CVE-2021-45658 (GCVE-0-2021-45658)
Vulnerability from cvelistv5 – Published: 2021-12-26 00:27 – Updated: 2024-08-04 04:47- n/a
| URL | Tags |
|---|---|
| https://kb.netgear.com/000064062/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:47:01.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:L/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-26T00:27:48.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-45658",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:L/A:N/C:H/I:H/PR:L/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125",
"refsource": "MISC",
"url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-45658",
"datePublished": "2021-12-26T00:27:48.000Z",
"dateReserved": "2021-12-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:47:01.959Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-45658",
"date": "2026-11-15",
"epss": "0.00847",
"percentile": "0.58645"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACEAC1F2-EEAE-4880-B6C0-FFAAA29685F1",
"versionEndExcluding": "1.0.1.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CFD91F26-5253-4A05-AB69-94CB2C416F83",
"versionEndExcluding": "1.0.0.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDB07B26-FD18-4023-A143-E890076FF68A",
"versionEndExcluding": "1.0.1.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5AC48A9A-9B6B-4E46-A022-958939EB2827",
"versionEndExcluding": "1.0.1.86",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5828F04B-E373-4E4F-942D-08CCA038418C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6100v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6C634416-8822-46D9-B6CA-DE71F4E2BFF1",
"versionEndExcluding": "1.0.1.86",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6100v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4DCFF79A-8ACE-455B-90F3-FFC745E8BAD4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6200v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "35673ECF-BC73-4B7D-9BFD-8A66A55C750A",
"versionEndExcluding": "1.0.1.78",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6200v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2141AE0A-18CB-4142-A850-B2153DAEE5A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7A3F4095-4746-4689-8190-13F2734493CC",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B7694D0C-2CC6-4A6E-A251-5CBFC67D2AA9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95F639EF-A599-4CC7-BDB1-5AF74560ADEB",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C63267D8-4632-4D14-B39C-BEEC62AD8F87",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6420_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A1C892CF-A183-45F0-AFEA-1448D93118AE",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6420:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0B2C00E1-4A23-4304-B92F-B7D9F4818D90",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6400v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "04F2925C-EF25-4162-8A3C-729191AC59D3",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6400v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5882095F-B22A-4937-BA08-6640140F10AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC45DE2E-BC27-4710-A237-1EFB4CD06299",
"versionEndExcluding": "1.0.2.144",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C515A99-8AC2-404F-BD64-9043C72EC4EC",
"versionEndExcluding": "1.0.2.144",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "568044B5-D287-4355-A375-E260F853AA03",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A1D4DF51-84EA-4296-9E06-CE5E1F4A53D1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7300v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A59D262F-1A53-4769-91B4-495217600D76",
"versionEndExcluding": "1.0.0.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7300v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0A88D2A3-3B22-4639-94E9-69CE80F37392",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C745B393-CC8D-4F88-A6EB-2788E1A4BAF9",
"versionEndExcluding": "1.0.3.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70E4DC5E-E34E-4AB1-BD50-F741142CB917",
"versionEndExcluding": "1.0.2.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "73ADA144-1E36-4F69-8C2D-2DD000F93361",
"versionEndExcluding": "1.0.5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A3A5762A-D32D-459B-B6CE-C54F8704BDEF",
"versionEndExcluding": "1.0.5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC0EC10D-5D3C-4C1F-83ED-24409A2F0F0E",
"versionEndExcluding": "1.0.1.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3DB57ABF-8ABA-47E0-974D-AF8DF696A968",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AE5AB36A-A020-4604-AB9B-55F114172D8D",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31604191-2A95-440D-B58B-84066805D623",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "87234D9C-235C-49CB-B88C-C2B84007387B",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70C4C62E-6B4C-4987-A6CA-07903E37EC34",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D5C3D18C-1CA3-4082-8F81-03BCE08F88B0",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EA2BB79-FBC6-45FB-B617-7EFCEE57DB73",
"versionEndExcluding": "2.5.1.16",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE",
"versionEndExcluding": "2.6.1.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*",
"matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA82BFA7-9B98-408C-BE81-E8D7532780A2",
"versionEndExcluding": "1.0.0.78",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29D544D2-5FF5-4C86-94A9-5562B277ABDC",
"versionEndExcluding": "1.0.2.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "37A3A395-4878-4026-8308-E83DFD66A781",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA9B22EF-5791-41DB-8CC1-A1B60CF4A73F",
"versionEndExcluding": "2.3.2.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5EAA7899-50E0-40CD-9CB9-877C48E4ED46",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by server-side injection. This affects D7800 before 1.0.1.58, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6100v2 before 1.0.1.86, EX6200v2 before 1.0.1.78, EX6250 before 1.0.0.110, EX6410 before 1.0.0.110, EX6420 before 1.0.0.110, EX6400v2 before 1.0.0.110, EX7300 before 1.0.2.144, EX6400 before 1.0.2.144, EX7320 before 1.0.0.110, EX7300v2 before 1.0.0.110, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.90, RBK40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, RBS50Y before 2.6.1.40, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.72, XR500 before 2.3.2.56, and XR700 before 1.0.1.20."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por la inyecci\u00f3n en el lado del servidor. Esto afecta al D7800 antes de 1.0.1.58, DM200 antes de 1.0.0.66, EX2700 antes de 1.0.1.56, EX6150v2 antes de 1.0.1.86, EX6100v2 antes de 1.0.1.86, EX6200v2 antes de 1.0.1.78, EX6250 antes de 1.0.0.110, EX6410 antes de 1.0.0.110, EX7300 antes de 1.0.0.110. 0.0.110, EX6420 antes de 1.0.0.110, EX6400v2 antes de 1.0.0.110, EX7300 antes de 1.0.2.144, EX6400 antes de 1.0.2.144, EX7320 antes de 1.0.0.110, EX7300v2 antes de 1.0.0.110, R7500v2 antes de 1.0.3.48, R7800 antes de 1. 0.2.68, R8900 antes de 1.0.5.2, R9000 antes de 1.0.5.2, RAX120 antes de 1.0.1.90, RBK40 antes de 2.5.1.16, RBK20 antes de 2.5.1.16, RBR20 antes de 2.5.1.16, RBS20 antes de 2.5.1.16, RBK50 antes de 2.5.1. 16, RBR50 antes de 2.5.1.16, RBS50 antes de 2.5.1.16, RBS50Y antes de 2.6.1.40, WN3000RPv2 antes de 1.0.0.78, WN3000RPv3 antes de 1.0.2.80, WNR2000v5 antes de 1.0.0.72, XR500 antes de 2.3.2.56 y XR700 antes de 1.0.1.20."
}
],
"id": "CVE-2021-45658",
"lastModified": "2026-06-17T04:13:53.100",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:20.467",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064062/Security-Advisory-for-Server-Side-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2019-0125"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-74"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T13:14:51+00:00",
"cve": "CVE-2021-45658",
"id": "CVE-2021-45658",
"initial_release_date": "2021-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2021-45658",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-45658.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.