CVE-2024-23766 (GCVE-0-2024-23766)

Vulnerability from cvelistv5 – Published: 2024-06-26 00:00 – Updated: 2025-03-13 18:29
VLAI
Summary
An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-27 18:33 UTC
CWE
  • n/a
  • CWE-598 - Use of GET Request Method With Sensitive Query Strings
Impacted products
Vendor Product Version CPE status
hms-networks anybus_x-gateway_ab7832-f3 Affected: 0 , < * (custom)
    cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "anybus_x-gateway_ab7832-f3",
            "vendor": "hms-networks",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-23766",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-27T18:33:51.318160Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-598",
                "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T18:29:11.265Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:13:07.259Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T20:50:23.197Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-23766",
    "datePublished": "2024-06-26T00:00:00.000Z",
    "dateReserved": "2024-01-22T00:00:00.000Z",
    "dateUpdated": "2025-03-13T18:29:11.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-23766",
      "date": "2026-09-23",
      "epss": "0.00441",
      "percentile": "0.3775"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f3",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL."
          },
          {
            "lang": "es",
            "value": " Se descubri\u00f3 un problema en los dispositivos HMS Anybus X-Gateway AB7832-F 3. La puerta de enlace expone una interfaz web en el puerto 80. Una solicitud GET no autenticada a una URL espec\u00edfica desencadena el reinicio de la puerta de enlace Anybus (o al menos de la mayor\u00eda de sus m\u00f3dulos). Un atacante puede utilizar esta funci\u00f3n para llevar a cabo un ataque de denegaci\u00f3n de servicio enviando continuamente solicitudes GET a esa URL."
          }
        ],
        "id": "CVE-2024-23766",
        "lastModified": "2026-06-17T07:13:33.590",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-23766",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-27T18:33:51.318160Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-06-26T21:15:12.977",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-598"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T20:36:19+00:00",
      "cve": "CVE-2024-23766",
      "id": "CVE-2024-23766",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-23766",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-23766.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:13:07.259Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:hms-networks:anybus_x-gateway_ab7832-f3:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "anybus_x-gateway_ab7832-f3",
                "vendor": "hms-networks",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-23766",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-27T18:33:51.318160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-598",
                    "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-27T19:00:11.169Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on HMS Anybus X-Gateway AB7832-F 3 devices. The gateway exposes a web interface on port 80. An unauthenticated GET request to a specific URL triggers the reboot of the Anybus gateway (or at least most of its modules). An attacker can use this feature to carry out a denial of service attack by continuously sending GET requests to that URL."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-26T20:50:23.197Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://sensepost.com/blog/2024/targeting-an-industrial-protocol-gateway/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-23766",
        "datePublished": "2024-06-26T00:00:00.000Z",
        "dateReserved": "2024-01-22T00:00:00.000Z",
        "dateUpdated": "2025-03-13T18:29:11.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…