Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.
Severity ?
6.1 (Medium)
CWE
- CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.40.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.581Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000189193"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.40.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-06-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-03T15:30:20",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000189193"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-06-30",
"ID": "CVE-2021-21578",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.40.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.1,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000189193",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000189193"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21578",
"datePublished": "2021-08-03T15:30:20.317411Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T23:20:26.805Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-21578\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-08-03T16:15:07.953\",\"lastModified\":\"2024-11-21T05:48:38.550\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.\"},{\"lang\":\"es\",\"value\":\"Dell EMC iDRAC9 versiones anteriores a 4.40.40.00 contienen una vulnerabilidad de redireccionamiento abierto. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para redirigir a usuarios a URLs web arbitrarias al enga\u00f1ar a usuarios v\u00edctimas para que hagan clic enlaces maliciosamente dise\u00f1ados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_idrac9_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.40.40.00\",\"matchCriteriaId\":\"8677A5D5-756F-411F-B0D7-2E06105F3B56\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…