CVE-2019-16382 (GCVE-0-2019-16382)
Vulnerability from cvelistv5 – Published: 2020-03-19 16:57 – Updated: 2024-08-05 01:17
VLAI
Summary
An issue was discovered in Ivanti Workspace Control 10.3.110.0. One is able to bypass Ivanti's FileGuard folder protection by renaming the WMTemp work folder used by PowerGrid. A malicious PowerGrid XML file can then be created, after which the folder is renamed back to its original value. Also, CVE-2018-15591 exploitation can consequently be achieved by using PowerGrid with the /SEE parameter to execute the arbitrary command specified in the XML file.
Severity
9.8 (Critical)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://twitter.com/jmoosdijk | x_refsource_MISC |
| https://forums.ivanti.com/s/article/Security-Aler… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:17:39.387Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://twitter.com/jmoosdijk"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Ivanti Workspace Control 10.3.110.0. One is able to bypass Ivanti\u0027s FileGuard folder protection by renaming the WMTemp work folder used by PowerGrid. A malicious PowerGrid XML file can then be created, after which the folder is renamed back to its original value. Also, CVE-2018-15591 exploitation can consequently be achieved by using PowerGrid with the /SEE parameter to execute the arbitrary command specified in the XML file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-19T16:57:41.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://twitter.com/jmoosdijk"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-16382",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Ivanti Workspace Control 10.3.110.0. One is able to bypass Ivanti\u0027s FileGuard folder protection by renaming the WMTemp work folder used by PowerGrid. A malicious PowerGrid XML file can then be created, after which the folder is renamed back to its original value. Also, CVE-2018-15591 exploitation can consequently be achieved by using PowerGrid with the /SEE parameter to execute the arbitrary command specified in the XML file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://twitter.com/jmoosdijk",
"refsource": "MISC",
"url": "https://twitter.com/jmoosdijk"
},
{
"name": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019",
"refsource": "CONFIRM",
"url": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-16382",
"datePublished": "2020-03-19T16:57:41.000Z",
"dateReserved": "2019-09-17T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:17:39.387Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-16382",
"date": "2026-06-04",
"epss": "0.06027",
"percentile": "0.90874"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-16382\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-03-19T17:15:12.890\",\"lastModified\":\"2024-11-21T04:30:36.233\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Ivanti Workspace Control 10.3.110.0. One is able to bypass Ivanti\u0027s FileGuard folder protection by renaming the WMTemp work folder used by PowerGrid. A malicious PowerGrid XML file can then be created, after which the folder is renamed back to its original value. Also, CVE-2018-15591 exploitation can consequently be achieved by using PowerGrid with the /SEE parameter to execute the arbitrary command specified in the XML file.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en Ivanti Workspace Control versi\u00f3n 10.3.110.0. Uno es capaz de omitir la protecci\u00f3n de la carpeta FileGuard de Ivanti al renombrar la carpeta de trabajo WMTemp usada por PowerGrid. Un archivo XML de PowerGrid malicioso puede entonces ser creado, despu\u00e9s de que la carpeta cambia de nombre a su valor original. Adem\u00e1s, una explotaci\u00f3n de CVE-2018-15591 puede ser lograda en consecuencia utilizando PowerGrid con el par\u00e1metro /SEE para ejecutar el comando arbitrario especificado en el archivo XML.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ivanti:workspace_control:10.3.110.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC08C246-7F5C-4745-8F17-AA6236BC65B6\"}]}]}],\"references\":[{\"url\":\"https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://twitter.com/jmoosdijk\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://twitter.com/jmoosdijk\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…