CVE-2020-5761 (GCVE-0-2020-5761)

Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
CWE
Assigner
tenable CNA under the mitre root
CNA scorecard C 71/100 over 52 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:39:25.699Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-43"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-47"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Grandstream HT800 Series",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.0.17.5 and below"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-835",
              "description": "CWE-835",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-29T19:06:10.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-43"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-47"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2020-5761",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Grandstream HT800 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 1.0.17.5 and below"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-835"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2020-43",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "name": "https://www.tenable.com/security/research/tra-2020-47",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2020-5761",
    "datePublished": "2020-07-29T18:51:43.000Z",
    "dateReserved": "2020-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:39:25.699Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-5761",
      "date": "2026-10-16",
      "epss": "0.04093",
      "percentile": "0.90601"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "10C6AE2E-DCBA-471E-AC05-D04021F625CE",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht802_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1EE48BC4-31F0-4D94-9A1E-C0E83776FDF4",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht812_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CF548C51-32DF-4365-9C36-CE1FE17AC207",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht812:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AC0A2572-951D-4384-AF93-D674F3E07788",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht814_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "59773485-3A12-477B-BF83-C1E0E8C979AD",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht814:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE769C28-17BB-4570-8239-6393239BE542",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht818_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0CBC4277-2D62-4C60-A638-851BB92B9A67",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht818:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "35BEAB2F-5673-42EC-BA4F-982226C1CB7E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:grandstream:ht813_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C9E5F102-13D3-47A4-926A-4B67E0742E82",
                    "versionEndIncluding": "1.0.17.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:grandstream:ht813:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "76348549-9B8E-4E80-854F-8F8886C6BA59",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
          },
          {
            "lang": "es",
            "value": "Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es vulnerable a un agotamiento del CPU debido a un bucle infinito en el servicio TR-069. Los atacantes remotos no autenticados pueden activar este caso mediante el env\u00edo de un mensaje TCP de un car\u00e1cter hacia el servicio TR-069"
          }
        ],
        "id": "CVE-2020-5761",
        "lastModified": "2024-11-21T05:34:33.363",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-07-29T19:15:15.047",
        "references": [
          {
            "source": "vulnreport@tenable.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-43"
          },
          {
            "source": "vulnreport@tenable.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-47"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-43"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-47"
          }
        ],
        "sourceIdentifier": "vulnreport@tenable.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-835"
              }
            ],
            "source": "vulnreport@tenable.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-835"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-22T15:39:54+00:00",
      "cve": "CVE-2020-5761",
      "id": "CVE-2020-5761",
      "initial_release_date": "2020-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2020-5761",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2020/cve-2020-5761.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.