CVE-2023-5768 (GCVE-0-2023-5768)
Vulnerability from cvelistv5 – Published: 2023-12-04 14:33 – Updated: 2024-08-02 08:07| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hitachi Energy | RTU500 series |
Affected:
RTU500 series CMU Firmware version 12.0.1 – 12.0.14
Affected: RTU500 series CMU Firmware version 12.2.1 – 12.2.11 Affected: RTU500 series CMU Firmware version 12.4.1 – 12.4.11 Affected: RTU500 series CMU Firmware version 12.6.1 – 12.6.9 Affected: RTU500 series CMU Firmware version 12.7.1 – 12.7.6 Affected: RTU500 series CMU Firmware version 13.2.1 – 13.2.6 Affected: RTU500 series CMU Firmware version 13.4.1 – 13.4.3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:07:32.849Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.0.1 \u2013 12.0.14"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.2.1 \u2013 12.2.11"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.4.1 \u2013 12.4.11 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.6.1 \u2013 12.6.9 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.7.1 \u2013 12.7.6"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.2.1 \u2013 13.2.6 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.4.1 \u2013 13.4.3 "
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\u003cbr\u003e\u003cbr\u003eOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
],
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-04T14:35:49.612Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2023-5768",
"datePublished": "2023-12-04T14:33:47.898Z",
"dateReserved": "2023-10-25T15:24:39.183Z",
"dateUpdated": "2024-08-02T08:07:32.849Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-5768",
"date": "2026-04-24",
"epss": "0.0007",
"percentile": "0.21169"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-5768\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2023-12-04T15:15:07.793\",\"lastModified\":\"2024-11-21T08:42:27.003\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \\nIncomplete or wrong received APDU frame layout may \\ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \\nwith wrong length information of APDU or delayed reception \\nof data octets.\\n\\n\\nOnly communication link of affected HCI IEC 60870-5-104 \\nis blocked. If attack sequence stops the communication to \\nthe previously attacked link gets normal again.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad en HCI IEC 60870-5-104 que afecta a las versiones de productos RTU500 series que se enumeran a continuaci\u00f3n. El dise\u00f1o de la trama APDU recibida incompleta o incorrecta puede provocar el bloqueo en la capa de enlace. La raz\u00f3n del error fue un bloqueo interminable al leer tramas entrantes en la capa de enlace con informaci\u00f3n de longitud incorrecta de APDU o recepci\u00f3n retrasada de octetos de datos. Solo se bloquea el enlace de comunicaci\u00f3n del HCI IEC 60870-5-104 afectado. Si la secuencia del ataque se detiene, la comunicaci\u00f3n con el enlace previamente atacado vuelve a ser normal.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"2E81BEA6-121C-48D7-BAA9-91D652E6BC1A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"2469A78A-6F37-4F4B-BED8-060914B2D0A4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"E9E6934B-EBB2-45FB-8E4A-7D360CBA0F92\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"40D7C64F-54CC-4183-8420-011E2787541F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"BDD81EF6-9D45-4A2D-BFAA-D10005AEA046\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"8D5EFAE2-81D8-4E67-8515-137EAE453D6D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"DC740F55-F482-4BC2-9D39-D27F40EBB7C9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11AF93AD-200F-47A6-BA2C-F82165AFB50D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"D9F00BAD-06B1-49BE-BD41-61DE749E1506\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"79BC5D4A-09B2-41FB-962A-CF580181EB2C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"A30CDB2F-E0CC-4440-9E59-AB339F94996F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"D6BC4865-4064-421C-A746-8CB3D9DBAD7B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"5995FE68-15EA-4CB6-A43C-49582E4DF58C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"6E5803D1-164F-40E2-A348-21538EE1787F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"74AE224C-8D72-4C5A-ABB7-CE447E26992C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"BBD5E8FC-3FB5-4300-BBF4-DDAF573F20F2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"803838B5-058E-436B-8CE5-BF711456F96B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"A0361A98-1496-4763-A489-DCAE0D0DF613\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"7DECEA34-8A96-4943-B351-5080C4D34996\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"AF24A6B2-D9CF-44DE-A470-A09753D3A1B8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"2B890C79-2919-48F4-9431-3B92C48089C0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"90834F09-E09B-46BE-94BC-5812E63DE98D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6EEFDEF0-883D-402B-9CD4-333A145E3C75\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"8AC22007-6E39-4C5A-A392-139B43F819C0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"6BDB5A36-9B2F-43F9-A81B-506C4660151F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"F25FBFD5-BC45-49C9-87D4-A9C05405490D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"63096BB3-C0F9-4089-B11C-DE958B150DA8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"CC2029C0-3710-4CBB-8CBE-9EBA5793506A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"CDFF9898-F8FF-4361-A22C-DD5E47054FED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"18211DB4-DA86-4489-AFE1-48514160C1D4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"495DCBD6-D2D1-4295-81D1-6ACA1B2CA223\"}]}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true\",\"source\":\"cybersecurity@hitachienergy.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
FKIE_CVE-2023-5768
Vulnerability from fkie_nvd - Published: 2023-12-04 15:15 - Updated: 2024-11-21 08:426.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2E81BEA6-121C-48D7-BAA9-91D652E6BC1A",
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2469A78A-6F37-4F4B-BED8-060914B2D0A4",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E9E6934B-EBB2-45FB-8E4A-7D360CBA0F92",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40D7C64F-54CC-4183-8420-011E2787541F",
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDD81EF6-9D45-4A2D-BFAA-D10005AEA046",
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D5EFAE2-81D8-4E67-8515-137EAE453D6D",
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC740F55-F482-4BC2-9D39-D27F40EBB7C9",
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11AF93AD-200F-47A6-BA2C-F82165AFB50D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9F00BAD-06B1-49BE-BD41-61DE749E1506",
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "79BC5D4A-09B2-41FB-962A-CF580181EB2C",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A30CDB2F-E0CC-4440-9E59-AB339F94996F",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6BC4865-4064-421C-A746-8CB3D9DBAD7B",
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5995FE68-15EA-4CB6-A43C-49582E4DF58C",
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6E5803D1-164F-40E2-A348-21538EE1787F",
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74AE224C-8D72-4C5A-ABB7-CE447E26992C",
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BBD5E8FC-3FB5-4300-BBF4-DDAF573F20F2",
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "803838B5-058E-436B-8CE5-BF711456F96B",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A0361A98-1496-4763-A489-DCAE0D0DF613",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7DECEA34-8A96-4943-B351-5080C4D34996",
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF24A6B2-D9CF-44DE-A470-A09753D3A1B8",
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B890C79-2919-48F4-9431-3B92C48089C0",
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "90834F09-E09B-46BE-94BC-5812E63DE98D",
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6EEFDEF0-883D-402B-9CD4-333A145E3C75",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AC22007-6E39-4C5A-A392-139B43F819C0",
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6BDB5A36-9B2F-43F9-A81B-506C4660151F",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F25FBFD5-BC45-49C9-87D4-A9C05405490D",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63096BB3-C0F9-4089-B11C-DE958B150DA8",
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC2029C0-3710-4CBB-8CBE-9EBA5793506A",
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CDFF9898-F8FF-4361-A22C-DD5E47054FED",
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18211DB4-DA86-4489-AFE1-48514160C1D4",
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*",
"matchCriteriaId": "495DCBD6-D2D1-4295-81D1-6ACA1B2CA223",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en HCI IEC 60870-5-104 que afecta a las versiones de productos RTU500 series que se enumeran a continuaci\u00f3n. El dise\u00f1o de la trama APDU recibida incompleta o incorrecta puede provocar el bloqueo en la capa de enlace. La raz\u00f3n del error fue un bloqueo interminable al leer tramas entrantes en la capa de enlace con informaci\u00f3n de longitud incorrecta de APDU o recepci\u00f3n retrasada de octetos de datos. Solo se bloquea el enlace de comunicaci\u00f3n del HCI IEC 60870-5-104 afectado. Si la secuencia del ataque se detiene, la comunicaci\u00f3n con el enlace previamente atacado vuelve a ser normal."
}
],
"id": "CVE-2023-5768",
"lastModified": "2024-11-21T08:42:27.003",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-04T15:15:07.793",
"references": [
{
"source": "cybersecurity@hitachienergy.com",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-GV34-7CG2-7VFG
Vulnerability from github – Published: 2023-12-04 15:31 – Updated: 2023-12-04 15:31A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets.
Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
{
"affected": [],
"aliases": [
"CVE-2023-5768"
],
"database_specific": {
"cwe_ids": [
"CWE-79"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-12-04T15:15:07Z",
"severity": "MODERATE"
},
"details": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n",
"id": "GHSA-gv34-7cg2-7vfg",
"modified": "2023-12-04T15:31:55Z",
"published": "2023-12-04T15:31:55Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-5768"
},
{
"type": "WEB",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
VAR-202312-1763
Vulnerability from variot - Updated: 2025-02-14 23:09A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets.
Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. rtu520 firmware, rtu530 firmware, rtu540 firmware etc. Hitachi Energy A cross-site scripting vulnerability exists in the product.Information may be obtained and information may be tampered with. Hitachi Energy RTU500 is a series of industrial control components of Hitachi, Ltd
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1763",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.1"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.6"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.14"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.11"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.11"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.3"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.1"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.6"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.6"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.6"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.11"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.3"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.1"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.1"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.3"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.1"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.1"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.1"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.6"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.1"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.6"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.1"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.1"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.1"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.1"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.1"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.1"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.11"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.6"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.1"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.3"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.1"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.9"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.1"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.6"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.14"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.9"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.9"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.1"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.1"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.7.1"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.4.1"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.14"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.11"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.1"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.0.14"
},
{
"model": "rtu560",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.1"
},
{
"model": "rtu560",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.9"
},
{
"model": "rtu520",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.11"
},
{
"model": "rtu540",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.1"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.1"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "13.2.1"
},
{
"model": "rtu540",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.11"
},
{
"model": "rtu530",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.4.1"
},
{
"model": "rtu530",
"scope": "lte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.2.11"
},
{
"model": "rtu520",
"scope": "gte",
"trust": 1.0,
"vendor": "hitachienergy",
"version": "12.6.1"
},
{
"model": "rtu530",
"scope": null,
"trust": 0.8,
"vendor": "hitachi energy",
"version": null
},
{
"model": "rtu560",
"scope": null,
"trust": 0.8,
"vendor": "hitachi energy",
"version": null
},
{
"model": "rtu540",
"scope": null,
"trust": 0.8,
"vendor": "hitachi energy",
"version": null
},
{
"model": "rtu520",
"scope": null,
"trust": 0.8,
"vendor": "hitachi energy",
"version": null
},
{
"model": "energy rtu500 series cmu",
"scope": "gte",
"trust": 0.6,
"vendor": "hitachi",
"version": "12.0.1,\u003c=12.0.14"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"cve": "CVE-2023-5768",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 5.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 4.9,
"id": "CNVD-2025-02741",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2023-5768",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "cybersecurity@hitachienergy.com",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"id": "CVE-2023-5768",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2023-5768",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-5768",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "cybersecurity@hitachienergy.com",
"id": "CVE-2023-5768",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2023-5768",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-02741",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets. \n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again. rtu520 firmware, rtu530 firmware, rtu540 firmware etc. Hitachi Energy A cross-site scripting vulnerability exists in the product.Information may be obtained and information may be tampered with. Hitachi Energy RTU500 is a series of industrial control components of Hitachi, Ltd",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-5768"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "CNVD",
"id": "CNVD-2025-02741"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-5768",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-02741",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"id": "VAR-202312-1763",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
}
]
},
"last_update_date": "2025-02-14T23:09:05.536000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Hitachi Energy RTU500 series CMU Firmware Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/654831"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://publisher.hitachienergy.com/preview?documentid=8dbd000176\u0026languagecode=en\u0026preview=true"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-5768"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-02-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"date": "2024-01-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"date": "2023-12-04T15:15:07.793000",
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-02-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02741"
},
{
"date": "2024-01-11T07:50:00",
"db": "JVNDB",
"id": "JVNDB-2023-018634"
},
{
"date": "2023-12-07T21:02:40.177000",
"db": "NVD",
"id": "CVE-2023-5768"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Hitachi\u00a0Energy\u00a0 Cross-site scripting vulnerability in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-018634"
}
],
"trust": 0.8
}
}
BDU:2024-00034
Vulnerability from fstec - Published: 04.12.2023{
"CVSS 2.0": "AV:N/AC:H/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Hitachi, Ltd.",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u043e\u0442 12.6.1 \u0434\u043e 12.6.9 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 12.7.1 \u0434\u043e 12.7.6 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 13.2.1 \u0434\u043e 13.2.6 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 12.0.1 \u0434\u043e 12.0.14 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 12.2.1 \u0434\u043e 12.2.11 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 12.4.1 \u0434\u043e 12.4.11 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU), \u043e\u0442 13.4.1.0 \u0434\u043e 13.4.3.0 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (RTU500 series CMU)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0439 \u0438\u0437 \u0434\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432.\n\u0412 \u0441\u0432\u044f\u0437\u0438 \u0441\u043e \u0441\u043b\u043e\u0436\u0438\u0432\u0448\u0435\u0439\u0441\u044f \u043e\u0431\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u043e\u0439 \u0438 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u0430\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u043f\u0440\u043e\u0442\u0438\u0432 \u0420\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u043e\u0439 \u0424\u0435\u0434\u0435\u0440\u0430\u0446\u0438\u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u043e\u0441\u043b\u0435 \u043e\u0446\u0435\u043d\u043a\u0438 \u0432\u0441\u0435\u0445 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0440\u0438\u0441\u043a\u043e\u0432.\n\n\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0443\u0440\u043e\u0432\u043d\u044f \u0432\u0435\u0431-\u043f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN).\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f:\nhttps://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "04.12.2023",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "05.01.2024",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "05.01.2024",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2024-00034",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2023-5768",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "RTU500 series CMU",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u0430 APDU Frame Layout Handler \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u043e\u0432 Hitachi Energy RTU500 \u0441\u0435\u0440\u0438\u0438 CMU, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435 \u043c\u0435\u0440 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b \u0432\u0435\u0431-\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b (\u0438\u043b\u0438 \\\u00ab\u041c\u0435\u0436\u0441\u0430\u0439\u0442\u043e\u0432\u0430\u044f \u0441\u0446\u0435\u043d\u0430\u0440\u043d\u0430\u044f \u0430\u0442\u0430\u043a\u0430\\\u00bb) (CWE-79)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u043c\u043f\u043e\u043d\u0435\u043d\u0442\u0430 APDU Frame Layout Handler \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u043e\u0432 Hitachi Energy RTU500 \u0441\u0435\u0440\u0438\u0438 CMU \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0438\u043d\u044f\u0442\u0438\u0435\u043c \u043c\u0435\u0440 \u043f\u043e \u0437\u0430\u0449\u0438\u0442\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u044b \u0432\u0435\u0431-\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043f\u0443\u0442\u0451\u043c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u0444\u043e\u0440\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 APDU-\u043f\u0430\u043a\u0435\u0442\u043e\u0432",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u0418\u043d\u044a\u0435\u043a\u0446\u0438\u044f",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-79",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5,4)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5,9)"
}
WID-SEC-W-2023-3055
Vulnerability from csaf_certbund - Published: 2023-12-04 23:00 - Updated: 2023-12-04 23:00Es besteht eine Schwachstelle in Hitachi Energy RTU500. Dieser Fehler besteht in der HCI IEC 60870-5-104 aufgrund eines unvollständigen oder falschen Layouts der empfangenen APDU-Frames, was zu einer endlosen Blockierung beim Lesen eingehender Frames mit falschen Längeninformationen führt. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um einen Denial-of-Service-Zustand zu verursachen.
In Hitachi Energy RTU500 existiert eine Cross-Site Scripting Schwachstelle. HTML und Script-Eingaben werden in webserver nicht ordnungsgemäß überprüft, bevor sie an den Benutzer zurückgegeben werden. Ein entfernter, anonymer Angreifer kann durch Ausnutzung dieser Schwachstelle beliebigen HTML- und Script-Code durch den Browser des Benutzers im Kontext der betroffenen Seite ausführen.
In Hitachi Energy RTU500 existiert eine Cross-Site Scripting Schwachstelle. HTML und Script-Eingaben werden in webserver nicht ordnungsgemäß überprüft, bevor sie an den Benutzer zurückgegeben werden. Ein entfernter, anonymer Angreifer kann durch Ausnutzung dieser Schwachstelle beliebigen HTML- und Script-Code durch den Browser des Benutzers im Kontext der betroffenen Seite ausführen.
| URL | Category | |
|---|---|---|
{
"document": {
"aggregate_severity": {
"text": "mittel"
},
"category": "csaf_base",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "de-DE",
"notes": [
{
"category": "legal_disclaimer",
"text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen."
},
{
"category": "description",
"text": "Die RTU500-Serie ist eine Produktfamilie von Remote Terminal Units, die Informationen aus dem physikalischen Stromnetz in ein SCADA-System bringt.",
"title": "Produktbeschreibung"
},
{
"category": "summary",
"text": "Ein entfernter Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um einen Cross-Site-Scripting-Angriff zu starten oder einen Denial-of-Service-Zustand zu verursachen.",
"title": "Angriff"
},
{
"category": "general",
"text": "- BIOS/Firmware",
"title": "Betroffene Betriebssysteme"
}
],
"publisher": {
"category": "other",
"contact_details": "csaf-provider@cert-bund.de",
"name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"namespace": "https://www.bsi.bund.de"
},
"references": [
{
"category": "self",
"summary": "WID-SEC-W-2023-3055 - CSAF Version",
"url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-3055.json"
},
{
"category": "self",
"summary": "WID-SEC-2023-3055 - Portal Version",
"url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-3055"
},
{
"category": "external",
"summary": "GitHub Advisory Database vom 2023-12-04",
"url": "https://github.com/advisories/GHSA-gv34-7cg2-7vfg"
},
{
"category": "external",
"summary": "GitHub Advisory Database vom 2023-12-04",
"url": "https://github.com/advisories/GHSA-wr6r-5f4w-8399"
},
{
"category": "external",
"summary": "Hitachi Cybersecurity Advisory vom 2023-12-04",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"source_lang": "en-US",
"title": "Hitachi Energy RTU500: Mehrere Schwachstellen",
"tracking": {
"current_release_date": "2023-12-04T23:00:00.000+00:00",
"generator": {
"date": "2024-08-15T18:02:20.271+00:00",
"engine": {
"name": "BSI-WID",
"version": "1.3.5"
}
},
"id": "WID-SEC-W-2023-3055",
"initial_release_date": "2023-12-04T23:00:00.000+00:00",
"revision_history": [
{
"date": "2023-12-04T23:00:00.000+00:00",
"number": "1",
"summary": "Initiale Fassung"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 12.0.15",
"product": {
"name": "Hitachi Energy RTU500 \u003c 12.0.15",
"product_id": "T031450",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:12.0.15"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 12.2.12",
"product": {
"name": "Hitachi Energy RTU500 \u003c 12.2.12",
"product_id": "T031451",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:12.2.12"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 12.4.12",
"product": {
"name": "Hitachi Energy RTU500 \u003c 12.4.12",
"product_id": "T031452",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:12.4.12"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 12.6.10",
"product": {
"name": "Hitachi Energy RTU500 \u003c 12.6.10",
"product_id": "T031453",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:12.6.10"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 12.7.7",
"product": {
"name": "Hitachi Energy RTU500 \u003c 12.7.7",
"product_id": "T031454",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:12.7.7"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 13.2.7",
"product": {
"name": "Hitachi Energy RTU500 \u003c 13.2.7",
"product_id": "T031455",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:13.2.7"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 13.5.1",
"product": {
"name": "Hitachi Energy RTU500 \u003c 13.5.1",
"product_id": "T031456",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:13.5.1"
}
}
},
{
"category": "product_name",
"name": "Hitachi Energy RTU500 \u003c 13.4.4",
"product": {
"name": "Hitachi Energy RTU500 \u003c 13.4.4",
"product_id": "T031457",
"product_identification_helper": {
"cpe": "cpe:/h:abb:rtu500:13.4.4"
}
}
}
],
"category": "product_name",
"name": "RTU500"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-5769",
"notes": [
{
"category": "description",
"text": "Es besteht eine Schwachstelle in Hitachi Energy RTU500. Dieser Fehler besteht in der HCI IEC 60870-5-104 aufgrund eines unvollst\u00e4ndigen oder falschen Layouts der empfangenen APDU-Frames, was zu einer endlosen Blockierung beim Lesen eingehender Frames mit falschen L\u00e4ngeninformationen f\u00fchrt. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um einen Denial-of-Service-Zustand zu verursachen."
}
],
"release_date": "2023-12-04T23:00:00.000+00:00",
"title": "CVE-2023-5769"
},
{
"cve": "CVE-2023-5768",
"notes": [
{
"category": "description",
"text": "In Hitachi Energy RTU500 existiert eine Cross-Site Scripting Schwachstelle. HTML und Script-Eingaben werden in webserver nicht ordnungsgem\u00e4\u00df \u00fcberpr\u00fcft, bevor sie an den Benutzer zur\u00fcckgegeben werden. Ein entfernter, anonymer Angreifer kann durch Ausnutzung dieser Schwachstelle beliebigen HTML- und Script-Code durch den Browser des Benutzers im Kontext der betroffenen Seite ausf\u00fchren."
}
],
"release_date": "2023-12-04T23:00:00.000+00:00",
"title": "CVE-2023-5768"
},
{
"cve": "CVE-2023-5767",
"notes": [
{
"category": "description",
"text": "In Hitachi Energy RTU500 existiert eine Cross-Site Scripting Schwachstelle. HTML und Script-Eingaben werden in webserver nicht ordnungsgem\u00e4\u00df \u00fcberpr\u00fcft, bevor sie an den Benutzer zur\u00fcckgegeben werden. Ein entfernter, anonymer Angreifer kann durch Ausnutzung dieser Schwachstelle beliebigen HTML- und Script-Code durch den Browser des Benutzers im Kontext der betroffenen Seite ausf\u00fchren."
}
],
"release_date": "2023-12-04T23:00:00.000+00:00",
"title": "CVE-2023-5767"
}
]
}
GSD-2023-5768
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-5768",
"id": "GSD-2023-5768"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-5768"
],
"details": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n",
"id": "GSD-2023-5768",
"modified": "2023-12-13T01:20:50.544009Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@hitachienergy.com",
"ID": "CVE-2023-5768",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RTU500 series",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 12.0.1 \u2013 12.0.14"
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 12.2.1 \u2013 12.2.11"
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 12.4.1 \u2013 12.4.11 "
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 12.6.1 \u2013 12.6.9 "
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 12.7.1 \u2013 12.7.6"
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 13.2.1 \u2013 13.2.6 "
},
{
"version_affected": "=",
"version_value": "RTU500 series CMU Firmware version 13.4.1 \u2013 13.4.3 "
}
]
}
}
]
},
"vendor_name": "Hitachi Energy"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"refsource": "MISC",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.0.14",
"versionStartIncluding": "12.0.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.6.9",
"versionStartIncluding": "12.6.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.7.6",
"versionStartIncluding": "12.7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.2.6",
"versionStartIncluding": "13.2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.4.3",
"versionStartIncluding": "13.4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@hitachi-powergrids.com",
"ID": "CVE-2023-5768"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"refsource": "",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
},
"lastModifiedDate": "2023-12-07T21:02Z",
"publishedDate": "2023-12-04T15:15Z"
}
}
}
ICSA-25-128-02
Vulnerability from csaf_cisa - Published: 2023-11-28 13:30 - Updated: 2024-12-18 09:00A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi Energy PSIRT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/specification-document",
"text": "MEDIUM"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Hitachi Energy is aware of the vulnerabilities CVE-2023-5767, CVE-2023-5768 and CVE-2023-5769 in the Web server and HCI IEC 60870-5-104 component, that affects the RTU500 versions that are listed below. An at-\ntacker successfully exploiting these vulnerabilities could perform cross-site scripting on web server or denial of service on HCI IEC 60870-5-104. Please refer to the Recommended Immediate Actions for information about the available mitigation/remediation strategies.",
"title": "Summary"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warran-ties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software de-scribed in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.",
"title": "Notice"
},
{
"category": "general",
"text": "Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.",
"title": "General Mitigation Factors/Workarounds"
},
{
"category": "other",
"text": "For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.",
"title": "Support"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Hitachi Energy PSIRT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-128-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-128-02.json"
},
{
"category": "self",
"summary": "Cybersecurity Advisory - Multiple Vulnerabilities in Hitachi Energy\u2019s RTU500 series Product",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-128-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Hitachi Energy RTU500 series",
"tracking": {
"current_release_date": "2024-12-18T09:00:00.000000Z",
"generator": {
"date": "2025-05-08T16:28:02.864079Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-128-02",
"initial_release_date": "2023-11-28T13:30:00.000000Z",
"revision_history": [
{
"date": "2023-11-28T13:30:00.000000Z",
"number": "1",
"summary": "Initial version."
},
{
"date": "2023-12-13T11:00:00.000000Z",
"number": "2",
"summary": "Corrected CVE IDs"
},
{
"date": "2024-02-27T11:00:00.000000Z",
"number": "3",
"summary": "Updated fixed versions 13.2.7 and 13.4.4 for 13.2.x and 13.4.x series respectively under \u201cRecommended Actions\u201d"
},
{
"date": "2024-03-26T11:00:00.000000Z",
"number": "4",
"summary": "Updated fixed version 12.7.7 for 12.7.x series under \u201cRecommended Actions\u201d"
},
{
"date": "2024-10-01T10:00:00.000000Z",
"number": "5",
"summary": "Updated fixed versions 12.6.10 and 12.2.12 for 12.6.x and 12.2.x series respectively under \u201cRecommended Actions\u201d"
},
{
"date": "2024-12-18T09:00:00.000000Z",
"number": "6",
"summary": "Updated fixed versions 12.4.12 and 12.0.15 under \u201cRecommended Actions\u201d"
}
],
"status": "final",
"version": "6"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=12.0.1|\u003c=12.0.14",
"product": {
"name": "RTU500 series CMU Firmware version 12.0.1 \u2013 12.0.14",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version_range",
"name": "\u003e=12.2.1|\u003c=12.2.11",
"product": {
"name": "RTU500 series CMU Firmware version 12.2.1 \u2013 12.2.11",
"product_id": "CSAFPID-0002"
}
},
{
"category": "product_version_range",
"name": "\u003e=12.6.1|\u003c=12.6.9",
"product": {
"name": "RTU500 series CMU Firmware version 12.6.1 \u2013 12.6.9",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version_range",
"name": "\u003e=12.7.1|\u003c=12.7.6",
"product": {
"name": "RTU500 series CMU Firmware version 12.7.1 \u2013 12.7.6",
"product_id": "CSAFPID-0004"
}
},
{
"category": "product_version_range",
"name": "\u003e=13.2.1|\u003c=13.2.6",
"product": {
"name": "RTU500 series CMU Firmware version 13.2.1 \u2013 13.2.6",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version_range",
"name": "\u003e=13.4.1|\u003c=13.4.3",
"product": {
"name": "RTU500 series CMU Firmware version 13.4.1 \u2013 13.4.3",
"product_id": "CSAFPID-0006"
}
},
{
"category": "product_version",
"name": "12.0.15",
"product": {
"name": "RTU500 series CMU Firmware version 12.0.15",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "12.2.12",
"product": {
"name": "RTU500 series CMU Firmware version 12.2.12",
"product_id": "CSAFPID-0008"
}
},
{
"category": "product_version",
"name": "12.4.12",
"product": {
"name": "RTU500 series CMU Firmware version 12.4.12",
"product_id": "CSAFPID-0009"
}
},
{
"category": "product_version",
"name": "12.6.10",
"product": {
"name": "RTU500 series CMU Firmware version 12.6.10",
"product_id": "CSAFPID-0010"
}
},
{
"category": "product_version_range",
"name": "\u003e=12.4.1|\u003c=12.4.11",
"product": {
"name": "RTU500 series CMU Firmware version 12.4.1 \u2013 12.4.11 ",
"product_id": "CSAFPID-0011"
}
},
{
"category": "product_version",
"name": "12.7.7",
"product": {
"name": "RTU500 series CMU Firmware version 12.7.7",
"product_id": "CSAFPID-0012"
}
},
{
"category": "product_version",
"name": "13.2.7",
"product": {
"name": "RTU500 series CMU Firmware version 13.2.7",
"product_id": "CSAFPID-0013"
}
},
{
"category": "product_version",
"name": "13.4.4",
"product": {
"name": "RTU500 series CMU Firmware version 13.4.4",
"product_id": "CSAFPID-0014"
}
},
{
"category": "product_version",
"name": "13.5.1",
"product": {
"name": "RTU500 series CMU Firmware version 13.5.1",
"product_id": "CSAFPID-0015"
}
},
{
"category": "product_version_range",
"name": "\u003e=12.0.1|\u003c=13.4.3",
"product": {
"name": "RTU500 series CMU Firmware version 12.0.1 \u2013 13.4.3",
"product_id": "CSAFPID-0016"
}
}
],
"category": "product_name",
"name": "RTU500 series Product"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-5767",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.",
"title": "CVE description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "self",
"summary": "NVD - CVE-2023-5767",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-5767"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to the respective series fixed versions - 12.0.15, 12.2.12, 12.4.12, 12.6.10, 12.7.7, 13.2.7, 13.4.4 (or 13.5.1)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
},
{
"cve": "CVE-2023-5768",
"cwe": {
"id": "CWE-1285",
"name": "Improper Validation of Specified Index, Position, or Offset in Input"
},
"notes": [
{
"category": "description",
"text": "A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.",
"title": "CVE description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "self",
"summary": "NVD - CVE-2023-5768",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-5768"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to the respective series fixed versions - 12.0.15, 12.2.12, 12.4.12, 12.6.10, 12.7.7, 13.2.7, 13.4.4 (or 13.5.1)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.4,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.4,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
},
{
"cve": "CVE-2023-5769",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. \nOnly communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. ",
"title": "CVE description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "self",
"summary": "NVD - CVE-2023-5769",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-5769"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to the respective series fixed versions - 12.0.15, 12.2.12, 12.4.12, 12.6.10, 12.7.7, 13.2.7, 13.4.4 (or 13.5.1)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.9,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0011",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
}
]
}
CNVD-2025-02741
Vulnerability from cnvd - Published: 2025-02-13厂商已发布补丁修复漏洞,请广大用户及时下载更新: https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true
| Name | Hitachi Energy RTU500 series CMU Firmware >=12.0.1,<=12.0.14 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-5768",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2023-5768"
}
},
"description": "Hitachi Energy RTU500\u662f\u65e5\u672c\u65e5\u7acb\u5236\u4f5c\u6240\uff08Hitachi\uff09\u516c\u53f8\u7684\u4e00\u7cfb\u5217\u5de5\u63a7\u7ec4\u4ef6\u3002\n\nHitachi Energy RTU500 series CMU Firmware\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u63a5\u6536\u5230\u7684APDU\u5e27\u5e03\u5c40\u4e0d\u5b8c\u6574\u6216\u9519\u8bef\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u94fe\u8def\u5c42\u963b\u585e\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u8865\u4e01\u4fee\u590d\u6f0f\u6d1e\uff0c\u8bf7\u5e7f\u5927\u7528\u6237\u53ca\u65f6\u4e0b\u8f7d\u66f4\u65b0\uff1a\r\nhttps://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2025-02741",
"openTime": "2025-02-13",
"patchDescription": "Hitachi Energy RTU500\u662f\u65e5\u672c\u65e5\u7acb\u5236\u4f5c\u6240\uff08Hitachi\uff09\u516c\u53f8\u7684\u4e00\u7cfb\u5217\u5de5\u63a7\u7ec4\u4ef6\u3002\r\n\r\nHitachi Energy RTU500 series CMU Firmware\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u63a5\u6536\u5230\u7684APDU\u5e27\u5e03\u5c40\u4e0d\u5b8c\u6574\u6216\u9519\u8bef\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u94fe\u8def\u5c42\u963b\u585e\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Hitachi Energy RTU500 series CMU Firmware\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Hitachi Energy RTU500 series CMU Firmware \u003e=12.0.1\uff0c\u003c=12.0.14"
},
"referenceLink": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true",
"serverity": "\u4f4e",
"submitTime": "2023-12-11",
"title": "Hitachi Energy RTU500 series CMU Firmware\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.