CVE-2021-26638 (GCVE-0-2021-26638)
Vulnerability from cvelistv5 – Published: 2022-06-22 13:55 – Updated: 2024-08-03 20:26
VLAI
Title
Xi Smarthome wallpad authentication bypass vulnerability
Summary
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
Severity
7.3 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.krcert.or.kr/krcert/secNoticeView.do?… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Xi S&D Inc. | S&D smarthome (smartcare) |
Affected:
unspecified , ≤ 3.2.48
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.500Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"Android"
],
"product": "S\u0026D smarthome (smartcare)",
"vendor": "Xi S\u0026D Inc.",
"versions": [
{
"lessThanOrEqual": "3.2.48",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Authentication vulnerability in S\u0026D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-22T13:55:59.000Z",
"orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"shortName": "krcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Xi Smarthome wallpad authentication bypass vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vuln@krcert.or.kr",
"ID": "CVE-2021-26638",
"STATE": "PUBLIC",
"TITLE": "Xi Smarthome wallpad authentication bypass vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "S\u0026D smarthome (smartcare)",
"version": {
"version_data": [
{
"platform": "Android",
"version_affected": "\u003c=",
"version_value": "3.2.48"
}
]
}
}
]
},
"vendor_name": "Xi S\u0026D Inc."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Authentication vulnerability in S\u0026D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783",
"refsource": "MISC",
"url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"assignerShortName": "krcert",
"cveId": "CVE-2021-26638",
"datePublished": "2022-06-22T13:55:59.000Z",
"dateReserved": "2021-02-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:26:25.500Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-26638",
"date": "2026-05-27",
"epss": "0.02264",
"percentile": "0.84852"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-26638\",\"sourceIdentifier\":\"vuln@krcert.or.kr\",\"published\":\"2022-06-23T17:15:11.280\",\"lastModified\":\"2024-11-21T05:56:38.573\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Authentication vulnerability in S\u0026D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de autenticaci\u00f3n inapropiada en la aplicaci\u00f3n S\u0026amp;D smarthome(smartcare) que puede causar una omisi\u00f3n de autenticaci\u00f3n y exposici\u00f3n de informaci\u00f3n. Los atacantes remotos pueden usar esta vulnerabilidad para tomar el control del entorno dom\u00e9stico, incluyendo el control interior\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vuln@krcert.or.kr\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.1,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"vuln@krcert.or.kr\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:xisnd:s\\\\\u0026d_smarthome:*:*:*:*:*:android:*:*\",\"versionEndIncluding\":\"3.2.48\",\"matchCriteriaId\":\"7F14E04B-6841-4ED0-803D-AFB8781ED608\"}]}]}],\"references\":[{\"url\":\"https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783\",\"source\":\"vuln@krcert.or.kr\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66783\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…