CVE-2021-45975 (GCVE-0-2021-45975)

Vulnerability from cvelistv5 – Published: 2022-01-26 14:59 – Updated: 2024-08-04 04:54
VLAI
Summary
In ListCheck.exe in Acer Care Center 4.x before 4.00.3038, a vulnerability in the loading mechanism of Windows DLLs could allow a local attacker to perform a DLL hijacking attack. This vulnerability is due to incorrect handling of directory search paths at run time. An attacker could exploit this vulnerability by placing a malicious DLL file on the targeted system. This file will execute when the vulnerable application launches. A successful exploit could allow the attacker to execute arbitrary code on the targeted system with local administrator privileges.
CWE
  • n/a
Assigner
mitre CNA under the mitre root
CNA scorecard E 29/100 over 2158 records in the last 180 days details
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:54:31.090Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://acercsi.com"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In ListCheck.exe in Acer Care Center 4.x before 4.00.3038, a vulnerability in the loading mechanism of Windows DLLs could allow a local attacker to perform a DLL hijacking attack. This vulnerability is due to incorrect handling of directory search paths at run time. An attacker could exploit this vulnerability by placing a malicious DLL file on the targeted system. This file will execute when the vulnerable application launches. A successful exploit could allow the attacker to execute arbitrary code on the targeted system with local administrator privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-26T14:59:34.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://acercsi.com"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45975",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In ListCheck.exe in Acer Care Center 4.x before 4.00.3038, a vulnerability in the loading mechanism of Windows DLLs could allow a local attacker to perform a DLL hijacking attack. This vulnerability is due to incorrect handling of directory search paths at run time. An attacker could exploit this vulnerability by placing a malicious DLL file on the targeted system. This file will execute when the vulnerable application launches. A successful exploit could allow the attacker to execute arbitrary code on the targeted system with local administrator privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://acercsi.com",
              "refsource": "MISC",
              "url": "https://acercsi.com"
            },
            {
              "name": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability",
              "refsource": "MISC",
              "url": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability"
            },
            {
              "name": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html",
              "refsource": "MISC",
              "url": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45975",
    "datePublished": "2022-01-26T14:59:34.000Z",
    "dateReserved": "2022-01-01T00:00:00.000Z",
    "dateUpdated": "2024-08-04T04:54:31.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-45975",
      "date": "2026-11-12",
      "epss": "0.00604",
      "percentile": "0.49424"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:acer:care_center:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "169FE4FA-ACA9-44D7-9EB1-E338B98FF4D5",
                    "versionEndExcluding": "4.00.3038",
                    "versionStartIncluding": "4.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "In ListCheck.exe in Acer Care Center 4.x before 4.00.3038, a vulnerability in the loading mechanism of Windows DLLs could allow a local attacker to perform a DLL hijacking attack. This vulnerability is due to incorrect handling of directory search paths at run time. An attacker could exploit this vulnerability by placing a malicious DLL file on the targeted system. This file will execute when the vulnerable application launches. A successful exploit could allow the attacker to execute arbitrary code on the targeted system with local administrator privileges."
          },
          {
            "lang": "es",
            "value": "En el archivo ListCheck.exe de Acer Care Center versiones 4.x anteriores a 4.00.3038, una vulnerabilidad en el mecanismo de carga de DLL de Windows podr\u00eda permitir a un atacante local llevar a cabo un ataque de secuestro de DLL. Esta vulnerabilidad es debido al manejo incorrecto de las rutas de b\u00fasqueda de directorios en tiempo de ejecuci\u00f3n. Un atacante podr\u00eda explotar esta vulnerabilidad al colocar un archivo DLL malicioso en el sistema objetivo. Este archivo ser\u00e1 ejecutado cuando sea iniciada la aplicaci\u00f3n vulnerable. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo arbitrario en el sistema objetivo con privilegios de administrador local"
          }
        ],
        "id": "CVE-2021-45975",
        "lastModified": "2026-06-17T04:14:20.970",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.4,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2022-01-26T15:15:07.693",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Broken Link"
            ],
            "url": "https://acercsi.com"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link"
            ],
            "url": "https://acercsi.com"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://aptw.tf/2022/01/20/acer-care-center-privesc.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://community.acer.com/en/kb/articles/14757-acer-care-center-requires-an-update-to-resolve-a-security-vulnerability"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-426"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T13:13:33+00:00",
      "cve": "CVE-2021-45975",
      "id": "CVE-2021-45975",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-45975",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-45975.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.