CVE-2022-22809 (GCVE-0-2022-22809)
Vulnerability from cvelistv5 – Published: 2022-02-09 00:00 – Updated: 2024-08-03 03:21- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) |
Affected:
spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.171Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-17T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-22809",
"datePublished": "2022-02-09T00:00:00.000Z",
"dateReserved": "2022-01-07T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:21:49.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-22809\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-02-09T23:15:19.293\",\"lastModified\":\"2024-11-21T06:47:29.373\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-306: Se presenta una vulnerabilidad de Falta de Autenticaci\u00f3n para la Funci\u00f3n Cr\u00edtica que podr\u00eda permitir una modificaci\u00f3n de las configuraciones t\u00e1ctiles de forma no autorizada cuando un atacante intenta modificar las configuraciones t\u00e1ctiles. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (versiones V2.6.2 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.6.2\",\"matchCriteriaId\":\"64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F7B2FBBD-C461-47EF-A912-E445C063DED9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.6.2\",\"matchCriteriaId\":\"BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EAF53585-8B87-4609-991E-30B56B601DEA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.6.2\",\"matchCriteriaId\":\"89174639-40D3-4A31-8357-7C497BCF2895\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC947F97-7E49-475F-84E6-29D7A6DF50CB\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
CVE-2022-22809
Vulnerability from csaf_se - Published: 2022-02-08 20:32 - Updated: 2022-03-08 20:32Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its spaceLYnk, Wiser For KNX, and fellerLYnk products.\r\nspaceLYnk is a centralized solution that reduces energy and maintenance costs, increases comfort and flexibility, and simplifies building management.\r\nWiser for KNX ,formerly known as homeLYnk, products are personalized energy efficiency solutions, offering a complete system based on open protocols: KNX, Modbus, BACnet and IP.\r\nfellerLYnk offers more flexibility in visualization and trend recording as well as functions such as presence simulation or time switches that the end customer can easily manage.\r\nFailure to apply the remediations provided below may risk a Cross-Site Request Forgery (CSRF), Missing Authentication, rate limit, or Stored Cross-Site Scripting (XSS) attack which could result in exfiltrated data and unauthorized access.\r\nMarch 2022 Update: The CVSS score has been updated for CVE-2022-22811 and CVE-2022-22812",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "spaceLYnk, Wiser For KNX, fellerLYnk - SEVD-2022-039-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"category": "self",
"summary": "spaceLYnk, Wiser For KNX, fellerLYnk - SEVD-2022-039-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-039-04.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "spaceLYnk, Wiser For KNX, fellerLYnk",
"tracking": {
"current_release_date": "2022-03-08T20:32:52.000Z",
"generator": {
"date": "2022-08-24T21:48:36.640Z",
"engine": {
"name": "Secvisogram",
"version": "1.14.0"
}
},
"id": "SEVD-2022-039-04",
"initial_release_date": "2022-02-08T20:32:52.000Z",
"revision_history": [
{
"date": "2022-02-08T20:32:52.000Z",
"number": "1.0.0",
"summary": "Original release"
},
{
"date": "2022-03-08T20:32:52.000Z",
"number": "1.1.0",
"summary": "March 2022 Update: The CVSS score has been updated for CVE-2022-22811 and CVE-2022-22812."
}
],
"status": "final",
"version": "1.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V2.6.2 ",
"product": {
"name": "Schneider Electric spaceLYnk V2.6.2 and prior",
"product_id": "1"
}
},
{
"category": "product_version",
"name": "2.7.0",
"product": {
"name": "Schneider Electric spaceLYnk 2.7.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "spaceLYnk"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V2.6.2",
"product": {
"name": "Schneider Electric Wiser for KNX (formerly homeLYnk) V2.6.2 and prior",
"product_id": "2"
}
},
{
"category": "product_version",
"name": "2.7.0",
"product": {
"name": "Schneider Electric Wiser for KNX (formerly homeLYnk) 2.7.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Wiser for KNX (formerly homeLYnk)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V2.6.2",
"product": {
"name": "Schneider Electric fellerLYnk V2.6.2 and prior",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "2.7.0",
"product": {
"name": "Schneider Electric fellerLYnk 2.7.0",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_version_range",
"name": "fellerLYnk"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-22809",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations."
}
],
"product_status": {
"fixed": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the spaceLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100200/spacelynk-logiccontroller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100200/spacelynk-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the Wiser for KNX product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100100/wiser-for-knxlogic-controller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100100/wiser-for-knx-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the fellerLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://onlinekatalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664\nA reboot is needed after installation",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://online-katalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should only be used in your personal home network. \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should not have a publicly accessible IP address. \u2022 Do NOT use port forwarding to access these products from the public internet. \u2022 These products should be on their own network segment. If your router supports a guest network or VLAN, it is preferable to locate the controller there. \u2022 Use the strongest Wi-Fi encryption available. \u2022 Use HTTPs in local network. \u2022 Only visit trusted websites.",
"product_ids": [
"1",
"2",
"3"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
]
},
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-22810",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"category": "description",
"text": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials."
}
],
"product_status": {
"fixed": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the spaceLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100200/spacelynk-logiccontroller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100200/spacelynk-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the Wiser for KNX product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100100/wiser-for-knxlogic-controller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100100/wiser-for-knx-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the fellerLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://onlinekatalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://online-katalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should only be used in your personal home network. \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should not have a publicly accessible IP address. \u2022 Do NOT use port forwarding to access these products from the public internet. \u2022 These products should be on their own network segment. If your router supports a guest network or VLAN, it is preferable to locate the controller there. \u2022 Use the strongest Wi-Fi encryption available. \u2022 Use HTTPs in local network. \u2022 Only visit trusted websites.",
"product_ids": [
"1",
"2",
"3"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
]
},
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-22811",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "description",
"text": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system\u2019s configurations when an attacker persuades a user to visit a rogue website"
}
],
"product_status": {
"fixed": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the spaceLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100200/spacelynk-logiccontroller/.\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100200/spacelynk-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the Wiser for KNX product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100100/wiser-for-knxlogic-controller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100100/wiser-for-knx-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the fellerLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://onlinekatalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://online-katalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should only be used in your personal home network. \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should not have a publicly accessible IP address. \u2022 Do NOT use port forwarding to access these products from the public internet. \u2022 These products should be on their own network segment. If your router supports a guest network or VLAN, it is preferable to locate the controller there. \u2022 Use the strongest Wi-Fi encryption available. \u2022 Use HTTPs in local network. \u2022 Only visit trusted websites.",
"product_ids": [
"1",
"2",
"3"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
]
},
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-22812",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser."
}
],
"product_status": {
"fixed": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the spaceLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100200/spacelynk-logiccontroller/.\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100200/spacelynk-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the Wiser for KNX product includes a fix for this vulnerability and is available for download here:\nhttps://www.se.com/ww/en/product/LSS100100/wiser-for-knxlogic-controller/\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product/LSS100100/wiser-for-knx-logic-controller/"
},
{
"category": "vendor_fix",
"details": "Version 2.7.0 of the fellerLYnk product includes a fix for this vulnerability and is available for download here:\nhttps://onlinekatalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664\nA reboot is needed after installation.",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://online-katalog.feller.ch/download/index.php?menueidLev1=279\u0026menueidLev2=662\u0026menueidLev3=664"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should only be used in your personal home network. \u2022 The homeLYnk, spaceLYnk, Wiser For KNX, fellerLYnk products should not have a publicly accessible IP address. \u2022 Do NOT use port forwarding to access these products from the public internet. \u2022 These products should be on their own network segment. If your router supports a guest network or VLAN, it is preferable to locate the controller there. \u2022 Use the strongest Wi-Fi encryption available. \u2022 Use HTTPs in local network. \u2022 Only visit trusted websites.",
"product_ids": [
"1",
"2",
"3"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
]
}
]
}
GSD-2022-22809
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-22809",
"description": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"id": "GSD-2022-22809"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-22809"
],
"details": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"id": "GSD-2022-22809",
"modified": "2023-12-13T01:19:28.805371Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"version": {
"version_data": [
{
"version_value": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22809"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
},
"lastModifiedDate": "2023-02-22T17:54Z",
"publishedDate": "2022-02-09T23:15Z"
}
}
}
GHSA-QRHR-2VCP-5JRH
Vulnerability from github – Published: 2022-02-11 00:00 – Updated: 2022-05-26 00:01A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
{
"affected": [],
"aliases": [
"CVE-2022-22809"
],
"database_specific": {
"cwe_ids": [
"CWE-306"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-02-09T23:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"id": "GHSA-qrhr-2vcp-5jrh",
"modified": "2022-05-26T00:01:09Z",
"published": "2022-02-11T00:00:48Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-22809"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"type": "WEB",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-expressway-filewrite-bsFVwueV"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"type": "CVSS_V3"
}
]
}
VAR-202202-0286
Vulnerability from variot - Updated: 2024-11-23 22:24A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior). spaceLYnk , Wiser for KNX ( Old homeLYnk) , fellerLYnk There is a vulnerability in the lack of authentication for critical features.Information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-0286",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wiser for knx",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "2.6.2"
},
{
"model": "fellerlynk",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "2.6.2"
},
{
"model": "spacelynk",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "2.6.2"
},
{
"model": "wiser for knx",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "fellerlynk",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "spacelynk",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"cve": "CVE-2022-22809",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2022-22809",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-411534",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-22809",
"impactScore": 1.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-22809",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-22809",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-22809",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-898",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-411534",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2022-22809",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior). spaceLYnk , Wiser for KNX ( Old homeLYnk) , fellerLYnk There is a vulnerability in the lack of authentication for critical features.Information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "VULMON",
"id": "CVE-2022-22809"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-22809",
"trust": 3.4
},
{
"db": "SCHNEIDER",
"id": "SEVD-2022-039-04",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-411534",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-22809",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"id": "VAR-202202-0286",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-411534"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T22:24:59.957000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2022-039-04",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"title": "Schneider Electric spaceLYnk Fixes for access control error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=182502"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/AlphabugX/CVE-2022-RCE "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.1
},
{
"problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-22809"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-expressway-filewrite-bsfvwuev"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/306.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-411534"
},
{
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-02-09T00:00:00",
"db": "VULHUB",
"id": "VHN-411534"
},
{
"date": "2022-02-09T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"date": "2023-05-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"date": "2022-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"date": "2022-02-09T23:15:19.293000",
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-02-22T00:00:00",
"db": "VULHUB",
"id": "VHN-411534"
},
{
"date": "2023-02-22T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22809"
},
{
"date": "2023-05-19T06:57:00",
"db": "JVNDB",
"id": "JVNDB-2022-005151"
},
{
"date": "2022-05-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-898"
},
{
"date": "2024-11-21T06:47:29.373000",
"db": "NVD",
"id": "CVE-2022-22809"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Schneider\u00a0Electric\u00a0 Vulnerability related to lack of authentication for critical functions in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-005151"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-898"
}
],
"trust": 0.6
}
}
CERTFR-2022-AVI-123
Vulnerability from certfr_avis - Published: 2022-02-09 - Updated: 2022-02-09
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
IGSS Data Server versions antérieures à V15.0.0.22021
EcoStruxure EV Charging Expert versions antérieures à V4.0.0.13 SP8 (Version 01)
Easergy P40 Series model numbers avec option Ethernet (produit ayant le code Q, R, S)
spaceLYnk versions antérieures à 2.7.0
Wiser for KNX product versions antérieures à 2.7.0
fellerLYnk product versions antérieures à 2.7.0
EcoStruxure Geo SCADA Expert versions antérieures à 2021
ClearSCADA versions antérieures à 2017 R3 August 2021 Monthly Update.
Harmony/Magelis iPC Series sans le correctif fourni avec Vijeo Designer version V6.2 SP11 Multi HotFix 4
Vijeo Designer versions antérieures à V6.2 SP11 Multi HotFix 4
Vijeo Designer Basic versions antérieures à v1.2.1
M241/M251 toutes versions
EcoStruxure Machine Expert toutes versions
Harmony/Magelis modèles HMISTU, HMIGTO, HMIGTU, HMIGTUX, HMIGK, HMISCU
Eurotherm E+PLC100 toutes versions
Eurotherm E+PLC400 toutes versions
Eurotherm E+PLC tools toutes versions
Easy Harmony ET6 (HMIET) sans le correctif fourni avec Vijeo Designer Basic version V1.2.1
Easy Harmony GXU (HMIGXU) sans le correctif fourni avec Vijeo Designer Basic version V1.2.1
Harmony/ Magelis modèles HMIGTU, HMIGTUX, HMIGK sans le correctif fourni avec Vijeo Designer version V6.2 SP11 Multi HotFix 4
Modicon M241/M251 Logic Controllers versions antérieures à V5.1.9.34
Modicon M262 Logic Controllers versions antérieures à V5.1.6.1
Easergy MiCOM P30 versions 660 -674
Easergy MiCOM P40 toutes versions
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cp\u003eIGSS Data Server versions ant\u00e9rieures \u00e0 V15.0.0.22021\u003cbr /\u003e EcoStruxure EV Charging Expert versions ant\u00e9rieures \u00e0 V4.0.0.13 SP8 (Version 01)\u003cbr /\u003e Easergy P40 Series model numbers avec option Ethernet (produit ayant le code Q, R, S)\u003cbr /\u003e spaceLYnk versions ant\u00e9rieures \u00e0 2.7.0\u003cbr /\u003e Wiser for KNX product versions ant\u00e9rieures \u00e0 2.7.0\u003cbr /\u003e fellerLYnk product versions ant\u00e9rieures \u00e0 2.7.0\u003cbr /\u003e EcoStruxure Geo SCADA Expert versions ant\u00e9rieures \u00e0 2021\u003cbr /\u003e ClearSCADA versions ant\u00e9rieures \u00e0 2017 R3 August 2021 Monthly Update.\u003cbr /\u003e Harmony/Magelis iPC Series sans le correctif fourni avec Vijeo Designer version V6.2 SP11 Multi HotFix 4\u003cbr /\u003e Vijeo Designer versions ant\u00e9rieures \u00e0 V6.2 SP11 Multi HotFix 4\u003cbr /\u003e Vijeo Designer Basic versions ant\u00e9rieures \u00e0 v1.2.1\u003cbr /\u003e M241/M251 toutes versions\u003cbr /\u003e EcoStruxure Machine Expert toutes versions\u003cbr /\u003e Harmony/Magelis mod\u00e8les HMISTU, HMIGTO, HMIGTU, HMIGTUX, HMIGK, HMISCU\u003cbr /\u003e Eurotherm E+PLC100 toutes versions\u003cbr /\u003e Eurotherm E+PLC400 toutes versions\u003cbr /\u003e Eurotherm E+PLC tools toutes versions\u003cbr /\u003e Easy Harmony ET6 (HMIET) sans le correctif fourni avec Vijeo Designer Basic version V1.2.1\u003cbr /\u003e Easy Harmony GXU (HMIGXU) sans le correctif fourni avec Vijeo Designer Basic version V1.2.1\u003cbr /\u003e Harmony/ Magelis mod\u00e8les HMIGTU, HMIGTUX, HMIGK sans le correctif fourni avec Vijeo Designer version V6.2 SP11 Multi HotFix 4\u003cbr /\u003e Modicon M241/M251 Logic Controllers versions ant\u00e9rieures \u00e0 V5.1.9.34\u003cbr /\u003e Modicon M262 Logic Controllers versions ant\u00e9rieures \u00e0 V5.1.6.1\u003cbr /\u003e Easergy MiCOM P30 versions 660 -674\u003cbr /\u003e Easergy MiCOM P40 toutes versions\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22817",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22817"
},
{
"name": "CVE-2022-22812",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22812"
},
{
"name": "CVE-2022-24312",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24312"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-24316",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24316"
},
{
"name": "CVE-2022-24314",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24314"
},
{
"name": "CVE-2022-24320",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24320"
},
{
"name": "CVE-2022-22811",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22811"
},
{
"name": "CVE-2022-24321",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24321"
},
{
"name": "CVE-2022-22810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22810"
},
{
"name": "CVE-2022-24310",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24310"
},
{
"name": "CVE-2022-24311",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24311"
},
{
"name": "CVE-2022-24318",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24318"
},
{
"name": "CVE-2022-22813",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22813"
},
{
"name": "CVE-2022-24313",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24313"
},
{
"name": "CVE-2022-24319",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24319"
},
{
"name": "CVE-2022-24315",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24315"
},
{
"name": "CVE-2022-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22809"
},
{
"name": "CVE-2022-22808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22808"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-24317",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24317"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2022-22807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22807"
}
],
"initial_release_date": "2022-02-09T00:00:00",
"last_revision_date": "2022-02-09T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-123",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-02-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0 distance et une\natteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-01 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-04 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-05 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-03 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-06 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-039-02 du 08 f\u00e9vrier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-02"
}
]
}
FKIE_CVE-2022-22809
Vulnerability from fkie_nvd - Published: 2022-02-09 23:15 - Updated: 2024-11-21 06:47| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04 | Patch, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAF53585-8B87-4609-991E-30B56B601DEA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "89174639-40D3-4A31-8357-7C497BCF2895",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC947F97-7E49-475F-84E6-29D7A6DF50CB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
},
{
"lang": "es",
"value": "Una CWE-306: Se presenta una vulnerabilidad de Falta de Autenticaci\u00f3n para la Funci\u00f3n Cr\u00edtica que podr\u00eda permitir una modificaci\u00f3n de las configuraciones t\u00e1ctiles de forma no autorizada cuando un atacante intenta modificar las configuraciones t\u00e1ctiles. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (versiones V2.6.2 y anteriores)"
}
],
"id": "CVE-2022-22809",
"lastModified": "2024-11-21T06:47:29.373",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-09T23:15:19.293",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.