CVE-2024-22439 (GCVE-0-2024-22439)
Vulnerability from cvelistv5 – Published: 2024-04-15 10:08 – Updated: 2024-08-01 22:43
VLAI
EPSS
VEX
Title
Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass
Summary
A potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Hewlett Packard Enterprise | HPE FlexNetwork and FlexFabric products |
Affected:
See security bulletin HPESBNW04625 for details
|
Date Public
2024-04-11 09:59
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22439",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-17T20:21:10.000927Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:46.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.952Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"platforms": [
"Custom"
],
"product": "HPE FlexNetwork and FlexFabric products",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "See security bulletin HPESBNW04625 for details"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)"
}
],
"datePublic": "2024-04-11T09:59:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\n\n"
}
],
"value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-15T10:08:57.234Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
}
],
"source": {
"advisory": "HPESBNW04625",
"discovery": "UNKNOWN"
},
"title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2024-22439",
"datePublished": "2024-04-15T10:08:57.234Z",
"dateReserved": "2024-01-10T15:24:39.967Z",
"dateUpdated": "2024-08-01T22:43:34.952Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-22439",
"date": "2026-07-12",
"epss": "0.002",
"percentile": "0.09998"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-22439\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2024-04-15T10:15:08.747\",\"lastModified\":\"2026-06-17T07:11:24.733\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una posible vulnerabilidad de seguridad en los productos de las series HPE FlexFabric y FlexNetwork. Esta vulnerabilidad podr\u00eda aprovecharse para obtener acceso privilegiado a conmutadores, lo que dar\u00eda como resultado la divulgaci\u00f3n de informaci\u00f3n.\"}],\"affected\":[{\"source\":\"security-alert@hpe.com\",\"affectedData\":[{\"vendor\":\"Hewlett Packard Enterprise\",\"product\":\"HPE FlexNetwork and FlexFabric products\",\"defaultStatus\":\"affected\",\"platforms\":[\"Custom\"],\"versions\":[{\"version\":\"See security bulletin HPESBNW04625 for details\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":4.7}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-04-17T20:21:10.000927Z\",\"id\":\"CVE-2024-22439\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-639\"}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\",\"source\":\"security-alert@hpe.com\"},{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"redhat_vex": {
"current_release_date": "2025-05-28T19:03:18+00:00",
"cve": "CVE-2024-22439",
"id": "CVE-2024-22439",
"initial_release_date": "2024-04-11T09:59:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-22439.json",
"version": "3"
},
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T22:43:34.952Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-22439\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-17T20:21:10.000927Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-23T19:01:23.838Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass\", \"source\": {\"advisory\": \"HPESBNW04625\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)\"}], \"impacts\": [{\"capecId\": \"CAPEC-233\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-233 Privilege Escalation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 6.9, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise\", \"product\": \"HPE FlexNetwork and FlexFabric products\", \"versions\": [{\"status\": \"affected\", \"version\": \"See security bulletin HPESBNW04625 for details\"}], \"platforms\": [\"Custom\"], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2024-04-11T09:59:00.000Z\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-639\", \"description\": \"CWE-639 Authorization Bypass Through User-Controlled Key\"}]}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2024-04-15T10:08:57.234Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-22439\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T22:43:34.952Z\", \"dateReserved\": \"2024-01-10T15:24:39.967Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2024-04-15T10:08:57.234Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…