridEdge Applications for SICAM 8 Platform"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.50",
"product": {
"name": "SICAM GridPass",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "SICAM GridPass"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICAM TM",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "SICAM TM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.20.0",
"product": {
"name": "SICORE Base system",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "SICORE Base system"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPROTEC 5 - CP200 Devices",
"product_id": "CSAFPID-0013"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 - CP200 Devices"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 6MD84 (CP300)",
"product_id": "CSAFPID-0014"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MD84 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 6MD85 (CP300)",
"product_id": "CSAFPID-0015"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MD85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 6MD86 (CP300)",
"product_id": "CSAFPID-0016"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MD86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 6MD89 (CP300)",
"product_id": "CSAFPID-0017"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MD89 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c9.68",
"product": {
"name": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"product_id": "CSAFPID-0018"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MD89 (CP300) V9.6x"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 6MU85 (CP300)",
"product_id": "CSAFPID-0019"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 6MU85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7KE85 (CP300)",
"product_id": "CSAFPID-0020"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7KE85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SA82 (CP100)",
"product_id": "CSAFPID-0021"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SA82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SA82 (CP150)",
"product_id": "CSAFPID-0022"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SA82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SA86 (CP300)",
"product_id": "CSAFPID-0023"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SA86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SA87 (CP300)",
"product_id": "CSAFPID-0024"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SA87 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SD82 (CP100)",
"product_id": "CSAFPID-0025"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SD82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SD82 (CP150)",
"product_id": "CSAFPID-0026"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SD82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SD86 (CP300)",
"product_id": "CSAFPID-0027"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SD86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SD87 (CP300)",
"product_id": "CSAFPID-0028"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SD87 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SJ81 (CP100)",
"product_id": "CSAFPID-0029"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ81 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SJ81 (CP150)",
"product_id": "CSAFPID-0030"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ81 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SJ82 (CP100)",
"product_id": "CSAFPID-0031"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SJ82 (CP150)",
"product_id": "CSAFPID-0032"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SJ85 (CP300)",
"product_id": "CSAFPID-0033"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SJ86 (CP300)",
"product_id": "CSAFPID-0034"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SJ86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SK82 (CP100)",
"product_id": "CSAFPID-0035"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SK82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SK82 (CP150)",
"product_id": "CSAFPID-0036"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SK82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SK85 (CP300)",
"product_id": "CSAFPID-0037"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SK85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7SL82 (CP100)",
"product_id": "CSAFPID-0038"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SL82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SL82 (CP150)",
"product_id": "CSAFPID-0039"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SL82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SL86 (CP300)",
"product_id": "CSAFPID-0040"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SL86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SL87 (CP300)",
"product_id": "CSAFPID-0041"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SL87 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SS85 (CP300)",
"product_id": "CSAFPID-0042"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SS85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7ST85 (CP300)",
"product_id": "CSAFPID-0043"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7ST85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c9.68",
"product": {
"name": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"product_id": "CSAFPID-0044"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7ST85 (CP300) V9.6x"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7ST86 (CP300)",
"product_id": "CSAFPID-0045"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7ST86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c9.83",
"product": {
"name": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"product_id": "CSAFPID-0046"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7ST86 (CP300) V9.8x"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SX82 (CP150)",
"product_id": "CSAFPID-0047"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SX82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SX85 (CP300)",
"product_id": "CSAFPID-0048"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SX85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7SY82 (CP150)",
"product_id": "CSAFPID-0049"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7SY82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7UM85 (CP300)",
"product_id": "CSAFPID-0050"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UM85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c8.90",
"product": {
"name": "SIPROTEC 5 7UT82 (CP100)",
"product_id": "CSAFPID-0051"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UT82 (CP100)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7UT82 (CP150)",
"product_id": "CSAFPID-0052"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UT82 (CP150)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7UT85 (CP300)",
"product_id": "CSAFPID-0053"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UT85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7UT86 (CP300)",
"product_id": "CSAFPID-0054"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UT86 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7UT87 (CP300)",
"product_id": "CSAFPID-0055"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7UT87 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7VE85 (CP300)",
"product_id": "CSAFPID-0056"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7VE85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.80|\u003c10.0",
"product": {
"name": "SIPROTEC 5 7VK87 (CP300)",
"product_id": "CSAFPID-0057"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7VK87 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 7VU85 (CP300)",
"product_id": "CSAFPID-0058"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 7VU85 (CP300)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c10.0",
"product": {
"name": "SIPROTEC 5 Compact 7SX800 (CP050)",
"product_id": "CSAFPID-0059"
}
}
],
"category": "product_name",
"name": "SIPROTEC 5 Compact 7SX800 (CP050)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"flags": [
{
"label": "vulnerable_code_not_present",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0009",
"CSAFPID-0013",
"CSAFPID-0007",
"CSAFPID-0011"
]
},
{
"label": "vulnerable_code_not_in_execute_path",
"product_ids": [
"CSAFPID-0008"
]
}
],
"notes": [
{
"category": "summary",
"text": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify responses Access-Reject or Access-Accept using a chosen-prefix collision attack against MD5 Response Authenticator signature.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059"
],
"known_not_affected": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0011",
"CSAFPID-0013"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Con\ufb01gure the RADIUS server to require the presence of a Message-Authenticator attribute in all Access-Request packets from RADIUS client devices that support it",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059"
]
},
{
"category": "mitigation",
"details": "Restrict access to the networks where RADIUS messages are exchanged (e.g., send RADIUS traffic via management network or a dedicated VLAN)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Update to V10.0 or later version",
"product_ids": [
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0037",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0045",
"CSAFPID-0048",
"CSAFPID-0050",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109814150/"
},
{
"category": "vendor_fix",
"details": "Update to V10.0 or later version",
"product_ids": [
"CSAFPID-0022",
"CSAFPID-0026",
"CSAFPID-0030",
"CSAFPID-0032",
"CSAFPID-0036",
"CSAFPID-0039",
"CSAFPID-0047",
"CSAFPID-0049",
"CSAFPID-0052"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109757433/"
},
{
"category": "vendor_fix",
"details": "Update to V10.0 or later version",
"product_ids": [
"CSAFPID-0059"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109796884/"
},
{
"category": "vendor_fix",
"details": "Update to V16.51 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.20.0 or later version",
"product_ids": [
"CSAFPID-0012"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.50 or later version",
"product_ids": [
"CSAFPID-0010"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109763384/"
},
{
"category": "vendor_fix",
"details": "Update to V2.70 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109743524/"
},
{
"category": "vendor_fix",
"details": "Update to V2.83 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109743592/"
},
{
"category": "vendor_fix",
"details": "Update to V6.20 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V9.68 or later version",
"product_ids": [
"CSAFPID-0018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109742950/"
},
{
"category": "vendor_fix",
"details": "Update to V9.68 or later version",
"product_ids": [
"CSAFPID-0044"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109740299/"
},
{
"category": "vendor_fix",
"details": "Update to V9.83 or later version",
"product_ids": [
"CSAFPID-0046"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109768428/"
},
{
"category": "vendor_fix",
"details": "Update to V8.90 or later V8.xx version",
"product_ids": [
"CSAFPID-0021",
"CSAFPID-0025",
"CSAFPID-0029",
"CSAFPID-0031",
"CSAFPID-0035",
"CSAFPID-0038",
"CSAFPID-0051"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059"
]
}
],
"threats": [
{
"category": "impact",
"details": "The product does not support the RADIUS protocol.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0009",
"CSAFPID-0013",
"CSAFPID-0007",
"CSAFPID-0011"
]
},
{
"category": "impact",
"details": "The product includes a component which also supports the RADIUS protocol, but the product doesn\u0027t enable or support RADIUS.",
"product_ids": [
"CSAFPID-0008"
]
}
],
"title": "CVE-2024-3596"
}
]
}
ICSA-25-350-03
Vulnerability from csaf_cisa - Published: 2025-12-16 07:00 - Updated: 2025-12-16 07:00Summary
Hitachi Energy AFS, AFR and AFF Series
Notes
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Risk evaluation: Successful exploitation of this vulnerability could compromise the integrity of the product data and disrupt its availability.
Critical infrastructure sectors: Energy
Countries/areas deployed: Worldwide
Company headquarters location: Switzerland
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
Recommended Practices: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices: CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices: Do not click web links or open attachments in unsolicited email messages.
Recommended Practices: Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Recommended Practices: Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
Recommended Practices: No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
9.0 (Critical)
Affected products
Known affected
11 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Hitachi Energy AFS 660-B/C/S: vers:all/*
Hitachi Energy / AFS 660-B/C/S
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 665-B/S: vers:all/*
Hitachi Energy / AFS 665-B/S
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 670 v2.0: vers:all/*
Hitachi Energy / AFS 670 v2.0
|
vers:all/* |
Mitigation
Mitigation
Mitigation
fix
|
|
|
Hitachi Energy AFS 650: vers:all/*
Hitachi Energy / AFS 650
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 655: vers:all/*
Hitachi Energy / AFS 655
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 670: vers:all/*
Hitachi Energy / AFS 670
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 675: vers:all/*
Hitachi Energy / AFS 675
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFS 677: vers:all/*
Hitachi Energy / AFS 677
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFR 677: vers:all/*
Hitachi Energy / AFR 677
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFF 660: vers:all/*
Hitachi Energy / AFF 660
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
|
|
Hitachi Energy AFF 665: vers:all/*
Hitachi Energy / AFF 665
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
|
References
15 references
Acknowledgments
Hitachi Energy
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi Energy",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could compromise the integrity of the product data and disrupt its availability.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Do not click web links or open attachments in unsolicited email messages.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-350-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-350-03.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-350-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-350-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
}
],
"title": "Hitachi Energy AFS, AFR and AFF Series",
"tracking": {
"current_release_date": "2025-12-16T07:00:00.000000Z",
"generator": {
"date": "2025-12-16T15:51:45.119467Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-350-03",
"initial_release_date": "2025-12-16T07:00:00.000000Z",
"revision_history": [
{
"date": "2025-12-16T07:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 660-B/C/S: vers:all/*",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "AFS 660-B/C/S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 665-B/S: vers:all/*",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "AFS 665-B/S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 670 v2.0: vers:all/*",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "AFS 670 v2.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 650: vers:all/*",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "AFS 650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 655: vers:all/*",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "AFS 655"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 670: vers:all/*",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "AFS 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 675: vers:all/*",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "AFS 675"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFS 677: vers:all/*",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "AFS 677"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFR 677: vers:all/*",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "AFR 677"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFF 660: vers:all/*",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "AFF 660"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Hitachi Energy AFF 665: vers:all/*",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "AFF 665"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "summary",
"text": "The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid response (access-accept, access-reject, or access-challenge) to any other response using a chosen-prefix collision attack against the MD5 response authenticator signature.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Hitachi Energy has identified the following recommended immediate actions:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
{
"category": "mitigation",
"details": "All affected products: Set the RADIUS configuration to default which enables the RADIUS server message authenticator option.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
{
"category": "vendor_fix",
"details": "AFR 677, AFS 650, AFS 655, AFS 670, AFS 675, AFS 677: Command to enable Message Authenticator option: For AFS65x, AFS67x, AFR67x CLI: radius server msgauth MIB: hmAgentRadiusServerMsgAuth",
"product_ids": [
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
{
"category": "vendor_fix",
"details": "AFF 660, AFF 665, AFS 660-B/C/S, AFS 665-B/S, AFS 670: Command to enable Message Authenticator option: For AFS66x, AFS670 v2.0, AFF66x CLI: radius server auth modify msgauth MIB: hm2AgentRadiusServerMsgAuth",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0006",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
{
"category": "mitigation",
"details": "For more information, see the associated Hitachi Energy PSIRT security advisory 8DBD000230 RADIUS vulnerability in Hitachi Energy AFS, AFR and AFF series products.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
]
}
]
}
ICSA-26-036-05
Vulnerability from csaf_cisa - Published: 2026-01-27 00:00 - Updated: 2026-02-05 07:00Summary
Hitachi Energy XMC20
Severity
Critical
Notes
Summary: Hitachi Energy is aware of a vulnerability that affects XMC20 product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only if XMC20 devices are configured to use remote RADIUS authentication.
Notice: The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.
Support: For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.
General Mitigation Factors: Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000233 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Switzerland
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker. An attacker can modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response using a chosen-prefix collision attack targeting the MD5 Response Authenticator signature.
9 (Critical)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
XMC20 version R18
Hitachi Energy / XMC20
|
R18 |
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
XMC20 version R17A and earlier
Hitachi Energy / XMC20
|
vers:XMC20/<=R17A |
Vendor Fix
Mitigation
Mitigation
Mitigation
|
References
13 references
Acknowledgments
Hitachi Energy
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi Energy",
"summary": "reported this vulnerability to CISA."
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/specification-document",
"text": "CRITICAL"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Hitachi Energy is aware of a vulnerability that affects XMC20 product versions listed in this document. Successful exploitation of this vulnerability can lead to forgery attacks potentially causing impact on confidentiality, integrity and availability for the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. Note: This is applicable only if XMC20 devices are configured to use remote RADIUS authentication.",
"title": "Summary"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.",
"title": "Notice"
},
{
"category": "general",
"text": "For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.",
"title": "Support"
},
{
"category": "general",
"text": "Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed.",
"title": "General Mitigation Factors"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000233 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-26-036-05 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-036-05.json"
},
{
"category": "self",
"summary": "[1] 1KHW029001 XMC20 R18 Technical User Documentation (Access to Hitachi Energy Publisher is required).",
"url": "https://publisher.hitachienergy.com/preview?DocumentID=1KHW029001\u0026LanguageCode=en\u0026DocumentPartId=R18\u0026Action=launch"
},
{
"category": "self",
"summary": "Radius MD5 Vulnerability in Hitachi Energy XMC20 product",
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000233\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-036-05 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-036-05"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Hitachi Energy XMC20",
"tracking": {
"current_release_date": "2026-02-05T07:00:00.000000Z",
"generator": {
"date": "2026-02-04T21:49:05.189634Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-036-05",
"initial_release_date": "2026-01-27T00:00:00.000000Z",
"revision_history": [
{
"date": "2026-01-27T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial public release"
},
{
"date": "2026-02-05T07:00:00.000000Z",
"legacy_version": "CISA Republication",
"number": "2",
"summary": "Initial CISA Republication of Hitachi Energy PSIRT 8DBD000233 advisory"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "R18",
"product": {
"name": "XMC20 version R18",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version_range",
"name": "vers:XMC20/\u003c=R17A",
"product": {
"name": "XMC20 version R17A and earlier",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "XMC20"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-3596",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "description",
"text": "The RADIUS protocol under RFC 2865 is susceptible to forgery attacks by a local attacker. An attacker can modify any valid response (Access-Accept, Access-Reject, or Access-Challenge) into another response using a chosen-prefix collision attack targeting the MD5 Response Authenticator signature."
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/924.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Enable the RADIUS Message-Authenticator option in both the XMC20 and RADIUS server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029001\u0026LanguageCode=en\u0026DocumentPartId=R18\u0026Action=launch.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to XMC20 R18 and then enable the RADIUS Message-Authenticator option in both the XMC20 and RADIUS server configurations. Refer to the Technical User Documentation at https://publisher.hitachienergy.com/preview?DocumentID=1KHW029001\u0026LanguageCode=en\u0026DocumentPartId=R18\u0026Action=launch.",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If the upgrade is not possible, apply general mitigation factors with segmentation of FOX management traffic to minimize the risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information, see the associated Hitachi Energy cybersecurity advisory 8DBD000233 RADIUS MD5 Vulnerability in Hitachi Energy XMC20 product available in PDF format here https://publisher.hitachienergy.com/preview?DocumentID=8DBD000233\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch or JSON format here https://publisher.hitachienergy.com/preview?DocumentID=8DBD000233-CSAF\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Hitachi Energy recommends implementing security practices and firewall configurations to help protect process control networks from external attacks. Such practices include ensuring that process control systems are physically protected from unauthorized access, have no direct Internet connections, and are separated from other networks by a firewall system that minimizes exposed ports, and any additional ports should be evaluated on a case-by-case basis. Process control systems should not be used for web browsing, instant messaging, or email. Portable computers and removable storage media should be thoroughly scanned for malware before being connected to a control system. Organizations should enforce proper password policies and procedures.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2024-3596"
}
]
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…