CVE-2020-14489 (GCVE-0-2020-14489)

Vulnerability from cvelistv5 – Published: 2020-07-29 12:24 – Updated: 2024-09-17 01:46
VLAI
Title
OpenClinic GA
Summary
OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques.
CWE
  • CWE-522 - INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 342 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
open source OpenClinic GA Affected: 5.09.02
Affected: 5.89.05b
guessed Create a notification for this product.
Date Public
2020-07-02 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.569Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenClinic GA",
          "vendor": "open source",
          "versions": [
            {
              "status": "affected",
              "version": "5.09.02"
            },
            {
              "status": "affected",
              "version": "5.89.05b"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Brian D. Hysell reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2020-07-02T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-29T12:24:11.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01"
        }
      ],
      "source": {
        "advisory": "ICSMA-20-184-01 OpenClinic GA",
        "discovery": "EXTERNAL"
      },
      "title": "OpenClinic GA",
      "workarounds": [
        {
          "lang": "en",
          "value": "OpenClinic GA is aware of these vulnerabilities but has not provided any confirmation of their resolution. Please upgrade to the latest version to ensure you have all current fixes."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-02T00:00:00.000Z",
          "ID": "CVE-2020-14489",
          "STATE": "PUBLIC",
          "TITLE": "OpenClinic GA"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OpenClinic GA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.09.02"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "5.89.05b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "open source"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Brian D. Hysell reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01"
            }
          ]
        },
        "source": {
          "advisory": "ICSMA-20-184-01 OpenClinic GA",
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "OpenClinic GA is aware of these vulnerabilities but has not provided any confirmation of their resolution. Please upgrade to the latest version to ensure you have all current fixes."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14489",
    "datePublished": "2020-07-29T12:24:11.103Z",
    "dateReserved": "2020-06-19T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:46:22.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-14489",
      "date": "2026-10-14",
      "epss": "0.00982",
      "percentile": "0.61487"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.09.02:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A64E5CCD-1F0D-46B2-9AE7-C917928D2788",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.89.05b:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BE2E5CDB-B864-45E4-A7EA-D7EE93BC2453",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques."
          },
          {
            "lang": "es",
            "value": "OpenClinic GA versiones 5.09.02 y 5.89.05b, almacena contrase\u00f1as con una complejidad de hash inadecuada, lo que puede permitir a un atacante recuperar contrase\u00f1as usando t\u00e9cnicas conocidas de descifrado de contrase\u00f1as"
          }
        ],
        "id": "CVE-2020-14489",
        "lastModified": "2024-11-21T05:03:22.923",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.5,
              "impactScore": 3.6,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-07-29T13:15:09.993",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-522"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-522"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.