CVE-2020-11640 (GCVE-0-2020-11640)
Vulnerability from cvelistv5 – Published: 2024-07-23 17:36 – Updated: 2024-08-04 11:35- CWE-269 - Improper Privilege Management
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| ABB | Advant MOD 300 AdvaBuild |
Affected:
3.0 , ≤ 3.7 SP2
(update)
|
guessed | |
| abb | advabuild |
Affected:
3.0 , ≤ 3.7sp2
(custom)
cpe:2.3:a:abb:advabuild:*:*:*:*:*:*:mod_300:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:abb:advabuild:*:*:*:*:*:*:mod_300:*"
],
"defaultStatus": "unknown",
"product": "advabuild",
"vendor": "abb",
"versions": [
{
"lessThanOrEqual": "3.7sp2",
"status": "affected",
"version": "3.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-11640",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:09:49.474898Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T19:00:53.120Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.681Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Advant MOD 300 AdvaBuild",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "3.7 SP2",
"status": "affected",
"version": "3.0",
"versionType": "update"
}
]
}
],
"datePublic": "2024-07-22T17:33:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u0026nbsp;\u003cbr\u003e\u003cbr\u003eImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e"
}
],
"value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T17:36:51.458Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
}
],
"value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Elevation of Privilege",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-11640",
"datePublished": "2024-07-23T17:36:51.458Z",
"dateReserved": "2020-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-11640",
"date": "2026-11-29",
"epss": "0.00372",
"percentile": "0.23177"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:advabuild:*:*:*:*:*:advant_mod_300:*:*",
"matchCriteriaId": "2B2DD8A5-17FB-4CCF-ABC0-2388B43D07F2",
"versionEndExcluding": "3.7",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:abb:advabuild:3.7:-:*:*:*:advant_mod_300:*:*",
"matchCriteriaId": "88348546-89FF-4F82-8246-F9E08B585C78",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:abb:advabuild:3.7:sp1:*:*:*:advant_mod_300:*:*",
"matchCriteriaId": "4E2D62C1-9F2D-42D5-997B-0880469C82E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:abb:advabuild:3.7:sp2:*:*:*:advant_mod_300:*:*",
"matchCriteriaId": "9D462F34-AD38-4EA0-97CE-9FE7A558920F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
},
{
"lang": "es",
"value": "AdvaBuild utiliza una cola de comandos para iniciar determinadas operaciones. Un atacante que obtenga acceso a la cola de comandos puede usarla para lanzar un ataque ejecutando cualquier ejecutable en el nodo AdvaBuild. Los ejecutables que se pueden ejecutar no se limitan a ejecutables espec\u00edficos de AdvaBuild. Vulnerabilidad de gesti\u00f3n de privilegios inadecuada en ABB Advant MOD 300 AdvaBuild. Este problema afecta a Advant MOD 300 AdvaBuild: desde 3.0 hasta 3.7 SP2."
}
],
"id": "CVE-2020-11640",
"lastModified": "2025-12-19T15:57:45.533",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
}
]
},
"published": "2024-07-23T18:15:05.083",
"references": [
{
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.681Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:abb:advabuild:*:*:*:*:*:*:mod_300:*"
],
"defaultStatus": "unknown",
"product": "advabuild",
"vendor": "abb",
"versions": [
{
"lessThanOrEqual": "3.7sp2",
"status": "affected",
"version": "3.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-11640",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:09:49.474898Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T18:48:23.721Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Advant MOD 300 AdvaBuild",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "3.7 SP2",
"status": "affected",
"version": "3.0",
"versionType": "update"
}
]
}
],
"datePublic": "2024-07-22T17:33:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u0026nbsp;\u003cbr\u003e\u003cbr\u003eImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e"
}
],
"value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T17:36:51.458Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
}
],
"value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Elevation of Privilege",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-11640",
"datePublished": "2024-07-23T17:36:51.458Z",
"dateReserved": "2020-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.