Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-7496 (GCVE-0-2020-7496)
Vulnerability from cvelistv5 – Published: 2020-06-16 19:13 – Updated: 2024-08-04 09:33- CWE-88 - Argument Injection or Modification
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) |
Affected:
EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.584Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-88",
"description": "CWE-88: Argument Injection or Modification",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-16T19:13:29.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7496",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-88: Argument Injection or Modification"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7496",
"datePublished": "2020-06-16T19:13:29.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-7496",
"date": "2026-05-17",
"epss": "0.00268",
"percentile": "0.50274"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7496\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-06-16T20:15:14.537\",\"lastModified\":\"2024-11-21T05:37:15.570\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.\"},{\"lang\":\"es\",\"value\":\"Una CWE-88: Se presenta una vulnerabilidad de Inyecci\u00f3n de Argumentos o Modificaci\u00f3n en EcoStruxure Operator Terminal Expert versiones 3.1, Service Pack 1 y anteriores (anteriormente conocido como Vijeo XD) que podr\u00eda causar un acceso de escritura no autorizado cuando se abre el archivo del proyecto\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-88\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-88\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:se:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.0\",\"matchCriteriaId\":\"D3A5586F-7936-4688-8F89-8CDF9ED82188\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"01632EE4-278F-4002-9147-1257FC934152\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"063E73FF-C561-4A6C-B869-23BD60798BF0\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-133-04\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-133-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
ICSA-20-142-02
Vulnerability from csaf_cisa - Published: 2020-05-21 00:00 - Updated: 2020-05-21 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)
Schneider Electric Software, LLC / EcoStruxure Operator Terminal Expert 3.1
|
3.1 SP1 |
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)
Schneider Electric Software, LLC / EcoStruxure Operator Terminal Expert 3.1
|
3.1 SP1 |
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)
Schneider Electric Software, LLC / EcoStruxure Operator Terminal Expert 3.1
|
3.1 SP1 |
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)
Schneider Electric Software, LLC / EcoStruxure Operator Terminal Expert 3.1
|
3.1 SP1 |
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)
Schneider Electric Software, LLC / EcoStruxure Operator Terminal Expert 3.1
|
3.1 SP1 |
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"Sharon Brizinov",
"Amir Preminger"
],
"organization": "Claroty",
"summary": "reporting these vulnerabilities to Schneider Electric"
},
{
"organization": "Trend Micro\u2019s Zero Day Initiative",
"summary": "reporting these vulnerabilities to Schneider Electric"
},
{
"names": [
"Steven Seeley",
"Chris Anastasio"
],
"organization": "Incite Team",
"summary": "reporting these vulnerabilities to Schneider Electric"
},
{
"names": [
"Fredrik \u00d8strem",
"Emil Sandst\u00f8",
"Cim Stordal"
],
"organization": "Cognite",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow unauthorized write access or remote code execution.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "These vulnerabilities are not exploitable remotely.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-142-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-142-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-142-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-142-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure Operator Terminal Expert",
"tracking": {
"current_release_date": "2020-05-21T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-142-02",
"initial_release_date": "2020-05-21T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-05-21T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-142-02 Schneider Electric EcoStruxure Operator Terminal Expert"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "3.1 SP1",
"product": {
"name": "EcoStruxure Operator Terminal Expert 3.1: Service Pack 1 and prior (formerly known as Vijeo XD)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure Operator Terminal Expert 3.1"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7493",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker could exploit an SQL injection vulnerability by enticing a user to open a maliciously crafted project file.CVE-2020-7493 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7493"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users update to EcoStruxure Operator Terminal Expert Version 3.1 Service Pack 1A. Schneider Electric offers two methods to get the update",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not execute EcoStruxure Operator Terminal Expert software with Windows administrator privileges.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application whitelisting software, etc.) and secure network using Schneider Electric\u0027s Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Manage your project file securely to avoid information disclosure or unexpected modifications of data.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only accept project files from trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Use project password when saving the project file.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "User\u0027s password in the application should be configured as a strong password according with the \u201cuse complex password\u201d function described in the section titled \u201cSecurity / Settings / use complex password.\u201d",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and updates, please see SEVD-2020-133-04",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7494",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker could exploit this path traversal vulnerability by getting a user to visit a malicious page or open a malicious file.CVE-2020-7494 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7494"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users update to EcoStruxure Operator Terminal Expert Version 3.1 Service Pack 1A. Schneider Electric offers two methods to get the update",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not execute EcoStruxure Operator Terminal Expert software with Windows administrator privileges.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application whitelisting software, etc.) and secure network using Schneider Electric\u0027s Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Manage your project file securely to avoid information disclosure or unexpected modifications of data.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only accept project files from trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Use project password when saving the project file.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "User\u0027s password in the application should be configured as a strong password according with the \u201cuse complex password\u201d function described in the section titled \u201cSecurity / Settings / use complex password.\u201d",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and updates, please see SEVD-2020-133-04",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7495",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker could exploit this path traversal vulnerability by getting a user to visit a malicious page or open a malicious file.CVE-2020-7495 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7495"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users update to EcoStruxure Operator Terminal Expert Version 3.1 Service Pack 1A. Schneider Electric offers two methods to get the update",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not execute EcoStruxure Operator Terminal Expert software with Windows administrator privileges.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application whitelisting software, etc.) and secure network using Schneider Electric\u0027s Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Manage your project file securely to avoid information disclosure or unexpected modifications of data.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only accept project files from trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Use project password when saving the project file.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "User\u0027s password in the application should be configured as a strong password according with the \u201cuse complex password\u201d function described in the section titled \u201cSecurity / Settings / use complex password.\u201d",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and updates, please see SEVD-2020-133-04",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7496",
"cwe": {
"id": "CWE-88",
"name": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A remote attacker can trick a victim to open a specially crafted project file and gain unauthorized write access to the target system.CVE-2020-7496 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7496"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users update to EcoStruxure Operator Terminal Expert Version 3.1 Service Pack 1A. Schneider Electric offers two methods to get the update",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not execute EcoStruxure Operator Terminal Expert software with Windows administrator privileges.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application whitelisting software, etc.) and secure network using Schneider Electric\u0027s Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Manage your project file securely to avoid information disclosure or unexpected modifications of data.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only accept project files from trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Use project password when saving the project file.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "User\u0027s password in the application should be configured as a strong password according with the \u201cuse complex password\u201d function described in the section titled \u201cSecurity / Settings / use complex password.\u201d",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and updates, please see SEVD-2020-133-04",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7497",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists that could cause arbitrary application execution when the computer starts.CVE-2020-7497 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7497"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users update to EcoStruxure Operator Terminal Expert Version 3.1 Service Pack 1A. Schneider Electric offers two methods to get the update",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not execute EcoStruxure Operator Terminal Expert software with Windows administrator privileges.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application whitelisting software, etc.) and secure network using Schneider Electric\u0027s Cybersecurity Best Practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Manage your project file securely to avoid information disclosure or unexpected modifications of data.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only accept project files from trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Use project password when saving the project file.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "User\u0027s password in the application should be configured as a strong password according with the \u201cuse complex password\u201d function described in the section titled \u201cSecurity / Settings / use complex password.\u201d",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and updates, please see SEVD-2020-133-04",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
FKIE_CVE-2020-7496
Vulnerability from fkie_nvd - Published: 2020-06-16 20:15 - Updated: 2024-11-21 05:37| Vendor | Product | Version | |
|---|---|---|---|
| se | ecostruxure_operator_terminal_expert | * | |
| se | ecostruxure_operator_terminal_expert | 3.1 | |
| se | ecostruxure_operator_terminal_expert | 3.1 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D3A5586F-7936-4688-8F89-8CDF9ED82188",
"versionEndIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "01632EE4-278F-4002-9147-1257FC934152",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:sp1:*:*:*:*:*:*",
"matchCriteriaId": "063E73FF-C561-4A6C-B869-23BD60798BF0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
},
{
"lang": "es",
"value": "Una CWE-88: Se presenta una vulnerabilidad de Inyecci\u00f3n de Argumentos o Modificaci\u00f3n en EcoStruxure Operator Terminal Expert versiones 3.1, Service Pack 1 y anteriores (anteriormente conocido como Vijeo XD) que podr\u00eda causar un acceso de escritura no autorizado cuando se abre el archivo del proyecto"
}
],
"id": "CVE-2020-7496",
"lastModified": "2024-11-21T05:37:15.570",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-16T20:15:14.537",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-88"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-88"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CERTFR-2020-AVI-316
Vulnerability from certfr_avis - Published: 2020-05-25 - Updated: 2020-05-25
De multiples vulnérabilités ont été découvertes dans Schneider EcoStruxure Operator Terminal. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Operator Terminal Expert versions ant\u00e9rieures \u00e0 3.1 Service Pack 1A",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7495",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7495"
},
{
"name": "CVE-2020-7497",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7497"
},
{
"name": "CVE-2020-7494",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7494"
},
{
"name": "CVE-2020-7493",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7493"
},
{
"name": "CVE-2020-7496",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7496"
}
],
"initial_release_date": "2020-05-25T00:00:00",
"last_revision_date": "2020-05-25T00:00:00",
"links": [],
"reference": "CERTFR-2020-AVI-316",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-05-25T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Schneider\nEcoStruxure Operator Terminal. Elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance et une atteinte \u00e0\nl\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans Schneider EcoStruxure Operator Terminal",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-133-04 du 12 mai 2020",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-04_EcoStruxure%E2%84%A2+Operator+Terminal+Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2020-133-04"
}
]
}
CNVD-2020-30438
Vulnerability from cnvd - Published: 2020-05-28厂商已发布了漏洞修复程序,请及时关注更新: https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab
| Name | Schneider Electric EcoStruxure Operator Terminal Expert <=3.1 SP1 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-7496"
}
},
"description": "Schneider Electric EcoStruxure Operator Terminal Expert\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u89e6\u63a7\u5c4f\u914d\u7f6e\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u652f\u4e3b\u8981\u7528\u4e8e\u521b\u5efa\u548c\u7f16\u8f91\u89e6\u63a7\u5e94\u7528\u7a0b\u5e8f\u3002\n\nSchneider Electric EcoStruxure Operator Terminal Expert\u5b58\u5728\u53c2\u6570\u6ce8\u5165\u6f0f\u6d1e\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u5bf9\u76ee\u6807\u7cfb\u7edf\u7684\u672a\u7ecf\u6388\u6743\u7684\u5199\u8bbf\u95ee\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-30438",
"openTime": "2020-05-28",
"patchDescription": "Schneider Electric EcoStruxure Operator Terminal Expert\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u89e6\u63a7\u5c4f\u914d\u7f6e\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u652f\u4e3b\u8981\u7528\u4e8e\u521b\u5efa\u548c\u7f16\u8f91\u89e6\u63a7\u5e94\u7528\u7a0b\u5e8f\u3002\r\n\r\nSchneider Electric EcoStruxure Operator Terminal Expert\u5b58\u5728\u53c2\u6570\u6ce8\u5165\u6f0f\u6d1e\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u5bf9\u76ee\u6807\u7cfb\u7edf\u7684\u672a\u7ecf\u6388\u6743\u7684\u5199\u8bbf\u95ee\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric EcoStruxure Operator Terminal Expert\u53c2\u6570\u6ce8\u5165\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric EcoStruxure Operator Terminal Expert \u003c=3.1 SP1"
},
"referenceLink": "https://www.us-cert.gov/ics/advisories/icsa-20-142-02",
"serverity": "\u4f4e",
"submitTime": "2020-05-22",
"title": "Schneider Electric EcoStruxure Operator Terminal Expert\u53c2\u6570\u6ce8\u5165\u6f0f\u6d1e"
}
GHSA-WCX9-VC6G-982M
Vulnerability from github – Published: 2022-05-24 17:20 – Updated: 2022-05-24 17:20A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.
{
"affected": [],
"aliases": [
"CVE-2020-7496"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-06-16T20:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.",
"id": "GHSA-wcx9-vc6g-982m",
"modified": "2022-05-24T17:20:39Z",
"published": "2022-05-24T17:20:39Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7496"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2020-7496
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7496",
"description": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.",
"id": "GSD-2020-7496"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7496"
],
"details": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.",
"id": "GSD-2020-7496",
"modified": "2023-12-13T01:21:51.503297Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7496",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-88: Argument Injection or Modification"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:se:ecostruxure_operator_terminal_expert:3.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7496"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-88"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2020-06-18T19:58Z",
"publishedDate": "2020-06-16T20:15Z"
}
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.