CVE-2018-7675 (GCVE-0-2018-7675)

Vulnerability from cvelistv5 – Published: 2018-03-07 22:00 – Updated: 2024-08-05 06:31
VLAI
Title
Potential Information Disclosure in Sentinel
Summary
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
CWE
  • Potential information leakage
Assigner
CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
References
Impacted products
Vendor Product Version CPE status
NetIQ Corporation Sentinel Affected: Sentinel 8.1.X 8.1.X
guessed Create a notification for this product.
Date Public
2018-03-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:31:05.057Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Sentinel",
          "vendor": "NetIQ Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Sentinel 8.1.X 8.1.X"
            }
          ]
        }
      ],
      "datePublic": "2018-03-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Potential information leakage",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:52.000Z",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Potential Information Disclosure in Sentinel",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "ID": "CVE-2018-7675",
          "STATE": "PUBLIC",
          "TITLE": "Potential Information Disclosure in Sentinel"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Sentinel",
                      "version": {
                        "version_data": [
                          {
                            "affected": "=",
                            "version_affected": "=",
                            "version_name": "Sentinel 8.1.X",
                            "version_value": "8.1.X"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Potential information leakage"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.netiq.com/support/kb/doc.php?id=7022706",
              "refsource": "CONFIRM",
              "url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2018-7675",
    "datePublished": "2018-03-07T22:00:00.000Z",
    "dateReserved": "2018-03-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:31:05.057Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-7675",
      "date": "2026-11-18",
      "epss": "0.00539",
      "percentile": "0.46072"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:microfocus:sentinel:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9DAB81CA-AAF5-4F7C-825B-303FC5A5E29D",
                    "versionEndIncluding": "8.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing."
          },
          {
            "lang": "es",
            "value": "En NetIQ Sentinel, en versiones anteriores a la 8.1.x, un usuario de Sentinel inicia sesi\u00f3n en la interfaz web de Sentinel. Tras realizar algunas tareas en Sentinel, el usuario no cierra sesi\u00f3n, sino que se vuelve inactivo durante un tiempo. Esto provoca que la interfaz agote el tiempo de sesi\u00f3n activa y requiera que el usuario se vuelva a autenticar. Si otro usuario decide iniciar sesi\u00f3n, sus credenciales se aceptar\u00e1n. Aunque el usuario no hereda ning\u00fan privilegio del otro usuario, puede ver la pantalla anterior. En este caso, es posible que el usuario pueda ver los eventos de otro usuario o la informaci\u00f3n de configuraci\u00f3n para la pantalla que est\u00e9 mostrando en ese momento."
          }
        ],
        "id": "CVE-2018-7675",
        "lastModified": "2024-11-21T04:12:31.087",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 6.8,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 2.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 1.3,
              "impactScore": 1.4,
              "source": "security@opentext.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 1.6,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-03-07T22:29:00.307",
        "references": [
          {
            "source": "security@opentext.com",
            "url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
          }
        ],
        "sourceIdentifier": "security@opentext.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-200"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.