Title
Hardcoded password in Eurosoft Przychodnia
Summary
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-10 13:42 UTC
CWE
  • CWE-259 - Use of Hard-coded Password
Assigner
CERT-PL CNA under the ENISA root
CNA scorecard B 81/100 over 221 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
EuroSoft Sp. z o. o. Eurosoft Przychodnia Affected: 0 , < 20240417.001 (custom)
guessed Create a notification for this product.
eurosoftsp.zo.o eurosoft_przychodina Affected: 0 , < 20240417.001 (custom)
    cpe:2.3:a:eurosoftsp.zo.o:eurosoft_przychodina:20240417.001:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-06-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:eurosoftsp.zo.o:eurosoft_przychodina:20240417.001:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "eurosoft_przychodina",
            "vendor": "eurosoftsp.zo.o",
            "versions": [
              {
                "lessThan": "20240417.001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1228",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T13:42:43.489051Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:21:10.928Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:33:25.114Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
          },
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
          },
          {
            "tags": [
              "product",
              "x_transferred"
            ],
            "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Eurosoft Przychodnia",
          "vendor": "EuroSoft Sp. z o. o.",
          "versions": [
            {
              "lessThan": "20240417.001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-06-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cp\u003eThis issue affects Eurosoft Przychodnia software before\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eversion\u003c/span\u003e\u0026nbsp;20240417.001 (from that version vulnerability is fixed).\u003c/p\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\n\nThis issue affects Eurosoft Przychodnia software before\u00a0version\u00a020240417.001 (from that version vulnerability is fixed)."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "RED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "CONCENTRATED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/AU:Y/R:U/V:C/RE:M/U:Red",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-03T09:00:16.189Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Hardcoded password in Eurosoft Przychodnia",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2024-1228",
    "datePublished": "2024-06-10T11:13:44.453Z",
    "dateReserved": "2024-02-05T13:46:45.179Z",
    "dateUpdated": "2025-10-07T13:21:10.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-1228",
      "date": "2026-10-15",
      "epss": "0.00409",
      "percentile": "0.33518"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Eurosoft Przychodnia",
                "vendor": "EuroSoft Sp. z o. o.",
                "versions": [
                  {
                    "lessThan": "20240417.001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cvd@cert.pl"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:eurosoftsp.zo.o:eurosoft_przychodina:20240417.001:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "eurosoft_przychodina",
                "vendor": "eurosoftsp.zo.o",
                "versions": [
                  {
                    "lessThan": "20240417.001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:eurosoft:przychodnia:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0EF7775C-026C-4F8E-8C72-0ECECF0AB425",
                    "versionEndExcluding": "20240417.001",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\n\nThis issue affects Eurosoft Przychodnia software before\u00a0version\u00a020240417.001 (from that version vulnerability is fixed)."
          },
          {
            "lang": "es",
            "value": "El uso de una contrase\u00f1a codificada para la base de datos de los pacientes permite a un atacante recuperar datos confidenciales almacenados en la base de datos. La contrase\u00f1a es la misma en todas las instalaciones de Eurosoft Przychodnia. Este problema afecta al software Eurosoft Przychodnia antes de la versi\u00f3n 20240417.001 (a partir de esa versi\u00f3n se soluciona la vulnerabilidad)."
          }
        ],
        "id": "CVE-2024-1228",
        "lastModified": "2026-06-17T07:03:45.677",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "source": "cvd@cert.pl",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-1228",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T13:42:43.489051Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-06-10T12:15:09.430",
        "references": [
          {
            "source": "cvd@cert.pl",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
          },
          {
            "source": "cvd@cert.pl",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
          },
          {
            "source": "cvd@cert.pl",
            "tags": [
              "Product"
            ],
            "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Product"
            ],
            "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
          }
        ],
        "sourceIdentifier": "cvd@cert.pl",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-259"
              }
            ],
            "source": "cvd@cert.pl",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-798"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-10-03T09:45:53+00:00",
      "cve": "CVE-2024-1228",
      "id": "CVE-2024-1228",
      "initial_release_date": "2024-06-10T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Hardcoded password in Eurosoft Przychodnia",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-1228.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:33:25.114Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "product",
                  "x_transferred"
                ],
                "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:eurosoftsp.zo.o:eurosoft_przychodina:20240417.001:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "eurosoft_przychodina",
                "vendor": "eurosoftsp.zo.o",
                "versions": [
                  {
                    "lessThan": "20240417.001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1228",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-10T13:42:43.489051Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-10T13:48:49.749Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Eurosoft Przychodnia",
              "vendor": "EuroSoft Sp. z o. o.",
              "versions": [
                {
                  "lessThan": "20240417.001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2024-06-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cp\u003eThis issue affects Eurosoft Przychodnia software before\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eversion\u003c/span\u003e\u0026nbsp;20240417.001 (from that version vulnerability is fixed).\u003c/p\u003e\u003c/div\u003e"
                }
              ],
              "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\n\nThis issue affects Eurosoft Przychodnia software before\u00a0version\u00a020240417.001 (from that version vulnerability is fixed)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/AU:Y/R:U/V:C/RE:M/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259 Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-03T09:00:16.189Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Hardcoded password in Eurosoft Przychodnia",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2024-1228",
        "datePublished": "2024-06-10T11:13:44.453Z",
        "dateReserved": "2024-02-05T13:46:45.179Z",
        "dateUpdated": "2025-10-07T13:21:10.928Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.