CVE-2021-37915 (GCVE-0-2021-37915)

Vulnerability from cvelistv5 – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
VLAI
Summary
An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
CWE
  • n/a
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:30:09.022Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-28T11:11:28.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-37915",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
              "refsource": "MISC",
              "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
            },
            {
              "name": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf",
              "refsource": "MISC",
              "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
            },
            {
              "name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
              "refsource": "MISC",
              "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-37915",
    "datePublished": "2021-10-28T11:11:29.000Z",
    "dateReserved": "2021-08-02T00:00:00.000Z",
    "dateUpdated": "2024-08-04T01:30:09.022Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-37915",
      "date": "2026-09-26",
      "epss": "0.02029",
      "percentile": "0.80236"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2D52EBCB-68F7-476A-8290-56BA3327D324",
                    "versionEndExcluding": "1.0.29.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
          },
          {
            "lang": "es",
            "value": "Se ha detectado un problema en Grandstream HT801 Analog Telephone Adaptor versiones anteriores a 1.0.29.8. Desde el shell de configuraci\u00f3n limitada, es posible establecer la variable maliciosa gdb_debug_server. Como resultado, despu\u00e9s de un reinicio, el dispositivo descarga y ejecuta scripts maliciosos desde un host definido por el atacante"
          }
        ],
        "id": "CVE-2021-37915",
        "lastModified": "2024-11-21T06:16:02.890",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-10-28T12:15:08.477",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Broken Link"
            ],
            "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Product",
              "Vendor Advisory"
            ],
            "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link"
            ],
            "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Product",
              "Vendor Advisory"
            ],
            "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T13:44:04+00:00",
      "cve": "CVE-2021-37915",
      "id": "CVE-2021-37915",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-37915",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-37915.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…