CVE-2021-23862 (GCVE-0-2021-23862)
Vulnerability from cvelistv5 – Published: 2021-12-08 21:17 – Updated: 2024-09-16 19:30- CWE-20 - Improper Input Validation
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/bosch… | x_refsource_CONFIRM |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Bosch | BVMS |
Affected:
unspecified , ≤ 9.0.0
(custom)
Affected: 11.0 , < 11.0.0 (custom) Affected: 10.0 , < 10.0.2 (custom) Affected: 10.1 , < 10.1.1 (custom) |
guessed | |
| Bosch | DIVAR IP 7000 R2 |
Affected:
all
|
guessed | |
| Bosch | DIVAR IP all-in-one 5000 |
Affected:
all
|
guessed | |
| Bosch | DIVAR IP all-in-one 7000 |
Affected:
all
|
guessed | |
| Bosch | VRM |
Affected:
unspecified , ≤ 3.81
(custom)
Affected: 4.0 , ≤ 4.00.0070 (custom) Affected: 3.83 , ≤ 3.83.0021 (custom) Affected: 3.82 , ≤ 3.82.0057 (custom) |
guessed | |
| Bosch | VJD-8000 |
Affected:
unspecified , ≤ 10.01.0036
(custom)
|
guessed | |
| Bosch | VJD-7513 |
Affected:
unspecified , ≤ 10.22.0038
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.805Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "9.0.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "11.0.0",
"status": "affected",
"version": "11.0",
"versionType": "custom"
},
{
"lessThan": "10.0.2",
"status": "affected",
"version": "10.0",
"versionType": "custom"
},
{
"lessThan": "10.1.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "VRM",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.00.0070",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.83.0021",
"status": "affected",
"version": "3.83",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.82.0057",
"status": "affected",
"version": "3.82",
"versionType": "custom"
}
]
},
{
"product": "VJD-8000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.01.0036",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.22.0038",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:17:37.000Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "UNKNOWN"
},
"title": "Authenticated Remote Code Execution",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-12-08",
"ID": "CVE-2021-23862",
"STATE": "PUBLIC",
"TITLE": "Authenticated Remote Code Execution"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BVMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.0",
"version_value": "11.0.0"
},
{
"version_affected": "\u003c",
"version_name": "10.0",
"version_value": "10.0.2"
},
{
"version_affected": "\u003c",
"version_name": "10.1",
"version_value": "10.1.1"
},
{
"version_affected": "\u003c=",
"version_value": "9.0.0"
}
]
}
},
{
"product_name": "DIVAR IP 7000 R2",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 7000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "VRM",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.0",
"version_value": "4.00.0070"
},
{
"version_affected": "\u003c=",
"version_name": "3.83",
"version_value": "3.83.0021"
},
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0057"
},
{
"version_affected": "\u003c=",
"version_value": "3.81"
}
]
}
},
{
"product_name": "VJD-8000",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "10.01.0036"
}
]
}
},
{
"product_name": "VJD-7513",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "10.22.0038"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000)."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23862",
"datePublished": "2021-12-08T21:17:37.519Z",
"dateReserved": "2021-01-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:30:25.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-23862",
"date": "2026-11-27",
"epss": "0.0144",
"percentile": "0.73445"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320",
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "989D5F9A-D223-4070-82AE-FA79E8B2572C",
"versionEndExcluding": "10.0.2",
"versionStartIncluding": "10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:10.1:*:*:*:*:*:*:*",
"matchCriteriaId": "57FA3EF2-6A7C-46FD-A758-92045A3A2DEE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1FF22168-E2A2-47B8-B9BC-104FF1CFDF30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D54B21E5-8C3E-423F-8E49-9F05B41D540B",
"versionEndIncluding": "3.81",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31D1E38A-C0F8-421B-B837-3D2FBD132A18",
"versionEndIncluding": "3.82.0057",
"versionStartIncluding": "3.82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7171D63A-3A1A-4235-9317-009D7C85A93C",
"versionEndIncluding": "3.83.0021",
"versionStartIncluding": "3.83",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31572EBA-C58A-46E8-88EA-ADE04578E039",
"versionEndIncluding": "4.00.0070",
"versionStartIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:divar_ip_5000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E2C1615D-2E5F-4D49-B937-05C81AB5414C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:bosch:divar_ip_7000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7CCD42BE-E4B7-43FC-95FB-C97704E5C268",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:videojet_decoder_7513_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC7D70DA-4C3A-4B37-B3E6-266B232FA117",
"versionEndIncluding": "10.22.0038",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:videojet_decoder_7513:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A96A7B0B-4C65-412E-8AB0-BD6098548598",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:videojet_decoder_8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C28B95FD-5932-4255-9AFE-85229C37C87D",
"versionEndIncluding": "10.01.0036",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:videojet_decoder_8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "028FEDCC-7774-4D17-B017-653365BE0297",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000)."
},
{
"lang": "es",
"value": "Un paquete de configuraci\u00f3n dise\u00f1ado enviado por un usuario administrativo autenticado puede ser usado para ejecutar comandos arbitrarios en el contexto del sistema. Este problema tambi\u00e9n afecta a las instalaciones de VRM, DIVAR IP, BVMS con VRM instalado, el decodificador VIDEOJET (VJD-7513 y VJD-8000)"
}
],
"id": "CVE-2021-23862",
"lastModified": "2024-11-21T05:51:58.453",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-08T22:15:08.607",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T14:45:21+00:00",
"cve": "CVE-2021-23862",
"id": "CVE-2021-23862",
"initial_release_date": "2021-12-08T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Authenticated Remote Code Execution",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-23862.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.