CVE-2021-47708 (GCVE-0-2021-47708)
Vulnerability from cvelistv5 – Published: 2025-12-09 20:39 – Updated: 2026-07-15 01:24
VLAI
EPSS
VEX
Title
COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass
Summary
COMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the 'id' parameter in 'loginstart.asp'. Attackers can exploit this by sending a POST request with malicious 'id' values to manipulate database queries and gain unauthorized access.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-12-10 15:42 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/50207 | exploit |
| https://www.commax.com | product |
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | third-party-advisory |
| https://github.com/zeroscience | product |
| https://www.vulncheck.com/advisories/commax-smart… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| COMMAX Co., Ltd. | Smart Home IoT Control System |
Affected:
CDP-1020n
Affected: 481 System cpe:2.3:a:bosch:smart_home:cdp-1020n:*:*:*:*:iphone_os:*:* cpe:2.3:a:bosch:smart_home:481_system:*:*:*:*:iphone_os:*:* |
Date Public
2021-08-16 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47708",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-10T15:42:13.247736Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-10T15:42:30.747Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smart Home IoT Control System",
"vendor": "COMMAX Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "CDP-1020n"
},
{
"status": "affected",
"version": "481 System"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:smart_home:cdp-1020n:*:*:*:*:iphone_os:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:smart_home:481_system:*:*:*:*:iphone_os:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
}
],
"datePublic": "2021-08-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCOMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the \u0027id\u0027 parameter in \u0027loginstart.asp\u0027. Attackers can exploit this by sending a POST request with malicious \u0027id\u0027 values to manipulate database queries and gain unauthorized access.\u003c/p\u003e"
}
],
"value": "COMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the \u0027id\u0027 parameter in \u0027loginstart.asp\u0027. Attackers can exploit this by sending a POST request with malicious \u0027id\u0027 values to manipulate database queries and gain unauthorized access."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T01:24:34.159Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-50207",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/50207"
},
{
"name": "Official Product Homepage",
"tags": [
"product"
],
"url": "https://www.commax.com"
},
{
"name": "Zero Science Lab Disclosure (ZSL-2021-5662)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2021-5662.php"
},
{
"name": "Zero Science GitHub Repository",
"tags": [
"product"
],
"url": "https://github.com/zeroscience"
},
{
"name": "VulnCheck Advisory: COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/commax-smart-home-iot-control-system-sql-injection-authentication-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47708",
"datePublished": "2025-12-09T20:39:33.372Z",
"dateReserved": "2025-12-05T19:10:29.046Z",
"dateUpdated": "2026-07-15T01:24:34.159Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-47708",
"date": "2026-10-14",
"epss": "0.00528",
"percentile": "0.43324"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smart Home IoT Control System",
"vendor": "COMMAX Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "CDP-1020n"
},
{
"status": "affected",
"version": "481 System"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "COMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the \u0027id\u0027 parameter in \u0027loginstart.asp\u0027. Attackers can exploit this by sending a POST request with malicious \u0027id\u0027 values to manipulate database queries and gain unauthorized access."
}
],
"id": "CVE-2021-47708",
"lastModified": "2026-06-17T04:18:20.063",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-47708",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-10T15:42:13.247736Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-12-09T21:15:49.830",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://github.com/zeroscience"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.commax.com"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.exploit-db.com/exploits/50207"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/commax-smart-home-iot-control-system-sql-injection-authentication-bypass"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2021-5662.php"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-04-07T17:05:01+00:00",
"cve": "CVE-2021-47708",
"id": "CVE-2021-47708",
"initial_release_date": "2021-08-16T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-47708.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47708",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-10T15:42:13.247736Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-10T15:42:23.619Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smart Home IoT Control System",
"vendor": "COMMAX Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "CDP-1020n"
},
{
"status": "affected",
"version": "481 System"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCOMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the \u0027id\u0027 parameter in \u0027loginstart.asp\u0027. Attackers can exploit this by sending a POST request with malicious \u0027id\u0027 values to manipulate database queries and gain unauthorized access.\u003c/p\u003e"
}
],
"value": "COMMAX Smart Home System CDP-1020n contains an SQL injection vulnerability that allows attackers to bypass authentication by injecting arbitrary SQL code through the \u0027id\u0027 parameter in \u0027loginstart.asp\u0027. Attackers can exploit this by sending a POST request with malicious \u0027id\u0027 values to manipulate database queries and gain unauthorized access."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T20:39:33.372Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-50207",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/50207"
},
{
"name": "Official Product Homepage",
"tags": [
"product"
],
"url": "https://www.commax.com"
},
{
"name": "Zero Science Lab Disclosure (ZSL-2021-5662)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2021-5662.php"
},
{
"name": "Zero Science GitHub Repository",
"tags": [
"product"
],
"url": "https://github.com/zeroscience"
},
{
"name": "VulnCheck Advisory: COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/commax-smart-home-iot-control-system-sql-injection-authentication-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "COMMAX Smart Home IoT Control System SQL Injection Authentication Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47708",
"datePublished": "2025-12-09T20:39:33.372Z",
"dateReserved": "2025-12-05T19:10:29.046Z",
"dateUpdated": "2025-12-10T15:42:30.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.