CVE-2018-15480 (GCVE-0-2018-15480)
Vulnerability from cvelistv5 – Published: 2018-08-30 17:00 – Updated: 2024-08-05 09:54- n/a
| URL | Tags |
|---|---|
| https://www.swisscom.ch/content/dam/swisscom/de/a… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:54:03.476Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-08-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-30T16:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-15480",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt",
"refsource": "MISC",
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-15480",
"datePublished": "2018-08-30T17:00:00.000Z",
"dateReserved": "2018-08-17T00:00:00.000Z",
"dateUpdated": "2024-08-05T09:54:03.476Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-15480",
"date": "2026-11-17",
"epss": "0.01024",
"percentile": "0.64091"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_switch_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70FCB4DD-851D-4BC3-A21C-1FCD0EF98C96",
"versionEndExcluding": "2.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_switch:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA509BE-58A0-42ED-9443-315A476E56C8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_switch_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C5F5BB2-A2D2-4AB7-989C-3A57FAE80680",
"versionEndExcluding": "3.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_switch:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "AD1FDF37-FB91-4785-9E7B-18E998588CCC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_button_plus_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "96731591-1B70-4959-A6FC-8E77825ED201",
"versionEndExcluding": "2.73",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_button_plus:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E19B7F6F-B18D-4DDA-9F9B-53E4930214A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_button_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF02CFF8-3F22-439B-A577-23A89B78CDC5",
"versionEndExcluding": "2.73",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_button:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6FD827E0-F663-42D3-A4A4-6FE25A456D1F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_switch_eu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78EE8AA5-3DF6-4675-BC6D-AA04178AF4E9",
"versionEndExcluding": "3.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_switch_eu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "021F3B3F-C2DD-489B-B11C-F5DDD91F80DB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_bulb_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80C4BEFA-1421-4277-BBD3-7D14C2A9094B",
"versionEndExcluding": "2.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_bulb:-:*:*:*:*:*:*:*",
"matchCriteriaId": "48FA62DC-223A-4076-AA70-6607595225E4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mystrom:wifi_led_strip_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2A75310A-A268-4A10-A9E9-7C1EC40F4B0A",
"versionEndExcluding": "3.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mystrom:wifi_led_strip:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEF13066-B15B-4C40-BCF3-06F60D3EC95C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en WiFi Switch V1 en versiones anteriores a la 2.66, WiFi Switch V2 en versiones anteriores a la 3.80, WiFi Switch EU en versiones anteriores a la 3.80, WiFi Bulb en versiones anteriores a la 2.58, WiFi LED Strip en versiones anteriores a la 3.80, WiFi Button en versiones anteriores a la 2.73 y WiFi Button Plus en versiones anteriores a la 2.73, de myStrom. La API cloud ten\u00eda un par\u00e1metro oculto, lo que permit\u00eda que un usuario autenticado reconfigurase la URL del servidor para un dispositivo registrado en su cuenta. En combinaci\u00f3n con una vulnerabilidad de registro inseguro de dispositivos, esto permit\u00eda que un atacante reconfigurase un dispositivo registrado de forma maliciosa en su propia r\u00e9plica corrupta de la API de myStrom y lanzase comandos al dispositivo, incluyendo los comandos de actualizaci\u00f3n de firmware."
}
],
"id": "CVE-2018-15480",
"lastModified": "2024-11-21T03:50:54.217",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-08-30T17:29:01.613",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.swisscom.ch/content/dam/swisscom/de/about/nachhaltigkeit/digitale-schweiz/sicherheit/bug-bounty/files/cve-2018-15476ff.txt"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.