CVE-2019-14451 (GCVE-0-2019-14451)

Vulnerability from cvelistv5 – Published: 2019-10-25 16:27 – Updated: 2024-08-05 00:19
VLAI
Summary
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
CWE
  • n/a
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:19:41.075Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.repetier-server.com/manuals/0.91/index.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.repetier-server.com/knowledgebase/security-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an \"external command\" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-25T16:27:22.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.repetier-server.com/manuals/0.91/index.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.repetier-server.com/knowledgebase/security-advisory/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-14451",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an \"external command\" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.repetier-server.com/manuals/0.91/index.html",
              "refsource": "MISC",
              "url": "https://www.repetier-server.com/manuals/0.91/index.html"
            },
            {
              "name": "https://www.repetier-server.com/knowledgebase/security-advisory/",
              "refsource": "CONFIRM",
              "url": "https://www.repetier-server.com/knowledgebase/security-advisory/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-14451",
    "datePublished": "2019-10-25T16:27:22.000Z",
    "dateReserved": "2019-07-30T00:00:00.000Z",
    "dateUpdated": "2024-08-05T00:19:41.075Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-14451",
      "date": "2026-09-23",
      "epss": "0.04451",
      "percentile": "0.90993"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:repetier-server:repetier-server:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CA956238-185C-4521-BAA6-8ED7382C1826",
                    "versionEndIncluding": "0.91",
                    "versionStartIncluding": "0.80",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an \"external command\" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart."
          },
          {
            "lang": "es",
            "value": "El archivo RepetierServer.exe en Repetier-Server versiones 0.8 hasta 0.91, no comprueba apropiadamente la estructura de datos XML proporcionada cuando se carga una nueva configuraci\u00f3n de impresora. Cuando esto se combina con CVE-2019-14450, un atacante puede cargar una configuraci\u00f3n de \"external command\" como una configuraci\u00f3n de impresora y lograr una ejecuci\u00f3n de c\u00f3digo remota. Despu\u00e9s de su explotaci\u00f3n, la carga de la configuraci\u00f3n del comando externo es dependiente de un reinicio del sistema o un reinicio del servicio."
          }
        ],
        "id": "CVE-2019-14451",
        "lastModified": "2024-11-21T04:26:46.080",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-10-25T17:15:10.837",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.repetier-server.com/knowledgebase/security-advisory/"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.repetier-server.com/manuals/0.91/index.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.repetier-server.com/knowledgebase/security-advisory/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.repetier-server.com/manuals/0.91/index.html"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-434"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…