CVE-2022-38744 (GCVE-0-2022-38744)

Vulnerability from cvelistv5 – Published: 2022-10-27 13:25 – Updated: 2025-05-05 15:38
VLAI
Title
FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack
Summary
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-05 15:38 UTC
CWE
  • CWE-287 - Improper Authentication
Impacted products
Date Public
2022-10-27 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38744",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-05T15:38:04.696478Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-05T15:38:28.146Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "FactoryTalk Alarm and Events Server",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2022-10-27T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAn unauthenticated attacker with network access to a victim\u0027s Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
            }
          ],
          "value": "\nAn unauthenticated attacker with network access to a victim\u0027s Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-528",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-528 XML Flood"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-27T13:25:17.957Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2022-38744",
    "datePublished": "2022-10-27T13:25:17.957Z",
    "dateReserved": "2022-08-24T22:11:22.158Z",
    "dateUpdated": "2025-05-05T15:38:28.146Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-38744",
      "date": "2026-09-20",
      "epss": "0.01164",
      "percentile": "0.65847"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "product": "FactoryTalk Alarm and Events Server",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "All"
                  }
                ]
              }
            ],
            "source": "PSIRT@rockwellautomation.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_alarms_and_events:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CCB45744-EA5E-47AF-B3F2-5E73FE108897",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nAn unauthenticated attacker with network access to a victim\u0027s Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
          },
          {
            "lang": "es",
            "value": "Un atacante no autenticado con acceso a la red de la v\u00edctima del servicio de Eventos y Alarmas FactoryTalk de Rockwell Automation podr\u00eda abrir una conexi\u00f3n, provocando que el servicio falle y deje de estar disponible. El puerto afectado podr\u00eda utilizarse como puerto de ping del servidor y utiliza mensajes estructurados con XML."
          }
        ],
        "id": "CVE-2022-38744",
        "lastModified": "2026-06-17T04:57:06.170",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-38744",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-05T15:38:04.696478Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2022-10-27T14:15:10.777",
        "references": [
          {
            "source": "PSIRT@rockwellautomation.com",
            "tags": [
              "Permissions Required",
              "Vendor Advisory"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Permissions Required",
              "Vendor Advisory"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
          }
        ],
        "sourceIdentifier": "PSIRT@rockwellautomation.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:57:29+00:00",
      "cve": "CVE-2022-38744",
      "id": "CVE-2022-38744",
      "initial_release_date": "2022-10-27T14:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-38744.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T11:02:14.533Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-38744",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-05T15:38:04.696478Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-05T15:38:20.480Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "FactoryTalk Alarm and Events Server",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "datePublic": "2022-10-27T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn unauthenticated attacker with network access to a victim\u0027s Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
                }
              ],
              "value": "\nAn unauthenticated attacker with network access to a victim\u0027s Rockwell Automation FactoryTalk Alarm and \nEvents service could open a connection, causing the service to fault and become unavailable. The affected port \ncould be used as a server ping port and uses messages structured with XML.\n\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-528",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-528 XML Flood"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-10-27T13:25:17.957Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1136876"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2022-38744",
        "datePublished": "2022-10-27T13:25:17.957Z",
        "dateReserved": "2022-08-24T22:11:22.158Z",
        "dateUpdated": "2025-05-05T15:38:28.146Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…