CVE-2021-33542 (GCVE-0-2021-33542)
Vulnerability from cvelistv5 – Published: 2021-06-25 18:26 – Updated: 2024-09-17 01:31- CWE-824 - Access of Uninitialized Pointer
| URL | Tags |
|---|---|
| https://cert.vde.com/en-us/advisories/vde-2021-020 | x_refsource_CONFIRM |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Phoenix Contact | Automation Worx Software Suite |
Affected:
PC Worx , ≤ 1.87
(custom)
Affected: PC Worx Express , ≤ 1.87 (custom) Affected: Config+ , ≤ 1.87 (custom) |
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:50:43.120Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation Worx Software Suite",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThanOrEqual": "1.87",
"status": "affected",
"version": "PC Worx",
"versionType": "custom"
},
{
"lessThanOrEqual": "1.87",
"status": "affected",
"version": "PC Worx Express",
"versionType": "custom"
},
{
"lessThanOrEqual": "1.87",
"status": "affected",
"version": "Config+",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "The vulnerability was discovered by Francis Provencher {PRL} and reported by Zero Day Initiative (ZDI) as ZDI-CAN-13134. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"datePublic": "2021-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-07T09:06:35.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
}
],
"solutions": [
{
"lang": "en",
"value": "Temporary Fix / Mitigation\nWe strongly recommend customers to exchange project files only using secure file exchange services. Project files should not be exchanged via unencrypted email.\n\nRemediation\nWith the next version of Automationworx Software Suite the affected data will be initialized completely and thereby freeing of unallocated memory will be prevented."
}
],
"source": {
"advisory": "VDE-2021-020",
"defect": [
"VDE-2021-020"
],
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: Automation Worx Software Suite affected by Remote Code Execution (RCE) vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-06-23T10:00:00.000Z",
"ID": "CVE-2021-33542",
"STATE": "PUBLIC",
"TITLE": "Phoenix Contact: Automation Worx Software Suite affected by Remote Code Execution (RCE) vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation Worx Software Suite",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "PC Worx",
"version_value": "1.87"
},
{
"version_affected": "\u003c=",
"version_name": "PC Worx Express",
"version_value": "1.87"
},
{
"version_affected": "\u003c=",
"version_name": "Config+",
"version_value": "1.87"
}
]
}
}
]
},
"vendor_name": "Phoenix Contact"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "The vulnerability was discovered by Francis Provencher {PRL} and reported by Zero Day Initiative (ZDI) as ZDI-CAN-13134. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824 Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-020",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Temporary Fix / Mitigation\nWe strongly recommend customers to exchange project files only using secure file exchange services. Project files should not be exchanged via unencrypted email.\n\nRemediation\nWith the next version of Automationworx Software Suite the affected data will be initialized completely and thereby freeing of unallocated memory will be prevented."
}
],
"source": {
"advisory": "VDE-2021-020",
"defect": [
"VDE-2021-020"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-33542",
"datePublished": "2021-06-25T18:26:06.409Z",
"dateReserved": "2021-05-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:31:44.718Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-33542",
"date": "2026-11-25",
"epss": "0.01756",
"percentile": "0.7838"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0D2D0ACE-D2B7-4124-900B-0FBB0830563F",
"versionEndIncluding": "1.87",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
"matchCriteriaId": "73C5830F-A865-48CB-8DEE-126204CCF0C1",
"versionEndIncluding": "1.87",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
"matchCriteriaId": "613450E9-39B4-4D97-BB64-A3AE3B7ECCA9",
"versionEndIncluding": "1.87",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
},
{
"lang": "es",
"value": "Phoenix Contact Classic Automation Worx Software Suite en versiones 1.87 y anteriores, est\u00e1 afectado por una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo remota. La manipulaci\u00f3n de proyectos de PC Worx o Config+ podr\u00eda conllevar a una ejecuci\u00f3n de c\u00f3digo remota cuando es liberada una memoria no asignada debido a datos inicializados de forma incompleta. El atacante necesita conseguir acceso a un archivo de configuraci\u00f3n de bus original (*.bcp) para poder manipular los datos en su interior. Despu\u00e9s de la manipulaci\u00f3n, el atacante necesita intercambiar el archivo original por el manipulado en la estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones. La disponibilidad, la integridad o la confidencialidad de una estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones podr\u00eda estar comprometida por ataques usando estas vulnerabilidades. Los sistemas automatizados en funcionamiento que fueron programados con uno de los productos mencionados no est\u00e1n afectados"
}
],
"id": "CVE-2021-33542",
"lastModified": "2024-11-21T06:09:03.027",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 4.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.0,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-06-25T19:15:09.817",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
},
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-824"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-824"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T13:59:06+00:00",
"cve": "CVE-2021-33542",
"id": "CVE-2021-33542",
"initial_release_date": "2021-06-23T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Phoenix Contact: Automation Worx Software Suite affected by Remote Code Execution (RCE) vulnerability",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-33542.json",
"version": "3"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.