CVE-2019-20463 (GCVE-0-2019-20463)
Vulnerability from cvelistv5 – Published: 2021-04-02 15:30 – Updated: 2024-08-05 02:39
VLAI
Summary
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A crash and reboot can be triggered by crafted IP traffic, as demonstrated by the Nikto vulnerability scanner. For example, sending the 111111 string to UDP port 20188 causes a reboot. To deny service for a long time period, the crafted IP traffic may be sent periodically.
Severity
7.5 (High)
CWE
- n/a
Assigner
References
2 references
Date Public
2021-03-30 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:39:10.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2021-03-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A crash and reboot can be triggered by crafted IP traffic, as demonstrated by the Nikto vulnerability scanner. For example, sending the 111111 string to UDP port 20188 causes a reboot. To deny service for a long time period, the crafted IP traffic may be sent periodically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T00:07:52.903Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-20463",
"datePublished": "2021-04-02T15:30:35.000Z",
"dateReserved": "2020-02-17T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:39:10.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-20463",
"date": "2026-07-01",
"epss": "0.01715",
"percentile": "0.74596"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-20463\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-04-02T16:15:12.977\",\"lastModified\":\"2024-11-21T04:38:32.493\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A crash and reboot can be triggered by crafted IP traffic, as demonstrated by the Nikto vulnerability scanner. For example, sending the 111111 string to UDP port 20188 causes a reboot. To deny service for a long time period, the crafted IP traffic may be sent periodically.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en los dispositivos Sannce Smart HD Wifi Security Camera EAN 2 950004 595317.\u0026#xa0;Un bloqueo y reinicio puede ser desencadenado por el tr\u00e1fico IP dise\u00f1ado, como es demostrado por el esc\u00e1ner de vulnerabilidades de Nikto.\u0026#xa0;Por ejemplo, enviando la cadena 111111 hacia al puerto UDP 20188 causa un reinicio.\u0026#xa0;Para denegar el servicio durante un per\u00edodo prolongado, el tr\u00e1fico IP dise\u00f1ado puede ser enviado peri\u00f3dicamente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8123D4F3-B94B-405B-9FF5-0CA27A0B719E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"548EDA0C-3BBF-44AF-99DC-73796B27874D\"}]}]}],\"references\":[{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…