CVE-2023-25018 (GCVE-0-2023-25018)
Vulnerability from cvelistv5 – Published: 2023-03-27 00:00 – Updated: 2025-02-19 15:51
VLAI
Title
Rifartek IOT Wall - Reflected XSS
Summary
RIFARTEK IOT Wall transportation function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can inject JavaScript to perform reflected XSS (Reflected Cross-site scripting) attack.
Severity
5.4 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
1 reference
Date Public
2023-02-24 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:11:44.185Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25018",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-19T15:50:53.748369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-19T15:51:13.502Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IOT Wall",
"vendor": "Rifartek",
"versions": [
{
"status": "affected",
"version": "22"
}
]
}
],
"datePublic": "2023-02-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "RIFARTEK IOT Wall transportation function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can inject JavaScript to perform reflected XSS (Reflected Cross-site scripting) attack."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-27T00:00:00.000Z",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"url": "https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update IOT Wall version to v30"
}
],
"source": {
"advisory": "TVN-202302014",
"discovery": "EXTERNAL"
},
"title": "Rifartek IOT Wall - Reflected XSS",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2023-25018",
"datePublished": "2023-03-27T00:00:00.000Z",
"dateReserved": "2023-02-02T00:00:00.000Z",
"dateUpdated": "2025-02-19T15:51:13.502Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-25018",
"date": "2026-05-27",
"epss": "0.00289",
"percentile": "0.52386"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-25018\",\"sourceIdentifier\":\"twcert@cert.org.tw\",\"published\":\"2023-03-27T04:15:10.390\",\"lastModified\":\"2024-11-21T07:48:56.560\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"RIFARTEK IOT Wall transportation function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can inject JavaScript to perform reflected XSS (Reflected Cross-site scripting) attack.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"twcert@cert.org.tw\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"twcert@cert.org.tw\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rifartek:iot_wall:22:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C3F367A9-A5D0-43B4-AFCE-1AA49D4C68AC\"}]}]}],\"references\":[{\"url\":\"https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html\",\"source\":\"twcert@cert.org.tw\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T11:11:44.185Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-25018\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-19T15:50:53.748369Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-19T15:51:08.017Z\"}}], \"cna\": {\"title\": \"Rifartek IOT Wall - Reflected XSS\", \"source\": {\"advisory\": \"TVN-202302014\", \"discovery\": \"EXTERNAL\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Rifartek\", \"product\": \"IOT Wall\", \"versions\": [{\"status\": \"affected\", \"version\": \"22\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update IOT Wall version to v30\"}], \"datePublic\": \"2023-02-24T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.twcert.org.tw/tw/cp-132-6963-7d2ee-1.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"RIFARTEK IOT Wall transportation function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can inject JavaScript to perform reflected XSS (Reflected Cross-site scripting) attack.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Cross-site Scripting (XSS)\"}]}], \"providerMetadata\": {\"orgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"shortName\": \"twcert\", \"dateUpdated\": \"2023-03-27T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-25018\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-19T15:51:13.502Z\", \"dateReserved\": \"2023-02-02T00:00:00.000Z\", \"assignerOrgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"datePublished\": \"2023-03-27T00:00:00.000Z\", \"assignerShortName\": \"twcert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…