CVE-2018-1251 (GCVE-0-2018-1251)
Vulnerability from cvelistv5 – Published: 2018-09-28 18:00 – Updated: 2024-09-16 18:03- URL Redirection
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2018/Sep/30 | mailing-listx_refsource_FULLDISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dell EMC | Dell EMC Unity |
Affected:
unspecified , < 4.3.1.1525703027
(custom)
|
guessed | |
| Dell EMC | Dell EMC UnityVSA |
Affected:
unspecified , < 4.3.1.1525703027
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:51:49.174Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20180918 DSA-2018-101: Dell EMC Unity Family Multiple Vulnerabilities",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2018/Sep/30"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Dell EMC Unity",
"vendor": "Dell EMC",
"versions": [
{
"lessThan": "4.3.1.1525703027",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Dell EMC UnityVSA",
"vendor": "Dell EMC",
"versions": [
{
"lessThan": "4.3.1.1525703027",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unity and UnityVSA versions prior to 4.3.1.1525703027 contains a URL Redirection vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to redirect Unity users to arbitrary web URLs by tricking the victim user to click on a maliciously crafted Unisphere URL. Attacker could potentially phish information, including Unisphere users\u0027 credentials, from the victim once they are redirected."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "URL Redirection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-28T17:57:01.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"name": "20180918 DSA-2018-101: Dell EMC Unity Family Multiple Vulnerabilities",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "https://seclists.org/fulldisclosure/2018/Sep/30"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2018-09-18T04:00:00.000Z",
"ID": "CVE-2018-1251",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Dell EMC Unity",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "4.3.1.1525703027"
}
]
}
},
{
"product_name": "Dell EMC UnityVSA",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "4.3.1.1525703027"
}
]
}
}
]
},
"vendor_name": "Dell EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unity and UnityVSA versions prior to 4.3.1.1525703027 contains a URL Redirection vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to redirect Unity users to arbitrary web URLs by tricking the victim user to click on a maliciously crafted Unisphere URL. Attacker could potentially phish information, including Unisphere users\u0027 credentials, from the victim once they are redirected."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "URL Redirection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20180918 DSA-2018-101: Dell EMC Unity Family Multiple Vulnerabilities",
"refsource": "FULLDISC",
"url": "https://seclists.org/fulldisclosure/2018/Sep/30"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2018-1251",
"datePublished": "2018-09-28T18:00:00.000Z",
"dateReserved": "2017-12-06T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:03:36.680Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-1251",
"date": "2026-11-10",
"epss": "0.02455",
"percentile": "0.8454"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:emc_unity_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CE80D21A-B8AA-4429-9FE7-01522F9595A5",
"versionEndExcluding": "4.3.1.1525703027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:emc_unity:-:*:*:*:*:*:*:*",
"matchCriteriaId": "08D30CDA-12CB-4071-94EC-6186ED329072",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:emc_unityvsa:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FCAA53DD-EEFF-440F-9979-09B8521FDB64",
"versionEndExcluding": "4.3.1.1525703027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unity and UnityVSA versions prior to 4.3.1.1525703027 contains a URL Redirection vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to redirect Unity users to arbitrary web URLs by tricking the victim user to click on a maliciously crafted Unisphere URL. Attacker could potentially phish information, including Unisphere users\u0027 credentials, from the victim once they are redirected."
},
{
"lang": "es",
"value": "Dell EMC Unity y UnityVSA en versiones anteriores a la 4.3.1.1525703027 contiene una vulnerabilidad de redirecci\u00f3n de URL. Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad para redirigir a los usuarios de Unity a URL web arbitrarias enga\u00f1ando a la v\u00edctima para que haga clic en una URL de Unisphere maliciosamente manipulada. Los atacantes podr\u00edan captar informaci\u00f3n, incluyendo las credenciales de usuario de Unisphere, de la v\u00edctima una vez son redirigidos."
}
],
"id": "CVE-2018-1251",
"lastModified": "2024-11-21T03:59:28.067",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-09-28T18:29:01.083",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2018/Sep/30"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2018/Sep/30"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-601"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.