CVE-2020-24051 (GCVE-0-2020-24051)
Vulnerability from cvelistv5 – Published: 2020-08-21 14:23 – Updated: 2024-08-04 15:05
VLAI
EPSS
VEX
Summary
The Moog EXO Series EXVF5C-2 and EXVP7C2-3 units support the ONVIF interoperability IP-based physical security protocol, which requires authentication for some of its operations. It was found that the authentication check for those ONVIF operations can be bypassed. An attacker can abuse this issue to execute privileged operations without authentication, for instance, to create a new Administrator user.
Severity
9.8 (Critical)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://ioactive.com/moog-exo-series-multiple-vul… | x_refsource_MISC |
| https://ioac.tv/3hy1xu6 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:05:11.844Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ioactive.com/moog-exo-series-multiple-vulnerabilities/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ioac.tv/3hy1xu6"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Moog EXO Series EXVF5C-2 and EXVP7C2-3 units support the ONVIF interoperability IP-based physical security protocol, which requires authentication for some of its operations. It was found that the authentication check for those ONVIF operations can be bypassed. An attacker can abuse this issue to execute privileged operations without authentication, for instance, to create a new Administrator user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-21T14:23:54.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ioactive.com/moog-exo-series-multiple-vulnerabilities/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ioac.tv/3hy1xu6"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24051",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Moog EXO Series EXVF5C-2 and EXVP7C2-3 units support the ONVIF interoperability IP-based physical security protocol, which requires authentication for some of its operations. It was found that the authentication check for those ONVIF operations can be bypassed. An attacker can abuse this issue to execute privileged operations without authentication, for instance, to create a new Administrator user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ioactive.com/moog-exo-series-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://ioactive.com/moog-exo-series-multiple-vulnerabilities/"
},
{
"name": "https://ioac.tv/3hy1xu6",
"refsource": "MISC",
"url": "https://ioac.tv/3hy1xu6"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-24051",
"datePublished": "2020-08-21T14:23:54.000Z",
"dateReserved": "2020-08-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:05:11.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-24051",
"date": "2026-07-16",
"epss": "0.02218",
"percentile": "0.80659"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-24051\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-08-21T15:15:12.773\",\"lastModified\":\"2024-11-21T05:14:21.457\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Moog EXO Series EXVF5C-2 and EXVP7C2-3 units support the ONVIF interoperability IP-based physical security protocol, which requires authentication for some of its operations. It was found that the authentication check for those ONVIF operations can be bypassed. An attacker can abuse this issue to execute privileged operations without authentication, for instance, to create a new Administrator user.\"},{\"lang\":\"es\",\"value\":\"Las unidades EXVF5C-2 y EXVP7C2-3 de la Serie Moog EXO, admiten el protocolo de seguridad f\u00edsica basado en IP de interoperabilidad ONVIF, que requiere autenticaci\u00f3n para algunas de sus operaciones. Se encontr\u00f3 que la comprobaci\u00f3n de autenticaci\u00f3n para esas operaciones ONVIF puede ser omitida. Un atacante puede abusar de este problema para ejecutar operaciones privilegiadas sin autenticaci\u00f3n, por ejemplo, para crear un nuevo usuario Administrador.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moog:exvf5c-2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF20FE0F-EDB8-4BA4-A3B3-D141F2B01541\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moog:exvf5c-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"69235D77-74E9-4D65-BB46-83BE55DDCCD8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moog:exvp7c2-3_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D6F1521A-7795-438F-9EBD-8C866A856FAA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moog:exvp7c2-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5DDBEF0A-717F-4564-A05D-17164EA6D6AA\"}]}]}],\"references\":[{\"url\":\"https://ioac.tv/3hy1xu6\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://ioactive.com/moog-exo-series-multiple-vulnerabilities/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://ioac.tv/3hy1xu6\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://ioactive.com/moog-exo-series-multiple-vulnerabilities/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…