CVE-2018-10098 (GCVE-0-2018-10098)

Vulnerability from cvelistv5 – Published: 2018-07-13 17:00 – Updated: 2024-08-05 07:32
VLAI
Summary
In MicroWorld eScan Internet Security Suite (ISS) for Business 14.0.1400.2029, the driver econceal.sys allows a non-privileged user to send a 0x830020E0 IOCTL request to \\.\econceal to cause a denial of service (BSOD).
CWE
  • n/a
References
URL Tags
http://seclists.org/fulldisclosure/2018/Jul/53 mailing-listx_refsource_FULLDISC
Date Public
2018-07-12 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:32:01.180Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20180712 eScan ISS for Business v14.0.1400.2029 - BSOD through of a\tIOCTL",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2018/Jul/53"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-07-12T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In MicroWorld eScan Internet Security Suite (ISS) for Business 14.0.1400.2029, the driver econceal.sys allows a non-privileged user to send a 0x830020E0 IOCTL request to \\\\.\\econceal to cause a denial of service (BSOD)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-13T16:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20180712 eScan ISS for Business v14.0.1400.2029 - BSOD through of a\tIOCTL",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2018/Jul/53"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-10098",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In MicroWorld eScan Internet Security Suite (ISS) for Business 14.0.1400.2029, the driver econceal.sys allows a non-privileged user to send a 0x830020E0 IOCTL request to \\\\.\\econceal to cause a denial of service (BSOD)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20180712 eScan ISS for Business v14.0.1400.2029 - BSOD through of a\tIOCTL",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2018/Jul/53"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-10098",
    "datePublished": "2018-07-13T17:00:00.000Z",
    "dateReserved": "2018-04-13T00:00:00.000Z",
    "dateUpdated": "2024-08-05T07:32:01.180Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-10098",
      "date": "2026-09-28",
      "epss": "0.00288",
      "percentile": "0.19117"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:escanav:escan_internet_security_suite:14.0.1400.2029:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8704AFD9-73B7-4BB1-8DF9-98EC8D72FBA5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "In MicroWorld eScan Internet Security Suite (ISS) for Business 14.0.1400.2029, the driver econceal.sys allows a non-privileged user to send a 0x830020E0 IOCTL request to \\\\.\\econceal to cause a denial of service (BSOD)."
          },
          {
            "lang": "es",
            "value": "En MicroWorld eScan Internet Security Suite (ISS) for Business 14.0.1400.2029, el controlador econceal.sys permite que un usuario no privilegiado env\u00ede una petici\u00f3n IOCTL 0x830020E0 a \\\\.\\econceal para provocar una denegaci\u00f3n de servicio (BSOD)."
          }
        ],
        "id": "CVE-2018-10098",
        "lastModified": "2024-11-21T03:40:49.260",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 4.9,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 6.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-07-13T17:29:00.263",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Mailing List",
              "Third Party Advisory"
            ],
            "url": "http://seclists.org/fulldisclosure/2018/Jul/53"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mailing List",
              "Third Party Advisory"
            ],
            "url": "http://seclists.org/fulldisclosure/2018/Jul/53"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…