Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-3776 (GCVE-0-2023-3776)
Vulnerability from cvelistv5 – Published: 2023-07-21 20:49 – Updated: 2025-03-05 18:48- CWE-416 - Use After Free
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:08:49.975Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"tags": [
"x_transferred"
],
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5492"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3776",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-05T18:36:21.985284Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-05T18:48:04.229Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "kernel",
"product": "Kernel",
"repo": "https://git.kernel.org",
"vendor": "Linux",
"versions": [
{
"lessThan": "6.5",
"status": "affected",
"version": "2.6",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Muhammad Alifa Ramdhan of STAR Labs SG"
}
],
"datePublic": "2023-07-07T02:10:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\u003c/p\u003e\u003cp\u003eIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\u003c/p\u003e\u003cp\u003eWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\u003c/p\u003e"
}
],
"value": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-02T14:06:25.968Z",
"orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"shortName": "Google"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"url": "https://www.debian.org/security/2023/dsa-5492"
},
{
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Use-after-free in Linux kernel\u0027s net/sched: cls_fw component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"assignerShortName": "Google",
"cveId": "CVE-2023-3776",
"datePublished": "2023-07-21T20:49:53.667Z",
"dateReserved": "2023-07-19T15:50:20.757Z",
"dateUpdated": "2025-03-05T18:48:04.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-3776",
"date": "2026-05-30",
"epss": "0.00042",
"percentile": "0.13253"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-3776\",\"sourceIdentifier\":\"cve-coordination@google.com\",\"published\":\"2023-07-21T21:15:11.973\",\"lastModified\":\"2025-02-13T17:16:58.960\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\\n\\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\\n\\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve-coordination@google.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cve-coordination@google.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.6.12\",\"versionEndExcluding\":\"4.14.322\",\"matchCriteriaId\":\"E7A8308C-F4B2-4261-B590-BCD968EF650E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.15\",\"versionEndExcluding\":\"4.19.291\",\"matchCriteriaId\":\"D2D2CA9F-4CC4-4AF5-8C6D-E58415AB782E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.20\",\"versionEndExcluding\":\"5.4.251\",\"matchCriteriaId\":\"7FA663C4-CA72-4B5A-8592-7354D978F58E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.5\",\"versionEndExcluding\":\"5.10.188\",\"matchCriteriaId\":\"43CAE50A-4A6C-488E-813C-F8DB77C13C8B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.11\",\"versionEndExcluding\":\"5.15.121\",\"matchCriteriaId\":\"EC77775B-EC31-4966-966C-1286C02B2A85\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.16\",\"versionEndExcluding\":\"6.1.40\",\"matchCriteriaId\":\"69315BCC-36D2-45CD-84F8-381EDF8E38F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.2\",\"versionEndExcluding\":\"6.4.5\",\"matchCriteriaId\":\"923F6AEA-C2EF-4B08-B038-69A18F3D41F8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:6.5:rc1:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B3E6E4D-E24E-4630-B00C-8C9901C597B0\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA6FEEC2-9F11-4643-8827-749718254FED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46D69DCC-AE4D-4EA5-861C-D60951444C6C\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Mailing List\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20240202-0003/\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5480\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5492\",\"source\":\"cve-coordination@google.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20240202-0003/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5480\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5492\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f\", \"tags\": [\"patch\", \"x_transferred\"]}, {\"url\": \"https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5480\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5492\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20240202-0003/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:08:49.975Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-3776\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-05T18:36:21.985284Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-05T18:36:24.013Z\"}}], \"cna\": {\"title\": \"Use-after-free in Linux kernel\u0027s net/sched: cls_fw component\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Muhammad Alifa Ramdhan of STAR Labs SG\"}], \"impacts\": [{\"capecId\": \"CAPEC-233\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-233 Privilege Escalation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"repo\": \"https://git.kernel.org\", \"vendor\": \"Linux\", \"product\": \"Kernel\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.6\", \"lessThan\": \"6.5\", \"versionType\": \"custom\"}], \"packageName\": \"kernel\", \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-07-07T02:10:00.000Z\", \"references\": [{\"url\": \"https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f\", \"tags\": [\"patch\"]}, {\"url\": \"https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f\"}, {\"url\": \"https://www.debian.org/security/2023/dsa-5480\"}, {\"url\": \"https://www.debian.org/security/2023/dsa-5492\"}, {\"url\": \"http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html\"}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html\"}, {\"url\": \"http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html\"}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html\"}, {\"url\": \"https://security.netapp.com/advisory/ntap-20240202-0003/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\\n\\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\\n\\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eA use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\u003c/p\u003e\u003cp\u003eIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\u003c/p\u003e\u003cp\u003eWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-416\", \"description\": \"CWE-416 Use After Free\"}]}], \"providerMetadata\": {\"orgId\": \"14ed7db2-1595-443d-9d34-6215bf890778\", \"shortName\": \"Google\", \"dateUpdated\": \"2024-02-02T14:06:25.968Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-3776\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-05T18:48:04.229Z\", \"dateReserved\": \"2023-07-19T15:50:20.757Z\", \"assignerOrgId\": \"14ed7db2-1595-443d-9d34-6215bf890778\", \"datePublished\": \"2023-07-21T20:49:53.667Z\", \"assignerShortName\": \"Google\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2024-AVI-0173
Vulnerability from certfr_avis - Published: 2024-02-29 - Updated: 2024-02-29
De multiples vulnérabilités ont été découvertes dans Juniper Secure Analytics . Certaines d'entre elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Juniper Networks | Secure Analytics | Juniper Secure Analytics versions antérieures à 7.5.0 UP7 IF05 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Juniper Secure Analytics versions ant\u00e9rieures \u00e0 7.5.0 UP7 IF05",
"product": {
"name": "Secure Analytics",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-43642",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43642"
},
{
"name": "CVE-2023-37920",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37920"
},
{
"name": "CVE-2023-20569",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20569"
},
{
"name": "CVE-2023-4206",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4206"
},
{
"name": "CVE-2023-3611",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3611"
},
{
"name": "CVE-2023-32360",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32360"
},
{
"name": "CVE-2022-43552",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43552"
},
{
"name": "CVE-2023-4207",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4207"
},
{
"name": "CVE-2023-20593",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20593"
},
{
"name": "CVE-2022-40982",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40982"
},
{
"name": "CVE-2023-4208",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4208"
},
{
"name": "CVE-2023-3776",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3776"
},
{
"name": "CVE-2023-44981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44981"
},
{
"name": "CVE-2023-5676",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5676"
}
],
"initial_release_date": "2024-02-29T00:00:00",
"last_revision_date": "2024-02-29T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0173",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-02-29T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Juniper Secure\nAnalytics . Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans Juniper Secure Analytics",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper du 29 f\u00e9vrier 2024",
"url": "https://supportportal.juniper.net/s/article/On-Demand-JSA-Series-Multiple-vulnerabilities-resolved-in-Juniper-Secure-Analytics-in-7-5-0-UP7-IF05?language=en_US"
}
]
}
CERTFR-2024-AVI-0332
Vulnerability from certfr_avis - Published: 2024-04-19 - Updated: 2024-04-19
De multiples vulnérabilités ont été découvertes dans les produits Red Hat. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - AUS 8.6 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 8.6 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Real Time for x86_64 - 4 years of updates 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - Extended Life Cycle Support (for IBM z Systems) 6 s390x | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 9.0 aarch64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Extended Update Support 8.6 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Power, little endian - Extended Update Support 8.6 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - TUS 8.6 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 9.0 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for ARM 64 - 4 years of updates 9.2 aarch64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 8.6 s390x | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for ARM 64 - 4 years of updates 9.0 aarch64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Real Time for x86_64 - 4 years of updates 9.0 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for ARM 64 - Extended Update Support 9.0 aarch64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 8.6 aarch64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Real Time for NFV for x86_64 - 4 years of updates 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 9.0 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Real Time for NFV for x86_64 - 4 years of updates 9.0 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 9.2 s390x | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 9.0 s390x | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Extended Update Support 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Extended Update Support 9.0 x86_64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 9.2 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for ARM 64 - Extended Update Support 9.2 aarch64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 9.2 aarch64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for IBM z Systems - 4 years of updates 9.0 s390x | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - Extended Life Cycle Support 6 i386 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 9.0 ppc64le | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 8.6 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - Extended Life Cycle Support 6 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - AUS 9.2 x86_64 | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Power, little endian - Extended Update Support 9.2 ppc64le | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for IBM z Systems - Extended Update Support 9.0 s390x | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for Power, little endian - Extended Update Support 9.0 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for ARM 64 - Extended Update Support 8.6 aarch64 | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for IBM z Systems - 4 years of updates 9.2 s390x | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server - Retired Extended Life Cycle Support 6 x86_64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 9.0 x86_64 | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 8.6 ppc64le | ||
| Red Hat | Red Hat CodeReady Linux Builder | Red Hat CodeReady Linux Builder for IBM z Systems - Extended Update Support 9.2 s390x | ||
| Red Hat | Red Hat Enterprise Linux Server | Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 9.2 ppc64le | ||
| Red Hat | Red Hat Enterprise Linux | Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 8.6 x86_64 | ||
| Red Hat | N/A | Red Hat Virtualization Host 4 for RHEL 8 x86_64 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Red Hat Enterprise Linux Server - AUS 8.6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 8.6 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Real Time for x86_64 - 4 years of updates 9.2 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - Extended Life Cycle Support (for IBM z Systems) 6 s390x",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 9.0 aarch64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Extended Update Support 8.6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Power, little endian - Extended Update Support 8.6 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - TUS 8.6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 9.0 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for ARM 64 - 4 years of updates 9.2 aarch64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 8.6 s390x",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for ARM 64 - 4 years of updates 9.0 aarch64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 9.2 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Real Time for x86_64 - 4 years of updates 9.0 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for ARM 64 - Extended Update Support 9.0 aarch64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 8.6 aarch64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 9.2 x86_64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Real Time for NFV for x86_64 - 4 years of updates 9.2 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 9.0 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Real Time for NFV for x86_64 - 4 years of updates 9.0 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 9.2 s390x",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for IBM z Systems - Extended Update Support 9.0 s390x",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Extended Update Support 9.2 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Extended Update Support 9.0 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 9.2 ppc64le",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for ARM 64 - Extended Update Support 9.2 aarch64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for ARM 64 - Extended Update Support 9.2 aarch64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for IBM z Systems - 4 years of updates 9.0 s390x",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - Extended Life Cycle Support 6 i386",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 9.0 ppc64le",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 8.6 x86_64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - Extended Life Cycle Support 6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - AUS 9.2 x86_64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Power, little endian - Extended Update Support 9.2 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for IBM z Systems - Extended Update Support 9.0 s390x",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for Power, little endian - Extended Update Support 9.0 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for ARM 64 - Extended Update Support 8.6 aarch64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for IBM z Systems - 4 years of updates 9.2 s390x",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server - Retired Extended Life Cycle Support 6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for x86_64 - Extended Update Support 9.0 x86_64",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for Power, little endian - Extended Update Support 8.6 ppc64le",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat CodeReady Linux Builder for IBM z Systems - Extended Update Support 9.2 s390x",
"product": {
"name": "Red Hat CodeReady Linux Builder",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux Server for Power LE - Update Services for SAP Solutions 9.2 ppc64le",
"product": {
"name": "Red Hat Enterprise Linux Server",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Enterprise Linux for x86_64 - Update Services for SAP Solutions 8.6 x86_64",
"product": {
"name": "Red Hat Enterprise Linux",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
},
{
"description": "Red Hat Virtualization Host 4 for RHEL 8 x86_64",
"product": {
"name": "N/A",
"vendor": {
"name": "Red Hat",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2024-26586",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26586"
},
{
"name": "CVE-2022-42895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42895"
},
{
"name": "CVE-2023-3611",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3611"
},
{
"name": "CVE-2023-31436",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-31436"
},
{
"name": "CVE-2023-4921",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4921"
},
{
"name": "CVE-2021-47099",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-47099"
},
{
"name": "CVE-2023-6240",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6240"
},
{
"name": "CVE-2022-1184",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1184"
},
{
"name": "CVE-2022-3640",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3640"
},
{
"name": "CVE-2024-26584",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26584"
},
{
"name": "CVE-2023-3776",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3776"
},
{
"name": "CVE-2021-26341",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26341"
},
{
"name": "CVE-2021-33631",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33631"
},
{
"name": "CVE-2022-1852",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1852"
},
{
"name": "CVE-2024-26582",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26582"
},
{
"name": "CVE-2023-6931",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6931"
}
],
"initial_release_date": "2024-04-19T00:00:00",
"last_revision_date": "2024-04-19T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0332",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-04-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Red Hat\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire,\nun d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des\ndonn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Red Hat",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1840 du 16 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1840"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1831 du 16 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1831"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1836 du 16 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1836"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1877 du 18 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1877"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1882 du 18 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1882"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Red Hat RHSA-2024:1881 du 18 avril 2024",
"url": "https://access.redhat.com/errata/RHSA-2024:1881"
}
]
}
CERTFR-2024-AVI-0575
Vulnerability from certfr_avis - Published: 2024-07-12 - Updated: 2024-10-15
De multiples vulnérabilités ont été découvertes dans les produits Juniper Networks. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Juniper Networks | N/A | Junos OS versions 23.4 antérieures à 23.4R2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 21.4-EVO antérieures à 21.4R2-EVO | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 22.4 antérieures à 22.4R3 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 22.2 antérieures à 22.2R3-S3 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 22.1-EVO antérieures à 22.1R3-S6-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 22.4 antérieures à 22.4R3-S2 | ||
| Juniper Networks | N/A | Junos OS versions 23.2 antérieures à 23.2R2-S1 | ||
| Juniper Networks | N/A | Session Smart Router versions 6.2 antérieures à SSR-6.2.5-r2 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 22.1 antérieures à 22.1R3-S5 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 22.4-EVO antérieures à 22.4R3-S2-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 23.2-EVO antérieures à 23.2R2-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 21.4 antérieures à 21.4R3-S7 | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 21.2 antérieures à 21.2R3-S8 | ||
| Juniper Networks | N/A | Junos OS versions 22.1 antérieures à 22.1R3-S6 | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.3 antérieures à 22.3R3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 21.3-EVO antérieures à 21.3R3-S5-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions 21.2-EVO antérieures à 21.2R3-S7-EVO | ||
| Juniper Networks | N/A | Junos OS versions antérieures à 20.4R3-S9 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 23.4-EVO antérieures à 23.4R2-EVO | ||
| Juniper Networks | N/A | Junos OS versions 22.4 antérieures à 22.4R2-S2 | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 22.2 antérieures à 22.2R3-S4 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 21.4 antérieures à 21.4R3-S6 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 22.4 antérieures à 22.4R3 | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 22.3 antérieures à 22.3R3-S2 | ||
| Juniper Networks | N/A | Session Smart Router versions 6.1 antérieures à SSR-6.1.8-lts | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.4-EVO antérieures à 22.4R3-EVO | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 20.4 antérieures à 20.4R3-S10 | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 antérieures à 22.4R3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 24.2-EVO antérieures à 24.2R2-EVO | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.4 antérieures à 22.4R3 | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.2 antérieures à 22.2R3-S1 | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.3 antérieures à 21.3R3-S5 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 23.2 antérieures à 23.2R2 | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 22.3 antérieures à 22.3R3-S2 | ||
| Juniper Networks | N/A | Junos OS versions 21.4 antérieures à 21.4R2 | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 22.2 antérieures à 22.2R3-S3 | ||
| Juniper Networks | N/A | Junos OS versions 23.4 antérieures à 23.4R1-S2 | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.2 antérieures à 22.2R3-S2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.3-EVO antérieures à 22.3R3-S3-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 23.2R1-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 21.4R3-S8-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 22.1 antérieures à 22.1R3-S6 | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.2 antérieures à 21.2R3-S6 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions antérieures à 21.2R3-S6 | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 22.2 antérieures à 22.2R3-S3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 23.2-EVO antérieures à 23.2R1-S1-EVO | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 23.2 antérieures à 23.2R2 | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 23.2 antérieures à 23.2R2 | ||
| Juniper Networks | N/A | Junos OS versions antérieures à 21.4R3-S8 | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 22.4R3-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 23.4 antérieures à 23.4R1-S1 | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions antérieures à 21.2R3-S7 | ||
| Juniper Networks | N/A | Session Smart Router versions antérieures à SSR-5.6.14 | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 23.2 antérieures à 23.2R2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 21.2R3-S8-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions antérieures à 21.2R3-S8 | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.1 antérieures à 22.1R3-S2 | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.3 antérieures à 22.3R3-S1 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions antérieures à 21.4R3-S7-EVO | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 22.1 antérieures à 22.1R3-S5 | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 21.4 antérieures à 21.4R3-S6 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 22.3-EVO antérieures à 22.3R3-S3-EVO | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 23.4 antérieures à 23.4R2 | ||
| Juniper Networks | N/A | Junos OS versions 22.3 antérieures à 22.3R1-S2 | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 22.3 antérieures à 22.3R3-S3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.3-EVO antérieures à 22.3R1-S1-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.4-EVO antérieures à 22.4R3-S3-EVO | ||
| Juniper Networks | N/A | Junos OS versions antérieures à 21.2R3-S8 | ||
| Juniper Networks | N/A | Junos Space versions antérieures à 24.1R1 | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.4 antérieures à 21.4R3-S6 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.3-EVO antérieures à 22.3R2-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions 23.4-EVO antérieures à 23.4R2-EVO | ||
| Juniper Networks | N/A | Junos OS versions 22.4 antérieures à 22.4R3-S3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 20.4R3-S10-EVO | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 22.4 antérieures à 22.4R3-S1 | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 antérieures à 22.4R1-S2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.4-EVO antérieures à 22.4R2-S2-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions antérieures à 21.2R3-S8-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 antérieures à 22.4R2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 23.2-EVO antérieures à 23.2R2-S1-EVO | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 22.1 antérieures à 22.1R3-S5 | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à before 22.1R3-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.3 antérieures à 22.3R2-S1 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 21.4-EVO antérieures à 21.4R3-S8-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 22.2-EVO antérieures à 22.2R3-S4-EVO | ||
| Juniper Networks | N/A | SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.1 antérieures à 22.1R3-S4 | ||
| Juniper Networks | N/A | Junos OS versions 21.3 antérieures à 21.3R3-S5 | ||
| Juniper Networks | N/A | Junos OS versions antérieures à 22.1R2-S2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.1-EVO antérieures à 22.1R3-S6-EVO | ||
| Juniper Networks | N/A | Junos OS versions 22.2 antérieures à 22.2R3-S4 | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 21.4 antérieures à 21.4R3-S7 | ||
| Juniper Networks | N/A | Junos OS Evolved on ACX7000 Series versions 23.4-EVO antérieures à 23.4R1-S2-EVO | ||
| Juniper Networks | N/A | Junos OS Evolved versions antérieures à 22.4R2-EVO | ||
| Juniper Networks | N/A | Junos OS on MX Series with SPC3 line card versions 23.2 antérieures à 23.2R2 | ||
| Juniper Networks | N/A | Junos OS versions 22.2 antérieures à 22.2R2-S1 | ||
| Juniper Networks | N/A | Junos OS versions 23.1 antérieures à 23.1R2 | ||
| Juniper Networks | N/A | Junos OS on MX Series versions 22.3 antérieures à 22.3R3-S2 | ||
| Juniper Networks | N/A | Junos OS versions 22.3 antérieures à 22.3R3-S3 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.2-EVO antérieures à 22.2R3-S4-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions antérieures à 21.2R3-S8 | ||
| Juniper Networks | N/A | Junos OS versions 22.3 antérieures à 22.3R2-S2 | ||
| Juniper Networks | N/A | Junos OS on QFX5000 Series and EX4600 Series versions 21.4 antérieures à 21.4R3-S6 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 22.2-EVO antérieures à 22.2R2-S1-EVO | ||
| Juniper Networks | N/A | Junos OS on SRX4600 and SRX5000 Series versions 23.4 antérieures à 23.4R2 | ||
| Juniper Networks | N/A | Junos OS Evolved versions 23.4-EVO antérieures à 23.4R1-S2-EVO |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Junos OS versions 23.4 ant\u00e9rieures \u00e0 23.4R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 21.4-EVO ant\u00e9rieures \u00e0 21.4R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 22.4 ant\u00e9rieures \u00e0 22.4R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 22.1-EVO ant\u00e9rieures \u00e0 22.1R3-S6-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 22.4 ant\u00e9rieures \u00e0 22.4R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 23.2 ant\u00e9rieures \u00e0 23.2R2-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Session Smart Router versions 6.2 ant\u00e9rieures \u00e0 SSR-6.2.5-r2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 22.4-EVO ant\u00e9rieures \u00e0 22.4R3-S2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 23.2-EVO ant\u00e9rieures \u00e0 23.2R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S7",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 21.2 ant\u00e9rieures \u00e0 21.2R3-S8",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.3 ant\u00e9rieures \u00e0 22.3R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 21.3-EVO ant\u00e9rieures \u00e0 21.3R3-S5-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 21.2-EVO ant\u00e9rieures \u00e0 21.2R3-S7-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions ant\u00e9rieures \u00e0 20.4R3-S9",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 23.4-EVO ant\u00e9rieures \u00e0 23.4R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.4 ant\u00e9rieures \u00e0 22.4R2-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S4",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 22.4 ant\u00e9rieures \u00e0 22.4R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Session Smart Router versions 6.1 ant\u00e9rieures \u00e0 SSR-6.1.8-lts",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.4-EVO ant\u00e9rieures \u00e0 22.4R3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 20.4 ant\u00e9rieures \u00e0 20.4R3-S10",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 ant\u00e9rieures \u00e0 22.4R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 24.2-EVO ant\u00e9rieures \u00e0 24.2R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.4 ant\u00e9rieures \u00e0 22.4R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.3 ant\u00e9rieures \u00e0 21.3R3-S5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 23.2 ant\u00e9rieures \u00e0 23.2R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 21.4 ant\u00e9rieures \u00e0 21.4R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 23.4 ant\u00e9rieures \u00e0 23.4R1-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.3-EVO ant\u00e9rieures \u00e0 22.3R3-S3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 23.2R1-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 21.4R3-S8-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.2 ant\u00e9rieures \u00e0 21.2R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions ant\u00e9rieures \u00e0 21.2R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.2-EVO ant\u00e9rieures \u00e0 23.2R1-S1-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 23.2 ant\u00e9rieures \u00e0 23.2R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 23.2 ant\u00e9rieures \u00e0 23.2R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions ant\u00e9rieures \u00e0 21.4R3-S8",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 22.4R3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 23.4 ant\u00e9rieures \u00e0 23.4R1-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions ant\u00e9rieures \u00e0 21.2R3-S7",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Session Smart Router versions ant\u00e9rieures \u00e0 SSR-5.6.14",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 23.2 ant\u00e9rieures \u00e0 23.2R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 21.2R3-S8-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions ant\u00e9rieures \u00e0 21.2R3-S8",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions ant\u00e9rieures \u00e0 21.4R3-S7-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 22.3-EVO ant\u00e9rieures \u00e0 22.3R3-S3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 23.4 ant\u00e9rieures \u00e0 23.4R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.3 ant\u00e9rieures \u00e0 22.3R1-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.3-EVO ant\u00e9rieures \u00e0 22.3R1-S1-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.4-EVO ant\u00e9rieures \u00e0 22.4R3-S3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions ant\u00e9rieures \u00e0 21.2R3-S8",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos Space versions ant\u00e9rieures \u00e0 24.1R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.3-EVO ant\u00e9rieures \u00e0 22.3R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.4-EVO ant\u00e9rieures \u00e0 23.4R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.4 ant\u00e9rieures \u00e0 22.4R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 20.4R3-S10-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 22.4 ant\u00e9rieures \u00e0 22.4R3-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 ant\u00e9rieures \u00e0 22.4R1-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.4-EVO ant\u00e9rieures \u00e0 22.4R2-S2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions ant\u00e9rieures \u00e0 21.2R3-S8-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.4 ant\u00e9rieures \u00e0 22.4R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.2-EVO ant\u00e9rieures \u00e0 23.2R2-S1-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 before 22.1R3-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX Series, MX Series with SPC3 and NFX350 versions 22.3 ant\u00e9rieures \u00e0 22.3R2-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 21.4-EVO ant\u00e9rieures \u00e0 21.4R3-S8-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 22.2-EVO ant\u00e9rieures \u00e0 22.2R3-S4-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "SRX Series and MX Series with SPC3 and MS-MPC/MIC versions 22.1 ant\u00e9rieures \u00e0 22.1R3-S4",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 21.3 ant\u00e9rieures \u00e0 21.3R3-S5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions ant\u00e9rieures \u00e0 22.1R2-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.1-EVO ant\u00e9rieures \u00e0 22.1R3-S6-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.2 ant\u00e9rieures \u00e0 22.2R3-S4",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S7",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved on ACX7000 Series versions 23.4-EVO ant\u00e9rieures \u00e0 23.4R1-S2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 22.4R2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series with SPC3 line card versions 23.2 ant\u00e9rieures \u00e0 23.2R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.2 ant\u00e9rieures \u00e0 22.2R2-S1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 23.1 ant\u00e9rieures \u00e0 23.1R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on MX Series versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.3 ant\u00e9rieures \u00e0 22.3R3-S3",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.2-EVO ant\u00e9rieures \u00e0 22.2R3-S4-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions ant\u00e9rieures \u00e0 21.2R3-S8",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 22.3 ant\u00e9rieures \u00e0 22.3R2-S2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on QFX5000 Series and EX4600 Series versions 21.4 ant\u00e9rieures \u00e0 21.4R3-S6",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 22.2-EVO ant\u00e9rieures \u00e0 22.2R2-S1-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS on SRX4600 and SRX5000 Series versions 23.4 ant\u00e9rieures \u00e0 23.4R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.4-EVO ant\u00e9rieures \u00e0 23.4R1-S2-EVO",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-39560",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39560"
},
{
"name": "CVE-2023-32435",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32435"
},
{
"name": "CVE-2021-44906",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44906"
},
{
"name": "CVE-2024-20919",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20919"
},
{
"name": "CVE-2024-39554",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39554"
},
{
"name": "CVE-2023-21843",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21843"
},
{
"name": "CVE-2024-39539",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39539"
},
{
"name": "CVE-2021-36160",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-36160"
},
{
"name": "CVE-2020-12401",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12401"
},
{
"name": "CVE-2024-39558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39558"
},
{
"name": "CVE-2022-30522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30522"
},
{
"name": "CVE-2021-37701",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37701"
},
{
"name": "CVE-2022-21460",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21460"
},
{
"name": "CVE-2021-31535",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31535"
},
{
"name": "CVE-2022-36760",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36760"
},
{
"name": "CVE-2021-33034",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33034"
},
{
"name": "CVE-2024-20926",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20926"
},
{
"name": "CVE-2024-39552",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39552"
},
{
"name": "CVE-2021-27290",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27290"
},
{
"name": "CVE-2019-11727",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-11727"
},
{
"name": "CVE-2023-3390",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3390"
},
{
"name": "CVE-2023-4004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4004"
},
{
"name": "CVE-2021-29469",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29469"
},
{
"name": "CVE-2023-2002",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2002"
},
{
"name": "CVE-2023-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21830"
},
{
"name": "CVE-2022-22823",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22823"
},
{
"name": "CVE-2021-23440",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23440"
},
{
"name": "CVE-2021-32804",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32804"
},
{
"name": "CVE-2020-13950",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13950"
},
{
"name": "CVE-2021-26691",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26691"
},
{
"name": "CVE-2024-39546",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39546"
},
{
"name": "CVE-2024-39540",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39540"
},
{
"name": "CVE-2018-3737",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3737"
},
{
"name": "CVE-2024-39543",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39543"
},
{
"name": "CVE-2020-11984",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11984"
},
{
"name": "CVE-2022-22721",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22721"
},
{
"name": "CVE-2021-35624",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-35624"
},
{
"name": "CVE-2023-35788",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35788"
},
{
"name": "CVE-2023-32067",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32067"
},
{
"name": "CVE-2024-39514",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39514"
},
{
"name": "CVE-2022-25147",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25147"
},
{
"name": "CVE-2021-35604",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-35604"
},
{
"name": "CVE-2021-42013",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42013"
},
{
"name": "CVE-2023-34059",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34059"
},
{
"name": "CVE-2024-39529",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39529"
},
{
"name": "CVE-2006-20001",
"url": "https://www.cve.org/CVERecord?id=CVE-2006-20001"
},
{
"name": "CVE-2024-20921",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20921"
},
{
"name": "CVE-2021-2385",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2385"
},
{
"name": "CVE-2022-29167",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29167"
},
{
"name": "CVE-2020-7774",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7774"
},
{
"name": "CVE-2019-10747",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10747"
},
{
"name": "CVE-2023-34058",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34058"
},
{
"name": "CVE-2011-5094",
"url": "https://www.cve.org/CVERecord?id=CVE-2011-5094"
},
{
"name": "CVE-2019-16776",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16776"
},
{
"name": "CVE-2022-21589",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21589"
},
{
"name": "CVE-2022-25315",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25315"
},
{
"name": "CVE-2019-10097",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10097"
},
{
"name": "CVE-2022-22822",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22822"
},
{
"name": "CVE-2023-2828",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2828"
},
{
"name": "CVE-2023-22081",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22081"
},
{
"name": "CVE-2023-4206",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4206"
},
{
"name": "CVE-2022-21304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21304"
},
{
"name": "CVE-2023-3090",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3090"
},
{
"name": "CVE-2024-39536",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39536"
},
{
"name": "CVE-2024-39555",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39555"
},
{
"name": "CVE-2022-3564",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3564"
},
{
"name": "CVE-2023-3611",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3611"
},
{
"name": "CVE-2020-13938",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13938"
},
{
"name": "CVE-2016-10540",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-10540"
},
{
"name": "CVE-2019-10082",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10082"
},
{
"name": "CVE-2023-42753",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-42753"
},
{
"name": "CVE-2016-1000232",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1000232"
},
{
"name": "CVE-2015-9262",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-9262"
},
{
"name": "CVE-2023-32360",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32360"
},
{
"name": "CVE-2021-37713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37713"
},
{
"name": "CVE-2021-39275",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39275"
},
{
"name": "CVE-2024-39561",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39561"
},
{
"name": "CVE-2022-21303",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21303"
},
{
"name": "CVE-2019-17023",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17023"
},
{
"name": "CVE-2016-4658",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-4658"
},
{
"name": "CVE-2020-35452",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35452"
},
{
"name": "CVE-2023-4207",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4207"
},
{
"name": "CVE-2022-21617",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21617"
},
{
"name": "CVE-2023-0767",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0767"
},
{
"name": "CVE-2022-41741",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41741"
},
{
"name": "CVE-2023-22067",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22067"
},
{
"name": "CVE-2021-37712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37712"
},
{
"name": "CVE-2022-23852",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23852"
},
{
"name": "CVE-2023-30630",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30630"
},
{
"name": "CVE-2022-21608",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21608"
},
{
"name": "CVE-2022-2526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2526"
},
{
"name": "CVE-2023-20593",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20593"
},
{
"name": "CVE-2024-39535",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39535"
},
{
"name": "CVE-2024-39545",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39545"
},
{
"name": "CVE-2024-39531",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39531"
},
{
"name": "CVE-2022-41742",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41742"
},
{
"name": "CVE-2019-16777",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16777"
},
{
"name": "CVE-2021-2389",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2389"
},
{
"name": "CVE-2023-21840",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21840"
},
{
"name": "CVE-2019-10081",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10081"
},
{
"name": "CVE-2020-1934",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-1934"
},
{
"name": "CVE-2022-30556",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30556"
},
{
"name": "CVE-2020-8648",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8648"
},
{
"name": "CVE-2022-21270",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21270"
},
{
"name": "CVE-2023-21963",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21963"
},
{
"name": "CVE-2022-25235",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25235"
},
{
"name": "CVE-2023-21980",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21980"
},
{
"name": "CVE-2024-39530",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39530"
},
{
"name": "CVE-2024-39532",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39532"
},
{
"name": "CVE-2023-27522",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27522"
},
{
"name": "CVE-2024-39557",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39557"
},
{
"name": "CVE-2021-2390",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2390"
},
{
"name": "CVE-2024-39550",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39550"
},
{
"name": "CVE-2022-28615",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28615"
},
{
"name": "CVE-2022-21451",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21451"
},
{
"name": "CVE-2014-10064",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-10064"
},
{
"name": "CVE-2024-39511",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39511"
},
{
"name": "CVE-2022-23943",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23943"
},
{
"name": "CVE-2024-39548",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39548"
},
{
"name": "CVE-2020-11993",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11993"
},
{
"name": "CVE-2023-22652",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22652"
},
{
"name": "CVE-2024-39528",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39528"
},
{
"name": "CVE-2023-3341",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3341"
},
{
"name": "CVE-2023-22025",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22025"
},
{
"name": "CVE-2021-43527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-43527"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2024-39559",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39559"
},
{
"name": "CVE-2014-7191",
"url": "https://www.cve.org/CVERecord?id=CVE-2014-7191"
},
{
"name": "CVE-2021-2356",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2356"
},
{
"name": "CVE-2020-36049",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36049"
},
{
"name": "CVE-2023-4208",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4208"
},
{
"name": "CVE-2021-41524",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41524"
},
{
"name": "CVE-2022-3517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3517"
},
{
"name": "CVE-2020-12402",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12402"
},
{
"name": "CVE-2019-11719",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-11719"
},
{
"name": "CVE-2021-34798",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34798"
},
{
"name": "CVE-2024-39519",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39519"
},
{
"name": "CVE-2021-32803",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32803"
},
{
"name": "CVE-2019-17006",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17006"
},
{
"name": "CVE-2022-21595",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21595"
},
{
"name": "CVE-2019-16775",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16775"
},
{
"name": "CVE-2020-12403",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12403"
},
{
"name": "CVE-2023-3776",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3776"
},
{
"name": "CVE-2023-2700",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2700"
},
{
"name": "CVE-2020-7754",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7754"
},
{
"name": "CVE-2024-39533",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39533"
},
{
"name": "CVE-2021-22543",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22543"
},
{
"name": "CVE-2021-33909",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33909"
},
{
"name": "CVE-2021-26690",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26690"
},
{
"name": "CVE-2022-22719",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22719"
},
{
"name": "CVE-2022-40674",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40674"
},
{
"name": "CVE-2022-46663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46663"
},
{
"name": "CVE-2011-1473",
"url": "https://www.cve.org/CVERecord?id=CVE-2011-1473"
},
{
"name": "CVE-2024-39513",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39513"
},
{
"name": "CVE-2021-3803",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3803"
},
{
"name": "CVE-2022-21417",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21417"
},
{
"name": "CVE-2024-39518",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39518"
},
{
"name": "CVE-2023-37450",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37450"
},
{
"name": "CVE-2021-30641",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30641"
},
{
"name": "CVE-2021-3177",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3177"
},
{
"name": "CVE-2020-7660",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7660"
},
{
"name": "CVE-2022-31813",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31813"
},
{
"name": "CVE-2023-34969",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34969"
},
{
"name": "CVE-2019-9517",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9517"
},
{
"name": "CVE-2018-20834",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20834"
},
{
"name": "CVE-2020-12362",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12362"
},
{
"name": "CVE-2020-1927",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-1927"
},
{
"name": "CVE-2022-21592",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21592"
},
{
"name": "CVE-2021-3347",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3347"
},
{
"name": "CVE-2022-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25236"
},
{
"name": "CVE-2023-25690",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25690"
},
{
"name": "CVE-2021-2342",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2342"
},
{
"name": "CVE-2022-22720",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22720"
},
{
"name": "CVE-2017-15010",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-15010"
},
{
"name": "CVE-2019-10092",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10092"
},
{
"name": "CVE-2024-39541",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39541"
},
{
"name": "CVE-2021-44224",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44224"
},
{
"name": "CVE-2024-39537",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39537"
},
{
"name": "CVE-2022-21444",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21444"
},
{
"name": "CVE-2019-17567",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17567"
},
{
"name": "CVE-2018-7408",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7408"
},
{
"name": "CVE-2019-20149",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20149"
},
{
"name": "CVE-2024-20932",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20932"
},
{
"name": "CVE-2023-35001",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35001"
},
{
"name": "CVE-2024-39551",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39551"
},
{
"name": "CVE-2023-4863",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4863"
},
{
"name": "CVE-2022-29404",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29404"
},
{
"name": "CVE-2020-14145",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14145"
},
{
"name": "CVE-2019-11756",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-11756"
},
{
"name": "CVE-2024-20918",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20918"
},
{
"name": "CVE-2024-39565",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39565"
},
{
"name": "CVE-2021-31618",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31618"
},
{
"name": "CVE-2022-21344",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21344"
},
{
"name": "CVE-2023-24329",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24329"
},
{
"name": "CVE-2024-39549",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39549"
},
{
"name": "CVE-2022-21367",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21367"
},
{
"name": "CVE-2021-33193",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33193"
},
{
"name": "CVE-2021-41773",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41773"
},
{
"name": "CVE-2020-11668",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11668"
},
{
"name": "CVE-2022-26377",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26377"
},
{
"name": "CVE-2021-44790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44790"
},
{
"name": "CVE-2020-9490",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9490"
},
{
"name": "CVE-2020-28502",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28502"
},
{
"name": "CVE-2024-39556",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39556"
},
{
"name": "CVE-2022-37436",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37436"
},
{
"name": "CVE-2021-33033",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33033"
},
{
"name": "CVE-2023-32439",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32439"
},
{
"name": "CVE-2020-12400",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12400"
},
{
"name": "CVE-2023-21912",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21912"
},
{
"name": "CVE-2022-28330",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28330"
},
{
"name": "CVE-2024-39542",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39542"
},
{
"name": "CVE-2022-21454",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21454"
},
{
"name": "CVE-2017-1000048",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-1000048"
},
{
"name": "CVE-2022-21427",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21427"
},
{
"name": "CVE-2021-40438",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40438"
},
{
"name": "CVE-2024-20945",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20945"
},
{
"name": "CVE-2022-22824",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22824"
},
{
"name": "CVE-2020-6829",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6829"
},
{
"name": "CVE-2021-2372",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-2372"
},
{
"name": "CVE-2022-21245",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21245"
},
{
"name": "CVE-2020-28469",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28469"
},
{
"name": "CVE-2024-20952",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20952"
},
{
"name": "CVE-2019-10098",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10098"
},
{
"name": "CVE-2024-39538",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39538"
},
{
"name": "CVE-2022-28614",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28614"
}
],
"initial_release_date": "2024-07-12T00:00:00",
"last_revision_date": "2024-10-15T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0575",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-07-12T00:00:00.000000"
},
{
"description": "Correction d\u0027identifiants CVE erron\u00e9s",
"revision_date": "2024-10-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Juniper Networks. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Juniper Networks",
"vendor_advisories": [
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83001",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Inconsistent-information-in-the-TE-database-can-lead-to-an-rpd-crash-CVE-2024-39541"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82976",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-The-802-1X-Authentication-Daemon-crashes-on-running-a-specific-command-CVE-2024-39511"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83027",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Session-Smart-Router-Multiple-vulnerabilities-resolved"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83021",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX4600-SRX5000-Series-TCP-packets-with-SYN-FIN-or-SYN-RST-are-transferred-after-enabling-no-syn-check-with-Express-Path-CVE-2024-39561"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83018",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Receipt-of-specific-PIM-packet-causes-rpd-crash-when-PIM-is-configured-along-with-MoFRR-CVE-2024-39558"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82987",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-RPD-crashes-upon-concurrent-deletion-of-a-routing-instance-and-receipt-of-an-SNMP-request-CVE-2024-39528"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82982",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-MX240-MX480-MX960-platforms-using-MPC10E-Memory-leak-will-be-observed-when-subscribed-to-a-specific-subscription-on-Junos-Telemetry-Interface-CVE-2024-39518"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83012",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-MX-Series-with-SPC3-line-card-Port-flaps-causes-rtlogd-memory-leak-leading-to-Denial-of-Service-CVE-2024-39550"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83019",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-Receipt-of-a-specific-TCP-packet-may-result-in-a-system-crash-vmcore-on-dual-RE-systems-with-NSR-enabled-CVE-2024-39559"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83004",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Receipt-of-a-large-RPKI-RTR-PDU-packet-can-cause-rpd-to-crash-CVE-2024-39543"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83010",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-Receipt-of-specific-packets-in-the-aftmand-process-will-lead-to-a-memory-leak-CVE-2024-39548"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83014",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-BGP-multipath-incremental-calculation-is-resulting-in-an-rpd-crash-CVE-2024-39554"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82996",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Flaps-of-BFD-sessions-with-authentication-cause-a-ppmd-memory-leak-CVE-2024-39536"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82980",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Receiving-specific-traffic-on-devices-with-EVPN-VPWS-with-IGMP-snooping-enabled-will-cause-the-rpd-to-crash-CVE-2024-39514"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83000",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX-Series-and-MX-Series-with-SPC3-Specific-valid-TCP-traffic-can-cause-a-pfe-crash-CVE-2024-39540"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83008",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-Local-low-privilege-user-can-gain-root-permissions-leading-to-privilege-escalation-CVE-2024-39546"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82991",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-ACX7000-Series-Protocol-specific-DDoS-configuration-affects-other-protocols-CVE-2024-39531"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83011",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Receipt-of-malformed-BGP-path-attributes-leads-to-a-memory-leak-CVE-2024-39549"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82989",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Attempting-to-access-specific-sensors-on-platforms-not-supporting-these-will-lead-to-a-chassisd-crash-CVE-2024-39530"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82997",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-ACX7000-Series-Ports-which-have-been-inadvertently-exposed-can-be-reached-over-the-network-CVE-2024-39537"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83023",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX-Series-EX-Series-J-Web-An-unauthenticated-network-based-attacker-can-perform-XPATH-injection-attack-against-a-device-CVE-2024-39565"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83026",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-Space-Multiple-vulnerabilities-resolved-in-24-1R1-release"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83013",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX-Series-and-MX-Series-with-SPC3-and-MS-MPC-MIC-Receipt-of-specific-packets-in-H-323-ALG-causes-traffic-drop-CVE-2024-39551"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83002",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-A-malformed-CFM-packet-or-specific-transit-traffic-leads-to-FPC-crash-CVE-2024-39542"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83015",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Receipt-of-a-specific-malformed-BGP-update-causes-the-session-to-reset-CVE-2024-39555"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83007",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX-Series-and-MX-Series-with-SPC3-and-NFX350-When-VPN-tunnels-parameters-are-not-matching-the-iked-process-will-crash-CVE-2024-39545"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82995",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-ACX7000-Series-When-specific-traffic-is-received-in-a-VPLS-scenario-evo-pfemand-crashes-CVE-2024-39535"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82993",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-QFX5000-Series-and-EX4600-Series-Output-firewall-filter-is-not-applied-if-certain-match-criteria-are-used-CVE-2024-39533"
},
{
"published_at": "2024-07-11",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA75726",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Malformed-BGP-UPDATE-causes-RPD-crash-CVE-2024-39552"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82988",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-SRX-Series-If-DNS-traceoptions-are-configured-in-a-DGA-or-tunnel-detection-scenario-specific-DNS-traffic-leads-to-a-PFE-crash-CVE-2024-39529"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83017",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-MAC-table-changes-cause-a-memory-leak-CVE-2024-39557"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82983",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-ACX-7000-Series-Multicast-traffic-is-looped-in-a-multihoming-EVPN-MPLS-scenario-CVE-2024-39519"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83020",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Memory-leak-due-to-RSVP-neighbor-persistent-error-leading-to-kernel-crash-CVE-2024-39560"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82998",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-ACX7000-Series-When-multicast-traffic-with-a-specific-S-G-is-received-evo-pfemand-crashes-CVE-2024-39538"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82999",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-MX-Series-Continuous-subscriber-logins-will-lead-to-a-memory-leak-and-eventually-an-FPC-crash-CVE-2024-39539"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA83016",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Loading-a-malicious-certificate-from-the-CLI-may-result-in-a-stack-based-overflow-CVE-2024-39556"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82992",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Confidential-information-in-logs-can-be-accessed-by-another-user-CVE-2024-39532"
},
{
"published_at": "2024-07-10",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA82978",
"url": "https://supportportal.juniper.net/s/article/2024-07-Security-Bulletin-Junos-OS-Evolved-Execution-of-a-specific-CLI-command-will-cause-a-crash-in-the-AFT-manager-CVE-2024-39513"
}
]
}
CERTFR-2025-AVI-0855
Vulnerability from certfr_avis - Published: 2025-10-09 - Updated: 2025-10-09
De multiples vulnérabilités ont été découvertes dans les produits Juniper Networks. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Juniper Networks | Junos OS | Junos OS versions 24.4 antérieures à 24.4R2 | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved versions antérieures à 22.4R3-S8-EVO | ||
| Juniper Networks | Junos OS | Junos OS versions 23.4 antérieures à 23.4R2-S5 | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved versions 23.2-EVO antérieures à 23.2R2-S4-EVO | ||
| Juniper Networks | Junos OS | Junos OS versions antérieures à 22.4R3-S8 | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved versions 24.2-EVO antérieures à 24.2R2-S2-EVO | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved versions 24.4-EVO antérieures à 24.4R2-EVO | ||
| Juniper Networks | Junos Space | Junos Space versions antérieures à 24.1R4 | ||
| Juniper Networks | Security Director | Security Director Policy Enforcer versions antérieures à 23.1R1 Hotpatch v3 | ||
| Juniper Networks | Junos Space | Junos Space Security Director versions antérieures à 24.1R4 | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved versions 23.4-EVO antérieures à 23.4R2-S5-EVO | ||
| Juniper Networks | Junos OS | Junos OS versions 23.2 antérieures à 23.2R2-S4 | ||
| Juniper Networks | Junos OS | Junos OS versions 24.2 antérieures à 24.2R2-S1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Junos OS versions 24.4 ant\u00e9rieures \u00e0 24.4R2",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions ant\u00e9rieures \u00e0 22.4R3-S8-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 23.4 ant\u00e9rieures \u00e0 23.4R2-S5",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.2-EVO ant\u00e9rieures \u00e0 23.2R2-S4-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions ant\u00e9rieures \u00e0 22.4R3-S8",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 24.2-EVO ant\u00e9rieures \u00e0 24.2R2-S2-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 24.4-EVO ant\u00e9rieures \u00e0 24.4R2-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos Space versions ant\u00e9rieures \u00e0 24.1R4",
"product": {
"name": "Junos Space",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Security Director Policy Enforcer versions ant\u00e9rieures \u00e0 23.1R1 Hotpatch v3",
"product": {
"name": "Security Director",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos Space Security Director versions ant\u00e9rieures \u00e0 24.1R4",
"product": {
"name": "Junos Space",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved versions 23.4-EVO ant\u00e9rieures \u00e0 23.4R2-S5-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 23.2 ant\u00e9rieures \u00e0 23.2R2-S4",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS versions 24.2 ant\u00e9rieures \u00e0 24.2R2-S1",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-24795",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24795"
},
{
"name": "CVE-2024-36903",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36903"
},
{
"name": "CVE-2023-44431",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44431"
},
{
"name": "CVE-2021-47606",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-47606"
},
{
"name": "CVE-2025-59993",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59993"
},
{
"name": "CVE-2025-59997",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59997"
},
{
"name": "CVE-2023-7104",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-7104"
},
{
"name": "CVE-2025-59995",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59995"
},
{
"name": "CVE-2024-21235",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21235"
},
{
"name": "CVE-2023-28466",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28466"
},
{
"name": "CVE-2024-36921",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36921"
},
{
"name": "CVE-2025-59986",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59986"
},
{
"name": "CVE-2025-60009",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60009"
},
{
"name": "CVE-2025-59989",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59989"
},
{
"name": "CVE-2024-26897",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26897"
},
{
"name": "CVE-2023-46103",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46103"
},
{
"name": "CVE-2024-27052",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27052"
},
{
"name": "CVE-2023-2235",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2235"
},
{
"name": "CVE-2025-59999",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59999"
},
{
"name": "CVE-2025-59994",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59994"
},
{
"name": "CVE-2024-4076",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-4076"
},
{
"name": "CVE-2025-59967",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59967"
},
{
"name": "CVE-2022-24805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24805"
},
{
"name": "CVE-2024-12797",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12797"
},
{
"name": "CVE-2023-3390",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3390"
},
{
"name": "CVE-2024-37356",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37356"
},
{
"name": "CVE-2024-47538",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-47538"
},
{
"name": "CVE-2023-4004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4004"
},
{
"name": "CVE-2024-21823",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21823"
},
{
"name": "CVE-2025-59991",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59991"
},
{
"name": "CVE-2024-5564",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5564"
},
{
"name": "CVE-2024-26600",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26600"
},
{
"name": "CVE-2023-28746",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28746"
},
{
"name": "CVE-2023-52864",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-52864"
},
{
"name": "CVE-2025-26600",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26600"
},
{
"name": "CVE-2024-3596",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"name": "CVE-2024-27280",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27280"
},
{
"name": "CVE-2024-36929",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36929"
},
{
"name": "CVE-2023-35788",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35788"
},
{
"name": "CVE-2025-59982",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59982"
},
{
"name": "CVE-2024-1975",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-1975"
},
{
"name": "CVE-2023-43785",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43785"
},
{
"name": "CVE-2024-30205",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-30205"
},
{
"name": "CVE-2018-17247",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-17247"
},
{
"name": "CVE-2025-60004",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60004"
},
{
"name": "CVE-2023-51594",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51594"
},
{
"name": "CVE-2024-22025",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-22025"
},
{
"name": "CVE-2023-50229",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-50229"
},
{
"name": "CVE-2025-59974",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59974"
},
{
"name": "CVE-2025-26598",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26598"
},
{
"name": "CVE-2018-3824",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3824"
},
{
"name": "CVE-2024-40928",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-40928"
},
{
"name": "CVE-2024-43398",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-43398"
},
{
"name": "CVE-2024-8508",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8508"
},
{
"name": "CVE-2024-36020",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36020"
},
{
"name": "CVE-2021-45105",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-45105"
},
{
"name": "CVE-2025-59981",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59981"
},
{
"name": "CVE-2023-31248",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-31248"
},
{
"name": "CVE-2024-1737",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-1737"
},
{
"name": "CVE-2023-25193",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25193"
},
{
"name": "CVE-2021-4104",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4104"
},
{
"name": "CVE-2024-30203",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-30203"
},
{
"name": "CVE-2023-3090",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3090"
},
{
"name": "CVE-2024-35937",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35937"
},
{
"name": "CVE-2025-59968",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59968"
},
{
"name": "CVE-2023-51592",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51592"
},
{
"name": "CVE-2025-59990",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59990"
},
{
"name": "CVE-2021-22146",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22146"
},
{
"name": "CVE-2025-59978",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59978"
},
{
"name": "CVE-2024-25629",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-25629"
},
{
"name": "CVE-2024-36017",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36017"
},
{
"name": "CVE-2024-24806",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24806"
},
{
"name": "CVE-2024-27434",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27434"
},
{
"name": "CVE-2023-47038",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-47038"
},
{
"name": "CVE-2024-35852",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35852"
},
{
"name": "CVE-2024-38558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-38558"
},
{
"name": "CVE-2025-59992",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59992"
},
{
"name": "CVE-2024-35845",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35845"
},
{
"name": "CVE-2021-41072",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41072"
},
{
"name": "CVE-2025-60000",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60000"
},
{
"name": "CVE-2022-24807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24807"
},
{
"name": "CVE-2024-47607",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-47607"
},
{
"name": "CVE-2024-27065",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27065"
},
{
"name": "CVE-2024-36005",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36005"
},
{
"name": "CVE-2023-45866",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45866"
},
{
"name": "CVE-2023-27349",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27349"
},
{
"name": "CVE-2023-0464",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0464"
},
{
"name": "CVE-2015-5377",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-5377"
},
{
"name": "CVE-2023-48161",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-48161"
},
{
"name": "CVE-2022-24810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24810"
},
{
"name": "CVE-2024-33621",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33621"
},
{
"name": "CVE-2024-27983",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27983"
},
{
"name": "CVE-2025-60001",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60001"
},
{
"name": "CVE-2024-5742",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5742"
},
{
"name": "CVE-2023-50230",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-50230"
},
{
"name": "CVE-2025-52960",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-52960"
},
{
"name": "CVE-2024-36922",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36922"
},
{
"name": "CVE-2025-59996",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59996"
},
{
"name": "CVE-2024-39487",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39487"
},
{
"name": "CVE-2024-27982",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27982"
},
{
"name": "CVE-2023-38575",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38575"
},
{
"name": "CVE-2024-35911",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35911"
},
{
"name": "CVE-2025-59957",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59957"
},
{
"name": "CVE-2025-59958",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59958"
},
{
"name": "CVE-2021-41043",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41043"
},
{
"name": "CVE-2018-17244",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-17244"
},
{
"name": "CVE-2019-12900",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12900"
},
{
"name": "CVE-2024-39908",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39908"
},
{
"name": "CVE-2025-26597",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26597"
},
{
"name": "CVE-2024-36971",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36971"
},
{
"name": "CVE-2023-2603",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2603"
},
{
"name": "CVE-2024-41946",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-41946"
},
{
"name": "CVE-2023-3776",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3776"
},
{
"name": "CVE-2024-42934",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-42934"
},
{
"name": "CVE-2023-51580",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51580"
},
{
"name": "CVE-2024-35848",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35848"
},
{
"name": "CVE-2024-27417",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27417"
},
{
"name": "CVE-2023-21102",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21102"
},
{
"name": "CVE-2024-27281",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27281"
},
{
"name": "CVE-2025-59983",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59983"
},
{
"name": "CVE-2024-36941",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36941"
},
{
"name": "CVE-2024-2236",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2236"
},
{
"name": "CVE-2024-38428",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-38428"
},
{
"name": "CVE-2024-35969",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35969"
},
{
"name": "CVE-2021-45046",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-45046"
},
{
"name": "CVE-2025-60006",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60006"
},
{
"name": "CVE-2024-36489",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36489"
},
{
"name": "CVE-2015-1427",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-1427"
},
{
"name": "CVE-2024-38575",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-38575"
},
{
"name": "CVE-2024-35899",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35899"
},
{
"name": "CVE-2024-35823",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35823"
},
{
"name": "CVE-2024-40954",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-40954"
},
{
"name": "CVE-2024-9632",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9632"
},
{
"name": "CVE-2023-38408",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38408"
},
{
"name": "CVE-2025-26595",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26595"
},
{
"name": "CVE-2024-26868",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26868"
},
{
"name": "CVE-2023-43787",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43787"
},
{
"name": "CVE-2023-43786",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43786"
},
{
"name": "CVE-2024-8235",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8235"
},
{
"name": "CVE-2023-4147",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4147"
},
{
"name": "CVE-2025-59977",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59977"
},
{
"name": "CVE-2023-6004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6004"
},
{
"name": "CVE-2023-3610",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3610"
},
{
"name": "CVE-2025-26596",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26596"
},
{
"name": "CVE-2024-4603",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-4603"
},
{
"name": "CVE-2022-48622",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48622"
},
{
"name": "CVE-2021-42550",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42550"
},
{
"name": "CVE-2021-44228",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
},
{
"name": "CVE-2024-26828",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26828"
},
{
"name": "CVE-2025-59998",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59998"
},
{
"name": "CVE-2024-26808",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26808"
},
{
"name": "CVE-2024-30204",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-30204"
},
{
"name": "CVE-2025-60002",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60002"
},
{
"name": "CVE-2023-35001",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35001"
},
{
"name": "CVE-2024-27282",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27282"
},
{
"name": "CVE-2018-3831",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3831"
},
{
"name": "CVE-2023-43490",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43490"
},
{
"name": "CVE-2025-59976",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59976"
},
{
"name": "CVE-2025-59980",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59980"
},
{
"name": "CVE-2025-26599",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26599"
},
{
"name": "CVE-2024-47615",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-47615"
},
{
"name": "CVE-2018-3823",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3823"
},
{
"name": "CVE-2023-22655",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22655"
},
{
"name": "CVE-2024-6126",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6126"
},
{
"name": "CVE-2023-4911",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4911"
},
{
"name": "CVE-2023-39368",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39368"
},
{
"name": "CVE-2021-44832",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44832"
},
{
"name": "CVE-2024-26853",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26853"
},
{
"name": "CVE-2025-59975",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59975"
},
{
"name": "CVE-2025-0624",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-0624"
},
{
"name": "CVE-2025-59987",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59987"
},
{
"name": "CVE-2024-40958",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-40958"
},
{
"name": "CVE-2018-3826",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3826"
},
{
"name": "CVE-2025-26601",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26601"
},
{
"name": "CVE-2024-52337",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-52337"
},
{
"name": "CVE-2025-59985",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59985"
},
{
"name": "CVE-2025-11198",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-11198"
},
{
"name": "CVE-2022-24806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24806"
},
{
"name": "CVE-2023-32233",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32233"
},
{
"name": "CVE-2024-35789",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35789"
},
{
"name": "CVE-2024-26327",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26327"
},
{
"name": "CVE-2015-3253",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-3253"
},
{
"name": "CVE-2025-59964",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59964"
},
{
"name": "CVE-2025-59988",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59988"
},
{
"name": "CVE-2024-21210",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21210"
},
{
"name": "CVE-2024-2511",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2511"
},
{
"name": "CVE-2024-34397",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-34397"
},
{
"name": "CVE-2023-45733",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45733"
},
{
"name": "CVE-2021-40153",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40153"
},
{
"name": "CVE-2024-6655",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6655"
},
{
"name": "CVE-2024-41123",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-41123"
},
{
"name": "CVE-2024-27049",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-27049"
},
{
"name": "CVE-2025-59984",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59984"
},
{
"name": "CVE-2025-52961",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-52961"
},
{
"name": "CVE-2023-51589",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51589"
},
{
"name": "CVE-2024-21217",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21217"
},
{
"name": "CVE-2024-28182",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28182"
},
{
"name": "CVE-2021-3903",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3903"
},
{
"name": "CVE-2024-35800",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35800"
},
{
"name": "CVE-2023-2124",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2124"
},
{
"name": "CVE-2023-51596",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51596"
},
{
"name": "CVE-2025-60010",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-60010"
},
{
"name": "CVE-2023-51764",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51764"
},
{
"name": "CVE-2025-26594",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-26594"
},
{
"name": "CVE-2024-6409",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6409"
},
{
"name": "CVE-2024-49761",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-49761"
},
{
"name": "CVE-2022-24808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24808"
},
{
"name": "CVE-2025-59962",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-59962"
},
{
"name": "CVE-2024-21208",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21208"
},
{
"name": "CVE-2020-11023",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11023"
},
{
"name": "CVE-2024-40961",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-40961"
}
],
"initial_release_date": "2025-10-09T00:00:00",
"last_revision_date": "2025-10-09T00:00:00",
"links": [],
"reference": "CERTFR-2025-AVI-0855",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-10-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Juniper Networks. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Juniper Networks",
"vendor_advisories": [
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103140",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Multiple-XSS-vulnerabilities-resolved-in-24-1R4-release"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103141",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Multiple-vulnerabilities-resolved-in-24-1R4-release"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103163",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-Evolved-Multiple-OS-command-injection-vulnerabilities-fixed-CVE-2025-60006"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103168",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Device-allows-login-for-user-with-expired-password-CVE-2025-60010"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103171",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Reflected-client-side-HTTP-parameter-pollution-vulnerability-in-web-interface-CVE-2025-59977"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103167",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-When-a-user-with-the-name-ftp-or-anonymous-is-configured-unauthenticated-filesystem-access-is-allowed-CVE-2025-59980"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103156",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-Evolved-ACX7024-ACX7024X-ACX7100-32C-ACX7100-48L-ACX7348-ACX7509-When-specific-valid-multicast-traffic-is-received-on-the-L3-interface-a-vulnerable-device-evo-pfemand-crashes-and-restarts-CVE-2025-59967"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103437",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Security-Director-Policy-Enforcer-An-unrestricted-API-allows-a-network-based-unauthenticated-attacker-to-deploy-malicious-vSRX-images-to-VMWare-NSX-Server-CVE-2025-11198"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103172",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Flooding-device-with-inbound-API-calls-leads-to-WebUI-and-CLI-management-access-DoS-CVE-2025-59975"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103157",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Juniper-Security-Director-Insufficient-authorization-for-sensitive-resources-in-web-interface-CVE-2025-59968"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103170",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Arbitrary-file-download-vulnerability-in-web-interface-CVE-2025-59976"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103139",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Security-Director-Multiple-vulnerabilities-resolved-in-24-1R4"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103151",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-With-BGP-sharding-enabled-change-in-indirect-next-hop-can-cause-RPD-crash-CVE-2025-59962"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103153",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-SRX4700-When-forwarding-options-sampling-is-enabled-any-traffic-destined-to-the-RE-will-cause-the-forwarding-line-card-to-crash-and-restart-CVE-2025-59964"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103147",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-Evolved-PTX-Series-When-firewall-filter-rejects-traffic-these-packets-are-erroneously-sent-to-the-RE-CVE-2025-59958"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103144",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-Evolved-PTX-Series-except-PTX10003-An-unauthenticated-adjacent-attacker-sending-specific-valid-traffic-can-cause-a-memory-leak-in-cfmman-leading-to-FPC-crash-and-restart-CVE-2025-52961"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103143",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-SRX-Series-and-MX-Series-Receipt-of-specific-SIP-packets-in-a-high-utilization-situation-causes-a-flowd-crash-CVE-2025-52960"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103146",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-EX4600-Series-and-QFX5000-Series-An-attacker-with-physical-access-can-open-a-persistent-backdoor-CVE-2025-59957"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103138",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-Space-Security-Director-Multiple-vulnerabilities-resolved-in-24-1R4-by-upgrading-Log4j-Java-library-to-2-23-1-and-ElasticSearch-to-6-8-17"
},
{
"published_at": "2025-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Juniper Networks JSA103165",
"url": "https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-Specific-BGP-EVPN-update-message-causes-rpd-crash-CVE-2025-60004"
}
]
}
FKIE_CVE-2023-3776
Vulnerability from fkie_nvd - Published: 2023-07-21 21:15 - Updated: 2025-02-13 17:167.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
| URL | Tags | ||
|---|---|---|---|
| cve-coordination@google.com | http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html | Third Party Advisory, VDB Entry | |
| cve-coordination@google.com | http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html | Third Party Advisory, VDB Entry | |
| cve-coordination@google.com | https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f | Mailing List, Patch, Vendor Advisory | |
| cve-coordination@google.com | https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f | Patch, Vendor Advisory | |
| cve-coordination@google.com | https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html | Mailing List, Third Party Advisory | |
| cve-coordination@google.com | https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html | Mailing List, Third Party Advisory | |
| cve-coordination@google.com | https://security.netapp.com/advisory/ntap-20240202-0003/ | Third Party Advisory | |
| cve-coordination@google.com | https://www.debian.org/security/2023/dsa-5480 | Third Party Advisory | |
| cve-coordination@google.com | https://www.debian.org/security/2023/dsa-5492 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f | Mailing List, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20240202-0003/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.debian.org/security/2023/dsa-5480 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.debian.org/security/2023/dsa-5492 | Third Party Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | * | |
| linux | linux_kernel | 6.5 | |
| debian | debian_linux | 10.0 | |
| debian | debian_linux | 11.0 | |
| debian | debian_linux | 12.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E7A8308C-F4B2-4261-B590-BCD968EF650E",
"versionEndExcluding": "4.14.322",
"versionStartIncluding": "2.6.12",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2D2CA9F-4CC4-4AF5-8C6D-E58415AB782E",
"versionEndExcluding": "4.19.291",
"versionStartIncluding": "4.15",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7FA663C4-CA72-4B5A-8592-7354D978F58E",
"versionEndExcluding": "5.4.251",
"versionStartIncluding": "4.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43CAE50A-4A6C-488E-813C-F8DB77C13C8B",
"versionEndExcluding": "5.10.188",
"versionStartIncluding": "5.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC77775B-EC31-4966-966C-1286C02B2A85",
"versionEndExcluding": "5.15.121",
"versionStartIncluding": "5.11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "69315BCC-36D2-45CD-84F8-381EDF8E38F3",
"versionEndExcluding": "6.1.40",
"versionStartIncluding": "5.16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "923F6AEA-C2EF-4B08-B038-69A18F3D41F8",
"versionEndExcluding": "6.4.5",
"versionStartIncluding": "6.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:6.5:rc1:*:*:*:*:*:*",
"matchCriteriaId": "0B3E6E4D-E24E-4630-B00C-8C9901C597B0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
"matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FA6FEEC2-9F11-4643-8827-749718254FED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
"matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f."
}
],
"id": "CVE-2023-3776",
"lastModified": "2025-02-13T17:16:58.960",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cve-coordination@google.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-07-21T21:15:11.973",
"references": [
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Mailing List",
"Patch",
"Vendor Advisory"
],
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5492"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Patch",
"Vendor Advisory"
],
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5492"
}
],
"sourceIdentifier": "cve-coordination@google.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "cve-coordination@google.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-FCG7-9X44-GX43
Vulnerability from github – Published: 2023-07-21 21:30 – Updated: 2024-08-22 21:31A use-after-free vulnerability in the Linux kernel's net/sched: cls_fw component can be exploited to achieve local privilege escalation.
If tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.
We recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.
{
"affected": [],
"aliases": [
"CVE-2023-3776"
],
"database_specific": {
"cwe_ids": [
"CWE-416"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-07-21T21:15:11Z",
"severity": "HIGH"
},
"details": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\n\n",
"id": "GHSA-fcg7-9x44-gx43",
"modified": "2024-08-22T21:31:27Z",
"published": "2023-07-21T21:30:33Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-3776"
},
{
"type": "WEB",
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"type": "WEB",
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"type": "WEB",
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"type": "WEB",
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"type": "WEB",
"url": "https://security.netapp.com/advisory/ntap-20240202-0003"
},
{
"type": "WEB",
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"type": "WEB",
"url": "https://www.debian.org/security/2023/dsa-5492"
},
{
"type": "WEB",
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"type": "WEB",
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2023-3776
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-3776",
"id": "GSD-2023-3776"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-3776"
],
"details": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\n\n",
"id": "GSD-2023-3776",
"modified": "2023-12-13T01:20:54.283901Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "security@google.com",
"ID": "CVE-2023-3776",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Kernel",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "2.6",
"version_value": "6.5"
}
]
}
}
]
},
"vendor_name": "Linux"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Muhammad Alifa Ramdhan of STAR Labs SG"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-416",
"lang": "eng",
"value": "CWE-416 Use After Free"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f",
"refsource": "MISC",
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"name": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f",
"refsource": "MISC",
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"name": "https://www.debian.org/security/2023/dsa-5480",
"refsource": "MISC",
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"name": "https://www.debian.org/security/2023/dsa-5492",
"refsource": "MISC",
"url": "https://www.debian.org/security/2023/dsa-5492"
},
{
"name": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"name": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html",
"refsource": "MISC",
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"name": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"name": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html",
"refsource": "MISC",
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20240202-0003/",
"refsource": "MISC",
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CC235BB-2BE9-4F58-993C-D5A1C422818E",
"versionEndExcluding": "6.5",
"versionStartIncluding": "2.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:6.5:rc1:*:*:*:*:*:*",
"matchCriteriaId": "0B3E6E4D-E24E-4630-B00C-8C9901C597B0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
"matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FA6FEEC2-9F11-4643-8827-749718254FED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
"matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\n\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.\n\nWe recommend upgrading past commit 0323bce598eea038714f941ce2b22541c46d488f.\n\n"
}
],
"id": "CVE-2023-3776",
"lastModified": "2024-02-02T14:15:53.723",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cve-coordination@google.com",
"type": "Secondary"
}
]
},
"published": "2023-07-21T21:15:11.973",
"references": [
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/175072/Kernel-Live-Patch-Security-Notice-LSN-0098-1.html"
},
{
"source": "cve-coordination@google.com",
"url": "http://packetstormsecurity.com/files/175963/Kernel-Live-Patch-Security-Notice-LSN-0099-1.html"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Mailing List",
"Patch",
"Vendor Advisory"
],
"url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit?id=0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kernel.dance/0323bce598eea038714f941ce2b22541c46d488f"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/10/msg00027.html"
},
{
"source": "cve-coordination@google.com",
"url": "https://lists.debian.org/debian-lts-announce/2024/01/msg00004.html"
},
{
"source": "cve-coordination@google.com",
"url": "https://security.netapp.com/advisory/ntap-20240202-0003/"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5480"
},
{
"source": "cve-coordination@google.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5492"
}
],
"sourceIdentifier": "cve-coordination@google.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "cve-coordination@google.com",
"type": "Secondary"
}
]
}
}
}
}
ICSA-23-166-10
Vulnerability from csaf_cisa - Published: 2023-06-13 00:00 - Updated: 2024-04-09 00:00| URL | Category |
|---|---|
| https://cert-portal.siemens.com/productcert/csaf/… | self |
| https://cert-portal.siemens.com/productcert/html/… | self |
| https://cert-portal.siemens.com/productcert/pdf/s… | self |
| https://cert-portal.siemens.com/productcert/txt/s… | self |
| https://raw.githubusercontent.com/cisagov/CSAF/de… | self |
| https://www.cisa.gov/news-events/ics-advisories/i… | self |
| https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-… | external |
| https://www.cisa.gov/resources-tools/resources/ic… | external |
| https://www.cisa.gov/topics/industrial-control-systems | external |
| https://us-cert.cisa.gov/sites/default/files/reco… | external |
| https://www.cisa.gov/sites/default/files/publicat… | external |
| https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B | external |
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0.\n\nSiemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-831302.json"
},
{
"category": "self",
"summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html"
},
{
"category": "self",
"summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-831302.pdf"
},
{
"category": "self",
"summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-831302.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-166-10 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-10.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-166-10 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-10"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-1500 TM MFP BIOS",
"tracking": {
"current_release_date": "2024-04-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-166-10",
"initial_release_date": "2023-06-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-06-13T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added CVE-2022-1015, CVE-2023-2898, CVE-2023-31248, CVE-2023-3390, CVE-2023-35001, CVE-2023-3610, CVE-2023-3611, CVE-2023-3776, CVE-2023-4004, CVE-2023-4015, CVE-2023-4128, CVE-2023-4147, CVE-2023-4273"
},
{
"date": "2023-11-14T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added CVE-2023-4527, CVE-2023-4806, CVE-2023-4911, CVE-2023-5156"
},
{
"date": "2023-12-12T00:00:00.000000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added CVE-2021-44879, CVE-2023-45863"
},
{
"date": "2024-04-09T00:00:00.000000Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added fix for SIMATIC S7-1500 TM MFP - BIOS"
}
],
"status": "final",
"version": "5"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV1.3.0",
"product": {
"name": "SIMATIC S7-1500 TM MFP - BIOS",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 TM MFP - BIOS"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2016-10228",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2016-10228"
},
{
"cve": "CVE-2019-25013",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The iconv feature in the GNU C Library (aka glibc or libc6) through 2.32, when processing invalid multi-byte input sequences in the EUC-KR encoding, may have a buffer over-read.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-25013"
},
{
"cve": "CVE-2020-1752",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability introduced in glibc upstream version 2.14 was found in the way the tilde expansion was carried out. Directory paths containing an initial tilde followed by a valid username were affected by this issue. A local attacker could exploit this flaw by creating a specially crafted path that, when processed by the glob function, would potentially lead to arbitrary code execution. This was fixed in version 2.32.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2020-1752"
},
{
"cve": "CVE-2020-10029",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The GNU C Library (aka glibc or libc6) before 2.32 could overflow an on-stack buffer during range reduction if an input to an 80-bit long double function contains a non-canonical bit pattern, a seen when passing a 0x5d414141414141410000 value to sinl on x86 targets. This is related to sysdeps/ieee754/ldbl-96/e_rem_pio2l.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2020-10029"
},
{
"cve": "CVE-2020-27618",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid multi-byte input sequences in IBM1364, IBM1371, IBM1388, IBM1390, and IBM1399 encodings, fails to advance the input state, which could lead to an infinite loop in applications, resulting in a denial of service, a different vulnerability from CVE-2016-10228.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2020-27618"
},
{
"cve": "CVE-2020-29562",
"cwe": {
"id": "CWE-617",
"name": "Reachable Assertion"
},
"notes": [
{
"category": "summary",
"text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.30 to 2.32, when converting UCS4 text containing an irreversible character, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2020-29562"
},
{
"cve": "CVE-2021-3326",
"cwe": {
"id": "CWE-617",
"name": "Reachable Assertion"
},
"notes": [
{
"category": "summary",
"text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid input sequences in the ISO-2022-JP-3 encoding, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-3326"
},
{
"cve": "CVE-2021-3998",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in glibc. The realpath() function can mistakenly return an unexpected value, potentially leading to information leakage and disclosure of sensitive data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-3998"
},
{
"cve": "CVE-2021-3999",
"cwe": {
"id": "CWE-193",
"name": "Off-by-one Error"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in glibc. An off-by-one buffer overflow and underflow in getcwd() may lead to memory corruption when the size of the buffer is exactly 1. A local attacker who can control the input buffer and size passed to getcwd() in a setuid program could use this flaw to potentially execute arbitrary code and escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-3999"
},
{
"cve": "CVE-2021-20269",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-20269"
},
{
"cve": "CVE-2021-27645",
"cwe": {
"id": "CWE-415",
"name": "Double Free"
},
"notes": [
{
"category": "summary",
"text": "The nameserver caching daemon (nscd) in the GNU C Library (aka glibc or libc6) 2.29 through 2.33, when processing a request for netgroup lookup, may crash due to a double-free, potentially resulting in degraded service or Denial of Service on the local system. This is related to netgroupcache.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 2.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-27645"
},
{
"cve": "CVE-2021-28831",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-28831"
},
{
"cve": "CVE-2021-33574",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "The mq_notify function in the GNU C Library (aka glibc) versions 2.32 and 2.33 has a use-after-free. It may use the notification thread attributes object (passed through its struct sigevent parameter) after it has been freed by the caller, leading to a denial of service (application crash) or possibly unspecified other impact.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-33574"
},
{
"cve": "CVE-2021-35942",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-35942"
},
{
"cve": "CVE-2021-38604",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "In librt in the GNU C Library (aka glibc) through 2.34, sysdeps/unix/sysv/linux/mq_notify.c mishandles certain NOTIFY_REMOVED data, leading to a NULL pointer dereference. NOTE: this vulnerability was introduced as a side effect of the CVE-2021-33574 fix.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-38604"
},
{
"cve": "CVE-2021-42373",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42373"
},
{
"cve": "CVE-2021-42374",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42374"
},
{
"cve": "CVE-2021-42375",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42375"
},
{
"cve": "CVE-2021-42376",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42376"
},
{
"cve": "CVE-2021-42377",
"cwe": {
"id": "CWE-763",
"name": "Release of Invalid Pointer or Reference"
},
"notes": [
{
"category": "summary",
"text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42377"
},
{
"cve": "CVE-2021-42378",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42378"
},
{
"cve": "CVE-2021-42379",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42379"
},
{
"cve": "CVE-2021-42380",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42380"
},
{
"cve": "CVE-2021-42381",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42381"
},
{
"cve": "CVE-2021-42382",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42382"
},
{
"cve": "CVE-2021-42383",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42383"
},
{
"cve": "CVE-2021-42384",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42384"
},
{
"cve": "CVE-2021-42385",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42385"
},
{
"cve": "CVE-2021-42386",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-42386"
},
{
"cve": "CVE-2021-44879",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "In gc_data_segment in fs/f2fs/gc.c in the Linux kernel before 5.16.3, special files are not considered, leading to a move_data_page NULL pointer dereference.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-44879"
},
{
"cve": "CVE-2022-1015",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the Linux kernel in linux/net/netfilter/nf_tables_api.c of the netfilter subsystem. This flaw allows a local user to cause an out-of-bounds write issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-1015"
},
{
"cve": "CVE-2022-1882",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in the Linux kernel\u2019s pipes functionality in how a user performs manipulations with the pipe post_one_notification() after free_pipe_info() that is already called. This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-1882"
},
{
"cve": "CVE-2022-2585",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in the Linux kernel\u2019s POSIX CPU timers functionality in the way a user creates and then deletes the timer in the non-leader thread of the program. This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-2585"
},
{
"cve": "CVE-2022-2588",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-2588"
},
{
"cve": "CVE-2022-2905",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds memory read flaw was found in the Linux kernel\u0027s BPF subsystem in how a user calls the bpf_tail_call function with a key larger than the max_entries of the map. This flaw allows a local user to gain unauthorized access to data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-2905"
},
{
"cve": "CVE-2022-3028",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A race condition was found in the Linux kernel\u0027s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-3028"
},
{
"cve": "CVE-2022-3435",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability classified as problematic has been found in Linux Kernel. This affects the function fib_nh_match of the file net/ipv4/fib_semantics.c of the component IPv4 Handler. The manipulation leads to out-of-bounds read. It is possible to initiate the attack remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-210357 was assigned to this vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-3435"
},
{
"cve": "CVE-2022-3586",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the Linux kernel\u2019s networking code. A use-after-free was found in the way the sch_sfb enqueue function used the socket buffer (SKB) cb field after the same SKB had been enqueued (and freed) into a child qdisc. This flaw allows a local, unprivileged user to crash the system, causing a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-3586"
},
{
"cve": "CVE-2022-4378",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how a user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-4378"
},
{
"cve": "CVE-2022-4662",
"cwe": {
"id": "CWE-455",
"name": "Non-exit on Failed Initialization"
},
"notes": [
{
"category": "summary",
"text": "A flaw incorrect access control in the Linux kernel USB core subsystem was found in the way user attaches usb device. A local user could use this flaw to crash the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-4662"
},
{
"cve": "CVE-2022-20421",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "In binder_inc_ref_for_node of binder.c, there is a possible way to corrupt memory due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-239630375References: Upstream kernel",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-20421"
},
{
"cve": "CVE-2022-20422",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "In emulation_proc_handler of armv8_deprecated.c, there is a possible way to corrupt memory due to a race condition. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-237540956References: Upstream kernel",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-20422"
},
{
"cve": "CVE-2022-21233",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "Improper isolation of shared resources in some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-21233"
},
{
"cve": "CVE-2022-23218",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-23218"
},
{
"cve": "CVE-2022-23219",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-23219"
},
{
"cve": "CVE-2022-28391",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "BusyBox through 1.35.0 allows remote attackers to execute arbitrary code if netstat is used to print a DNS PTR record\u0027s value to a VT compatible terminal. Alternatively, the attacker could choose to change the terminal\u0027s colors.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-28391"
},
{
"cve": "CVE-2022-30065",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-30065"
},
{
"cve": "CVE-2022-39188",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-39188"
},
{
"cve": "CVE-2022-39190",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in net/netfilter/nf_tables_api.c in the Linux kernel before 5.19.6. A denial of service can occur upon binding to an already bound chain.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-39190"
},
{
"cve": "CVE-2022-40307",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel through 5.19.8. drivers/firmware/efi/capsule-loader.c has a race condition with a resultant use-after-free.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-40307"
},
{
"cve": "CVE-2022-41222",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "mm/mremap.c in the Linux kernel before 5.13.3 has a use-after-free via a stale TLB because an rmap lock is not held during a PUD move.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-41222"
},
{
"cve": "CVE-2022-42703",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double reuse.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-42703"
},
{
"cve": "CVE-2023-0179",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability was found in the Netfilter subsystem in the Linux Kernel. This issue could allow the leakage of both stack and heap addresses, and potentially allow Local Privilege Escalation to the root user via arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-0179"
},
{
"cve": "CVE-2023-0394",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A NULL pointer dereference flaw was found in rawv6_push_pending_frames in net/ipv6/raw.c in the network subcomponent in the Linux kernel. This flaw causes the system to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-0394"
},
{
"cve": "CVE-2023-1073",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A memory corruption flaw was found in the Linux kernel\u2019s human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-1073"
},
{
"cve": "CVE-2023-2898",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "There is a null-pointer-dereference flaw found in f2fs_write_end_io in fs/f2fs/data.c in the Linux kernel. This flaw allows a local privileged user to cause a denial of service problem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-2898"
},
{
"cve": "CVE-2023-3390",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability was found in the Linux kernel\u0027s netfilter subsystem in net/netfilter/nf_tables_api.c.\n\nMishandled error handling with NFT_MSG_NEWRULE makes it possible to use a dangling pointer in the same transaction causing a use-after-free vulnerability. This flaw allows a local attacker with user access to cause a privilege escalation issue.\n\nWe recommend upgrading past commit\u00a01240eb93f0616b21c675416516ff3d74798fdc97.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3390"
},
{
"cve": "CVE-2023-3610",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in the Linux kernel\u0027s netfilter: nf_tables component can be exploited to achieve local privilege escalation.\r\n\r\nFlaw in the error handling of bound chains causes a use-after-free in the abort path of NFT_MSG_NEWRULE. The vulnerability requires CAP_NET_ADMIN to be triggered.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3610"
},
{
"cve": "CVE-2023-3611",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability in the Linux kernel\u0027s net/sched: sch_qfq component can be exploited to achieve local privilege escalation.\r\n\r\nThe qfq_change_agg() function in net/sched/sch_qfq.c allows an out-of-bounds write because lmax is updated according to packet sizes without bounds checks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3611"
},
{
"cve": "CVE-2023-3776",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\r\n\r\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3776"
},
{
"cve": "CVE-2023-4004",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in the Linux kernel\u0027s netfilter in the way a user triggers the nft_pipapo_remove function with the element, without a NFT_SET_EXT_KEY_END. This issue could allow a local user to crash the system or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4004"
},
{
"cve": "CVE-2023-4015",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "The netfilter subsystem in the Linux kernel did not properly handle bound chain deactivation in certain circumstances. A local attacker could possibly use this to cause a denial of service (system crash) or execute arbitrary code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4015"
},
{
"cve": "CVE-2023-4128",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in net/sched/cls_fw.c in classifiers (cls_fw, cls_u32, and cls_route) in the Linux Kernel allows a local attacker to perform a local privilege escalation due to incorrect handling of the existing filter, leading to a kernel information leak.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4128"
},
{
"cve": "CVE-2023-4147",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in the Linux kernel\u2019s Netfilter functionality when adding a rule with NFTA_RULE_CHAIN_ID allows a local user to crash or escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4147"
},
{
"cve": "CVE-2023-4273",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "This vulnerability exists in the implementation of the file name reconstruction function, which is responsible for reading file name entries from a directory index and merging file name parts belonging to one file into a single long file name. Since the file name characters are copied into a stack variable, a local privileged attacker could use this vulnerability to overflow the kernel stack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4273"
},
{
"cve": "CVE-2023-4527",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in glibc. When the getaddrinfo function is called with the AF_UNSPEC address family and the system is configured with no-aaaa mode via /etc/resolv.conf, a DNS response via TCP larger than 2048 bytes can potentially disclose stack contents through the function returned address data, and may cause a crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4527"
},
{
"cve": "CVE-2023-4806",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in glibc. In an extremely rare situation, the getaddrinfo function may access memory that has been freed, resulting in an application crash. This issue is only exploitable when a NSS module implements only the _nss_*_gethostbyname2_r and _nss_*_getcanonname_r hooks without implementing the _nss_*_gethostbyname3_r hook. The resolved name should return a large number of IPv6 and IPv4, and the call to the getaddrinfo function should have the AF_INET6 address family with AI_CANONNAME, AI_ALL and AI_V4MAPPED as flags.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4806"
},
{
"cve": "CVE-2023-4911",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow was discovered in the GNU C Library\u0027s dynamic loader ld.so while processing the GLIBC_TUNABLES environment variable. This issue could allow a local attacker to use maliciously crafted GLIBC_TUNABLES environment variables when launching binaries with SUID permission to execute code with elevated privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-4911"
},
{
"cve": "CVE-2023-5156",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the GNU C Library. A recent fix for CVE-2023-4806 introduced the potential for a memory leak, which may result in an application crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-5156"
},
{
"cve": "CVE-2023-31248",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "Linux Kernel nftables Use-After-Free Local Privilege Escalation Vulnerability; `nft_chain_lookup_byid()` failed to check whether a chain was active and CAP_NET_ADMIN is in any user or network namespace",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-31248"
},
{
"cve": "CVE-2023-35001",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Linux Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-35001"
},
{
"cve": "CVE-2023-45863",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in lib/kobject.c in the Linux kernel before 6.2.3. With root access, an attacker can trigger a race condition that results in a fill_kobj_path out-of-bounds write.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.3.0 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/"
},
{
"category": "workaround",
"details": "Only build and run applications from trusted sources",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-45863"
}
]
}
ICSA-24-046-11
Vulnerability from csaf_cisa - Published: 2024-02-13 00:00 - Updated: 2024-02-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE XCH328 (6GK5328-4TS01-2EC2)
Siemens / SCALANCE XCH328 (6GK5328-4TS01-2EC2)
|
6GK5328-4TS01-2EC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM324 (6GK5324-8TS01-2AC2)
Siemens / SCALANCE XCM324 (6GK5324-8TS01-2AC2)
|
6GK5324-8TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM328 (6GK5328-4TS01-2AC2)
Siemens / SCALANCE XCM328 (6GK5328-4TS01-2AC2)
|
6GK5328-4TS01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XCM332 (6GK5332-0GA01-2AC2)
Siemens / SCALANCE XCM332 (6GK5332-0GA01-2AC2)
|
6GK5332-0GA01-2AC2
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
Siemens / SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)
|
6GK5334-2TS01-2ER3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)
|
6GK5334-3TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
Siemens / SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)
|
6GK5334-2TS01-3AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)
|
6GK5334-3TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
Siemens / SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)
|
6GK5334-2TS01-2AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)
|
6GK5334-3TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
|
SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
Siemens / SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)
|
6GK5334-2TS01-4AR3
|
<V2.4 |
Vendor Fix
fix
|
| URL | Category |
|---|---|
| https://cert-portal.siemens.com/productcert/csaf/… | self |
| https://cert-portal.siemens.com/productcert/html/… | self |
| https://cert-portal.siemens.com/productcert/pdf/s… | self |
| https://cert-portal.siemens.com/productcert/txt/s… | self |
| https://raw.githubusercontent.com/cisagov/CSAF/de… | self |
| https://www.cisa.gov/news-events/ics-advisories/i… | self |
| https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-… | external |
| https://www.cisa.gov/resources-tools/resources/ic… | external |
| https://www.cisa.gov/topics/industrial-control-systems | external |
| https://us-cert.cisa.gov/sites/default/files/reco… | external |
| https://www.cisa.gov/sites/default/files/publicat… | external |
| https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B | external |
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities.\n\nSiemens has released an update for SCALANCE X-300 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.4 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-806742.json"
},
{
"category": "self",
"summary": "SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.4 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-806742.html"
},
{
"category": "self",
"summary": "SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.4 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-806742.pdf"
},
{
"category": "self",
"summary": "SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.4 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-806742.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-046-11 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-046-11.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-046-11 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-11"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SCALANCE XCM-/XRM-300",
"tracking": {
"current_release_date": "2024-02-13T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-046-11",
"initial_release_date": "2024-02-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-02-13T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS01-2EC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK5324-8TS01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4TS01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK5332-0GA01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-2ER3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-4AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"model_numbers": [
"6GK5334-2TS01-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.4",
"product": {
"name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"model_numbers": [
"6GK5334-3TS01-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2006-20001",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A carefully crafted If: request header can cause a memory read, or write of a single zero byte, in a pool (heap) memory location beyond the header value sent. This could cause the process to crash.\n\nThis issue affects Apache HTTP Server 2.4.54 and earlier.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2006-20001"
},
{
"cve": "CVE-2020-10735",
"cwe": {
"id": "CWE-704",
"name": "Incorrect Type Conversion or Cast"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in python. In algorithms with quadratic time complexity using non-binary bases, when using int(\"text\"), a system could take 50ms to parse an int string with 100,000 digits and 5s for 1,000,000 digits (float, decimal, int.from_bytes(), and int() for binary bases 2, 4, 8, 16, and 32 are not affected). The highest threat from this vulnerability is to system availability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-10735"
},
{
"cve": "CVE-2021-3445",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in libdnf\u0027s signature verification functionality in versions before 0.60.1. This flaw allows an attacker to achieve code execution if they can alter the header information of an RPM package and then trick a user or system into installing it. The highest risk of this vulnerability is to confidentiality, integrity, as well as system availability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-3445"
},
{
"cve": "CVE-2021-3638",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds memory access flaw was found in the ATI VGA device emulation of QEMU. This flaw occurs in the ati_2d_blt() routine while handling MMIO write operations when the guest provides invalid values for the destination display parameters. A malicious guest could use this flaw to crash the QEMU process on the host, resulting in a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-3638"
},
{
"cve": "CVE-2021-4037",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in the fs/inode.c:inode_init_owner() function logic of the LInux kernel that allows local users to create files for the XFS file-system with an unintended group ownership and with group execution and SGID permission bits set, in a scenario where a directory is SGID and belongs to a certain group and is writable by a user who is not a member of this group. This can lead to excessive permissions granted in case when they should not. This vulnerability is similar to the previous CVE-2018-13405 and adds the missed fix for the XFS.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-4037"
},
{
"cve": "CVE-2021-36369",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in Dropbear through 2020.81. Due to a non-RFC-compliant check of the available authentication methods in the client-side SSH code, it is possible for an SSH server to change the login process in its favor. This attack can bypass additional security measures such as FIDO2 tokens or SSH-Askpass. Thus, it allows an attacker to abuse a forwarded agent for logging on to another server unnoticed.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-36369"
},
{
"cve": "CVE-2021-43666",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A Denial of Service vulnerability exists in mbed TLS 3.0.0 and earlier in the mbedtls_pkcs12_derivation function when an input password\u0027s length is 0.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-43666"
},
{
"cve": "CVE-2021-45451",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "In Mbed TLS before 3.1.0, psa_aead_generate_nonce allows policy bypass or oracle-based decryption when the output buffer is at memory locations accessible to an untrusted application.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2021-45451"
},
{
"cve": "CVE-2022-1015",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the Linux kernel in linux/net/netfilter/nf_tables_api.c of the netfilter subsystem. This flaw allows a local user to cause an out-of-bounds write issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-1015"
},
{
"cve": "CVE-2022-1348",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in logrotate in how the state file is created. The state file is used to prevent parallel executions of multiple instances of logrotate by acquiring and releasing a file lock. When the state file does not exist, it is created with world-readable permission, allowing an unprivileged user to lock the state file, stopping any rotation. This flaw affects logrotate versions before 3.20.0.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-1348"
},
{
"cve": "CVE-2022-2586",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in nf_tables cross-table in the net/netfilter/nf_tables_api.c function in the Linux kernel. This flaw allows a local, privileged attacker to cause a use-after-free problem at the time of table deletion, possibly leading to local privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-2586"
},
{
"cve": "CVE-2022-2880",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Requests forwarded by ReverseProxy include the raw query parameters from the inbound request, including unparsable parameters rejected by net/http. This could permit query parameter smuggling when a Go proxy forwards a parameter with an unparsable value. After fix, ReverseProxy sanitizes the query parameters in the forwarded query when the outbound request\u0027s Form field is set after the ReverseProxy. Director function returns, indicating that the proxy has parsed the query parameters. Proxies which do not parse query parameters continue to forward the original query parameters unchanged.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-2880"
},
{
"cve": "CVE-2022-3294",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "Users may have access to secure endpoints in the control plane network. Kubernetes clusters are only affected if an untrusted user can modify Node objects and send proxy requests to them. Kubernetes supports node proxying, which allows clients of kube-apiserver to access endpoints of a Kubelet to establish connections to Pods, retrieve container logs, and more. While Kubernetes already validates the proxying address for Nodes, a bug in kube-apiserver made it possible to bypass this validation. Bypassing this validation could allow authenticated requests destined for Nodes to to the API server\u0027s private network.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-3294"
},
{
"cve": "CVE-2022-3437",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A heap-based buffer overflow vulnerability was found in Samba within the GSSAPI unwrap_des() and unwrap_des3() routines of Heimdal. The DES and Triple-DES decryption routines in the Heimdal GSSAPI library allow a length-limited write buffer overflow on malloc() allocated memory when presented with a maliciously small packet. This flaw allows a remote user to send specially crafted malicious data to the application, possibly resulting in a denial of service (DoS) attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-3437"
},
{
"cve": "CVE-2022-3515",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in the Libksba library due to an integer overflow within the CRL parser. The vulnerability can be exploited remotely for code execution on the target system by passing specially crafted data to the application, for example, a malicious S/MIME attachment.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-3515"
},
{
"cve": "CVE-2022-4415",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in systemd. This security flaw can cause a local information leak due to systemd-coredump not respecting the fs.suid_dumpable kernel setting.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-4415"
},
{
"cve": "CVE-2022-4743",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "A potential memory leak issue was discovered in SDL2 in GLES_CreateTexture() function in SDL_render_gles.c. The vulnerability allows an attacker to cause a denial of service attack. The vulnerability affects SDL2 v2.0.4 and above. SDL-1.x are not affected.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-4743"
},
{
"cve": "CVE-2022-4744",
"cwe": {
"id": "CWE-415",
"name": "Double Free"
},
"notes": [
{
"category": "summary",
"text": "A double-free flaw was found in the Linux kernel\u2019s TUN/TAP device driver functionality in how a user registers the device when the register_netdevice function fails (NETDEV_REGISTER notifier). This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-4744"
},
{
"cve": "CVE-2022-4900",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in PHP where setting the environment variable PHP_CLI_SERVER_WORKERS to a large value leads to a heap buffer overflow.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-4900"
},
{
"cve": "CVE-2022-4904",
"cwe": {
"id": "CWE-1284",
"name": "Improper Validation of Specified Quantity in Input"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the c-ares package. The ares_set_sortlist is missing checks about the validity of the input string, which allows a possible arbitrary length stack overflow. This issue may cause a denial of service or a limited impact on confidentiality and integrity.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-4904"
},
{
"cve": "CVE-2022-23471",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "containerd is an open source container runtime. A bug was found in containerd\u0027s CRI implementation where a user can exhaust memory on the host. In the CRI stream server, a goroutine is launched to handle terminal resize events if a TTY is requested. If the user\u0027s process fails to launch due to, for example, a faulty command, the goroutine will be stuck waiting to send without a receiver, resulting in a memory leak. Kubernetes and crictl can both be configured to use containerd\u0027s CRI implementation and the stream server is used for handling container IO. This bug has been fixed in containerd 1.6.12 and 1.5.16. Users should update to these versions to resolve the issue. Users unable to upgrade should ensure that only trusted images and commands are used and that only trusted users have permissions to execute commands in running containers.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-23471"
},
{
"cve": "CVE-2022-23521",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "Git is distributed revision control system. gitattributes are a mechanism to allow defining attributes for paths. These attributes can be defined by adding a `.gitattributes` file to the repository, which contains a set of file patterns and the attributes that should be set for paths matching this pattern. When parsing gitattributes, multiple integer overflows can occur when there is a huge number of path patterns, a huge number of attributes for a single pattern, or when the declared attribute names are huge. These overflows can be triggered via a crafted `.gitattributes` file that may be part of the commit history. Git silently splits lines longer than 2KB when parsing gitattributes from a file, but not when parsing them from the index. Consequentially, the failure mode depends on whether the file exists in the working tree, the index or both. This integer overflow can result in arbitrary heap reads and writes, which may result in remote code execution. The problem has been patched in the versions published on 2023-01-17, going back to v2.30.7. Users are advised to upgrade. There are no known workarounds for this issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-23521"
},
{
"cve": "CVE-2022-24834",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Redis is an in-memory database that persists on disk. A specially crafted Lua script executing in Redis can trigger a heap overflow in the cjson library, and result with heap corruption and potentially remote code execution. The problem exists in all versions of Redis with Lua scripting support, starting from 2.6, and affects only authenticated and authorized users. The problem is fixed in versions 7.0.12, 6.2.13, and 6.0.20.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-24834"
},
{
"cve": "CVE-2022-26691",
"cwe": {
"id": "CWE-697",
"name": "Incorrect Comparison"
},
"notes": [
{
"category": "summary",
"text": "A logic issue was addressed with improved state management. This issue is fixed in Security Update 2022-003 Catalina, macOS Monterey 12.3, macOS Big Sur 11.6.5. An application may be able to gain elevated privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-26691"
},
{
"cve": "CVE-2022-28737",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "There\u0027s a possible overflow in handle_image() when shim tries to load and execute crafted EFI executables; The handle_image() function takes into account the SizeOfRawData field from each section to be loaded. An attacker can leverage this to perform out-of-bound writes into memory. Arbitrary code execution is not discarded in such scenario.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-28737"
},
{
"cve": "CVE-2022-28738",
"cwe": {
"id": "CWE-415",
"name": "Double Free"
},
"notes": [
{
"category": "summary",
"text": "A double free was found in the Regexp compiler in Ruby 3.x before 3.0.4 and 3.1.x before 3.1.2. If a victim attempts to create a Regexp from untrusted user input, an attacker may be able to write to unexpected memory locations.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-28738"
},
{
"cve": "CVE-2022-28739",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "There is a buffer over-read in Ruby before 2.6.10, 2.7.x before 2.7.6, 3.x before 3.0.4, and 3.1.x before 3.1.2. It occurs in String-to-Float conversion, including Kernel#Float and String#to_f.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-28739"
},
{
"cve": "CVE-2022-29154",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in rsync before 3.2.5 that allows malicious remote servers to write arbitrary files inside the directories of connecting peers. The server chooses which files/directories are sent to the client. However, the rsync client performs insufficient validation of file names. A malicious rsync server (or Man-in-The-Middle attacker) can overwrite arbitrary files in the rsync client target directory and subdirectories (for example, overwrite the .ssh/authorized_keys file).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-29154"
},
{
"cve": "CVE-2022-29162",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "summary",
"text": "runc is a CLI tool for spawning and running containers on Linux according to the OCI specification. A bug was found in runc prior to version 1.1.2 where `runc exec --cap` created processes with non-empty inheritable Linux process capabilities, creating an atypical Linux environment and enabling programs with inheritable file capabilities to elevate those capabilities to the permitted set during execve(2). This bug did not affect the container security sandbox as the inheritable set never contained more capabilities than were included in the container\u0027s bounding set. This bug has been fixed in runc 1.1.2. This fix changes `runc exec --cap` behavior such that the additional capabilities granted to the process being executed (as specified via `--cap` arguments) do not include inheritable capabilities. In addition, `runc spec` is changed to not set any inheritable capabilities in the created example OCI spec (`config.json`) file.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-29162"
},
{
"cve": "CVE-2022-29187",
"cwe": {
"id": "CWE-282",
"name": "Improper Ownership Management"
},
"notes": [
{
"category": "summary",
"text": "Git is a distributed revision control system. Git prior to versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5, is vulnerable to privilege escalation in all platforms. An unsuspecting user could still be affected by the issue reported in CVE-2022-24765, for example when navigating as root into a shared tmp directory that is owned by them, but where an attacker could create a git repository. Versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5 contain a patch for this issue. The simplest way to avoid being affected by the exploit described in the example is to avoid running git as root (or an Administrator in Windows), and if needed to reduce its use to a minimum. While a generic workaround is not possible, a system could be hardened from the exploit described in the example by removing any such repository if it exists already and creating one as root to block any future attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-29187"
},
{
"cve": "CVE-2022-29536",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "In GNOME Epiphany before 41.4 and 42.x before 42.2, an HTML document can trigger a client buffer overflow (in ephy_string_shorten in the UI process) via a long page title. The issue occurs because the number of bytes for a UTF-8 ellipsis character is not properly considered.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-29536"
},
{
"cve": "CVE-2022-32148",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "Improper exposure of client IP addresses in net/http before Go 1.17.12 and Go 1.18.4 can be triggered by calling httputil.ReverseProxy.ServeHTTP with a Request.Header map containing a nil value for the X-Forwarded-For header, which causes ReverseProxy to set the client IP as the value of the X-Forwarded-For header.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-32148"
},
{
"cve": "CVE-2022-34903",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "GnuPG through 2.3.6, in unusual situations where an attacker possesses any secret-key information from a victim\u0027s keyring and other constraints (e.g., use of GPGME) are met, allows signature forgery via injection into the status line.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-34903"
},
{
"cve": "CVE-2022-34918",
"cwe": {
"id": "CWE-843",
"name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel through 5.18.9. A type confusion bug in nft_set_elem_init (leading to a buffer overflow) could be used by a local attacker to escalate privileges, a different vulnerability than CVE-2022-32250. (The attacker can obtain root access, but must start with an unprivileged user namespace to obtain CAP_NET_ADMIN access.) This can be fixed in nft_setelem_parse_data in net/netfilter/nf_tables_api.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-34918"
},
{
"cve": "CVE-2022-36021",
"cwe": {
"id": "CWE-407",
"name": "Inefficient Algorithmic Complexity"
},
"notes": [
{
"category": "summary",
"text": "Redis is an in-memory database that persists on disk. Authenticated users can use string matching commands (like `SCAN` or `KEYS`) with a specially crafted pattern to trigger a denial-of-service attack on Redis, causing it to hang and consume 100% CPU time. The problem is fixed in Redis versions 6.0.18, 6.2.11, 7.0.9.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-36021"
},
{
"cve": "CVE-2022-36227",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "In libarchive before 3.6.2, the software does not check for an error after calling calloc function that can return with a NULL pointer if the function fails, which leads to a resultant NULL pointer dereference. NOTE: the discoverer cites this CWE-476 remark but third parties dispute the code-execution impact: \"In rare circumstances, when NULL is equivalent to the 0x0 memory address and privileged code can access it, then writing or reading memory is possible, which may lead to code execution.\"",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-36227"
},
{
"cve": "CVE-2022-36760",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request Smuggling\u0027) vulnerability in mod_proxy_ajp of Apache HTTP Server allows an attacker to smuggle requests to the AJP server it forwards requests to. This issue affects Apache HTTP Server Apache HTTP Server 2.4 version 2.4.54 and prior versions.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-36760"
},
{
"cve": "CVE-2022-37436",
"cwe": {
"id": "CWE-113",
"name": "Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Request/Response Splitting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Prior to Apache HTTP Server 2.4.55, a malicious backend can cause the response headers to be truncated early, resulting in some headers being incorporated into the response body. If the later headers have any security purpose, they will not be interpreted by the client.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-37436"
},
{
"cve": "CVE-2022-37454",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "The Keccak XKCP SHA-3 reference implementation before fdc6fef has an integer overflow and resultant buffer overflow that allows attackers to execute arbitrary code or eliminate expected cryptographic properties. This occurs in the sponge function interface.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-37454"
},
{
"cve": "CVE-2022-37797",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "In lighttpd 1.4.65, mod_wstunnel does not initialize a handler function pointer if an invalid HTTP request (websocket handshake) is received. It leads to null pointer dereference which crashes the server. It could be used by an external attacker to cause denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-37797"
},
{
"cve": "CVE-2022-38725",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "An integer overflow in the RFC3164 parser in One Identity syslog-ng 3.0 through 3.37 allows remote attackers to cause a Denial of Service via crafted syslog input that is mishandled by the tcp or network function. syslog-ng Premium Edition 7.0.30 and syslog-ng Store Box 6.10.0 are also affected.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-38725"
},
{
"cve": "CVE-2022-39189",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered the x86 KVM subsystem in the Linux kernel before 5.18.17. Unprivileged guest users can compromise the guest kernel because TLB flush operations are mishandled in certain KVM_VCPU_PREEMPTED situations.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-39189"
},
{
"cve": "CVE-2022-39260",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Git is an open source, scalable, distributed revision control system. `git shell` is a restricted login shell that can be used to implement Git\u0027s push/pull functionality via SSH. In versions prior to 2.30.6, 2.31.5, 2.32.4, 2.33.5, 2.34.5, 2.35.5, 2.36.3, and 2.37.4, the function that splits the command arguments into an array improperly uses an `int` to represent the number of entries in the array, allowing a malicious actor to intentionally overflow the return value, leading to arbitrary heap writes. Because the resulting array is then passed to `execv()`, it is possible to leverage this attack to gain remote code execution on a victim machine. Note that a victim must first allow access to `git shell` as a login shell in order to be vulnerable to this attack. This problem is patched in versions 2.30.6, 2.31.5, 2.32.4, 2.33.5, 2.34.5, 2.35.5, 2.36.3, and 2.37.4 and users are advised to upgrade to the latest version. Disabling `git shell` access via remote logins is a viable short-term workaround.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-39260"
},
{
"cve": "CVE-2022-41409",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "Integer overflow vulnerability in pcre2test before 10.41 allows attackers to cause a denial of service or other unspecified impacts via negative input.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41409"
},
{
"cve": "CVE-2022-41556",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "A resource leak in gw_backend.c in lighttpd 1.4.56 through 1.4.66 could lead to a denial of service (connection-slot exhaustion) after a large amount of anomalous TCP behavior by clients. It is related to RDHUP mishandling in certain HTTP/1.1 chunked situations. Use of mod_fastcgi is, for example, affected. This is fixed in 1.4.67.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41556"
},
{
"cve": "CVE-2022-41715",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "Programs which compile regular expressions from untrusted sources may be vulnerable to memory exhaustion or denial of service. The parsed regexp representation is linear in the size of the input, but in some cases the constant factor can be as high as 40,000, making relatively small regexps consume much larger amounts of memory. After fix, each regexp being parsed is limited to a 256 MB memory footprint. Regular expressions whose representation would use more space than that are rejected. Normal use of regular expressions is unaffected.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41715"
},
{
"cve": "CVE-2022-41717",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "An attacker can cause excessive memory growth in a Go server accepting HTTP/2 requests. HTTP/2 server connections contain a cache of HTTP header keys sent by the client. While the total number of entries in this cache is capped, an attacker sending very large keys can cause the server to allocate approximately 64 MiB per open connection.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41717"
},
{
"cve": "CVE-2022-41723",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A maliciously crafted HTTP/2 stream could cause excessive CPU consumption in the HPACK decoder, sufficient to cause a denial of service from a small number of small requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41723"
},
{
"cve": "CVE-2022-41860",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "In freeradius, when an EAP-SIM supplicant sends an unknown SIM option, the server will try to look that option up in the internal dictionaries. This lookup will fail, but the SIM code will not check for that failure. Instead, it will dereference a NULL pointer, and cause the server to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41860"
},
{
"cve": "CVE-2022-41861",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in freeradius. A malicious RADIUS client or home server can send a malformed abinary attribute which can cause the server to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41861"
},
{
"cve": "CVE-2022-41862",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "In PostgreSQL, a modified, unauthenticated server can send an unterminated string during the establishment of Kerberos transport encryption. In certain conditions a server can cause a libpq client to over-read and report an error message containing uninitialized bytes.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41862"
},
{
"cve": "CVE-2022-41903",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "Git is distributed revision control system. `git log` can display commits in an arbitrary format using its `--format` specifiers. This functionality is also exposed to `git archive` via the `export-subst` gitattribute. When processing the padding operators, there is a integer overflow in `pretty.c::format_and_pad_commit()` where a `size_t` is stored improperly as an `int`, and then added as an offset to a `memcpy()`. This overflow can be triggered directly by a user running a command which invokes the commit formatting machinery (e.g., `git log --format=...`). It may also be triggered indirectly through git archive via the export-subst mechanism, which expands format specifiers inside of files within the repository during a git archive. This integer overflow can result in arbitrary heap writes, which may result in arbitrary code execution. The problem has been patched in the versions published on 2023-01-17, going back to v2.30.7. Users are advised to upgrade. Users who are unable to upgrade should disable `git archive` in untrusted repositories. If you expose git archive via `git daemon`, disable it by running `git config --global daemon.uploadArch false`.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-41903"
},
{
"cve": "CVE-2022-42919",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "Python 3.9.x before 3.9.16 and 3.10.x before 3.10.9 on Linux allows local privilege escalation in a non-default configuration. The Python multiprocessing library, when used with the forkserver start method on Linux, allows pickles to be deserialized from any user in the same machine local network namespace, which in many system configurations means any user on the same machine. Pickles can execute arbitrary code. Thus, this allows for local user privilege escalation to the user that any forkserver process is running as. Setting multiprocessing.util.abstract_sockets_supported to False is a workaround. The forkserver start method for multiprocessing is not the default start method. This issue is Linux specific because only Linux supports abstract namespace sockets. CPython before 3.9 does not make use of Linux abstract namespace sockets by default. Support for users manually specifying an abstract namespace socket was added as a bugfix in 3.7.8 and 3.8.3, but users would need to make specific uncommon API calls in order to do that in CPython before 3.9.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-42919"
},
{
"cve": "CVE-2022-44370",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "NASM v2.16 was discovered to contain a heap buffer overflow in the component quote_for_pmake() asm/nasm.c:856",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-44370"
},
{
"cve": "CVE-2022-45061",
"cwe": {
"id": "CWE-407",
"name": "Inefficient Algorithmic Complexity"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in Python before 3.11.1. An unnecessary quadratic algorithm exists in one path when processing some inputs to the IDNA (RFC 3490) decoder, such that a crafted, unreasonably long name being presented to the decoder could lead to a CPU denial of service. Hostnames are often supplied by remote servers that could be controlled by a malicious actor; in such a scenario, they could trigger excessive CPU consumption on the client attempting to make use of an attacker-supplied supposed hostname. For example, the attack payload could be placed in the Location header of an HTTP response with status code 302. A fix is planned in 3.11.1, 3.10.9, 3.9.16, 3.8.16, and 3.7.16.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-45061"
},
{
"cve": "CVE-2022-45142",
"cwe": {
"id": "CWE-354",
"name": "Improper Validation of Integrity Check Value"
},
"notes": [
{
"category": "summary",
"text": "The fix for CVE-2022-3437 included changing memcmp to be constant time and a workaround for a compiler bug by adding \"!= 0\" comparisons to the result of memcmp. When these patches were backported to the heimdal-7.7.1 and heimdal-7.8.0 branches (and possibly other branches) a logic inversion sneaked in causing the validation of message integrity codes in gssapi/arcfour to be inverted.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-45142"
},
{
"cve": "CVE-2022-45919",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel through 6.0.10. In drivers/media/dvb-core/dvb_ca_en50221.c, a use-after-free can occur is there is a disconnect after an open, because of the lack of a wait_event.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-45919"
},
{
"cve": "CVE-2022-46392",
"cwe": {
"id": "CWE-203",
"name": "Observable Discrepancy"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in Mbed TLS before 2.28.2 and 3.x before 3.3.0. An adversary with access to precise enough information about memory accesses (typically, an untrusted operating system attacking a secure enclave) can recover an RSA private key after observing the victim performing a single private-key operation, if the window size (MBEDTLS_MPI_WINDOW_SIZE) used for the exponentiation is 3 or smaller.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-46392"
},
{
"cve": "CVE-2022-46393",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in Mbed TLS before 2.28.2 and 3.x before 3.3.0. There is a potential heap-based buffer overflow and heap-based buffer over-read in DTLS if MBEDTLS_SSL_DTLS_CONNECTION_ID is enabled and MBEDTLS_SSL_CID_IN_LEN_MAX \u003e 2 * MBEDTLS_SSL_CID_OUT_LEN_MAX.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-46393"
},
{
"cve": "CVE-2022-47629",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "Libksba before 1.6.3 is prone to an integer overflow vulnerability in the CRL signature parser.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-47629"
},
{
"cve": "CVE-2022-48303",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "GNU Tar through 1.34 has a one-byte out-of-bounds read that results in use of uninitialized memory for a conditional jump. Exploitation to change the flow of control has not been demonstrated. The issue occurs in from_header in list.c via a V7 archive in which mtime has approximately 11 whitespace characters.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-48303"
},
{
"cve": "CVE-2022-48434",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "libavcodec/pthread_frame.c in FFmpeg before 5.1.2, as used in VLC and other products, leaves stale hwaccel state in worker threads, which allows attackers to trigger a use-after-free and execute arbitrary code in some circumstances (e.g., hardware re-initialization upon a mid-video SPS change when Direct3D11 is used).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-48434"
},
{
"cve": "CVE-2023-0160",
"cwe": {
"id": "CWE-667",
"name": "Improper Locking"
},
"notes": [
{
"category": "summary",
"text": "A deadlock flaw was found in the Linux kernel\u2019s BPF subsystem. This flaw allows a local user to potentially crash the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0160"
},
{
"cve": "CVE-2023-0330",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in the lsi53c895a device affects the latest version of qemu. A DMA-MMIO reentrancy problem may lead to memory corruption bugs like stack overflow or use-after-free.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0330"
},
{
"cve": "CVE-2023-0361",
"cwe": {
"id": "CWE-203",
"name": "Observable Discrepancy"
},
"notes": [
{
"category": "summary",
"text": "A timing side-channel in the handling of RSA ClientKeyExchange messages was discovered in GnuTLS. This side-channel can be sufficient to recover the key encrypted in the RSA ciphertext across a network in a Bleichenbacher style attack. To achieve a successful decryption the attacker would need to send a large amount of specially crafted messages to the vulnerable server. By recovering the secret from the ClientKeyExchange message, the attacker would be able to decrypt the application data exchanged over that connection.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0361"
},
{
"cve": "CVE-2023-0494",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in X.Org. This issue occurs due to a dangling pointer in DeepCopyPointerClasses that can be exploited by ProcXkbSetDeviceInfo() and ProcXkbGetDeviceInfo() to read and write into freed memory. This can lead to local privilege elevation on systems where the X server runs privileged and remote code execution for ssh X forwarding sessions.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0494"
},
{
"cve": "CVE-2023-0567",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, password_verify() function may accept some invalid Blowfish hashes as valid. If such invalid hash ever ends up in the password database, it may lead to an application allowing any password for this entry as valid.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0567"
},
{
"cve": "CVE-2023-0568",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "summary",
"text": "In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, core path resolution function allocate buffer one byte too small. When resolving paths with lengths close to system MAXPATHLEN setting, this may lead to the byte after the allocated buffer being overwritten with NUL value, which might lead to unauthorized data access or modification.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0568"
},
{
"cve": "CVE-2023-0590",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in qdisc_graft in net/sched/sch_api.c in the Linux Kernel due to a race problem. This flaw leads to a denial of service issue. If patch ebda44da44f6 (\"net: sched: fix race condition in qdisc_graft()\") not applied yet, then kernel could be affected.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0590"
},
{
"cve": "CVE-2023-0662",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "In PHP 8.0.X before 8.0.28, 8.1.X before 8.1.16 and 8.2.X before 8.2.3, excessive number of parts in HTTP form upload can cause high resource consumption and excessive number of log entries. This can cause denial of service on the affected server by exhausting CPU resources or disk space.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-0662"
},
{
"cve": "CVE-2023-1206",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "A hash collision flaw was found in the IPv6 connection lookup table in the Linux kernel\u2019s IPv6 functionality when a user makes a new kind of SYN flood attack. A user located in the local network or with a high bandwidth connection can increase the CPU usage of the server that accepts IPV6 connections up to 95%.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1206"
},
{
"cve": "CVE-2023-1380",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "A slab-out-of-bound read problem was found in brcmf_get_assoc_ies in drivers/net/wireless/broadcom/brcm80211/brcmfmac/cfg80211.c in the Linux Kernel. This issue could occur when assoc_info-\u003ereq_len data is bigger than the size of the buffer, defined as WL_EXTRA_BUF_MAX, leading to a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1380"
},
{
"cve": "CVE-2023-1393",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in X.Org Server Overlay Window. A Use-After-Free may lead to local privilege escalation. If a client explicitly destroys the compositor overlay window (aka COW), the Xserver would leave a dangling pointer to that window in the CompScreen structure, which will trigger a use-after-free later.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1393"
},
{
"cve": "CVE-2023-1611",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in btrfs_search_slot in fs/btrfs/ctree.c in btrfs in the Linux Kernel.This flaw allows an attacker to crash the system and possibly cause a kernel information lea",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1611"
},
{
"cve": "CVE-2023-1670",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A flaw use after free in the Linux kernel Xircom 16-bit PCMCIA (PC-card) Ethernet driver was found.A local user could use this flaw to crash the system or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1670"
},
{
"cve": "CVE-2023-1838",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in vhost_net_set_backend in drivers/vhost/net.c in virtio network subcomponent in the Linux kernel due to a double fget. This flaw could allow a local attacker to crash the system, and could even lead to a kernel information leak problem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1838"
},
{
"cve": "CVE-2023-1855",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in xgene_hwmon_remove in drivers/hwmon/xgene-hwmon.c in the Hardware Monitoring Linux Kernel Driver (xgene-hwmon). This flaw could allow a local attacker to crash the system due to a race problem. This vulnerability could even lead to a kernel information leak problem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1855"
},
{
"cve": "CVE-2023-1859",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in xen_9pfs_front_removet in net/9p/trans_xen.c in Xen transport for 9pfs in the Linux Kernel. This flaw could allow a local attacker to crash the system due to a race problem, possibly leading to a kernel information leak.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1859"
},
{
"cve": "CVE-2023-1989",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in btsdio_remove in drivers\\bluetooth\\btsdio.c in the Linux Kernel. In this flaw, a call to btsdio_remove with an unfinished job, may cause a race problem leading to a UAF on hdev devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1989"
},
{
"cve": "CVE-2023-1990",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in ndlc_remove in drivers/nfc/st-nci/ndlc.c in the Linux Kernel. This flaw could allow an attacker to crash the system due to a race problem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-1990"
},
{
"cve": "CVE-2023-2002",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in the HCI sockets implementation due to a missing capability check in net/bluetooth/hci_sock.c in the Linux Kernel. This flaw allows an attacker to unauthorized execution of management commands, compromising the confidentiality, integrity, and availability of Bluetooth communication.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2002"
},
{
"cve": "CVE-2023-2124",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds memory access flaw was found in the Linux kernel\u2019s XFS file system in how a user restores an XFS image after failure (with a dirty log journal). This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2124"
},
{
"cve": "CVE-2023-2194",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability was found in the Linux kernel\u0027s SLIMpro I2C device driver. The userspace \"data-\u003eblock[0]\" variable was not capped to a number between 0-255 and was used as the size of a memcpy, possibly writing beyond the end of dma_buffer. This flaw could allow a local privileged user to crash the system or potentially achieve code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2194"
},
{
"cve": "CVE-2023-2269",
"cwe": {
"id": "CWE-667",
"name": "Improper Locking"
},
"notes": [
{
"category": "summary",
"text": "A denial of service problem was found, due to a possible recursive locking scenario, resulting in a deadlock in table_clear in drivers/md/dm-ioctl.c in the Linux Kernel Device Mapper-Multipathing sub-component.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2269"
},
{
"cve": "CVE-2023-2861",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the 9p passthrough filesystem (9pfs) implementation in QEMU. The 9pfs server did not prohibit opening special files on the host side, potentially allowing a malicious client to escape from the exported 9p tree by creating and opening a device file in the shared folder.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2861"
},
{
"cve": "CVE-2023-2953",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability was found in openldap. This security flaw causes a null pointer dereference in ber_memalloc_x() function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-2953"
},
{
"cve": "CVE-2023-3006",
"cwe": {
"id": "CWE-212",
"name": "Improper Removal of Sensitive Information Before Storage or Transfer"
},
"notes": [
{
"category": "summary",
"text": "A known cache speculation vulnerability, known as Branch History Injection (BHI) or Spectre-BHB, becomes actual again for the new hw AmpereOne. Spectre-BHB is similar to Spectre v2, except that malicious code uses the shared branch history (stored in the CPU Branch History Buffer, or BHB) to influence mispredicted branches within the victim\u0027s hardware context. Once that occurs, speculation caused by the mispredicted branches can cause cache allocation. This issue leads to obtaining information that should not be accessible.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3006"
},
{
"cve": "CVE-2023-3090",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "A heap out-of-bounds write vulnerability in the Linux Kernel ipvlan network driver can be exploited to achieve local privilege escalation.\n\nThe out-of-bounds write is caused by missing skb-\u003ecb initialization in the ipvlan network driver. The vulnerability is reachable if\u00a0CONFIG_IPVLAN is enabled.\n\n\nWe recommend upgrading past commit 90cbed5247439a966b645b34eb0a2e037836ea8e.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3090"
},
{
"cve": "CVE-2023-3111",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use after free vulnerability was found in prepare_to_relocate in fs/btrfs/relocation.c in btrfs in the Linux Kernel. This possible flaw can be triggered by calling btrfs_ioctl_balance() before calling btrfs_ioctl_defrag().",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3111"
},
{
"cve": "CVE-2023-3141",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in r592_remove in drivers/memstick/host/r592.c in media access in the Linux Kernel. This flaw allows a local attacker to crash the system at device disconnect, possibly leading to a kernel information leak.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3141"
},
{
"cve": "CVE-2023-3212",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "A NULL pointer dereference issue was found in the gfs2 file system in the Linux kernel. It occurs on corrupt gfs2 file systems when the evict code tries to reference the journal descriptor structure after it has been freed and set to NULL. A privileged local user could use this flaw to cause a kernel panic.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3212"
},
{
"cve": "CVE-2023-3247",
"cwe": {
"id": "CWE-252",
"name": "Unchecked Return Value"
},
"notes": [
{
"category": "summary",
"text": "In PHP versions 8.0.* before 8.0.29, 8.1.* before 8.1.20, 8.2.* before 8.2.7 when using SOAP HTTP Digest Authentication, random value generator was not checked for failure, and was using narrower range of values than it should have. In case of random generator failure, it could lead to a disclosure of 31 bits of uninitialized memory from the client to the server, and it also made easier to a malicious server to guess the client\u0027s nonce.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3247"
},
{
"cve": "CVE-2023-3268",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An out of bounds (OOB) memory access flaw was found in the Linux kernel in relay_file_read_start_pos in kernel/relay.c in the relayfs. This flaw could allow a local attacker to crash the system or leak kernel internal information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3268"
},
{
"cve": "CVE-2023-3301",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in QEMU. The async nature of hot-unplug enables a race scenario where the net device backend is cleared before the virtio-net pci frontend has been unplugged. A malicious guest could use this time window to trigger an assertion and cause a denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3301"
},
{
"cve": "CVE-2023-3316",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "A NULL pointer dereference in TIFFClose() is caused by a failure to open an output file (non-existent path or a path that requires permissions like /dev/null) while specifying zones.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3316"
},
{
"cve": "CVE-2023-3390",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability was found in the Linux kernel\u0027s netfilter subsystem in net/netfilter/nf_tables_api.c.\n\nMishandled error handling with NFT_MSG_NEWRULE makes it possible to use a dangling pointer in the same transaction causing a use-after-free vulnerability. This flaw allows a local attacker with user access to cause a privilege escalation issue.\n\nWe recommend upgrading past commit\u00a01240eb93f0616b21c675416516ff3d74798fdc97.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3390"
},
{
"cve": "CVE-2023-3611",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability in the Linux kernel\u0027s net/sched: sch_qfq component can be exploited to achieve local privilege escalation.\r\n\r\nThe qfq_change_agg() function in net/sched/sch_qfq.c allows an out-of-bounds write because lmax is updated according to packet sizes without bounds checks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3611"
},
{
"cve": "CVE-2023-3776",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\r\n\r\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3776"
},
{
"cve": "CVE-2023-3863",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free flaw was found in nfc_llcp_find_local in net/nfc/llcp_core.c in NFC in the Linux kernel. This flaw allows a local user with special privileges to impact a kernel information leak issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-3863"
},
{
"cve": "CVE-2023-4128",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A use-after-free vulnerability in net/sched/cls_fw.c in classifiers (cls_fw, cls_u32, and cls_route) in the Linux Kernel allows a local attacker to perform a local privilege escalation due to incorrect handling of the existing filter, leading to a kernel information leak.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-4128"
},
{
"cve": "CVE-2023-4194",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in the Linux kernel\u0027s TUN/TAP functionality. This issue could allow a local user to bypass network filters and gain unauthorized access to some resources. The original patches fixing CVE-2023-1076 are incorrect or incomplete. The problem is that the following upstream commits - a096ccca6e50 (\"tun: tun_chr_open(): correctly initialize socket uid\"), - 66b2c338adce (\"tap: tap_open(): correctly initialize socket uid\"), pass \"inode-\u003ei_uid\" to sock_init_data_uid() as the last parameter and that turns out to not be accurate.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-4194"
},
{
"cve": "CVE-2023-20593",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue in \u201cZen 2\u201d CPUs, under specific microarchitectural circumstances, may allow an attacker to potentially access sensitive information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-20593"
},
{
"cve": "CVE-2023-21255",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "In multiple functions of binder.c, there is a possible memory corruption due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-21255"
},
{
"cve": "CVE-2023-22490",
"cwe": {
"id": "CWE-59",
"name": "Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Git is a revision control system. Using a specially-crafted repository, Git prior to versions 2.39.2, 2.38.4, 2.37.6, 2.36.5, 2.35.7, 2.34.7, 2.33.7, 2.32.6, 2.31.7, and 2.30.8 can be tricked into using its local clone optimization even when using a non-local transport. Though Git will abort local clones whose source `$GIT_DIR/objects` directory contains symbolic links, the `objects` directory itself may still be a symbolic link. These two may be combined to include arbitrary files based on known paths on the victim\u0027s filesystem within the malicious repository\u0027s working copy, allowing for data exfiltration in a similar manner as CVE-2022-39253.\n\nA fix has been prepared and will appear in v2.39.2 v2.38.4 v2.37.6 v2.36.5 v2.35.7 v2.34.7 v2.33.7 v2.32.6, v2.31.7 and v2.30.8. If upgrading is impractical, two short-term workarounds are available. Avoid cloning repositories from untrusted sources with `--recurse-submodules`. Instead, consider cloning repositories without recursively cloning their submodules, and instead run `git submodule update` at each layer. Before doing so, inspect each new `.gitmodules` file to ensure that it does not contain suspicious module URLs.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-22490"
},
{
"cve": "CVE-2023-22742",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "libgit2 is a cross-platform, linkable library implementation of Git. When using an SSH remote with the optional libssh2 backend, libgit2 does not perform certificate checking by default. Prior versions of libgit2 require the caller to set the `certificate_check` field of libgit2\u0027s `git_remote_callbacks` structure - if a certificate check callback is not set, libgit2 does not perform any certificate checking. This means that by default - without configuring a certificate check callback, clients will not perform validation on the server SSH keys and may be subject to a man-in-the-middle attack. Users are encouraged to upgrade to v1.4.5 or v1.5.1. Users unable to upgrade should ensure that all relevant certificates are manually checked.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-22742"
},
{
"cve": "CVE-2023-22745",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "tpm2-tss is an open source software implementation of the Trusted Computing Group (TCG) Trusted Platform Module (TPM) 2 Software Stack (TSS2). In affected versions `Tss2_RC_SetHandler` and `Tss2_RC_Decode` both index into `layer_handler` with an 8 bit layer number, but the array only has `TPM2_ERROR_TSS2_RC_LAYER_COUNT` entries, so trying to add a handler for higher-numbered layers or decode a response code with such a layer number reads/writes past the end of the buffer. This Buffer overrun, could result in arbitrary code execution. An example attack would be a MiTM bus attack that returns 0xFFFFFFFF for the RC. Given the common use case of TPM modules an attacker must have local access to the target machine with local system privileges which allows access to the TPM system. Usually TPM access requires administrative privilege.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-22745"
},
{
"cve": "CVE-2023-23454",
"cwe": {
"id": "CWE-843",
"name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
},
"notes": [
{
"category": "summary",
"text": "cbq_classify in net/sched/sch_cbq.c in the Linux kernel through 6.1.4 allows attackers to cause a denial of service (slab-out-of-bounds read) because of type confusion (non-negative numbers can sometimes indicate a TC_ACT_SHOT condition rather than valid classification results).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-23454"
},
{
"cve": "CVE-2023-23931",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "cryptography is a package designed to expose cryptographic primitives and recipes to Python developers. In affected versions `Cipher.update_into` would accept Python objects which implement the buffer protocol, but provide only immutable buffers. This would allow immutable objects (such as `bytes`) to be mutated, thus violating fundamental rules of Python and resulting in corrupted output. This now correctly raises an exception. This issue has been present since `update_into` was originally introduced in cryptography 1.8.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-23931"
},
{
"cve": "CVE-2023-23934",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "Werkzeug is a comprehensive WSGI web application library. Browsers may allow \"nameless\" cookies that look like `=value` instead of `key=value`. A vulnerable browser may allow a compromised application on an adjacent subdomain to exploit this to set a cookie like `=__Host-test=bad` for another subdomain. Werkzeug prior to 2.2.3 will parse the cookie `=__Host-test=bad` as __Host-test=bad`. If a Werkzeug application is running next to a vulnerable or malicious subdomain which sets such a cookie using a vulnerable browser, the Werkzeug application will see the bad cookie value but the valid cookie key. The issue is fixed in Werkzeug 2.2.3.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-23934"
},
{
"cve": "CVE-2023-23946",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Git, a revision control system, is vulnerable to path traversal prior to versions 2.39.2, 2.38.4, 2.37.6, 2.36.5, 2.35.7, 2.34.7, 2.33.7, 2.32.6, 2.31.7, and 2.30.8. By feeding a crafted input to `git apply`, a path outside the working tree can be overwritten as the user who is running `git apply`. A fix has been prepared and will appear in v2.39.2, v2.38.4, v2.37.6, v2.36.5, v2.35.7, v2.34.7, v2.33.7, v2.32.6, v2.31.7, and v2.30.8. As a workaround, use `git apply --stat` to inspect a patch before applying; avoid applying one that creates a symbolic link and then creates a file beyond the symbolic link.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-23946"
},
{
"cve": "CVE-2023-24538",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Templates do not properly consider backticks (`) as Javascript string delimiters, and do not escape them as expected. Backticks are used, since ES6, for JS template literals. If a template contains a Go template action within a Javascript template literal, the contents of the action can be used to terminate the literal, injecting arbitrary Javascript code into the Go template. As ES6 template literals are rather complex, and themselves can do string interpolation, the decision was made to simply disallow Go template actions from being used inside of them (e.g. \"var a = {{.}}\"), since there is no obviously safe way to allow this behavior. This takes the same approach as github.com/google/safehtml. With fix, Template.Parse returns an Error when it encounters templates like this, with an ErrorCode of value 12. This ErrorCode is currently unexported, but will be exported in the release of Go 1.21. Users who rely on the previous behavior can re-enable it using the GODEBUG flag jstmpllitinterp=1, with the caveat that backticks will now be escaped. This should be used with caution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-24538"
},
{
"cve": "CVE-2023-25153",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "containerd is an open source container runtime. Before versions 1.6.18 and 1.5.18, when importing an OCI image, there was no limit on the number of bytes read for certain files. A maliciously crafted image with a large file where a limit was not applied could cause a denial of service. This bug has been fixed in containerd 1.6.18 and 1.5.18. Users should update to these versions to resolve the issue. As a workaround, ensure that only trusted images are used and that only trusted users have permissions to import images.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25153"
},
{
"cve": "CVE-2023-25155",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "Redis is an in-memory database that persists on disk. Authenticated users issuing specially crafted `SRANDMEMBER`, `ZRANDMEMBER`, and `HRANDFIELD` commands can trigger an integer overflow, resulting in a runtime assertion and termination of the Redis server process. This problem affects all Redis versions. Patches were released in Redis version(s) 6.0.18, 6.2.11 and 7.0.9.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25155"
},
{
"cve": "CVE-2023-25193",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "hb-ot-layout-gsubgpos.hh in HarfBuzz through 6.0.0 allows attackers to trigger quadratic growth via consecutive marks during the process of looking back for base glyphs when attaching marks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25193"
},
{
"cve": "CVE-2023-25588",
"cwe": {
"id": "CWE-908",
"name": "Use of Uninitialized Resource"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in Binutils. The field `the_bfd` of `asymbol`struct is uninitialized in the `bfd_mach_o_get_synthetic_symtab` function, which may lead to an application crash and local denial of service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25588"
},
{
"cve": "CVE-2023-25690",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Some mod_proxy configurations on Apache HTTP Server versions 2.4.0 through 2.4.55 allow a HTTP Request Smuggling attack.\r\n\r\nConfigurations are affected when mod_proxy is enabled along with some form of RewriteRule or ProxyPassMatch in which a non-specific pattern matches some portion of the user-supplied request-target (URL) data and is then re-inserted into the proxied request-target using variable substitution. \r\n\r\nRequest splitting/smuggling could result in bypass of access controls in the proxy server, proxying unintended URLs to existing origin servers, and cache poisoning. Users are recommended to update to at least version 2.4.56 of Apache HTTP Server.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25690"
},
{
"cve": "CVE-2023-25727",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "In phpMyAdmin before 4.9.11 and 5.x before 5.2.1, an authenticated user can trigger XSS by uploading a crafted .sql file through the drag-and-drop interface.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-25727"
},
{
"cve": "CVE-2023-26081",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"category": "summary",
"text": "In Epiphany (aka GNOME Web) through 43.0, untrusted web content can trick users into exfiltrating passwords, because autofill occurs in sandboxed contexts.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-26081"
},
{
"cve": "CVE-2023-26965",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "loadImage() in tools/tiffcrop.c in LibTIFF through 4.5.0 has a heap-based use after free via a crafted TIFF image.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-26965"
},
{
"cve": "CVE-2023-27522",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "summary",
"text": "HTTP Response Smuggling vulnerability in Apache HTTP Server via mod_proxy_uwsgi. This issue affects Apache HTTP Server: from 2.4.30 through 2.4.55.\n\nSpecial characters in the origin response header can truncate/split the response forwarded to the client.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-27522"
},
{
"cve": "CVE-2023-27534",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A path traversal vulnerability exists in curl \u003c8.0.0 SFTP implementation causes the tilde (~) character to be wrongly replaced when used as a prefix in the first path element, in addition to its intended use as the first element to indicate a path relative to the user\u0027s home directory. Attackers can exploit this flaw to bypass filtering or execute arbitrary code by crafting a path like /~2/foo while accessing a server with a specific user.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-27534"
},
{
"cve": "CVE-2023-27535",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An authentication bypass vulnerability exists in libcurl \u003c8.0.0 in the FTP connection reuse feature that can result in wrong credentials being used during subsequent transfers. Previously created connections are kept in a connection pool for reuse if they match the current setup. However, certain FTP settings such as CURLOPT_FTP_ACCOUNT, CURLOPT_FTP_ALTERNATIVE_TO_USER, CURLOPT_FTP_SSL_CCC, and CURLOPT_USE_SSL were not included in the configuration match checks, causing them to match too easily. This could lead to libcurl using the wrong credentials when performing a transfer, potentially allowing unauthorized access to sensitive information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-27535"
},
{
"cve": "CVE-2023-27536",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An authentication bypass vulnerability exists libcurl \u003c8.0.0 in the connection reuse feature which can reuse previously established connections with incorrect user permissions due to a failure to check for changes in the CURLOPT_GSSAPI_DELEGATION option. This vulnerability affects krb5/kerberos/negotiate/GSSAPI transfers and could potentially result in unauthorized access to sensitive information. The safest option is to not reuse connections if the CURLOPT_GSSAPI_DELEGATION option has been changed.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-27536"
},
{
"cve": "CVE-2023-28450",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in Dnsmasq before 2.90. The default maximum EDNS.0 UDP packet size was set to 4096 but should be 1232 because of DNS Flag Day 2020.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-28450"
},
{
"cve": "CVE-2023-28466",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "do_tls_getsockopt in net/tls/tls_main.c in the Linux kernel through 6.2.6 lacks a lock_sock call, leading to a race condition (with a resultant use-after-free or NULL pointer dereference).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-28466"
},
{
"cve": "CVE-2023-28486",
"cwe": {
"id": "CWE-116",
"name": "Improper Encoding or Escaping of Output"
},
"notes": [
{
"category": "summary",
"text": "Sudo before 1.9.13 does not escape control characters in log messages.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-28486"
},
{
"cve": "CVE-2023-28487",
"cwe": {
"id": "CWE-116",
"name": "Improper Encoding or Escaping of Output"
},
"notes": [
{
"category": "summary",
"text": "Sudo before 1.9.13 does not escape control characters in sudoreplay output.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-28487"
},
{
"cve": "CVE-2023-29402",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The go command may generate unexpected code at build time when using cgo. This may result in unexpected behavior when running a go program which uses cgo. This may occur when running an untrusted module which contains directories with newline characters in their names. Modules which are retrieved using the go command, i.e. via \"go get\", are not affected (modules retrieved using GOPATH-mode, i.e. GO111MODULE=off, may be affected).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-29402"
},
{
"cve": "CVE-2023-29404",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The go command may execute arbitrary code at build time when using cgo. This may occur when running \"go get\" on a malicious module, or when running any other command which builds untrusted code. This is can by triggered by linker flags, specified via a \"#cgo LDFLAGS\" directive. The arguments for a number of flags which are non-optional are incorrectly considered optional, allowing disallowed flags to be smuggled through the LDFLAGS sanitization. This affects usage of both the gc and gccgo compilers.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-29404"
},
{
"cve": "CVE-2023-29405",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The go command may execute arbitrary code at build time when using cgo. This may occur when running \"go get\" on a malicious module, or when running any other command which builds untrusted code. This is can by triggered by linker flags, specified via a \"#cgo LDFLAGS\" directive. Flags containing embedded spaces are mishandled, allowing disallowed flags to be smuggled through the LDFLAGS sanitization by including them in the argument of another flag. This only affects usage of the gccgo compiler.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-29405"
},
{
"cve": "CVE-2023-29406",
"cwe": {
"id": "CWE-436",
"name": "Interpretation Conflict"
},
"notes": [
{
"category": "summary",
"text": "The HTTP/1 client does not fully validate the contents of the Host header. A maliciously crafted Host header can inject additional headers or entire requests. With fix, the HTTP/1 client now refuses to send requests containing an invalid Request.Host or Request.URL.Host value.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-29406"
},
{
"cve": "CVE-2023-29409",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "Extremely large RSA keys in certificate chains can cause a client/server to expend significant CPU time verifying signatures. With fix, the size of RSA keys transmitted during handshakes is restricted to \u003c= 8192 bits. Based on a survey of publicly trusted RSA keys, there are currently only three certificates in circulation with keys larger than this, and all three appear to be test certificates that are not actively deployed. It is possible there are larger keys in use in private PKIs, but we target the web PKI, so causing breakage here in the interests of increasing the default safety of users of crypto/tls seems reasonable.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-29409"
},
{
"cve": "CVE-2023-30086",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Buffer Overflow vulnerability found in Libtiff V.4.0.7 allows a local attacker to cause a denial of service via the tiffcp function in tiffcp.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-30086"
},
{
"cve": "CVE-2023-30456",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in arch/x86/kvm/vmx/nested.c in the Linux kernel before 6.2.8. nVMX on x86_64 lacks consistency checks for CR0 and CR4.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-30456"
},
{
"cve": "CVE-2023-30772",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "The Linux kernel before 6.2.9 has a race condition and resultant use-after-free in drivers/power/supply/da9150-charger.c if a physically proximate attacker unplugs a device.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-30772"
},
{
"cve": "CVE-2023-31084",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in drivers/media/dvb-core/dvb_frontend.c in the Linux kernel 6.2. There is a blocking operation when a task is in !TASK_RUNNING. In dvb_frontend_get_event, wait_event_interruptible is called; the condition is dvb_frontend_test_event(fepriv,events). In dvb_frontend_test_event, down(\u0026fepriv-\u003esem) is called. However, wait_event_interruptible would put the process to sleep, and down(\u0026fepriv-\u003esem) may block the process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31084"
},
{
"cve": "CVE-2023-31124",
"cwe": {
"id": "CWE-330",
"name": "Use of Insufficiently Random Values"
},
"notes": [
{
"category": "summary",
"text": "c-ares is an asynchronous resolver library. When cross-compiling c-ares and using the autotools build system, CARES_RANDOM_FILE will not be set, as seen when cross compiling aarch64 android. This will downgrade to using rand() as a fallback which could allow an attacker to take advantage of the lack of entropy by not using a CSPRNG. This issue was patched in version 1.19.1.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31124"
},
{
"cve": "CVE-2023-31130",
"cwe": {
"id": "CWE-124",
"name": "Buffer Underwrite (\u0027Buffer Underflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "c-ares is an asynchronous resolver library. ares_inet_net_pton() is vulnerable to a buffer underflow for certain ipv6 addresses, in particular \"0::00:00:00/2\" was found to cause an issue. C-ares only uses this function internally for configuration purposes which would require an administrator to configure such an address via ares_set_sortlist(). However, users may externally use ares_inet_net_pton() for other purposes and thus be vulnerable to more severe issues. This issue has been fixed in 1.19.1.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31130"
},
{
"cve": "CVE-2023-31147",
"cwe": {
"id": "CWE-330",
"name": "Use of Insufficiently Random Values"
},
"notes": [
{
"category": "summary",
"text": "c-ares is an asynchronous resolver library. When /dev/urandom or RtlGenRandom() are unavailable, c-ares uses rand() to generate random numbers used for DNS query ids. This is not a CSPRNG, and it is also not seeded by srand() so will generate predictable output. Input from the random number generator is fed into a non-compilant RC4 implementation and may not be as strong as the original RC4 implementation. No attempt is made to look for modern OS-provided CSPRNGs like arc4random() that is widely available. This issue has been fixed in version 1.19.1.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31147"
},
{
"cve": "CVE-2023-31436",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "qfq_change_class in net/sched/sch_qfq.c in the Linux kernel before 6.2.13 allows an out-of-bounds write because lmax can exceed QFQ_MIN_LMAX.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31436"
},
{
"cve": "CVE-2023-31489",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An issue found in Frrouting bgpd v.8.4.2 allows a remote attacker to cause a denial of service via the bgp_capability_llgr() function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-31489"
},
{
"cve": "CVE-2023-32067",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "c-ares is an asynchronous resolver library. c-ares is vulnerable to denial of service. If a target resolver sends a query, the attacker forges a malformed UDP packet with a length of 0 and returns them to the target resolver. The target resolver erroneously interprets the 0 length as a graceful shutdown of the connection. This issue has been patched in version 1.19.1.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-32067"
},
{
"cve": "CVE-2023-32233",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "In the Linux kernel through 6.3.1, a use-after-free in Netfilter nf_tables when processing batch requests can be abused to perform arbitrary read and write operations on kernel memory. Unprivileged local users can obtain root privileges. This occurs because anonymous sets are mishandled.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-32233"
},
{
"cve": "CVE-2023-32573",
"cwe": {
"id": "CWE-369",
"name": "Divide By Zero"
},
"notes": [
{
"category": "summary",
"text": "In Qt before 5.15.14, 6.0.x through 6.2.x before 6.2.9, and 6.3.x through 6.5.x before 6.5.1, QtSvg QSvgFont m_unitsPerEm initialization is mishandled.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-32573"
},
{
"cve": "CVE-2023-33203",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The Linux kernel before 6.2.9 has a race condition and resultant use-after-free in drivers/net/ethernet/qualcomm/emac/emac.c if a physically proximate attacker unplugs an emac based device.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-33203"
},
{
"cve": "CVE-2023-34256",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "** DISPUTED ** An issue was discovered in the Linux kernel before 6.3.3. There is an out-of-bounds read in crc16 in lib/crc16.c when called from fs/ext4/super.c because ext4_group_desc_csum does not properly check an offset. NOTE: this is disputed by third parties because the kernel is not intended to defend against attackers with the stated \"When modifying the block device while it is mounted by the filesystem\" access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-34256"
},
{
"cve": "CVE-2023-34872",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Outline.cc for Poppler prior to 23.06.0 allows a remote attacker to cause a Denial of Service (DoS) (crash) via a crafted PDF file in OutlineItem::open.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-34872"
},
{
"cve": "CVE-2023-34969",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "D-Bus before 1.15.6 sometimes allows unprivileged users to crash dbus-daemon. If a privileged user with control over the dbus-daemon is using the org.freedesktop.DBus.Monitoring interface to monitor message bus traffic, then an unprivileged user with the ability to connect to the same dbus-daemon can cause a dbus-daemon crash under some circumstances via an unreplyable message. When done on the well-known system bus, this is a denial-of-service vulnerability. The fixed versions are 1.12.28, 1.14.8, and 1.15.6.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-34969"
},
{
"cve": "CVE-2023-35001",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Linux Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35001"
},
{
"cve": "CVE-2023-35788",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in fl_set_geneve_opt in net/sched/cls_flower.c in the Linux kernel before 6.3.7. It allows an out-of-bounds write in the flower classifier code via TCA_FLOWER_KEY_ENC_OPTS_GENEVE packets. This may result in denial of service or privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35788"
},
{
"cve": "CVE-2023-35789",
"cwe": {
"id": "CWE-522",
"name": "Insufficiently Protected Credentials"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the C AMQP client library (aka rabbitmq-c) through 0.13.0 for RabbitMQ. Credentials can only be entered on the command line (e.g., for amqp-publish or amqp-consume) and are thus visible to local attackers by listing a process and its arguments.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35789"
},
{
"cve": "CVE-2023-35823",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel before 6.3.2. A use-after-free was found in saa7134_finidev in drivers/media/pci/saa7134/saa7134-core.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35823"
},
{
"cve": "CVE-2023-35824",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel before 6.3.2. A use-after-free was found in dm1105_remove in drivers/media/pci/dm1105/dm1105.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35824"
},
{
"cve": "CVE-2023-35828",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel before 6.3.2. A use-after-free was found in renesas_usb3_remove in drivers/usb/gadget/udc/renesas_usb3.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-35828"
},
{
"cve": "CVE-2023-36054",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "lib/kadm5/kadm_rpc_xdr.c in MIT Kerberos 5 (aka krb5) before 1.20.2 and 1.21.x before 1.21.1 frees an uninitialized pointer. A remote authenticated user can trigger a kadmind crash. This occurs because _xdr_kadm5_principal_ent_rec does not validate the relationship between n_key_data and the key_data array count.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-36054"
},
{
"cve": "CVE-2023-36617",
"cwe": {
"id": "CWE-1333",
"name": "Inefficient Regular Expression Complexity"
},
"notes": [
{
"category": "summary",
"text": "A ReDoS issue was discovered in the URI component before 0.12.2 for Ruby. The URI parser mishandles invalid URLs that have specific characters. There is an increase in execution time for parsing strings to URI objects with rfc2396_parser.rb and rfc3986_parser.rb. NOTE: this issue exists becuse of an incomplete fix for CVE-2023-28755. Version 0.10.3 is also a fixed version.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-36617"
},
{
"cve": "CVE-2023-36664",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Artifex Ghostscript through 10.01.2 mishandles permission validation for pipe devices (with the %pipe% prefix or the | pipe character prefix).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-36664"
},
{
"cve": "CVE-2023-37920",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "summary",
"text": "Certifi is a curated collection of Root Certificates for validating the trustworthiness of SSL certificates while verifying the identity of TLS hosts. Certifi prior to version 2023.07.22 recognizes \"e-Tugra\" root certificates. e-Tugra\u0027s root certificates were subject to an investigation prompted by reporting of security issues in their systems. Certifi 2023.07.22 removes root certificates from \"e-Tugra\" from the root store.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-37920"
},
{
"cve": "CVE-2023-38559",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow flaw was found in base/gdevdevn.c:1973 in devn_pcx_write_rle() in ghostscript. This issue may allow a local attacker to cause a denial of service via outputting a crafted PDF file for a DEVN device with gs.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-38559"
},
{
"cve": "CVE-2023-40283",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in l2cap_sock_release in net/bluetooth/l2cap_sock.c in the Linux kernel before 6.4.10. There is a use-after-free because the children of an sk are mishandled.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
},
{
"category": "vendor_fix",
"details": "Update to V2.4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109826613/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0011",
"CSAFPID-0010",
"CSAFPID-0009",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0006"
]
}
],
"title": "CVE-2023-40283"
}
]
}
MSRC_CVE-2023-3776
Vulnerability from csaf_microsoft - Published: 2023-07-01 07:00 - Updated: 2023-08-01 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: 17823-16820 | — | ||
| Unresolved product id: 17824-17086 | — |
| URL | Category |
|---|---|
| https://msrc.microsoft.com/csaf/vex/2023/msrc_cve… | self |
| https://support.microsoft.com/lifecycle | external |
| https://www.first.org/cvss | external |
| https://msrc.microsoft.com/csaf/vex/2023/msrc_cve… | self |
{
"document": {
"category": "csaf_vex",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "To determine the support lifecycle for your software, see the Microsoft Support Lifecycle: https://support.microsoft.com/lifecycle",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The information provided in the Microsoft Knowledge Base is provided \\\"as is\\\" without warranty of any kind. Microsoft disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall Microsoft Corporation or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if Microsoft Corporation or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.",
"title": "Disclaimer"
}
],
"publisher": {
"category": "vendor",
"contact_details": "secure@microsoft.com",
"name": "Microsoft Security Response Center",
"namespace": "https://msrc.microsoft.com"
},
"references": [
{
"category": "self",
"summary": "CVE-2023-3776 Use-after-free in Linux kernel\u0027s net/sched: cls_fw component - VEX",
"url": "https://msrc.microsoft.com/csaf/vex/2023/msrc_cve-2023-3776.json"
},
{
"category": "external",
"summary": "Microsoft Support Lifecycle",
"url": "https://support.microsoft.com/lifecycle"
},
{
"category": "external",
"summary": "Common Vulnerability Scoring System",
"url": "https://www.first.org/cvss"
}
],
"title": "Use-after-free in Linux kernel\u0027s net/sched: cls_fw component",
"tracking": {
"current_release_date": "2023-08-01T00:00:00.000Z",
"generator": {
"date": "2025-12-27T16:55:11.572Z",
"engine": {
"name": "MSRC Generator",
"version": "1.0"
}
},
"id": "msrc_CVE-2023-3776",
"initial_release_date": "2023-07-01T07:00:00.000Z",
"revision_history": [
{
"date": "2023-08-01T00:00:00.000Z",
"legacy_version": "1",
"number": "1",
"summary": "Information published."
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "1.0",
"product": {
"name": "CBL Mariner 1.0",
"product_id": "16820"
}
},
{
"category": "product_version",
"name": "2.0",
"product": {
"name": "CBL Mariner 2.0",
"product_id": "17086"
}
}
],
"category": "product_name",
"name": "Azure Linux"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003ccm1 kernel 5.10.188.1-1",
"product": {
"name": "\u003ccm1 kernel 5.10.188.1-1",
"product_id": "2"
}
},
{
"category": "product_version",
"name": "cm1 kernel 5.10.188.1-1",
"product": {
"name": "cm1 kernel 5.10.188.1-1",
"product_id": "17823"
}
},
{
"category": "product_version_range",
"name": "\u003ccbl2 kernel 5.15.122.1-2",
"product": {
"name": "\u003ccbl2 kernel 5.15.122.1-2",
"product_id": "1"
}
},
{
"category": "product_version",
"name": "cbl2 kernel 5.15.122.1-2",
"product": {
"name": "cbl2 kernel 5.15.122.1-2",
"product_id": "17824"
}
}
],
"category": "product_name",
"name": "kernel"
}
],
"category": "vendor",
"name": "Microsoft"
}
],
"relationships": [
{
"category": "default_component_of",
"full_product_name": {
"name": "\u003ccm1 kernel 5.10.188.1-1 as a component of CBL Mariner 1.0",
"product_id": "16820-2"
},
"product_reference": "2",
"relates_to_product_reference": "16820"
},
{
"category": "default_component_of",
"full_product_name": {
"name": "cm1 kernel 5.10.188.1-1 as a component of CBL Mariner 1.0",
"product_id": "17823-16820"
},
"product_reference": "17823",
"relates_to_product_reference": "16820"
},
{
"category": "default_component_of",
"full_product_name": {
"name": "\u003ccbl2 kernel 5.15.122.1-2 as a component of CBL Mariner 2.0",
"product_id": "17086-1"
},
"product_reference": "1",
"relates_to_product_reference": "17086"
},
{
"category": "default_component_of",
"full_product_name": {
"name": "cbl2 kernel 5.15.122.1-2 as a component of CBL Mariner 2.0",
"product_id": "17824-17086"
},
"product_reference": "17824",
"relates_to_product_reference": "17086"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3776",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "general",
"text": "Google",
"title": "Assigning CNA"
}
],
"product_status": {
"fixed": [
"17823-16820",
"17824-17086"
],
"known_affected": [
"16820-2",
"17086-1"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2023-3776 Use-after-free in Linux kernel\u0027s net/sched: cls_fw component - VEX",
"url": "https://msrc.microsoft.com/csaf/vex/2023/msrc_cve-2023-3776.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"date": "2023-08-01T00:00:00.000Z",
"details": "5.10.188.1-1:Security Update:https://learn.microsoft.com/en-us/azure/azure-linux/tutorial-azure-linux-upgrade",
"product_ids": [
"16820-2"
],
"url": "https://learn.microsoft.com/en-us/azure/azure-linux/tutorial-azure-linux-upgrade"
},
{
"category": "vendor_fix",
"date": "2023-08-01T00:00:00.000Z",
"details": "5.15.122.1-2:Security Update:https://learn.microsoft.com/en-us/azure/azure-linux/tutorial-azure-linux-upgrade",
"product_ids": [
"17086-1"
],
"url": "https://learn.microsoft.com/en-us/azure/azure-linux/tutorial-azure-linux-upgrade"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalsScore": 0.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"16820-2",
"17086-1"
]
}
],
"title": "Use-after-free in Linux kernel\u0027s net/sched: cls_fw component"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.